0% found this document useful (0 votes)
33 views15 pages

DMW Scada Interface Detilas

The document provides IP details for various PLCs, HMIs, leak testers, scanners, and data logging PCs across multiple systems (ST-329, ST-330, ST-327, ST-333, ST-328, SCADA-1, and SCADA-2). It also outlines the job block details for pre-assembly, post-assembly, and head jobs, including data types and address points for communication between PLCs and SCADA systems. Additionally, it includes status and result parameters for job processing, such as pass and fail counts, and various string data related to job results.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
33 views15 pages

DMW Scada Interface Detilas

The document provides IP details for various PLCs, HMIs, leak testers, scanners, and data logging PCs across multiple systems (ST-329, ST-330, ST-327, ST-333, ST-328, SCADA-1, and SCADA-2). It also outlines the job block details for pre-assembly, post-assembly, and head jobs, including data types and address points for communication between PLCs and SCADA systems. Additionally, it includes status and result parameters for job processing, such as pass and fail counts, and various string data related to job results.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd

ST-329 IP DETAILS ST-330 IP DETAILS

PLC 192.168.1.161 PLC 192.168.1.164


HMI 192.168.1.171 HMI 192.168.1.174
LEAK TESTETR 192.168.1.181 LEAK TESTETR 192.168.1.184
SCANNER 192.168.1.191 SCANNER 192.168.1.194
DATALOG PC 192.168.1.151 DATALOG PC 192.168.1.154

ST-327 IP DETAILS ST-333 IP DETAILS


PLC 192.168.1.162 PLC 192.168.1.165
HMI 192.168.1.172 HMI 192.168.1.175
LEAK TESTETR 192.168.1.182 LEAK TESTETR 192.168.1.185
SCANNER 192.168.1.192 SCANNER 192.168.1.195
DATALOG PC 192.168.1.152 DATALOG PC 192.168.1.155

ST-328 IP DETAILS SCADA-2


PLC 192.168.1.163 PC 192.168.1.202
HMI 192.168.1.173
LEAK TESTETR 192.168.1.183
SCANNER 192.168.1.193
DATALOG PC 192.168.1.153

SCADA-1
PC 192.168.1.201
ST327_SCADA ( DB327) JOB- BLOCK PRE. ASSEMBLY
LABEL NAME DATA TYPE ADR. POINT
PLC_SCADA_LINK Word

MACHINE_STS Word

PLC_TO_SCADA Word

SCADA_TO_PLC Word

END_RESULT Word

PASS_CNT DWord
FAIL_CNT DWord
TOTAL_CNT DWord
S_DMC String
LT_WATER_RES String
LT_WATER_REM String
LT_OIL_RES String
LT_OIL_REM String
LT_BODY_RES String
LT_BODY_REM String
LOCK PRE. ASSEMBLY
DETAILS
1- (PLC WRITE -1 )
0- (SCADA PC WRITE 0 ) D0 // mc1 plc comm D0
0- MACHINE EMG PRESSED
1-HOME OK
2-CYCLE RUNING
3-CYCLE END ( VALUE PRESENT 5 SEC. )
D1 // Status D7
0- NO ACTION
1- SCAN DMC AS REED
2-SCAN DMC + ALL PARAMTER REED D2 // mc1 data log trigger D1 1./2 SCAN OR STORE
0- NO ACTION
1- NEW JOB PRESENT
2-REPEAT JOB
3-REJECT JOB
D3
0- NO ACTION
1- JOB PASSED ALL TEST
2- JOB FAIL ANY TEST D4 // mc1 result ok fail D6 1= Accept, 2- Reject
9999999 D5 // mc1 pass count D3
9999999 D6 // mc1 fail count D4
9999999 D7 //mc1 total count D2
DMC FULL ( 33 CHAR ) D8 // MC1 BARCODE
Exp. -000.7396CCM
D9 // mc1 leak rate D5
Exp. REJECT/ ACCPET D10
Exp. -000.7396CCM
D11
Exp. REJECT/ ACCPET D12
Exp. -000.7396CCM
D13
Exp. REJECT/ ACCPET D14
1= // repeate accepted job .//2= repeat rejected job job,//3= new job
ST328_SCADA ( DB328) JOB- BLOCK POST ASSEMBLY
LABEL NAME DATA TYPE ADR. POINT
PLC_SCADA_LINK Word

