0% found this document useful (0 votes)
28 views43 pages

PrimeLab2 Catalogue Com

The PrimeLab 2.0 is an advanced photometer designed for water testing, featuring 18 wavelengths for precise readings and a 5.5'' color HD touch display. It offers over 140 parameters, connectivity options including WiFi and Bluetooth, and a built-in camera for scanning QR codes to streamline testing processes. Various starter kits are available to customize the setup according to specific needs, ensuring flexibility and efficiency in water analysis.

Uploaded by

iwan prasetyo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
28 views43 pages

PrimeLab2 Catalogue Com

The PrimeLab 2.0 is an advanced photometer designed for water testing, featuring 18 wavelengths for precise readings and a 5.5'' color HD touch display. It offers over 140 parameters, connectivity options including WiFi and Bluetooth, and a built-in camera for scanning QR codes to streamline testing processes. Various starter kits are available to customize the setup according to specific needs, ensuring flexibility and efficiency in water analysis.

Uploaded by

iwan prasetyo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 43

PrimeLab

The ultimate Photometer


2.0

water testing solutions


made in g ermany
Introduction 6
The PrimeLab 2.0 Explained

PrimeLab 2.0 Starter Kits 8

Table of contents
Kits To Start With

PrimeLab 2.0 Features 12


What Makes This Photometer So Special

18 Wavelength Sensor Technology 14

The PrimeLab 2.0 Display 16


5.5‘‘ Colour–HD Touch Display

Adapters For Different Vials 18


24mm, 16mm And 1ml Semi-Micro-Vials

The PrimeLab 2.0 Camera 20


Available For You Soon!

Connecting The PrimeLab 2.0 22


WiFi, USB & 4G*

LabCOM® 24
The Powerful Software, App and Cloud

3
PrimeLab 2.0 And Probes To Connect 26
pH, EC, TDS, ORP and Temp.

Table of contents
Flexible Parameter Setup | Fairplay 28

PrimeLab 2.0 Pre–Set–Kits 30


Water And Marine

1–Hour–Legionella spp. Test 50

Parameter list 56
More Than 140 Parameters

Accessories And Spares 76

Technical Data 79

Visit our website


www.primelab.org

4 5
PrimeLab introduction
2.0

More than 140 parameters

18 wavelengths (410–940 nm)

5.5" colour HD touch display

Camera (QR–code scanner)

USB Type–C*

WiFi, USB, 4G**, Bluetooth®


The next generation of photometers – the PrimeLab 2.0, Lab 1.0, the PrimeLab 2.0 offers a flexible parameter setup
developed by Water-i.d.® with all the options to upgrade as needed. The PrimeLab 2.0
High-precision readings due to 18 different wavelengths, offers more than 140 different parameters/methods, cover-
Probe–connector (pH|EC|TDS|Temp|ORP) WiFi–USB–Bluetooth®–GSM** connection, powerful soft- ing the needs of many different industries. With its built-in
ware and app, synchronised via a free cloud service, large camera, the PrimeLab 2.0 will offer the ability to scan QR-
HD touch display and the possibility to connect electro- codes to identify sampling points set up by the user and to
des are just some of the features of the new PrimeLab 2.0, identify reagents with the QR-code on the packaging.
which replaces the proven PrimeLab 1.0.
While conventional photometers only perform tests at Advantages of these options are:
selected wavelengths, the Primelab 2.0 can also receive - Scanning the QR-code of a sampling site ensures that you
data from different wavelengths in parallel and thus co- always link the test results you receive to the correct sam-
vers the most important parts of the UV and IR range as pling point. This shortens the testing process as the associa-
Drinking Water well as the entire VIS range. Corresponding LEDs are po- ted sampling point is automatically selected.
sitioned at both 180° and 90° to also allow NTU turbidity, - Scanning QR-codes on reagent packaging prevents the
Laboratories PTSA and fluorescein measurements. Very narrow peaks wrong or even expired reagents from being used and
between 390 and 950 nm enable the most accurate rea- speeds up the testing process by pre-selecting the parame-
Waste Water
dings, close to the performance of a spectrophotometer. ter/method.
Marine
The highly professional PrimeLab 2.0 firmware interpo- In addition, the PrimeLab 2.0 is the ultimate in connectivity!
boiler water lates between the different wavelengths, while some With WiFi–USB–GSM**(via USB modem) there are several
parameter curves are set to use multiple wavelengths to ways to connect the PrimeLab 2.0 to a smartphone, tablet,
Cooling water obtain the most accurate test results. For each method, computer or directly to the LabCOM® cloud.
there are step-by-step instructions in many different lan-
Pools guages as well as useful animations shown on the Prime-
Lab 2.0 screen and links to user videos to ensure that the
Food and beverage correct and proper procedure is followed. Like the Prime-

www.primelab.org *for charging, data transfer, probe connection and 4G** modem **via USB Internet stick | Accessories | possibly subject to a charge for connection

6 7
There are four different starter kits available. The accessories of
each kit build on the Starter Kit 1. This allows you to easily select
the right kit for your required area of application. You can then

Starter add the appropriate reagents and parameters as required. So

Kits
you will simply never need to pay more than you really need!

Starter Kit 1 No parameters/methods activated


PL02B Without reagents

Starter Kit 2 All parameters activated except Turbidity (NTU)|PTSA|Fluorescein


PL02BALL-wo90 Without reagents

Starter Kit 3 All parameters activated


PL02BALL Without reagents

Starter Kit 4 WITH Turbidity (NTU) only


PL02B-TRB Without reagents
No other parameters|methods activated

8 9
PrimeLab 2.0 – Starter Kit accessories

Item-Code Kit

Starter Kit 1 1 x Grey plastic carrying-case with foam insert


PL02B 1 x PrimeLab 2.0 Multitest Photometer
5.5‘‘ HD–Colour-Touch Display
18 wavelengths-scan (410 – 940nm)
„90° ready“ for NTU, PTSA, Fluorescein, Plankton
Option of over 140 different parameters (chargeable activation required)
8.400 mAh Li-Ion-battery (built–in)
Bluetooth® 4.2
WiFi/USB Type C | GSM (via USB-Type-C Modem)
Option to connect Electrodes (via USB Type C plus A/D–changer–Box)
Built-in camera to scan QR-codes
Self-Calibration-Mode with certificate (via LabCOM® software)
„I-OTZ“ Intelligent–One–Time–Zero
Compatible to the free of charge PrimeLab tools:
LabCOM® App| Software|Cloud (Android, iOS, Windows, Mac, Browser)
4 x 24mm|10ml glass-vials with lid (light-shield incorporated into the lid)
1 x Light shield (for 16mm and 1ml vials as well as check-standards)
1 x 24mm vial adapter (built–in; exchangeable)
1 x 10.5 cm stirring rod
1 x 10ml plastic syringe (graduated)
1 x Vial cleaning brush
1 x Microfibre cleaning cloth for vials
1 x Charger with cable (USB–Type–C)
1 x Printed user manual in a ring-binder

Starter Kit 2 Additional To Starter Kit 1


PL02BALL-wo90 1 x 16mm vial adapter
1 x 1ml semi-micro-vials (rectangle) adapter
1 x Luer lock syringe (20ml) with adapter for filter holder
1 x Filteradapter for 20ml Luer-Lock-Spritze
1 x Can with 50 filter-papers GF/C (25mm)
1 x Can with 50 filter-papers 0.4μ (25mm)
1 x 100ml can with lid (for dilution)

Starter Kit 3 Additional To Starter Kit 1


PL02BALL 1 x 16mm vial adapter
1 x 1ml semi-micro-vials (rectangle) adapter
1 x Luer lock syringe (20ml) with adapter for filter holder
1 x Filteradapter for 20ml Luer-Lock-Spritze
1 x Can with 50 filter-papers GF/C (25mm)
1 x Can with 50 filter-papers 0.4μ (25mm)
1 x 100ml can with lid (for dilution)

Starter-Kit 4 Additional To Starter Kit 1


PL02B-TRB 1 x 1 - 10ml professional lab pipette with 2 tips
1 x NTU-Turbidity calibration kit. Sealed glass vials with 0.5/10/1000 NTU
1 x Activation Code ID 112 Turbidity

10 11
Compose your own kit according to your demand and industry. It‘s that easy:

Basic Kit:

1 x PrimeLab 2.0 photometer


Easily exchangeable
1 x Grey plastic case with foam insert
adapter for 24mm, 16mm
4 x 24mm|10ml glass cuvettes
and 1ml semi-micro-
1 x Light protection cap
vials (rectangle)
1 x 10ml syringe
1 x Plastic stirring rod
1 x Cleaning brush
1 x DC adapter (110|220V) with
international plugs & USB cable
1 x Fully printed manual

Extra strong
8400 mAh battery (Available soon!)
for long runtimes Camera for scanning
QR-codes

Parameters:

Select as many parameters/methods as you like from the more than 140 availa-
ble. Don‘t worry about missing a parameter, because you can always purchase a
code to activate more parameters. The PrimeLab software and app are updated
via the internet and always show you the most up-to-date list of available para-
meters so your PrimeLab always stays up to date!

You can view the latest parameter list at www.primelab.org

USB type C port 5.5“ colour


for charging, data HD touch-display
transfer, probe-
connection and Reagents | Accessories:
GSM-modem.
Select reagents according to the selected parameters. Add accessories, e.g.
more cuvettes, stirring rods, professional pipettes, adapters for different cuvette
sizes and much more.

www.primelab.org *via USB Internet stick | Accessories | possibly subject to a charge for connection

12 13
18 wavelength
Sensor Technology
UV – VIS – IR peaks at:
410nm 435nm 460nm 485nm 510nm 535nm

560nm 585nm 610nm 645nm 680nm 705nm

730nm 760nm 810nm 860nm 900nm 940nm

While normal photometers perform tests on one


selected wavelength only, the PrimeLab 2.0 can re-
ceive data from 18 different wavelengths, covering
the key parts of UV and IR section of the spectrum
and the full VIS range.

Three sensors, each with six wavelengths, are inter-


connected together. To enable NTU-Turbidity,
Fluorescein and PTSA measurements, corresponding
LEDs are set up at an angle of 180° as well as 90°. Very
narrow peaks between 390 and 950 nm allow utmost
accurate readings, similar to the performance of a
spectrophotometer.

The highly professional PrimeLab 2.0 firmware can


interpolate between the different wavelength
readings, while some of the parameter curves are set
to use multiple wavelengths to obtain the most ac-
curate test results.
18 wavelengths throughout the UV - VIS - IR range are co-
vered by sensors used by the PrimeLab 2.0. Narrow peaks
on the spectral curve allow utmost accuracy.

www.primelab.org

14 15
5.5'' colour–HD
touch display

5,5"

The PrimeLab 2.0 features a state-of-


the-art 5.5" colour HD touch display.

The large display gives a perfect over-


view of all basic information, such as
battery status, WiFi, 4G* and Bluetooth®
connectivity and offers highest flexibility
for you to arrange icons as you would on
your smartphone.

Each and every parameter/method


comes with step by step instructions in
many different languages plus useful
animations and links to user videos, en-
suring the correct procedure is followed
to get the measurement result accurate
and correct.
Due to the large 5.5" display, all data can
be easily managed on the PrimeLab 2.0.

www.primelab.org

16 17
Adapters for
different vials The PrimeLab 2.0 uses 24mm glass
vials, 16mm glass vials and 1ml
semi-micro-vials (rectangle).

The vial adapter can easily be chan-


ged and replaced with a simple,
built in, bayonet lock. The same
procedure is used for fitting and
replacing each adapter (step 1 – 3).

To remove the adapter again, turn it


anticlockwise and pull it out. Plea-
1ml semi-micro-vial (rectangle)
se make sure to use the lightshield
(e.g. for Legionella testing)
(image on the bottom of the page)
when measuring with the 16mm
16mm
and 1ml semi-micro-vial (rectangle)
(e.g. for COD testing)
adapter.

