0% found this document useful (0 votes)
22 views1 page

VBC Concert Hall - Domestic-Kitchen - Spool Drawing - JJ - 02142025

The document outlines the specifications for domestic kitchen plumbing, including various pipe sizes, lengths, and fittings required for cold and hot water, as well as natural gas. It includes detailed descriptions of components such as elbows, reducers, and tees, along with notes on existing fixtures and necessary modifications. Additionally, it references revisions and approvals related to the project, indicating ongoing updates and coordination with design requirements.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
22 views1 page

VBC Concert Hall - Domestic-Kitchen - Spool Drawing - JJ - 02142025

The document outlines the specifications for domestic kitchen plumbing, including various pipe sizes, lengths, and fittings required for cold and hot water, as well as natural gas. It includes detailed descriptions of components such as elbows, reducers, and tees, along with notes on existing fixtures and necessary modifications. Additionally, it references revisions and approvals related to the project, indicating ongoing updates and coordination with design requirements.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

TOTAL PIPE DOMESTIC KITCHEN TOTAL PIPE FITTING DOMESTIC KITCHEN

Size Length Qty. Size Description


P - Cold Water P - Cold Water
1 1/2" 20.58 ft 2 1 1/2"x1 1/2" 90 ELBOW SHOULD BE WXTP-120V

2007 N MEMORIAL PKWY,


BUT NO FAMILY YET

1/2" 14.98 ft 1 1/2"x1/2" 90 ELBOW THIS IS XT-35


TEMPORARY

2" 134.50 ft 9 2"x2" 90 ELBOW


3/4" 64.28 ft 8 3/4"x3/4" 90 ELBOW HUNTSVILLE AL, 35801
P - Hot Water 1 1 1/2"x1/2" PIPE REDUCER
1 1/2" 13.96 ft 1 2"x1 1/2" PIPE REDUCER
1" 20.22 ft 4 2"x3/4" PIPE REDUCER
1/2" 8.69 ft 1 2"x2"x1 1/2" TEE

VBC CONCERT HALL


2" 90.65 ft 6 2"x2"x2" TEE
3" 46.14 ft P - Hot Water
3/4" 62.29 ft 2 1 1/2"x1 1/2" 90 ELBOW
P - Hot Water Circulation 3 1"x1" 90 ELBOW
1" 2.72 ft 1 1/2"x1/2" 90 ELBOW
3/4" 66.29 ft 4 2"x2" 90 ELBOW

HUNTSVILLE ALABAMA
P - Natural Gas 3 3"x3" 90 ELBOW
1 1/4" 17.11 ft 13 3/4"x3/4" 90 ELBOW
2" 94.12 ft 1 2" CAP
3/4" 18.95 ft 1 1 1/2"x1" PIPE REDUCER
3 1 1/2"x3/4" PIPE REDUCER
1 1"x1/2" PIPE REDUCER
2 1"x3/4" PIPE REDUCER
2 2"x1 1/2" PIPE REDUCER
2 2"x3/4" PIPE REDUCER
2 3"x2" PIPE REDUCER
3 1 1/2"x1 1/2"x1 1/2" TEE
3 1"x1"x1" TEE
3 2"x2"x2" TEE
1 3"x3"x3" TEE
P - Hot Water Circulation
1 1"x1" 90 ELBOW
4 3/4"x3/4" 90 ELBOW
1 3/4" CAP
3 1"x3/4" PIPE REDUCER
ISSUES
1 1"x1"x1" TEE
NO. DESCRIPTION DATE
P - Natural Gas
2 1 1/4"x1 1/4" 90 ELBOW
7 2"x2" 90 ELBOW
3 3/4"x3/4" 90 ELBOW
2 2"x1 1/4" PIPE REDUCER
1 2"x3/4" PIPE REDUCER REVISIONS
3 2"x2"x2" TEE NO. DESCRIPTION DATE
1 ADDENDUM 2 10/11/2023

N LEVEL 1 - DOMESTIC - KITCHEN - OVERALL N UNDERGROUND - DOMESTIC - KITCHEN BASEMENT - OVERALL


5 5 5 10 15 20
2
3
ADDENDUM 5
ADDENDUM 6
10/19/2024
10/26/2023
5 5 5 10 15 20
4 ASI 8 11/04/2024
1/8" = 1'-0" 1/8" = 1'-0"
SCALE FEET SCALE FEET

STAMP

ISSUED DATE / TIME:

2/14/2025 5:37:47 PM
APPROVED BY: DESIGNED BY:

Approver Designer
NOTES: DRAWN BY: CHECKED BY:
1. REMOVE EXISTING DRINKING FOUNTAIN. NEW BF-1 TO BE INSTALL IN THIS LOCATION. PROVIDE
J.PANGILINAN C.NICASIO
NEW P-TRAP AND STOP. TIE INTO EXISTING SANITARY AND VENT AND WATER SUPPLY.
2. EXISTING WASHING MACHINE CONNECTION TO BE ABANDONED. CAP SANITARY LINE AT SUPPLY PROJECT NO: ISSUE:
BOX AND PROVIDE ACCESS PANEL ON NEW WALL TO COVER VALVES AND SANITARY.
3. EXISTING LAVATORIES TO BE REMOVED. PROVIDE NEW STOPS AND P-TRAP AND INSTALL NEW 4
LEGEND:
LAVATORY ON EXISTING SANITARY, VENT, AND WATER SUPPLIES.. SHEET NUMBER:
4. EXISTING SHOWER DRAIN TO REMAIN. SHOWER TO BE TILED BY OTHERS. COORDINATE WITH
NEW TILE AND ADJUST DRAIN AS REQUIRED. - DOMESTIC COLD WATER P112.1
5. EXISTING DRESSING ROOM FIXTURES TO BE REMOVED. TAKE EXISTING VENT BACK TO MAIN
SHEET NAME:
AND CAP. SAW CUT FLOOR AND CAP SANITARY PIPING BELOW FLOOR. SITE VERIFY ALL
- DOMESTIC HOT WATER
EXISTING STORM PIPING ABOVE CEILING AND COORDINATE WITH NEW WORK. NOTIFY
ARCHITECT AND ENGINEER OF ANY CONFLICTS. KITCHEN - DOMESTIC -
6. EXISTING SANITARY PIT. REMOVE LID AND ROUTE VENT UNDERGROUND TO BUILDING, THEN DOMESTIC HOT WATER OVERALL
-
RECIRCULATION
DOMESTIC - KITCHEN - ISOMETRIC VIEW EXTEND TO A VTR. PIT SHALL BE CHECKED AND VERIFIED THE STRUCTURE / FRAMING CAN
ACCOMMODATE TRAFFIC RATED REQUIREMENTS. LID TO BE REMOVED AND REPLACED WITH PAPER: SCALE:
NOT TO SCALE NEW TRAFFIC RATED LID THAT IS ABLE TO BE BOLTED DOWN. - NATURAL GAS
7. EXISTING WASHING MACHINE WASTE AND VENT TO TIE INTO NEW BOTTLE FILLER.
ARCH D 1/8" = 1'-0"