MACHINE_STS Word

PLC_TO_SCADA Word

SCADA_TO_PLC Word

END_RESULT Word

PASS_CNT DWord
FAIL_CNT DWord
TOTAL_CNT DWord
S_DMC_D String
S_DMC_U String

S_DMC_D_RESULT Word

S_DMC_U_RESULT Word

LT_WATER_RES String
LT_WATER_REM String
LT_OIL_RES String
LT_OIL_REM String
LOCK POST ASSEMBLY
DETAILS
1- (PLC WRITE -1 )
0- (SCADA PC WRITE 0 ) D0

0- MACHINE EMG PRESSED


1-HOME OK
2-CYCLE RUNING
3-CYCLE END ( VALUE PRESENT 5 SEC. ) 4-
JOB CHECK
D1
0- NO ACTION
1- SCAN DMC AS REED
3-SCAN DMC + ALL PARAMTER REED D2
0- NO ACTION
1- JOB OK ( BED PLATE & BLOCK )
2-REPEAT JOB
4-REJECT JOB
D3
0- NO ACTION
1- JOB PASSED ALL TEST
2- JOB FAIL ANY TEST D4
9999999 D5
9999999 D6
9999999 D7
DMC FULL ( 33 CHAR ) D8
DMC FULL ( 33 CHAR ) D9
0- NO ACTION
1- JOB PASSED
2- JOB NOT FOUND D10
0- NO ACTION
1- JOB PASSED
2- JOB NOT FOUND D11
Exp. -000.7396CCM
D12
Exp. REJECT/ ACCPET D13
Exp. -000.7396CCM
D14
Exp. REJECT/ ACCPET D15
1/2.
ST329_SCADA ( DB329) JOB- BED PALTE
LABEL NAME DATA TYPE ADR. POINT
PLC_SCADA_LINK Word

MACHINE_STS Word

PLC_TO_SCADA Word

SCADA_TO_PLC Word

END_RESULT Word

PASS_CNT DWord
FAIL_CNT DWord
TOTAL_CNT DWord
S_DMC String
LT_BODY_RES String
LT_BODY_REM String
JOB- BED PALTE
DETAILS
1- (PLC WRITE -1 )
0- (SCADA PC WRITE 0 ) d20
0- MACHINE EMG PRESSED
1-HOME OK
2-CYCLE RUNING
3-CYCLE END ( VALUE PRESENT 5 SEC. )
d21
0- NO ACTION
1- SCAN DMC AS REED
3-SCAN DMC + ALL PARAMTER REED d22
0- NO ACTION
1- NEW JOB PRESENT
2-REPEAT JOB
4-REJECT JOB
d23
0- NO ACTION
1- JOB PASSED ALL TEST
2- JOB FAIL ANY TEST d24
9999999 d25
9999999 d26
9999999 d27
DMC FULL ( 33 CHAR ) d28
Exp. -000.7396CCM
d29
Exp. REJECT/ ACCPET d30
ST330_SCADA ( DB330) JOB- HEAD
LABEL NAME DATA TYPE ADR. POINT
PLC_SCADA_LINK Word

MACHINE_STS Word

PLC_TO_SCADA Word

SCADA_TO_PLC Word

END_RESULT Word

PASS_CNT DWord
FAIL_CNT DWord
TOTAL_CNT DWord
S_DMC String
S_DMC_RESULT

Word
LT_WATER_RES String
LT_WATER_REM String
LT_OIL_RES String
LT_OIL_REM String
( DB330) JOB- HEAD
DETAILS
1- (PLC WRITE -1 )
0- (SCADA PC WRITE 0 )