Step 1: Step 2: Step 3:


Place your chosen adapter in Turn the adapter clockwise un- Please make sure that the rai-
the transparent protective cup til you hear and feel the adapter sed area on the adapter is in
of the smartchamber. Push click into place. line with the traingle*/arrow on
the adapter down to fix it in the PrimeLab 2.0
place.

24mm (standard)

Lightshield for measuring in the


PrimeLab 2.0 with 16mm and 1ml
semi-micro-vials (rectangle)

Check out our


YouTube channel

www.primelab.org

18 19
PrimeLab 2.0
Camera
++ Available soon for you ++

With the built in camera, the PrimeLab point will be selected automatically,
2.0 gives the option to scan QR-codes ready for the next measurement.
to identify sampling points set up by
the user and to identify reagents with 2. Scanning QR-codes from the
QR-codes on the package. The advan- reagent‘s package prevents from
tages of this options are significant: ever using wrong or even expired
reagents, accelerating the test pro-
1. Scanning the QR-code of a sampling cess by pre-selecting the parameter/
point ensures that you always connect method, and being ready for the next
the test results obtained to the right measurement.
sampling point. Rapidly reducing the
test process as the related sampling

www.primelab.org

20 21
Connecting
PrimeLab 2.0
WiFi | USB | 4G* | Bluetooth

Over time, water testing beca- multiple options to connect


me much more than just the PrimeLab 2.0 with a smart-
testing. Real-time availability phone, tablet, computer or di-
of reliable test results plus data rectly with the LabCOM® Cloud.
management are as important
as the test results itself. As said, Wherever the tests are perfor-
the PrimeLab 2.0 is the ultimate med, whether in a lab, on site,
choice for connectivity! on a ship, or in a cooling tower
– in fact anywhere – data can
WiFi, USB (Type C), 4G* and easily and automatically be
Bluetooth® are available as transferred.

www.primelab.org *via USB Internet Stick / accessories / may be subject to costs for connection

22 23
LabCOM ® All f ree of charge!
Software, App & Cloud The most powerful LabCOM® App, Software &
Cloud-solution, developed over many years and
in use with the PrimeLab 1.0 and with the Pool-
Lab®, also connects and runs with the PrimeLab
2.0.

The PrimeLab 2.0 along with the LabCOM® App


and Software allows you to create unlimited
users. In addition you can enter individual water
treatment chemicals. All these are synchronized
via the LabCOM® Cloud. Reports can be created,
printed or sent, dose recommendations can be
created and statistics can be run.

The featured admin tool allows you to create


rules, such as: needs to be tested daily or: test
result must be in between... and gives warnings
when these rules are broken. With the admin
tool, the user also can grant access to other
users, such as customers or headquarters, with
full flexibility to select what information shall be
shared.

The LabCOM® Cloud solution (free of charge) requi-


res less than a minute for registration. It provides full
access to all test results, sampling points and indi-
vidual water treatment chemicals either through
a regular internet browser or on a smartphone
(Android/iOS), tablet or on a computer (Windows/
Mac). Your data is synchronized automatically and
instantly available to review.

The LabCOM® Cloud includes the admin-tool to set


up rules, run statistics and grant access to selected
users.
Once a cloud account is registered (free of charge),
test results, administrator settings, rules and reports
can be managed online: https://labcom.cloud

www.labcom.cloud

24 25
++ Available for you soon ++
PrimeLab 2.0 –
electrodes to connect via a smart box to the PrimeLab 2.0

Item-Code Product Name Description Temp. Rang Range Temp.. Probe

PL2Sp-ElpHPCATC WID pH Lab/Field 312-1 Plastic Body pH Electrode. Designed for general water solutions‘ 0 – 80 °C (0 – 14) pH NTC 30kΩ
pH measurement in scientific research, environmental monitoring,
and quality control. Ideal for both lab and in-field use.
(Not suitable for strong base solution (pH>12), erosive solutions,
or constant testing in high temprature (> 60 °C)). Non refillable.

PL2Sp-ElpHGLATC WID pH Lab/Field 822-1 Routine Sealed Glass Body pH Electrode. Designed for general 0 – 80 °C (0 – 14) pH NTC 30kΩ
water solutions‘ pH measurement in scientific research,
environmental monitoring, and quality control. Ideal for both lab
and in-field use. (Not suitable for strong base solution (pH > 12),
erosive solutions, or constant testing in high temprature (> 60 °C)).
Non refillable.

PL2Sp-ElpHGLrefATC WID pH Lab 324-1 Refillable Glass pH Electrode. Designed for general water 0 – 100 °C (0 – 14) pH NTC 30kΩ
solutions, TRIS Buffer compatible. Suitable applicaitons:
hydroponics, pools and spas,environmental monitoring,
aquaculture, aquariums, education, general purpose labtest,
body fluid, Tris Buffer, Beverage, Wine, Beer, Salt Water, High
Temperature Solutions (up to 100 °C).


PL2Sp-ElORPPCATC WID ORP Lab/Field 422-1 Plastic Body ORP Electrode for faster respond. The gel inner 0 – 80 °C ±2000 mV NO
reference solution does not need to be refilled. This electrode is The PrimeLab 2.0 has the option to connect probes for
designed for testing in general water solutions both in-lab or in-field. testing pH, EC, TDS, Salinity, ORP and Temperature. When
Comes with Φ 0.8*3 mm platinum disc. connecting probes to the PrimeLab 2.0, the photometer
manages the probe, obtaining readings which can be sto-
red under the user-defined sampling points and synchro-
PL2Sp-ElECLRGL WID CON 361-01-1 Glass Body – Pure Water Conductivity Electrode. Conductivity 0 – 80 °C 0 ~ 200 μS/cm NTC 30kΩ nized to the LabCOM®-Cloud (optional).
Electrode (K = 0.1) is designed for purified water and ultra-pure
water conductivity measurements. Electrode size: 7×18 mm platinum. The PrimeLab 2.0 and electrodes connection is made by
a USB-Type C cable with an A/D-exchange-box link. The
PrimeLab 2.0 uses highest quality probes.
PL2Sp-ElECHRGLATC WID CON 351-1-1 Glass Body – Conductivity Electrode (K=1.0). Designed for high– 0 – 80°C 0 – 200 mS/cm NTC 30kΩ
accuracy laboratory conductivity measurements. Its cavity structure
and platinum chip sensor design enhance the accuracy and stability
of conductivity measurement in the range of 0 to 200mS/cm. The
glass body is resistant to all kinds of general chemical corrosion.
Electrode size: 5*7 mm platinum plate/ 2 pole.

PL2Sp-ElECLRPCATC WID CON 341-1-1 Plastic Body – Conductivity Electrode. Designed for high accuracy in 0 – 50°C 0 – 200 mS/cm NTC 30kΩ
a wide range of conductivity measurements (0 to 200 mS/cm). (K = 1.0).

PL2Sp-ElECHRPCATC WID CON 341-10-1 Plastic Body – Conductivity Electrode. Designed for high-range 0 – 80°C 20 – 2000 mS/cm NTC 30kΩ
(K = 10) conductivity measurement . Electrode size: 5*5 mm platinum
ring/ 2 pole.

www.primelab.org

26 27
Flexible
Parameter Setup

Why pay for more parameters than needed?

As with PrimeLab 1.0, the PrimeLab 2.0 is offering a fle- Step 1:


xible parameter setup with all options to upgrade Order the PrimeLab 2.0 Basic Kit in a carrying case
whenever needed. The PrimeLab 2.0 offers more than with device, lightshield, vials, stirring rod, charger,
140 different parameters/methods, covering the needs cleaning brush, microfibre cloth, syringes and full
of many different industries. It is rather unlikely that one printed user manual.
user will be in need of all parameters offered.
Step 2:
That‘s why the PrimeLab 2.0 practices fairplay by giving Choose those parameters/methods from the parame-
the user the option to choose and pay only for those ter‘s list, which shall be pre-activated when the Prime-
parameters they really need. This keeps the costs down Lab 2.0 will be delivered (find the parameter list on p. 56)
to a minimum and makes the PrimeLab 2.0 even more
convenient to use. Even after purchase, the user has the Step 3:
option to activate additional parameters at any time by Find additional acessories, such as additional vials,
just ordering an activation code, to be entered on the pipettes, filter equipment plus reagents according to
PrimeLab 2.0 for instant activation. the parameters selected.

If a PrimeLab 2.0 with all parameters activated is needed Step 4 (optional):


there is two options: Order activation codes (at any time) for additional pa-
1: PrimeLab 2.0 with all parameters activated (PL02BALL) rameters, whenever required. Activate directly on the
OR 2: PrimeLab 2.0 with all parameters activated except PrimeLab 2.0 or through the LabCOM® Software/App.
Turbidity (NTU)|PTSA|Fluorescein (PL02BALL-wo90).

www.primelab.org

28 29
PrimeLab 2.0 The Water-i.d.® PrimeLab 2.0 Pre-set-kits offer

Pre–set–kits complete solutions which include all reagents and


accessories for testing the water according to a
special application.

Combining the accuracy of the PrimeLab 2.0 pho-


tometer with suitable reagents enables the user to
Complete packages including be fully equipped for accurate water testing within
reagents and accessories the framework of the assigned industry.
Each kit can be extended to more than 140 para-
meters at any time by ordering an activation code.

Flexible Parameters,
reagents and accessories
to choose out of the kits

COD Kit 33 Grey Water Control Pro Kit 46


Chemical Oxygen Demand PrimeLab 2.0 Marine

Waste Water Kit 34 SDA Pro Kit 47


PrimeLab 2.0 Marine

Drinking Water Kit 35 SDA Pro Two Kit 48


PrimeLab 2.0 Marine

overview
Boiler Water Kit 37 Cat Fines Control Pro Kit 49
PrimeLab 2.0 Marine

Cooling Water Kit 38 Legionella Basic Kit 52

Pool Water Kit 40 Legionella Professional Kit 54

Cooling Pro Kit 42


PrimeLab 2.0 Marine

PWT Pro Kit 43


PrimeLab 2.0 Marine

Fresh Water Control Kit 44


PrimeLab 2.0 Marine

30 31
Primelab 2.0 COD Kit
(Chemical Oxygen Demand)

Recommended photometer

Item-Code Kit

PL02B The PrimeLab 2.0 Multitest Photometer Starter-Kit contains:


1 x Grey plastic carrying-case with foam insert
1 x PrimeLab 2.0 Multitest Photometer
*Complete accessories and description see on page 9 – 10

Recommended reagents/parameters (these methods are activated on the included PrimeLab 2.0)

Item-Code Parameter Measurement Range Type Of Reagent



PLPar79 COD (LR) 0 – 150 mg/l prepared vials

PLPar80 COD (MR) 0 – 1500 mg/l prepared vials

PLPar17 COD (HR) 0 – 15000 mg/l prepared vials

Can be extended to more than 140 parameters at any time by ordering an activation code.

