TOTAL PIPE DOMESTIC KITCHEN TOTAL PIPE FITTING DOMESTIC KITCHEN
Size Length Qty. Size Description
P - Cold Water P - Cold Water
1 1/2" 20.58 ft 2 1 1/2"x1 1/2" 90 ELBOW SHOULD BE WXTP-120V
2007 N MEMORIAL PKWY,
BUT NO FAMILY YET
1/2" 14.98 ft 1 1/2"x1/2" 90 ELBOW THIS IS XT-35
TEMPORARY
2" 134.50 ft 9 2"x2" 90 ELBOW
3/4" 64.28 ft 8 3/4"x3/4" 90 ELBOW HUNTSVILLE AL, 35801
P - Hot Water 1 1 1/2"x1/2" PIPE REDUCER
1 1/2" 13.96 ft 1 2"x1 1/2" PIPE REDUCER
1" 20.22 ft 4 2"x3/4" PIPE REDUCER
1/2" 8.69 ft 1 2"x2"x1 1/2" TEE
VBC CONCERT HALL
2" 90.65 ft 6 2"x2"x2" TEE
3" 46.14 ft P - Hot Water
3/4" 62.29 ft 2 1 1/2"x1 1/2" 90 ELBOW
P - Hot Water Circulation 3 1"x1" 90 ELBOW
1" 2.72 ft 1 1/2"x1/2" 90 ELBOW
3/4" 66.29 ft 4 2"x2" 90 ELBOW
HUNTSVILLE ALABAMA
P - Natural Gas 3 3"x3" 90 ELBOW
1 1/4" 17.11 ft 13 3/4"x3/4" 90 ELBOW
2" 94.12 ft 1 2" CAP
3/4" 18.95 ft 1 1 1/2"x1" PIPE REDUCER
3 1 1/2"x3/4" PIPE REDUCER
1 1"x1/2" PIPE REDUCER
2 1"x3/4" PIPE REDUCER
2 2"x1 1/2" PIPE REDUCER
2 2"x3/4" PIPE REDUCER
2 3"x2" PIPE REDUCER
3 1 1/2"x1 1/2"x1 1/2" TEE
3 1"x1"x1" TEE
3 2"x2"x2" TEE
1 3"x3"x3" TEE
P - Hot Water Circulation
1 1"x1" 90 ELBOW
4 3/4"x3/4" 90 ELBOW
1 3/4" CAP
3 1"x3/4" PIPE REDUCER
ISSUES
1 1"x1"x1" TEE
NO. DESCRIPTION DATE
P - Natural Gas
2 1 1/4"x1 1/4" 90 ELBOW
7 2"x2" 90 ELBOW
3 3/4"x3/4" 90 ELBOW
2 2"x1 1/4" PIPE REDUCER
1 2"x3/4" PIPE REDUCER REVISIONS
3 2"x2"x2" TEE NO. DESCRIPTION DATE
1 ADDENDUM 2 10/11/2023
N LEVEL 1 - DOMESTIC - KITCHEN - OVERALL N UNDERGROUND - DOMESTIC - KITCHEN BASEMENT - OVERALL
5 5 5 10 15 20
2
3
ADDENDUM 5
ADDENDUM 6
10/19/2024
10/26/2023
5 5 5 10 15 20
4 ASI 8 11/04/2024
1/8" = 1'-0" 1/8" = 1'-0"
SCALE FEET SCALE FEET
STAMP
ISSUED DATE / TIME:
2/14/2025 5:37:47 PM
APPROVED BY: DESIGNED BY:
Approver Designer
NOTES: DRAWN BY: CHECKED BY:
1. REMOVE EXISTING DRINKING FOUNTAIN. NEW BF-1 TO BE INSTALL IN THIS LOCATION. PROVIDE
J.PANGILINAN C.NICASIO
NEW P-TRAP AND STOP. TIE INTO EXISTING SANITARY AND VENT AND WATER SUPPLY.
2. EXISTING WASHING MACHINE CONNECTION TO BE ABANDONED. CAP SANITARY LINE AT SUPPLY PROJECT NO: ISSUE:
BOX AND PROVIDE ACCESS PANEL ON NEW WALL TO COVER VALVES AND SANITARY.
3. EXISTING LAVATORIES TO BE REMOVED. PROVIDE NEW STOPS AND P-TRAP AND INSTALL NEW 4
LEGEND:
LAVATORY ON EXISTING SANITARY, VENT, AND WATER SUPPLIES.. SHEET NUMBER:
4. EXISTING SHOWER DRAIN TO REMAIN. SHOWER TO BE TILED BY OTHERS. COORDINATE WITH
NEW TILE AND ADJUST DRAIN AS REQUIRED. - DOMESTIC COLD WATER P112.1
5. EXISTING DRESSING ROOM FIXTURES TO BE REMOVED. TAKE EXISTING VENT BACK TO MAIN
SHEET NAME:
AND CAP. SAW CUT FLOOR AND CAP SANITARY PIPING BELOW FLOOR. SITE VERIFY ALL
- DOMESTIC HOT WATER
EXISTING STORM PIPING ABOVE CEILING AND COORDINATE WITH NEW WORK. NOTIFY
ARCHITECT AND ENGINEER OF ANY CONFLICTS. KITCHEN - DOMESTIC -
6. EXISTING SANITARY PIT. REMOVE LID AND ROUTE VENT UNDERGROUND TO BUILDING, THEN DOMESTIC HOT WATER OVERALL
-
RECIRCULATION
DOMESTIC - KITCHEN - ISOMETRIC VIEW EXTEND TO A VTR. PIT SHALL BE CHECKED AND VERIFIED THE STRUCTURE / FRAMING CAN
ACCOMMODATE TRAFFIC RATED REQUIREMENTS. LID TO BE REMOVED AND REPLACED WITH PAPER: SCALE:
NOT TO SCALE NEW TRAFFIC RATED LID THAT IS ABLE TO BE BOLTED DOWN. - NATURAL GAS
7. EXISTING WASHING MACHINE WASTE AND VENT TO TIE INTO NEW BOTTLE FILLER.
ARCH D 1/8" = 1'-0"