0- MACHINE EMG PRESSED


1-HOME OK
2-CYCLE RUNING
3-CYCLE END ( VALUE PRESENT 5 SEC. )

0- NO ACTION
1-SCAN DMC AS REED ( PRE-ASSEMBLY)
2-SCAN DMC AS REED ( POST-ASSEMBLY)
3-SCAN DMC + ALL PARAMTER REED (PRE-ASSEMBLY )
4-SCAN DMC+ALL PARAMETER REED (POST-ASSEMBLY )

0- NO ACTION
1-NEW JOB PRESENT
2-REPEAT JOB
4-REJECT JOB

0- NO ACTION
1- JOB PASSED ALL TEST
2- JOB FAIL ANY TEST
9999999
9999999
9999999
DMC FULL ( 33 CHAR )

0- NO ACTION
1- PRE ASSEMBLY JOB PASS
2- PRE ASSEMBLY JOB NOT FOUND
Exp. -000.7396CCM

Exp. REJECT/ ACCPET


Exp. -000.7396CCM

Exp. REJECT/ ACCPET


ST333_SCADA ( DB333) JOB- HEAD
LABEL NAME DATA TYPE ADR. POINT
PLC_SCADA_LINK Word

MACHINE_STS Word

PLC_TO_SCADA Word

SCADA_TO_PLC Word

END_RESULT Word

PASS_CNT DWord
FAIL_CNT DWord
TOTAL_CNT DWord
S_DMC String
S_DMC_RESULT

Word
LT_VALVE_1_RES String
LT_VALVE_2_RES String
LT_VALVE_3_RES String
LT_VALVE_4_RES String
LT_VALVE_5_RES String
LT_VALVE_6_RES String
LT_VALVE_7_RES String
LT_VALVE_8_RES String
LT_VALVE_9_RES String
LT_VALVE_10_RES String
LT_VALVE_11_RES String
LT_VALVE_12_RES String
LT_VALVE_1_REM String
LT_VALVE_2_REM String
LT_VALVE_3_REM String
LT_VALVE_4_REM String
LT_VALVE_5_REM String
LT_VALVE_6_REM String
LT_VALVE_7_REM String
LT_VALVE_8_REM String
LT_VALVE_9_REM String
LT_VALVE_10_REM String
LT_VALVE_11_REM String
LT_VALVE_12_REM String
( DB333) JOB- HEAD
DETAILS
1- (PLC WRITE -1 )
0- (SCADA PC WRITE 0 )

0- MACHINE EMG PRESSED


1-HOME OK
2-CYCLE RUNING
3-CYCLE END ( VALUE PRESENT 5 SEC. )

0- NO ACTION
1-SCAN DMC AS REED
2-SCAN DMC + ALL PARAMTER REED

0- NO ACTION
1-NEW JOB PRESENT
2-REPEAT JOB
4-REJECT JOB

0- NO ACTION
1- JOB PASSED ALL TEST
2- JOB FAIL ANY TEST
9999999
9999999
9999999
DMC FULL ( 33 CHAR )

0- NO ACTION
1- POST ASSEMBLY JOB PASS
2- POST ASSEMBLY JOB NOT FOUND
Exp. -000.7396CCM
Exp. -000.7396CCM
Exp. -000.7396CCM
Exp. -000.7396CCM
Exp. -000.7396CCM
Exp. -000.7396CCM
Exp. -000.7396CCM
Exp. -000.7396CCM
Exp. -000.7396CCM
Exp. -000.7396CCM
Exp. -000.7396CCM
Exp. -000.7396CCM

Exp. REJECT/ ACCPET


Exp. REJECT/ ACCPET
Exp. REJECT/ ACCPET
Exp. REJECT/ ACCPET
Exp. REJECT/ ACCPET
Exp. REJECT/ ACCPET
Exp. REJECT/ ACCPET
Exp. REJECT/ ACCPET
Exp. REJECT/ ACCPET
Exp. REJECT/ ACCPET
Exp. REJECT/ ACCPET
Exp. REJECT/ ACCPET

You might also like