Recommended accessories

Item-Code Accessories

PLSp-CODheatblock-E Heat block for 8 x 16mm vials. Temp. 70, 100, 120, 150 and 160°C. Digital reading, 110 – 130
V/ 50 – 60 Hz., 220 – 240 V / 50 – 60 Hz, automatic voltage change. 140W

PL2Sp-Adk16 PrimeLab 2.0 adapter to use 16mm glass vials

PLSp-PIP10ml 10ml pipette (variable volume 1 – 10ml)

PLSp-PIP10ml-tips10 10 x tips for PLSp-PIP10ml pipette

PLSp-PIP1ml 1ml pipette (variable volume 0.1 – 1ml)

PLSp-PIP1ml-tips10 10 x tips for PLSp-PIP1ml pipette

32 33
Primelab 2.0 Waste Water Kit Primelab 2.0 Drinking Water Kit

Recommended photometer Recommended photometer

Item-Code Kit Item-Code Kit

PL02B The PrimeLab 2.0 Multitest Photometer Starter-Kit contains: PL02B-TRB The PrimeLab 2.0 Multitest Photometer: Starter-Kit WITH Turbidity (NTU) contains:
1 x Grey plastic carrying-case with foam insert 1 x PrimeLab 2.0 Multitest Photometer
1 x PrimeLab 2.0 Multitest Photometer 1 x Grey plastic carrying-case with foam insert
*Complete accessories and description see on page 9 – 10 1 x 1 – 10ml professional lab pipette with 2 tips
1 x NTU-Turbidity calibration kit. Sealed glass vials with 0.5 / 10 / 1000 NTU
*Complete accessories and description see on page 9 – 10
Recommended reagents/parameters (these methods are activated on the included PrimeLab 2.0)

Item-Code Parameter Measurement Range Type Of Reagent



PLPar155 Ammonia (HR) 1 – 50 mg/l prepared vials + powder Recommended reagents/parameters (these methods are activated on the included PrimeLab 2.0)

PLPar79 COD (LR) 0 – 150 mg/l prepared vials Item-Code Parameter Measurement Range Type Of Reagent

PLPar80 COD (MR) 0 – 1500 mg/l prepared vials PLPar121 Alkalinity-M (HR) 0 – 500 mg/ tablet

PLPar17 COD (HR) 0 – 15000 mg/l prepared vials PLPar6 Alkalinity-P 5 – 300 mg/l tablet

PLPar169 Nitrate (HR) 1 – 100 mg/l powder-liquid PLPar4 Aluminium 0 – 0.3 mg/l tablet

PLPar35 Nitrite (LR) 0 – 0.5 mg/l tablet PLPar7 Boron 0 – 2 mg/l tablet

PLPar152 Nitrogen-Total (HR) 5 – 150 mg/l prepared vials PLPar124 Chloride 0 – 100 mg/l liquid

PLPar45 Phosophate-ortho (LR) 0 – 4 mg/l powder-liquid PLPar11 Chlorine (free-combined-total) 0.00 – 8.00 mg/l tablet

Can be extended to more than 140 parameters at any time by ordering an activation code.
PLPar94 Chromium 0 – 2.2 mg/l tablet

Recommended accessories PLPar107 Colour (Hazen/APHA) 15 – 500 mg/l (Pt-Co) ---

Item-Code Accessories PLPar18 Copper 0 – 5 mg/l tablet

PLSp-CODheatblock-E Heat block for 8 x 16mm vials. Temp. 70, 100, 120, 150 and 160°C. Digital reading, 110 – 130 PLPar158 Cyanide 0.01 – 0.50 mg/l powder-liquid
V/ 50 – 60 Hz., 220 – 240 V / 50 – 60 Hz, automatic voltage change. 140W
PLPar180 Fluoride (SPADNS) 0 – 2 mg/l liquid
PL2Sp-Adk16 PrimeLab 2.0 adapter to use 16mm glass vials


PLSp-PIP10ml 10ml pipette (variable volume 1 – 10ml)
Continued
PLSp-PIP10ml-tips10 10 x tips for PLSp-PIP10ml pipette

PLSp-PIP1ml 1ml pipette (variable volume 0.1 – 1ml)

PLSp-PIP1ml-tips10 10 x tips for PLSp-PIP1ml pipette

34 35
Primelab 2.0 Drinking Water Kit Primelab 2.0 Boiler Water Kit
→ Continued

Recommended reagents/parameters (these methods are activated on the included PrimeLab 2.0) Recommended photometer

Item-Code Parameter Measurement Range Type Of Reagent Item-Code Kit



PLPar56/57 Hardness-Total (LR/HR) 2 (20) – 50 (500) mg/l tablet PL02B The PrimeLab 2.0 Multitest Photometer Starter-Kit contains:
1 x Grey plastic carrying-case with foam insert
PLPar28 Iron (LR) 0 – 1 mg/l tablet 1 x PrimeLab 2.0 Multitest Photometer
*Complete accessories and description see on page 9 – 10
PLPar31 Manganese 0.2 – 5 mg/l tablet

PLPar169 Nitrate (HR) 1 – 100 mg/l powder

Recommended reagents/parameters (these methods are activated on the included PrimeLab 2.0)
PLPar38 pH-value (MR) 6.5 – 8.4 pH tablet
Item-Code Parameter Measurement Range Type Of Reagent
PLPar54 Sulphate 5 – 100 mg/l tablet

PLPar5 Alkalinity-M 5 – 200 mg/l tablet
PLPar112 Turbidity (NTU) 0.5 – 1100 NTU ---
PLPar6 Alkalinity-P 5 – 300 mg/l tablet
PLPar62 Zinc 0 – 1 mg/l tablet
PLPar124 Chloride 0 – 100 mg/l liquid
Can be extended to more than 140 parameters at any time by ordering an activation code.

PLPar56/57 Hardness-Total (LR/HR) 2 (20) – 50 (500) mg/l tablet

PLPar40 pH-value (LR) 5.2 – 6.8 pH tablet


Recommended accessories
PLPar46 Phosphate-ortho 0 – 80 mg/l tablet
Item-Code Accessories
Can be extended to more than 140 parameters at any time by ordering an activation code.
PLSp-InjFil-1 Luer lock syringe (20ml) with adapter for filter holder (PLSp-Filtad1)

PLSp-Filtad1 Filter holder to be attached to PLSp-InjFil-1 / to hold 25mm filter

PLSp-Filt45M 25mm 0.45 micron filter paper. Can of 50 filter papers Recommended accessories

PLSp-PIP10ml-tips10 10 x tips for PLSp-PIP10ml pipette Item-Code Accessories

PL2Sp-Vollpip2ml 2ml bulp-pipette (glass) PLSp-InjFil-1 Luer lock syringe (20ml) with adapter for filter holder (PLSp-Filtad1)

PL2Sp-Vollpip2ml-Ball Pipetting-ball (Peleus ball) for 2ml bulp-pipette PLSp-Filtad1 Filter holder to be attached to PLSp-InjFil-1 / to hold 25mm filter

PLSp-FiltGFC 25mm GF/C filter paper. Can of 50 filter papers

36 37
Primelab 2.0 Cooling Water Kit

Recommended photometer Recommended accessories

Item-Code Kit Item-Code Accessories

PL02B PrimeLab 2.0 Multitest Photometer Starter-Kit contains: PLSp-InjFil-1 Luer lock syringe (20ml) with adapter for filter holder (PLSp-Filtad1)
1 x grey plastic carrying-case with foam insert
1 x PrimeLab 2.0 Multitest Photometer PLSp-Filtad1 Filter holder to be attached to PLSp-InjFil-1 / to hold 25mm filter
*Complete accessories and description see on page 9 – 10
PLSp-Filt45M 25mm 0.45 micron filter paper. Can of 50 filter papers

PLSp-PIP1ml 1ml pipette (variable volume 0.1 – 1ml)

Recommended reagents/parameters (these methods are activated on the included PrimeLab 2.0) PLSp-PIP1ml-tips10 10 x tips for PLSp-PIP1ml pipette

Item-Code Parameter Measurement Range Type Of Reagent PLSp-FiltGFC 25mm GF/C filter papers. Plastic can with 50 filter papers.

PLPar5 Alkalinity-M 5 – 200 mg/l tablet

PLPar8 Bromine 0 – 18 mg/l tablet

PLPar10 Chloride 0.5 – 25 mg/l tablet

PLPar78 Hardness-Calcium 0 – 500 mg/l tablet

PLPar56/57 Hardness-Total (LR/HR) 2 (20) – 50 (500) mg/l tablet

PLPar28 Iron (LR) 0 – 1 mg/l tablet

PLPar30 Iron (HR) 0 – 30 mg/l liquid

PLPar147 Legionella 60 – 1000000 cfu/l liquid

PLPar134 Molybdate (HR) 0 – 40mg/l powder

PLPar35 Nitrite (LR) 0 – 0.5 mg/l tablet

PLPar40 pH-value (LR) 5.2 – 6.8 pH tablet

PLPar41 pH-Universal 5 – 11 pH tablet

PLPar110 Phosphonate 0 – 20 mg/l tablet

Can be extended to more than 140 parameters at any time by ordering an activation code.

Continued

38 39
Primelab 2.0 Pool Water Kit

Recommended photometer

Item-Code Kit Item-Code Parameter Measurement Range Type Of Reagent

PL02B-TRB PrimeLab 2.0 Multitest Photometer: Starter-Kit WITH Turbidity (NTU) contains: PLPar37 Ozone 0 – 5.4 mg/l tablet
1 x PrimeLab 2.0 Multitest Photometer
1 x grey plastic carrying-case with foam insert PLPar38 pH-value (MR) 6.5 – 8.4 tablet
1 x 1 – 10ml professional lab pipette with 2 tips
1 x NTU-Turbidity calibration kit. Sealed glass vials with 0.5 / 10 / 1000 NTU PLPar43 PHMB 2 – 60 mg/l tablet
*Complete accessories and description see on page 9 – 10
PLPar44 Phosphate-ortho (LR) 0 – 4 mg/l tablet

PLPar112 Turbidity (NTU) 0.5 – 1100 NTU ---

Recommended reagents/parameters (these methods are activated on the included PrimeLab 2.0)
PLPar120 Urea 0.1 – 2.5 mg/l tablet + liquid

Item-Code Parameter Measurement Range Type Of Reagent


Can be extended to more than 140 parameters at any time by ordering an activation code.
PLPar1 Active Oxygen 0 – 40 mg/l table

PLPar5 Alkalinity-M 5 – 200 mg/l tablet

PLPar8 Bromine 0 – 18 mg/l tablet


Recommended accessories
PLPar95 Chloramines 0.00 – 8.00 mg/l tablet
Item-Code Accessories
PLPar10 Chloride 0.5 – 25 mg/l tablet
PLSp-InjFil-1 Luer lock syringe (20ml) with adapter for filter holder (PLSp-Filtad1)
PLPar11 Chlorine (free–combined–total) 0.00 – 8.00 mg/l tablet
PLSp-Filtad1 Filter holder to be attached to PLSp-InjFil-1 / to hold 25mm filter
PLPar16 Chlorine Dioxide 0 – 15 mg/l tablet
PLSp-Filt45M 25mm 0.45 micron filter paper. Can of 50 filter papers
PLPar18 Copper 0 – 5 mg/l ---

PLPar20 Cyanuric Acid 2 – 160 mg/l tablet

PLPar78 Hardness–Calcium 0 – 500 mg/ powder-liquid

PLPar148 Hardness–Total (HR) 0 – 500 mg/l liquid

PLPar24 Hydrogen Peroxide (LR) 0 – 3.8 mg/l tablet

PLPar162 Hydrogen Peroxide (HR) 0 – 200 mg/l tablet

PLPar28 Iron (LR) 0 – 1 mg/l tablet

Continued

40 41
PrimeLab 2.0 Marine PrimeLab 2.0 Marine
Cooling Pro Kit PWT Pro Kit

Recommended photometer Recommended set

Item-Code Kit Item-Code Kit

PL02B The PrimeLab 2.0 Multitest Photometer Starter-Kit contains: PL02B-TRB The PrimeLab 2.0 Multitest Photometer: Starter-Kit WITH Turbidity (NTU) contains:
1 x Grey plastic carrying-case with foam insert 1 x PrimeLab 2.0 Multitest Photometer
1 x PrimeLab 2.0 Multitest Photometer 1 x Grey plastic carrying-case with foam insert
*Complete accessories and description see on page 9 – 10 1 x 1 – 10ml professional lab pipette with 2 tips
1 x NTU-Turbidity calibration kit. Sealed glass vials with 0.5 / 10 / 1000 NTU
*Complete accessories and description see on page 9 – 10

Recommended reagents / parameters

Item-Code Parameter Measurement Range Type Of Reagent Recommended reagents / parameters



PLPar5 Alkalinity-M 5 – 200 mg/l Tablets Item-Code Parameter Measurement Range Type Of Reagent

PLPar10 Chloride 0.5 – 25 mg/l Tablets PLPar121 Alkalinity–M (HR) 0 – 500 mg/ Tablets

PLPar78 Hardness-Calcium 0 – 500 mg/l Tablets PLPar6 Alkalinity–P 5 – 300 mg/l Tablets

PLPar56/57 Hardness-Total (LR/HR) 2(20) – 50(500) mg/l Tablets PLPar4 Aluminium 0 – 0.3 mg/l Tablets

WIDmar HSRAEU Legionella 60 – 1000000 cfu/l Test panel, External Test HAT-CHLTest Chloride 30 – 600 mg/l Test strips; External test

PLPar35 Nitrite (LR) 0 – 0.5 mg/l Tablets PLPar11 Chlorine (free-combined-total) 0.00 – 8.00 mg/l Tablets

PLPar40 pH-value (LR) 5.2 – 6.8 pH Tablets PLPar107 Colour (Hazen/APHA) 15 – 500 mg/l (Pt–Co) --

PLPar41 pH-Universal 5 – 11 pH Tablets PLPar18 Copper 0 – 5 mg/l Tablets

Can be extended to more than 140 parameters at any time by ordering an activation code. PLPar56/57 Hardness-Total (LR/HR) 2(20) – 50(500) mg/l Tablets

PLPar28 Iron (LR) 0 – 1 mg/l Tablets

PLPar31 Manganese 0.2 – 5 mg/l Tablets

PLPar169 Nitrate (HR) 1 – 100 mg/l Powder

PLPar38 pH–value (MR) 6.5 – 8.4 pH Tablets

PLPar54 Sulphate 5 – 100 mg/l Tablets

PLPar62 Zinc 0 – 1 mg/l Tablets

Can be extended to more than 140 parameters at any time by ordering an activation code.

42 43
PrimeLab 2.0 Marine
Fresh Water Control Kit

Recommended photometer

Item-Code Kit Item-Code Parameter Measurement Range Type Of Reagent

PL02B-TRB The PrimeLab 2.0 Multitest Photometer: Starter-Kit WITH Turbidity (NTU) contains: PL30DO1/D02/D03 Dissolved Oxygen 0 – 10 mg/l Liquid
1 x PrimeLab 2.0 Multitest Photometer
1 x Grey plastic carrying-case with foam insert TbsPTH50 Hardness-Total (LR/HR) 2 (20) – 50 (500) mg/l Tablet
1 x 1 – 10ml professional lab pipette with 2 tips
1 x NTU-Turbidity calibration kit. Sealed glass vials with 0.5/10/1000 NTU ppFerVer1 Iron total 0 – 3 mg/l Powder
*Complete accessories and description see on page 9 – 10
PPPNiLR50/HR150 Nitrite (LR) 0 – 0.5 mg/l Tablet

TbsPNiHR250 Nitrite (HR) 0 – 1500 mg/l Tablet

Recommended reagents / parameters TbsPpH50 pH-value (MR) 6.4 – 8.4 Tablet

Item-Code Parameter Measurement Range Type Of Reagent


PPHPPLR150/R250 Phosphate-ortho (LR) 0 – 4 mg/l Tablet

IDX-Entero-USA-TDA Bacteria: Enterococci -- Beaker


PL65SiLR1/LR2/LR3 Silica (LR) 0 – 5 mg/l Liquid/powder

BactD006 Bacteria: Pseudomonas species and Coliforms -- Dipslide


TbsPCZ50 Zinc 0 – 1 mg/l Tablet

BactD005 Bacteria: E.coli, Pseudomonas Aeruginosa and -- Dipslide
Total Viable Count (Total Heterotrophic Bacteria)

WIDmar-legio-risk-EU Legionella 100 – 100000 cfu/l Testcard

TbsPTAHR50 Alkalinity-M (HR) 0 – 500 mg/l Tablet

TbsPAP50 Alkalinity-P tablet 5 – 300 mg/l Tablet

PL65Chloride1/2 Chloride 0 – 100 mg/l Liquid

TbsPD150/PD350 Chlorine (free-combined-total) 0.00 – 8.00 mg/l Tablet

- Colour (Hazen/APHA) 15 – 500 mg/l --

TbsHCu150/Cu250 Copper 0 – 5 mg/l Tablet

Can be extended to more than 140 parameters at any time by ordering an activation code.

44 45
PrimeLab 2.0 Marine
Grey Water Control Pro Kit PrimeLab 2.0 Marine SDA Pro Kit

Recommended photometer
Recommended photometer

Item-Code Kit Item-Code Kit

PL02B The PrimeLab 2.0 Multitest Photometer Starter-Kit contains: The PrimeLab 2.0 Multitest Photometer Starter-Kit contains:
PL02Bmar
1 x Grey plastic carrying-case with foam insert 1 x Grey plastic carrying-case with foam insert
1 x PrimeLab 2.0 Multitest Photometer 1 x PrimeLab 2.0 Multitest Photometer
*Complete accessories and description see on page 9 – 10 1 x Direct displacement pipette
10 x Pipette tips 0,1ml [glass, reusable]
5.5‘‘ HD–Colour-Touch Display
16 wavelengths-scan (410 – 940nm)
„90° ready“ for NTU, PTSA, Fluorescein, Plankton
Recommended reagents / parameters Option of over 140 different parameters (chargeable activation required)
8.400 mAh Li-Ion-battery (built–in)
Item-Code Parameter Measurement Range Type Of Reagent Bluetooth® 4.2
WiFi/USB Type C | GSM (via USB-Type-C Modem)
FT6012 pH [electronic meter] 0 – 14 -- Option to connect Electrodes (via USB Type C plus A/D–changer–Box)
Built-in camera to scan QR-codes
FT7021 Conductivity [electronic meter] 0.0 – 2000.0 µS/cm -- Self-Calibration-Mode with certificate (via LabCOM® software)
„I-OTZ“ Intelligent–One–Time–Zero
PLPar155 Ammonia (HR) 1 – 50 mg/l Prepared vials + powder Compatible to the free of charge PrimeLab tools:
LabCOM® App| Software|Cloud (Android, iOS, Windows, Mac, Browser)
PLPar79 COD (LR) 0 – 150 mg/l Prepared vials 4 x 24mm|10ml glass-vials with lid (light-shield incorporated into the lid)
1 x Light shield (for 16mm and 1ml vials as well as check-standards)
PLPar80 COD (MR) 0 – 1500 mg/l Prepared vials 1 x 24mm vial adapter (built–in; exchangeable)
1 x 10.5 cm stirring rod
PLPar17 COD (HR) 0 – 15000 mg/l Prepared vials 1 x 10ml plastic syringe (graduated)
1 x Vial cleaning brush
PLPar169 Nitrate (HR) 1 – 100 mg/l Powder-liquid 1 x Microfibre cleaning cloth for vials
1 x Charger with cable (USB–Type–C)
PLPar35 Nitrite (LR) 0 – 0.5 mg/l Tablet 1 x Printed user manual in a ring-binder

PLPar152 Nitrogen-Total (HR) 5 – 150 mg/l Prepared vials

PLPar45 Phosophate-ortho (LR) 0 – 4 mg/l Powder-liquid


Recommended reagents / parameters
Can be extended to more than 140 parameters at any time by ordering an activation code.
Item-Code Parameter Measurement Range Type Of Reagent

PLPar171 Iron-in-Oil (Fe2+) 20 – 450 mg/l Tablet + Liquid

Can be extended to more than 140 parameters at any time by ordering an activation code.

46 47
PrimeLab 2.0 Marine SDA Pro Two Kit* PrimeLab 2.0 Marine Cat Fines Control Pro Kit*

Recommended photometer Recommended photometer

Item-Code Kit Item-Code Kit

The PrimeLab 2.0 Multitest Photometer Starter-Kit contains:


PL02Bmar PL02Bmar The PrimeLab 2.0 Multitest Photometer Starter-Kit contains:
1 x Grey plastic carrying-case with foam insert 1 x Grey plastic carrying-case with foam insert
1 x PrimeLab 2.0 Multitest Photometer 1 x PrimeLab 2.0 Multitest Photometer
1 x Direct displacement pipette 1 x Direct displacement pipette
10 x Pipette tips 0,1ml [glass, reusable] 10 x Pipette tips 0,1ml [glass, reusable]
5.5‘‘ HD–Colour-Touch Display 5.5‘‘ HD–Colour-Touch Display
16 wavelengths-scan (410 – 940nm) 16 wavelengths-scan (410 – 940nm)
„90° ready“ for NTU, PTSA, Fluorescein, Plankton „90° ready“ for NTU, PTSA, Fluorescein, Plankton
Option of over 140 different parameters (chargeable activation required) Option of over 140 different parameters (chargeable activation required)
8.400 mAh Li-Ion-battery (built–in) 8.400 mAh Li-Ion-battery (built–in)
Bluetooth® 4.2 Bluetooth® 4.2
WiFi/USB Type C | GSM (via USB-Type-C Modem) WiFi/USB Type C | GSM (via USB-Type-C Modem)
Option to connect Electrodes (via USB Type C plus A/D–changer–Box) Option to connect Electrodes (via USB Type C plus A/D–changer–Box)
Built-in camera to scan QR-codes Built-in camera to scan QR-codes
Self-Calibration-Mode with certificate (via LabCOM® software) Self-Calibration-Mode with certificate (via LabCOM® software)
„I-OTZ“ Intelligent–One–Time–Zero „I-OTZ“ Intelligent–One–Time–Zero
Compatible to the free of charge PrimeLab tools: Compatible to the free of charge PrimeLab tools:
LabCOM® App| Software|Cloud (Android, iOS, Windows, Mac, Browser) LabCOM® App| Software|Cloud (Android, iOS, Windows, Mac, Browser)
4 x 24mm|10ml glass-vials with lid (light-shield incorporated into the lid) 4 x 24mm|10ml glass-vials with lid (light-shield incorporated into the lid)
1 x Light shield (for 16mm and 1ml vials as well as check-standards) 1 x Light shield (for 16mm and 1ml vials as well as check-standards)
1 x 24mm vial adapter (built–in; exchangeable) 1 x 24mm vial adapter (built–in; exchangeable)
1 x 10.5 cm stirring rod 1 x 10.5 cm stirring rod
1 x 10ml plastic syringe (graduated) 1 x 10ml plastic syringe (graduated)
1 x Vial cleaning brush 1 x Vial cleaning brush
1 x Microfibre cleaning cloth for vials 1 x Microfibre cleaning cloth for vials
1 x Charger with cable (USB–Type–C) 1 x Charger with cable (USB–Type–C)
1 x Printed user manual in a ring-binder 1 x Printed user manual in a ring-binder

Recommended reagents / parameters Recommended reagents / parameters

Item-Code Parameter Measurement Range Type Of Reagent Item-Code Parameter Measurement Range Type Of Reagent

PLPar171 Iron-in-Oil (Fe2+) 20 – 450 mg/l Tablet + Liquid WIDmar-ALU50 Aluminium-in-Oil 1 – 100 ppm Tablets

PLPar187 Copper-in-Oil 0 – 50 mg/l Tablet + Liquid WIDmar-SIL50 Silica-in-Oil 1 – 100 ppm Powder

Can be extended to more than 140 parameters at any time by ordering an activation code. Can be extended to more than 140 parameters at any time by ordering an activation code.
*Coming soon: Available in II/22 *Available in II/2022

48 49
Legionella Test–Kits
Kit–Features:

1–Hour Legionella spp. Test

Detects only living Legionella

Quantitative 60–106 CFU

AOAC Certified

All–in–one case Water-i.d.® introduces a patented method to test viable Le-


gionella Sp. in just one hour without the need to let bacteria
grow!
Legionella bacteria, in special Legionella pneumorphila se-
rogroup 1, is a harmful threat with a mortality rate of up to
30%. Once Legionella are inhaled (droplets in the air), they
grow in human lungs and can cause Pontiac fever or even
Pneumonia (Legionnaire‘s disease). The issue with current
method (culture) is that it takes up to 14 days to let Legio-
nella grow on a petri dish to be visble and countable, which
is far too long to allow effective actions.

Legipid® on PrimeLab 2.0 takes a different approach: This makes viable Legionella visible (pink colour) to be
As with the culture method, 1 litre of water is filtered to col- detected by the PrimeLab 2.0.
lect the Legionella. After the Legionella are released from The PrimeLab measures the colour and converts it to
the filter, a patented reagent is added that contains micro- 60 – 106 Colony Founding Units (CFU). As the PrimeLab
bits with a magnetic core covered with an antibody. Only is connected via WiFi to a free software and app, both of
living Legionella spp. (no false positives!) are captured by the which are synchronised via the cloud, reporting is very
antibodies. After several washing steps, a colour tracer, also easy.
linked to an antibody, is added, which binds with the Legio-
nella spp. already bound to the micro-bit.

Item-Code Description

LGP-10 Kit to perform max. 9 tests (1 control per batch)

LGP-20 Kit to perform max. 19 tests (1 control per batch)

LGP-40 Kit to perform max. 39 tests (1 control per batch)

LGP-100 Kit to perform max. 99 tests (1 control per batch)

50 51
PrimeLab 2.0 basic legionella kit

Recommended photometer

Item-Code Kit Item-Code Accessories

PL02B The PrimeLab 2.0 Multitest Photometer Starter-Kit contains: PLSp-LG-ELF10 10 x 60 ml Elution Flask
1 x Grey plastic carrying-case with foam insert
1 x PrimeLab 2.0 Multitest Photometer LG-Fil-Prof Professional filter equipment:
*Complete accessories and description see on page 9 – 10 1 x Vacuum pump
1 x filtration funnel
1 x glass collect bottle 1000ml
1 x tweezers
1 x scissor
Recommended reagents / parameters (this method has to be activated on the included PrimeLab 2.0) 10 x elution flasc

Item-Code Parameter LG-Fil-GFC GF/C (Pre-) filter (47mm diameter):


100 x filter papers GF/C for LP-Fil-Prof
PLPar147 ID 147 | Legionella | 60 - 1000000 cfu/l | liquid | Resolution 1
LG-Fil-40M 0.40µ Polycarbonate filter (47mm diameter):
LGP-10 Kit to perform max. 9 tests (1 control / batch): 100 x filter papers 0.40µ for LP-Fil-Prof
1 x bottle (110ml) “L0 Diluent“ *see on next page
10 x single-doses (each 1ml) “L1 Capture Reagent“ LG-Ref-pneu Levertest. Pneumonia positive controll check standard. 20ml. 1 month shelf life
1 x bottle (200ml) “L2 Washing buffer“
10 x single-doses (each 1ml) “L3 Enzyme-labeled anti-Legionella“
5 x tetra dose (each 5ml) “L4 Enzyme-co-substrates“
1 x bottle (2ml) “L5 Stopping reagent“
5 x disposable pipette
10 x 1ml CB cuvette
10 x 9ml MHCB cuvette

Can be extended to more than 140 parameters at any time by ordering an activation code.

Recommended accessories

Item-Code Accessories

LG-MP4-rack 1 x Rack with magnet to hold 4 MHCB cuvettes, to be used as single or with LG-MP4
agitator

LG-MP4-tblcl 1 x table cloth for MP4 to avoid magnet interferences between several MP4 used parallel

PL2Sp-AdkEp PrimeLab 2.0 adapter to use rectangle 1ml Eppendorf-vials

52 53
PrimeLab 2.0 professional legionella kit →
Recommended photometer
Item-Code Accessories
Item-Code Kit
PL2Sp-AluCase-Legi PrimeLab 2.0 aluminium-trolley with foam inserts (matches Legipid filterkit in lower
PL02B The PrimeLab 2.0 Multitest Photometer Starter-Kit contains: compartment)
1 x Grey plastic carrying-case with foam insert
1 x PrimeLab 2.0 Multitest Photometer LG-MP4 „MP4 Multitest agitator - KIT:
*Complete accessories and description see on page 9 – 10 1 x Automatic agitator to place 20 x MHCB cuvettes at a time, which can (1 control / batch)
1 x LG-MP4-AGT multitest agitator
5 x LG-MP4-IHMHCB insertable holder for MHCB cuvettes
5 x LG-MP4-rack magnetic holder for MHCB cuvettes
5 x LG-MP4-BB box bracket
Recommended reagents/parameters (this method has to be activated on the included PrimeLab 2.0) 1 x LG-MP4-TC table cloth
1 x LG-MP4-PLT platform
Item-Code Parameter
PL2Sp-AdkEp PrimeLab 2.0 adapter to use rectangle 1ml Eppendorf-vials
PLPar147 ID 147 | Legionella | 60-1000000 cfu/l | liquid | Resolution 1 PLSp-LG-ELF100 100 x 60 ml Elution Flask
LG-Fil-Prof Professional filter equipment:
LGP-100 „Kit to perform max. 99 tests (1 control / batch): 1 x Vacuum pump *see on next page
1 x bottle (1050ml) “L0 Diluent“ 1 x filtration funnel
1 x bottle (105ml) “L1 Capture Reagent“ 1 x glass collect bottle 1000ml
2 x bottles (each 940ml) „“L2 Washing buffer“ 1 x tweezers
1 x bottle (105ml) “L3 Enzyme-labeled anti-Legionella“ 1 x scissor
35 x tetra dose (each 5ml) „“L4 Enzyme-co-substrates“ 10 x elution flasc
1 x bottle (11ml) “L5 Stopping reagent“
100 x 1ml CB cuvette LG-Fil-GFC GF/C (Pre-) filter (47mm diameter):
100 x 9ml MHCB cuvette 100 x filter papers GF/C for LP-Fil-Prof

Can be extended to more than 140 parameters at any time by ordering an activation code.
LG-Fil-40M 0.40µ Polycarbonate filter (47mm diameter):
100 x filter papers 0.40µ for LP-Fil-Prof

LG-Ref-pneu Levertest. Pneumonia positive controll check standard. 20ml. 1 month shelf life
Recommended accessories

Item-Code Accessories

PLSp-PIP10ml 10ml pipette (variable volume 1-10ml)

PLSp-PIP10ml-tips10 10 x tips for PLSp-PIP10ml pipette


*see on next page
PLSp-PIP1ml 1ml pipette (variable volume 0.1-1ml)

PLSp-PIP1ml-tips10 10 x tips for PLSp-PIP1ml pipette

54 55
PrimeLab 2.0 – List Of Parameters

Parameter Measurement Range Resolution Parameter ID Item-Code Parameter Reagent(s) (No. Of Tests) Type Of Reagent Item-Code Reagents

Active Oxygen (MPS) 0 – 40 mg/l 0.1 01 PLPar1 DPD N°4 Tablet TbsPD4

Alkalinity–M 5 – 200 mg/l 1 05 PLPar5 Alkalinity-M Tablet TbsPTA

Alkalinity–M (HR) 0 – 500 mg/l 1 121 PLPar121 Alkalinity-M-HR Tablet TbsPTAHR

Alkalinity–P 25 – 300 mg/l 1 06 PLPar6 Alkalinity-P Tablet TbsPAP

Aluminium 0 – 0.3 mg/l 0.01 04 PLPar4 Aluminium N°1 Tablet TbsHALM1


Aluminium N°2 Tablet TbsPALM2

Ammonia (LR) 0 – 1 mg/l 0.01 02 PLPar2 Ammonia N°1 Powder Pillow PPHAM1
Ammonia N°2 Powder Pillow PPPAM2
Ammonia Sea-Water cond. Powder Pillow PPHAMsw

Ammonia (HR) 1 – 50 mg/l 0.1 155 PLPar155 50 Ammonia HR vial Kit PL155-kit
50 Ammonia Salicylate F5 Powder Pack
50 Ammonia Cyanurate F5 Powder Pack
100ml deionised water

Boron 0 – 2 mg/l 0.1 07 PLPar7 Boron N°1 (25 tests) Tablet TbsHBO1
Boron N° 2 Tablet TbsPBO2

Bromine 0 – 18 mg/l 0.01 08 PLPar8 DPD N°1 Tablet TbsPD1


Glycine Tablet TbsHGC

Bromine 0 – 18 mg/l 0.01 63 PLPar63 PL DPD 1 A (250/541 tests) Liquid PL30DPD1A/PL65DPD1A


PL DPD 1 B (250/541 tests) Liquid PL30DPD1B/PL65DPD1B
PL DPD Nitrite Powder (285 tests) Powder PLpow20DPDNitr

Bromine 0 – 4.5 mg/l 0.01 128 PLPar128 DPD N°1 Powder Pillow PPPD150

Carbohydrazide 0 – 1.3 mg/l 0.01 71 PLPar71 PL Oxy. Scav. N°1 (270 tests) Liquid PL65OxyScav1
PL Oxy. Scav. N°2 (65 tests) Liquid PL65OxyScav2

Chloramines 0.00 – 8.00 mg/l 0.01 95 PLPar95 DPD N°1 Photometer Tablet TbsPD1
DPD N°2 Photometer Tablet TbsPD2
DPD N°3 Photometer Tablet TbsPD3

Chloride 0.5 – 25 mg/l 0.1 10 PLPar10 Chloride N°1 Tablet TbsHCRD1


Chloride N°2 Tablet TbsPCRD2

Chloride 0 – 100 mg/l 0.1 124 PLPar124 PL Chloride N°1 (108 tests) Liquid PL65Chloride1
PL Chloride N°2 (108 tests) Liquid PL65Chloride2

www.primelab.org

56 57
PrimeLab 2.0 – List Of Parameters

Parameter Measurement Range Resolution Parameter ID Item-Code Parameter Reagent(s) (No. Of Tests) Type Of Reagent Item-Code Reagents

Chloride in Methanol 0 – 20 mg/l 0.01 167 PLPar167 PL30CLMEOH (75 tests) Liquid PL30CLMEOH

Chlorine (fCL, tCl, cCl) 0.00 – 8.00 mg/l 0.01 11 PLPar11 DPD N° 1 Tablet TbsPD1
DPD N° 3 Tablet TbsPD3

Chlorine (fCL, tCl, cCl) 0.00 – 8.00 mg/l 0.01 12 PLPar12 PL DPD 1 A (250/541 tests) Liquid PL30DPD1A/PL65DPD1A
PL DPD 1 B (250/541 tests) Liquid PL30DPD1B/PL65DPD1B
PL DPD 3 C (250/541 tests) Liquid PL30DPD3C/PL65DPD3C

Chlorine (free/combined/total) 0.00 – 8.00 mg/l 0.01 129 PLPar129 DPD N° 1 Powder PPPD150

Chlorine (MR) 0.00 – 10.00 mg/l 0.01 122 PLPar122 DPD N°1 MR Tablet TbsPD1MR
DPD N° 3 MR Tablet TbsPD3MR

Chlorine (HR) 5 – 200 mg/l 1 14 PLPar14 Chlorine HR (Ki) Powder Pillow PPPClHR
Acidifying GP Powder Pillow PPHAFG

Chlorine (HR) 0 – 200 mg/l 1 15 PLPar15 PL Chlorine HR N°1 (541 tests) Liquid PL65ClHR1
PL Chlorine HR N°2 (250/541 tests) Liquid PL30CIHR2/PL65ClHR2

Chlorine Dioxide 0 – 15 mg/l 0.01 16 PLPar16 DPD N°1 Tablet TbsPD1


Glycine Tablet TbsHGC

Chlorine Dioxide 0 – 15 mg/l 0.01 64 PLPar64 PL DPD 1 A (250/541 tests) Liquid PL30DPD1A/PL65DPD1A
PL DPD 1 B (250/541 tests) Liquid PL30DPD1B/PL65DPD1B
PL DPD Glycine (250 tests) Liquid PL30DPDGlycine

Chlorine Dioxide 0 – 5 mg/l 0.01 130 PLPar130 DPD N°1 Powder Pillow PPPD1
Glycine Tablet TbsHGC50

Chlorite 0 – 8 mg/l 0.01 106 PLPar106 PL DPD 1 A (250/541 tests) Liquid PL30DPD1A/PL65DPD1A
PL DPD 1 B (250/541 tests) Liquid PL30DPD1B/PL65DPD1B
PL DPD 3 C (250/541 tests) Liquid PL30DPD3C/PL65DPD3C
PL DPD Glycine (250 tests) Liquid PL30DPDGlycine
PL DPD Acidifying (250 tests) Liquid PL30DPDAcidif
PL DPD Neutralising (250 tests) Liquid PL30DPDNeutr

Chromium 0 – 2.2 mg/l 0.01 94 PLPar94 Chromium N°1 Tablet TbsHChro1


Chromium N°2 Powder Pillow PPPChro2

www.primelab.org

58 59
PrimeLab 2.0 – List Of Parameters

Parameter Measurement Range Resolution Parameter ID Item-Code Parameter Reagent(s) (No. Of Tests) Type Of Reagent Item-Code Reagents

Chromium 0 – 1 mg/l 0.01 103 PLPar103 PL Chromate N°1 (142 tests) Powder PLpow10Chromate1
PL Chromate N°2 (50/108 tests) Liquid PL30-/PL65Chromate2

COD (LR) 0 – 150 mg/l 1 79 PLPar79 25 Prepared vials Vials COD-79-LR

COD (MR) 0 – 1500 mg/l 1 80 PLPar80 25 Prepared vials Vials COD-80-MR

COD (HR) 0 – 15000 mg/l 1 17 PLPar17 25 Prepared vials Vials COD-17-HR

Colour (Hazen/APHA) 15 – 500 mg/l 1 107 PLPar107 -- -- --

Copper 0 – 5 mg/l 0.01 18 PLPar18 Copper N°1 Tablet TbsHCu1


Copper N°2 Tablet TbsPCu2

Copper 0 – 5 mg/l 0.01 19 PLPar19 PL Copper N°1 Powder PLpow20Cu1

Cyanide 0.01 – 0.50 mg/l 0.01 158 PLPar158 PL Cyanide-11 Powder PL158-kit
PL Cyanide-12 Powder
PL Cyanide-13 Liquid

Cyanuric Acid 2 – 160 mg/l 1 20 PLPar20 CYA-Test Tablet TbsPCAT

DBNPA 0 – 13 mg/l 0.01 65 PLPar65 PL DPD 1 A (250/541 tests) Liquid PL30DPD1A/PL65DPD1A


PL DPD 1 B (250/541 tests) Liquid PL30DPD1B/PL65DPD1B
PL DPD 3 C (250/541 tests) Liquid PL30DPD3C/PL65DPD3C

DBNPA 0 – 13 mg/l 0.01 82 PLPar82 DPD N°1 Tablet TbsPD1


DPD N°3 Tablet TbsPD3

DEHA 20 – 1000 µg/l 1.0 21 PLPar21 PL Oxyg. Scav. N°1 (270 tests) Liquid PL65OxyScav1
PL Oxyg. Scav. N°2 (65 tests) Liquid PL65OxyScav2

Dissolved Oxygen 0 – 10 mg/l 0.1 163 PLPar163 PL DissOx N°1 Liquid PL30DO1
PL DissOx N°2 Liquid PL30DO2
PL DissOx N°3 Liquid PL30DO3

Erythorbic Acid 0 – 3.5 mg/l 0.01 70 PLPar70 PL Oxyg. Scav. N°1 (270 tests) Liquid PL65OxyScav1
PL Oxyg. Scav. N°2 (65 tests) Liquid PL65OxyScav2

Fluorescein 0 – 500 µg/l 1 113 PLPar113 -- -- --

Fluoride (SPADNS) 0 – 2 mg/l 0.01 180 PLPar180 PL SPADNS Fluoride (50 tests) Liquid PL100SPADNSF

Hardness–Calcium 0 – 500 mg/l 1 78 PLPar78 Calcium-H. N° 1 Tablet TbsHCH1


Calcium-H. N° 2 Tablet TbsPCH2

www.primelab.org

60 61
PrimeLab 2.0 – List Of Parameters

Parameter Measurement Range Resolution Parameter ID Item-Code Parameter Reagent(s) (No. Of Tests) Type Of Reagent Item-Code Reagents

Hardness–Calcium 0 – 500 mg/l 1 166 PLPar166 PL Calcium Hardness 1 (50 tests) Liquid PL20CH1
PL Calcium Hardness 2(50 tests) Liquid PL20CH2

Hardness–Calcium (HR) 50 – 1000 mg/l 1 09 PLPar9 Calcium Hardness Tablet TbsPCH

Hardness–Total (LR) 2 – 50 mg/l 1 56 PLPar56 Total Hardness Tablet TbsPTH

Hardness–Total (HR) 0 – 500 mg/l 1 148 PLPar148 PL Total Hardness N°1 (50 tests) Liquid PL20TH1
PL Total Hardness N°2 (50 tests) Liquid PL10TH2

Hardness–Total (HR) 20 – 500 mg/l 1 57 PLPar57 Total Hardness Tablet TbsPTH

Hydrazine 5 – 600 µg/l 1 23 PLPar23 PL Hydrazine N°1 (162 tests) Liquid PL65Hydraz1

Hydrocarbons in yes/no 1 160 PLPar160 -- -- --


Methanol (tank wash)

Hydrogen Peroxide (LR) 0 – 3.8 mg/l 0.01 66 PLPar66 PL Hyd. Perox. LR N°1 (250 tests) Liquid PL30HydLRP1
PL Hyd. Perox. LR N°2 (250 tests) Liquid PL30HydLRP2

Hydrogen Peroxide (LR) 0 – 3.8 mg/l 0.01 24 PLPar24 Hydr. Peroxide LR Tablet TbsPHP

Hydrogen Peroxide (HR) 0 – 200 mg/l 1 25 PLPar25 PL Hydr. Perox. HR N°1 (541 tests) Liquid PL65HydHRP1
PL Hydr. Perox. HR N°2 (541 tests) Liquid PL65HydHRP2

Hydrogen Peroxide (HR) 0 – 200 mg/l 1 162 PLPar162 Acidifying PT Photometer Tablet TbsHAFPP
Hydr. Peroxide HR Photometer Powder Pillow PPPHPHR

DEWAN–50 0 – 300 mg/l 1 109 PLPar109 Available via DINAX: www.dinax.hu Liquid PL-DX DEWAN-50

Hydroquinone 0 – 2.5 mg/l 0.01 26 PLPar26 PL Oxygen Scavenger N°1 (270 tests) Liquid PL65OxyScav1
PL Oxygen Scavenger N°2 (65 tests) Liquid PL65OxyScav2

Iodine 0 – 28 mg/l 0.01 27 PLPar27 DPD N°1 Tablet TbsPD1

Iodine 0 – 28 mg/l 0.01 67 PLPar67 PL DPD 1 A (250/541 tests) Liquid PL30DPD1A/PL65DPD1A


PL DPD 1 B (250/541 tests) Liquid PL30DPD1B/PL65DPD1B

Iron (LR) 0 – 1 mg/l 0.01 28 PLPar28 Iron (LR) Tablet TbsPILR

Iron (MR) 0 – 10 mg/l 0.01 29 PLPar29 PL Iron MR N°1 (285 tests) Powder PLpow20IronMR1

Iron (MR) Ferrous 0 – 10 mg/l 0.01 127 PLPar127 PL Iron MR N°2 (400 tests) Powder PLpow20IronMR2

Iron (HR) 0 – 30 mg/l 0.01 30 PLPar30 PL Iron HR N°1 (162/108 tests) Liquid PL65IronHR1
PL Iron HR N°2 (375 tests) Liquid PL30IronHR2

www.primelab.org

62 63
PrimeLab 2.0 – List Of Parameters

Parameter Measurement Range Resolution Parameter ID Item-Code Parameter Reagent(s) (No. Of Tests) Type Of Reagent Item-Code Reagents

Iron total 0 – 3 mg/l 0.01 132 PLPar132 FerroVer® Iron PP (Hach) (100 tests) Powder Pillow ppFerVer1

Iron in Oil 20 – 450 mg/l 1 171 PLPar171 Reagents and accessories kit to perform 60 tests Various PLPar171

Isothiazolinone 0.0 – 10.0 mg/l 0.01 88 PLPar88 PL Isothiazolinone N°1 (187 tests) Liquid PL30Isoz1
PL Isothiazolinone N°2 (108 tests) Liquid PL65Isoz2
PL Isothiazolinone N°3 (95 tests) Liquid PL65Isoz3
PL Isothiazolinone N°4 (108 tests) Liquid PL65Isoz4
PL Isothiazolinone N°5 (150 tests) Liquid PL30Isoz5

Legionella 60 – 106 cfu 1 147 PLPar147 1 x bottle (110ml) „L0 Diluent“ Kit to perform max. 9 tests LGP-10
10 x single-doses (each 1ml) „L1 Capture Reagent“ (1 control / batch):
1 x bottle (200ml) „L2 Washing buffer“
10 x single-doses (each 1ml) „L3 Enzyme-labeled
anti-Legionella“
5 x tetra dose (each 5ml) „L4 Enzyme-co-substrates“
1 x bottle (2ml) „L5 Stopping reagent“
5 x disposable pipette
10 x 1ml CB cuvette
10 x 9ml MHCB cuvette

1 x bottle (210ml) „L0 Diluent“ Kit to perform max. 19 tests LGP-20


1 x bottle (21ml) „L1 Capture Reagent“ (1 control / batch):
1 x bottle (375ml) „L2 Washing buffer“
1 x bottle (21ml) „L3 Enzyme-labeled anti-Legionella“
10 x tetra dose (each 5ml) „L4 Enzyme-co-substrates“
1 x bottle (2.2ml) „L5 Stopping reagent“
20 x 1ml CB cuvette
20 x 9ml MHCB cuvette

1 x bottle (420ml) „L0 Diluent“ Kit to perform max. 39 tests


1 x bottle (42ml) „L1 Capture Reagent“ (1 control / batch): LGP-40
1 x bottle (750ml) „L2 Washing buffer“
1 x bottle (42ml) „L3 Enzyme-labeled anti-Legionella“
15 x tetra dose (each 5ml)“L4 Enzyme-co-substrates“...
.1 x bottle (4.4ml) „L5 Stopping reagent“
40 x 1ml CB cuvette
40 x 9ml MHCB cuvette

1 x bottle (1050ml) „L0 Diluent“ Kit to perform max. 99 tests LGP-100


1 x bottle (42ml) „L1 Capture Reagent“ (1 control / batch):
1 x bottle (105ml)“L1 Capture Reagent“
2 x bottles (each 940ml) „L2 Washing buffer“
1 x bottle (105ml) „L3 Enzyme-labeled anti-Legionella“
35 x tetra dose (each 5ml) „L4 Enzyme-co-substrates“
1 x bottle (11ml) „L5 Stopping reagent“
100 x 1ml CB cuvette
100 x 9ml MHCB cuvette

www.primelab.org

64 65
PrimeLab 2.0 – List Of Parameters

Parameter Measurement Range Resolution Parameter ID Item-Code Parameter Reagent(s) (No. Of Tests) Type Of Reagent Item-Code Reagents

Magnesium 0 – 100 mg/l 1 93 PLPar93 Magnesium Photometer Tablet TbsPMag

Manganese VLR 0 – 0.030 mg/l 0.001 161 PLPar161 Manganese VLR N°1 Tablet TbsHMagVLR1
Manganese VLR N°2 Tablet TbsHMagVLR2

Manganese 0.2 – 5 mg/l 0.1 31 PLPar31 Manganese LR N°1 Powder Pillow PPHMGNSLR1
Manganese LR N°2 Powder Pillow PPPMGNSLR2

Methylethylketoxime 0 – 4.1 mg/l 0.01 69 PLPar69 PL Oxy. Scav. N°1 (270 tests) Liquid PL65OxyScav1
PL Oxy. Scav. N°2 (65 tests) Liquid PL65OxyScav2

Molybdate (LR) 0 – 15 mg/l 0.01 96 PLPar96 Molybdate LR N°1 Tablet TbsHMDL1


Molybdate LR N°2 Tablet TbsPMDL2

Molybdate (HR) 5 – 200 mg/l 0.1 33 PLPar33 PL Molybdate N°1 (162 tests) Liquid PL65Moly1

Molybdate 1 – 100 mg/l 0.1 32 PLPar32 Molybdate HR N°1 Tablet TbsHMDH1


Molybdate HR N°2 Tablet TbsPMDH2

Molybdate (HR) 0 – 40 mg/l 0.1 134 PLPar134 100 Powder-Pillows MolyVer1 in a PE-bag Powder PPPmolyver1
100 Powder-Pillows MolyVer2 in a PE-bag Powder PPPmolyver2
100 Powder-Pillows MolyVer3 in a PE-bag Powder PPPmolyver3

Nickel (HR) 0 – 7 mg/l 0.1 90 PLPar90 Nickel HR N°1 Tablet TbsHNickHR1


Nickel HR N°2 Tablet TbsPNickHR2

Nickel (HR) 0 – 10 mg/l 0.1 100 PLPar100 PL Nickel HR N°1 (100 tests) Liquid PL65NickHR1
PL Nickel HR N°2 (150 tests) Liquid PL30NickHR2
PL Nickel HR N°3 (150 tests) Liquid PL60NickHR3

Nitrate 0.00 – 11.00 mg/l 0.1 34 PLPar34 PL Nitrate N°1 (285 tests) Powder PLpow20Nitra1

Nitrate (HR) 1 – 100 mg/l 1 169 PLPar169 Nitrate HR N° 1 Powder Pillow PPHNitra1
Nitrate HR N° 2 Powder Pillow PPPNitra2

Nitrite (LR) 0 – 0.5 mg/l 0.01 35 PLPar35 Nitrite LR Powder Pillow PPPNiLR

Nitrite (HR) 5 – 200 mg/l 0.1 36 PLPar36 PL Nitrite HR N°1 (142/285 tests) Powder PLpow10-/ PLpow20NitriHR1

Nitrite (HR) 0 – 1500 mg/l 1 97 PLPar97 Nitrite HR N°1 Tablet TbsHNiHR1


Nitrite HR N°2 Tablet TbsPNiHR2

Nitrite (HR) 0 – 3000 mg/l 1 101 PLPar101 PL Nitrite HR N°2 (108 tests) Liquid PL65NitriteHR2

Nitrogen–Total (LR) 0.5 – 25 mg/l 0.1 151 PLPar151 50 Hydrox. LR vials Kit PL151-kit
50 Persulfate powder packs
50 Reagent A powder packs
50 Reagent B powder packs
50 Acid LR/HR vials
100ml DI-Water

www.primelab.org

66 67
PrimeLab 2.0 – List Of Parameters

Parameter Measurement Range Resolution Parameter ID Item-Code Parameter Reagent(s) (No. Of Tests) Type Of Reagent Item-Code Reagents

Nitrogen–Total (HR) 5 – 150 mg/l 1 152 PLPar152 50 Hydrox. HR vials Kit PL152-kit
50 Persulfate powder packs
50 Reagent A powder packs
50 Reagent B powder packs
50 Acid LR/HR vials
100ml DI-Water

Ozone 0 – 5.4 mg/l 0.01 37 PLPar37 DPD N°1 Tablet TbsPD1


DPD N°3 Tablet TbsPD3
Glycine Tablet TbsHGC

Ozone 0 – 5.4 mg/l 0.1 92 PLPar92 PL DPD 1 A (250/541 tests) Liquid PL30DPD1A/PL65DPD1A
PL DPD 1 B (250/541 tests) Liquid PL30DPD1B/PL65DPD1B
PL DPD 3 C (250/541 tests) Liquid PL30DPD3C/PL65DPD3C
PL DPD Glycine (250 tests) Liquid PL30DPDGlycine

Peracetic Acid (LR) 0.00 – 10.00 mg/l 0.01 164 PLPar164 PD N°4 Tablet TbsPD4

Peracetic Acid (HR) 0 – 300 mg/l 1 165 PLPar165 Chlorine HR (KI) Powder Pillow PPPClHR
Acidifying GP Powder Pillow PPHAFG

Permanganate Time Test 0 – 100 %T 0.1 159 PLPar159 PTT (285 tests) Liquid PL10PTT
in Methanol (tank wash) 10ml Reagent grade Methanol Sealed vial PTT-Metha

pH–value (LR) 5.2 – 6.8 pH 0.01 40 PLPar40 Bromocresolpurple Tablet TbsPBRCP

pH–value (MR) 6.5 – 8.4 pH 0.01 38 PLPar38 Phenol Red Tablet TbsPpH

pH–value (MR) 6.4 – 8.4 pH 0.01 39 PLPar39 PL pH 6.4-8.4 (270 tests) Liquid PL65PhenRed

pH–Universal 5 – 11 pH 0.1 41 PLPar41 Universal pH Tablet TbsPUPH

pH–Universal 4 – 11 pH 0.1 42 PLPar42 PL pH 4-11 (162 tests) Liquid PL65UnivpH

Phenol 0 – 5 mg/l 0.01 98 PLPar98 Phenol N°1 Tablet TbsHPhen1


Phenol N°2 Tablet TbsPPhen2
Phenol CR Tablet TbsPPhen3

PHMB 2 – 60 mg/l 1 43 PLPar43 PHMB Tablet TbsPPB

Phosphate–ortho (LR) 0 – 4 mg/l 0.01 44 PLPar44 Phosphate (LR) N°1 Powder Pillow PPHPPLR1
Phosphate (LR) N°2 Tablet TbsPPPLR2

www.primelab.org

68 69
PrimeLab 2.0 – List Of Parameters

Parameter Measurement Range Resolution Parameter ID Item-Code Parameter Reagent(s) (No. Of Tests) Type Of Reagent Item-Code Reagents

Phosohate–ortho (LR) 0 – 4 mg/l 0.01 45 PLPar45 PL Phosphate LR N°1 (65 tests) Liquid PL65PPLR1
PL Phosphate LR N°2 (142/285 tests) Powder PLpow10-/ PLpow20PPLR2

Phosphate–ortho (HR) 0 – 80 mg/l 0.1 46 PLPar46 Phosphate (HR) N°1 Powder Pillow PPHPPHR1
Phosphate (HR) N°2 Tablet TbsPPPHR2

Phosphate–ortho (HR) 0 – 100 mg/l 0.1 47 PLPar47 PL Phosphate HR N°1 (65 tests) Liquid PL65PPHR1
PL Phosphate HR N°2 (65 tests) Liquid PL65PPHR2

Phosphonate 0 – 20 mg/l 0.01 87 PLPar87 PL Phosphonate N°1 (285 tests) Powder PLpow20PPHON1
PL Phosphonate N°2 (285 tests) Powder PLpow20PPHON2
PL Phosphonate N°3 (81 tests) Liquid PL65PPHON3
PL Phosphonate N°4 (285 tests) Powder PLpow20PPHON4

Phosphonate 0 – 20 mg/l 0.01 110 PLPar110 OrgaPhos N°1 Tablet TbsPOPA


OrgaPhos N°2 Tablet TbsPOPB
OrgaPhos N°3 Tablet TbsHOPAX
OrgaPhos-OX Tablet TbsHOXOP

Phosphorus–Total (LR) 0 – 2.6 mg/l 0.01 153 PLPar153 50 Phosphorus LR vial Kit PL153-kit
30ml PL Phosphorus LR N°1
10g PL Phosphorus N°2
100 powder p. Phosphate LR N°1
50 tablets Phosphate LR N°2

Phosphorus–Total (HR) 0 – 52 mg/l 0.1 154 PLPar154 50 Phosphorus HR vial Kit PL154-kit
30ml PL Phosphorus HR N°1
10g PL Phosphorus N°2
100 powder p. Phosphate HR N°1
50 tablets Phosphate HR N°2

Polyacrylate 1 – 30 mg/l 0.1 85 PLPar85 PL Polyacrylate N°1 (65 tests) Liquid PL65PLYA1
PL Polyacrylate N°2 (65 tests) Liquid PL65PLYA2

Potassium 0.7 – 12 mg/l 0.1 48 PLPar48 Potassium Tablet TbsPPTST

PTSA 0 – 1000 µg/l 1 111 PLPar111 -- -- --

QAC 25 – 150 mg/l 1 83 PLPar83 Acidifying GP Powder Pillow PPHAFG


QAC HR Tablet TbsPQAC

Sanosil 0 – 400 mg/l 0.01 173 PLPar173 PL Hydrogen Peroxide HR N°1 Powder PL65HydHRP1
PL Hydrogen Peroxide HR N°2 Powder PL65HydHRP2

www.primelab.org

70 71
PrimeLab 2.0 – List Of Parameters

Parameter Measurement Range Resolution Parameter ID Item-Code Parameter Reagent(s) (No. Of Tests) Type Of Reagent Item-Code Reagents

Silica (LR) 0 – 5 mg/l 0.01 49 PLPar49 PL Silica LR N°1 (162 tests) Liquid PL65SiLR1
PL Silica LR N°2 (162 tests) Liquid PL65SiLR2
PL Silica LR N°3 (190 tests) Powder PLpow40SiLR3

Silica (HR) 0 – 100 mg/l 1 50 PLPar50 PL Silica HR N°1 (71/142 tests) Powder PLpow10-/ PLpow20SilHR1
PL Silica HR N°2 (241 tests) Powder PLpow60SilHR2
PL Silica HR N°3 (142 tests) Powder PLpow10SilHR3

Sodium Hypochlorite 0.2 – 40 % 0.1 51 PLPar51 Chlorine HR (Ki) Powder Pillow PPPClHR
Acidifying GP Powder Pillow PPHAFG

Sodium Hypochlorite 0.2 – 40 % 0.1 68 PLPar68 PL Chlorine HR N°1 (541 tests) Liquid PL65ClHR1
PL Chlorine HR N°2 (250/541 tests) Liquid PL30CIHR2/ PL65ClHR2

Sulphate 5 – 100 mg/l 1 54 PLPar54 Sulphate Powder Pillow PPPSULP

Sulphate 5 – 100 mg/l 1 55 PLPar55 PL Sulphate N°1 (142 tests) Powder PLpow10SULPHA1

Sulphide 0.04 – 0.5 mg/l 0.01 52 PLPar52 Sulphide N°1 Tablet TbsHSULFD1
Sulphide N°2 Tablet TbsPSULFD2

Suphide 0 – 0.7 mg/l 0.01 140 PLPar140 Sulfide 1 (Hach) (1000 tests) Liquid HaSulfide1
Sulfide 2 (Hach) (1000 tests) Liquid HaSulfide2

Sulphite (LR) 0 – 10 mg/l 0.1 53 PLPar53 Sulphite LR Tablet TbsPSULFTLR

Sulphite (HR) 0 – 300 mg/l 0.1 105 PLPar105 Sulphite N°1 Tablet TbsHSULFHR1
Sulphite N°2 Tablet TbsPSULFHR2

Sulphite (HR) 0 – 200 mg/l 0.1 174 PLPar 174 PL Oxygen Scavenger 1 Powder PL65OxyScav1
PL Oxygen Scavenger 2 Powder PL65OxyScav2

Suspended solids 0 – 750 mg/l 1 81 PLPar81 -- -- --

Tannic acid 0 – 150 mg/l 0.1 91 PLPar91 PL Tannin N°1 (65 tests) Liquid PL65Tannin1
PL Tannin N°2 (125 tests) Liquid PL30Tannin2

Tracer 0 – 1000 µg/l 1 157 PLPar157 -- -- --

Total Oxidant 0 – 8 mg/l 0.01 108 PLPar108 PL DPD 1 A (250/541 tests) Liquid PL30DPD1A/PL65DPD1A
PL DPD 1 B (250/541 tests) Liquid PL30DPD1B/PL65DPD1B
PL DPD 3 C (250/541 tests) Liquid PL30DPD3C/PL65DPD3C
PL DPD Acidifying (250 tests) Liquid PL30DPDAcidif
PL DPD Neutralising (250 tests) Liquid PL30DPDNeutr

www.primelab.org

72 73
PrimeLab 2.0 – List Of Parameters

Parameter Measurement Range Resolution Parameter ID Item-Code Parameter Reagent(s) (No. Of Tests) Type Of Reagent Item-Code Reagents

Transmission / 0 – 100 % 0.1 170 PLPar170 -- -- --


Absorption (all wave-
lenghts). Wavelenghts
in nm: 410, 435, 460, 485,
510, 535, 560, 585, 610,
645, 680, 705, 730, 760,
810, 860, 900, 940

Turbidity (FAU) 20 – 1000 FAU 1 59 PLPar59 -- -- --

Turbidity (NTU) 0.5 – 1100 NTU 0.1 112 PLPar112 -- -- --

Urea 0.1 – 2.5 mg/l 0.1 120 PLPar120 Ammonia N°1 Powder Pillow PPHAM1
Ammonia N°2 Powder Pillow PPPAM2
PL Urea N°1 (375 tests) Liquid PL30Urea1
PL Urea N°2 (250 tests) Liquid PL10Urea2

Urea 0.2 – 5.0 mg/l 0.2 150 PLPar150 Ammonia N°1 Powder Pillow PPHAM1
Ammonia N°2 Powder Pillow PPPAM2
PL Urea N°1 (375 tests) Liquid PL30Urea1
PL Urea N°2 (250 tests) Liquid PL10Urea2

Watch Products 0 – 1000 µg/l 1 156 PLPar156 -- -- --

Zinc 0 – 1 mg/l 0.01 62 PLPar62 Copper/Zinc LR Tablet TbsPCZ


EDTA Tablet TbsHED
DECHLOR Tablet TbsHDC

Find the latest parameter list under


https://primelab.org/parameter/list

www.primelab.org

74 75
PrimeLab 2.0 – accessories

Vials and measuring cups Dosing equipment

Item-Code Item Description Item-Code Item Description

PLSp-Kv2410-10 Set of 10 x 24mm (10ml) round glass vials with lid / light shield PLSp-inj1 Graduated Plastic Syringe (10ml)
integrated in lid
PLSp-inj03 Graduated Plastic Syringe (3ml)
PLSp-Kv1610-10 Set of 10 x 16mm (10ml) round glass vials with lid
PLSp-inj01 Graduated Plastic Syringe (1ml)
PLSp-Kv1-100 Set of 100 x 1ml semi-micro-vials (rectangle)
PLSp-PIP10ml 10 ml pipette (variable volume 1 – 10ml)
PLSp-LG-ELF10 Set of 10 x 60ml measuring cup with red lid
PLSp-PIP10ml-tips10 10 x tips for PLSp-PIP10ml pipette
SVZdev100 100ml plastic measuring cup
PLSp-PIP1ml 1 ml pipette (variable volume 0.1 – 1ml)
PLSp-GlsBot50ml 50ml glass-bottle with stopper
PLSp-PIP1ml-tips10 10 x tips for PLSp-PIP1ml pipette

PLSp-PIP01ml 0.1 ml pipette (variable volume 0.01 – 0.1ml)

PLSp-PIP01ml-tips10 10 x tips for PLSp-PIP01ml pipette


Filter utilities
PL2Sp-Vollpip2ml 2ml bulb-pipette (glass)
Item-Code Item Description
PL2Sp-Vollpip2ml-Ball Pipetting-ball (Peleus ball) for 2ml bulb-pipette
PLSp-InjFil-1 Luer lock syringe (20ml) with threat for filter holder

PLSp-Filtad1 Filter holder for PLSp-InjFil-1 luer lock syringe


Heat blocks and electronics
PLSp-FiltGFC 25mm GF/C Filter. Bottle of 50 filter papers
Item-Code Item Description
PLSp-Filt45M 25mm 0.45 µm filter. Bottle of 50 filter papers
PLSp-CODheatblock-E Heat block for 8 x 16mm vials. Temp. 70, 100, 120, 150 and
160°C. Digital reading,
220 – 240 V / 50 – 60 Hz and 110 – 130 V / 50 – 60 Hz, 140W

PLSp-CODheatblock-T Heat block for 12 x 16mm vials. Temp. 70, 100, 120, 148, 150 and 160°C.
Stirring rods / cleaning brushes Heating times: 30 min, 60 min, 90 min, 120 min; 200 – 240 VAC 50Hz;
Maximum 350 W
Item-Code Item Description
PLSp-BltD-1 Bluetooth® USB dongle (to enable Bluetooth® on any Windows–PC)
SPstr10 Set of 10 x 13 cm plastic stirring rods
PLSp2-GSM 4G*–modem (USB–Type–C)
PLSp-str10 Set of 10 x 10.5 cm plastic stirring rods
PLSp2-USBa-c USB–connector (type A to type C)
SPclb10 Set of 10 x 9.5 cm vial-cleaning brushes
PLSp2-USBhuba USB–Hub (Type C and Type A)

PLSp2-USBcable USB–cable (Type A on one end / type C at the other end)

PLSp2-chargeEU PrimeLab 2.0 charger with EU plus

PLSp2-UK/AUS/US UK/AUS/US plug for PrimeLab 2.0 charger

www.primelab.org

76 77
PrimeLab 2.0 – accessories Technical Data

Reference standards Dimensions: 10cm x 25.5cm x 5.9cm (width x length x depth)

Item-Code Item Description Weight: 715g

PL2Sp-Ref112038-f Reference standard kit for PrimeLab IDs 11 (chlorine by tablet), ID Spectral range: 390nm – 950nm
20 (cyanuric acid) and ID 38 (pH by tablet).2 standards for ID 11 18 wavelength, peaks at 410|435|460|485|510|535|560|585|610|645|680|705|730|760|810|860|900
(~0.5 mg/l and ~2 mg/l), 1 standard for ID 20 (~80 mg/l), 1 standard |940nm, 180° and 90° Setup for direct and indirect measurement
for ID 38 (~7.00 pH) as well as a ZERO vial.
In a box with description. 1 year shelf life. Parameters: More than 140 parameters (flexible setup) – User defined parameter function

PL2Sp-Ref122039-f Reference standard kit for PrimeLab IDs 12 (chlorine by liquid), ID 20 Electrodes: USB–type–C connector for pH|EC|TDS|ORP|Temp-Probes
(cyanuric acid) and ID 39 (pH by liquid).
2 standards for ID 12 (~0.5 mg/l and ~2 mg/l), 1 standard for ID 20 Connectivity: WiFi, USB (type C), 4G* (via USB–modem), Bluetooth® 4.2
(~80 mg/l), 1 standard for ID 39 (~7.00 pH) as well as a ZERO vial. (technical)
In a box with description. 1 year shelf life.
Connectivity: LabCOM® Software (Windows | Mac), LabCOM® App (Android | iOS), LabCOM® Cloud (web-
PL2Sp-RefPTSA 3 x Sealed round (24mm) glass-vial (values: 0 µg/l / 100 µg/l / 400 µg/l) (software) browser)

PL2Sp-RefFLSC 2 x 100ml reference standards 100 µg/l Fluorescein, deionized water Display: 5.5‘‘ Colour–HD touch display

PL2Sp-RefTRB 3 x 10ml reference standards 0.5 NTU, 10 NTU, 1000 Camera: (Available soon) In–built QR–code scanner

Calibration: Auto–calibration function with certificate (software)

One-Time-Zero: Intelligent OTZ (One–Time–Zero) function with recognition of ZERO types

Internal memory: >150 000

Other Accessories
Clock/Date: RTC (Real–Time–Clock) with calendar function

Item-Code Item Description


Auto-Off: Factory default setting = 10 minutes. Individual adjustment possible

PLSp2-Ad16/Ad1 PrimeLab 2.0 vial adapter for 16mm glass vials / 1ml semi-micro-vials (rectangle)
Menu guidance: Intuitive, display-controlled 4-button menu guidance; test instructions during measurement
process
PLSp-mft-1 Micro fiber cloth 13x13 cm for PrimeLab vials

Power supply: 8.500 mA Li–Io–battery


PLSp2-carr2 Large PrimeLab 2.0 plastic carrying case

Languages: >4
PLSp2-Alucase Aluminium trolley with foam inserts for PrimeLab 2.0 plus accessories

Environment: 5°C -–45°C | 30 – 90% rel. humidity

Water-proof rating: The device is splash–water–proof (IP54)

Reagents: The calibration curves for the individual parameters|measurement procedures are adjusted to
the reagents offered by Water-i.d.®. Using reagents from other manufacturers may lead to
wrong readings|higher tolerances. PrimeLab reagents are etirely “Made in Germany” or
“Made in UK”!

Ask for our large variety of check-standards (coloured epoxy resin) in sealed 24mm glass vials.

www.primelab.org

78 79
Notes

www.primelab.org

80 81
“When the well‘s dry, we know
the worth of water.“
– Benjamin Franklin

Find us on Find us on Find us on

water_id_ger Water-i.d. GmbH PrimeLab 2.0 Water-i.d. GmbH

82
Headquarters and Production
Water-i.d.® GmbH
Daimlerstr. 20
76344 Eggenstein
Germany
Tel. +49 (0) 721 - 78 20 29 0
Fax. +49 (0) 721 - 78 20 29 11
www.water-id.com
[email protected]

Water-i.d.® UK
Unit 1, Gilchrist Thomas Industrial Estate
Blaenavon, Pontypool, Torfaen
NP4 9RL
Great Britain / UK
www.water-id.com
[email protected]

Water-i.d.® International FZC


Q1/08-31C SAIF Zone
Airport Road, Sharjah
UAE (United Arabian Emirates)
Tel. +971 (0) 50 500 7081
www.water-id.com
[email protected]

Water-i.d.® India Pvt. Ltd.


ANM House, Plot No. A-141
Road No. 23, Wagle Industrial Area
Thane (W) 400604
India
Tel. +91 (0) 22 - 66 14 15 15
Fax +91 (0) 22 - 66 68 16 00
www.water-id.in
[email protected]

Water-i.d.® USA
458 Elizabeth Ave., Suite #5117
Somerset, NJ 08873
USA
Tel. (732) 884-5426
Fax (732) 884-5430
www.water-id.com
[email protected]

Water-i.d.® Russia LLC


Borisovskaya Str., build. 9, office 14a
Moscow, Russian federation
Tel.: +7 909 92 23 28 8
www.water-id.ru
[email protected]

You might also like