PrimeLab2 Catalogue Com
PrimeLab2 Catalogue Com
Table of contents
Kits To Start With
LabCOM® 24
The Powerful Software, App and Cloud
3
PrimeLab 2.0 And Probes To Connect 26
pH, EC, TDS, ORP and Temp.
Table of contents
Flexible Parameter Setup | Fairplay 28
Parameter list 56
More Than 140 Parameters
Technical Data 79
4 5
PrimeLab introduction
2.0
USB Type–C*
www.primelab.org *for charging, data transfer, probe connection and 4G** modem **via USB Internet stick | Accessories | possibly subject to a charge for connection
6 7
There are four different starter kits available. The accessories of
each kit build on the Starter Kit 1. This allows you to easily select
the right kit for your required area of application. You can then
Kits
you will simply never need to pay more than you really need!
8 9
PrimeLab 2.0 – Starter Kit accessories
Item-Code Kit
10 11
Compose your own kit according to your demand and industry. It‘s that easy:
Basic Kit:
Extra strong
8400 mAh battery (Available soon!)
for long runtimes Camera for scanning
QR-codes
Parameters:
Select as many parameters/methods as you like from the more than 140 availa-
ble. Don‘t worry about missing a parameter, because you can always purchase a
code to activate more parameters. The PrimeLab software and app are updated
via the internet and always show you the most up-to-date list of available para-
meters so your PrimeLab always stays up to date!
www.primelab.org *via USB Internet stick | Accessories | possibly subject to a charge for connection
12 13
18 wavelength
Sensor Technology
UV – VIS – IR peaks at:
410nm 435nm 460nm 485nm 510nm 535nm
www.primelab.org
14 15
5.5'' colour–HD
touch display
5,5"
www.primelab.org
16 17
Adapters for
different vials The PrimeLab 2.0 uses 24mm glass
vials, 16mm glass vials and 1ml
semi-micro-vials (rectangle).
24mm (standard)
www.primelab.org
18 19
PrimeLab 2.0
Camera
++ Available soon for you ++
With the built in camera, the PrimeLab point will be selected automatically,
2.0 gives the option to scan QR-codes ready for the next measurement.
to identify sampling points set up by
the user and to identify reagents with 2. Scanning QR-codes from the
QR-codes on the package. The advan- reagent‘s package prevents from
tages of this options are significant: ever using wrong or even expired
reagents, accelerating the test pro-
1. Scanning the QR-code of a sampling cess by pre-selecting the parameter/
point ensures that you always connect method, and being ready for the next
the test results obtained to the right measurement.
sampling point. Rapidly reducing the
test process as the related sampling
www.primelab.org
20 21
Connecting
PrimeLab 2.0
WiFi | USB | 4G* | Bluetooth
www.primelab.org *via USB Internet Stick / accessories / may be subject to costs for connection
22 23
LabCOM ® All f ree of charge!
Software, App & Cloud The most powerful LabCOM® App, Software &
Cloud-solution, developed over many years and
in use with the PrimeLab 1.0 and with the Pool-
Lab®, also connects and runs with the PrimeLab
2.0.
www.labcom.cloud
24 25
++ Available for you soon ++
PrimeLab 2.0 –
electrodes to connect via a smart box to the PrimeLab 2.0
PL2Sp-ElpHPCATC WID pH Lab/Field 312-1 Plastic Body pH Electrode. Designed for general water solutions‘ 0 – 80 °C (0 – 14) pH NTC 30kΩ
pH measurement in scientific research, environmental monitoring,
and quality control. Ideal for both lab and in-field use.
(Not suitable for strong base solution (pH>12), erosive solutions,
or constant testing in high temprature (> 60 °C)). Non refillable.
PL2Sp-ElpHGLATC WID pH Lab/Field 822-1 Routine Sealed Glass Body pH Electrode. Designed for general 0 – 80 °C (0 – 14) pH NTC 30kΩ
water solutions‘ pH measurement in scientific research,
environmental monitoring, and quality control. Ideal for both lab
and in-field use. (Not suitable for strong base solution (pH > 12),
erosive solutions, or constant testing in high temprature (> 60 °C)).
Non refillable.
PL2Sp-ElpHGLrefATC WID pH Lab 324-1 Refillable Glass pH Electrode. Designed for general water 0 – 100 °C (0 – 14) pH NTC 30kΩ
solutions, TRIS Buffer compatible. Suitable applicaitons:
hydroponics, pools and spas,environmental monitoring,
aquaculture, aquariums, education, general purpose labtest,
body fluid, Tris Buffer, Beverage, Wine, Beer, Salt Water, High
Temperature Solutions (up to 100 °C).
PL2Sp-ElORPPCATC WID ORP Lab/Field 422-1 Plastic Body ORP Electrode for faster respond. The gel inner 0 – 80 °C ±2000 mV NO
reference solution does not need to be refilled. This electrode is The PrimeLab 2.0 has the option to connect probes for
designed for testing in general water solutions both in-lab or in-field. testing pH, EC, TDS, Salinity, ORP and Temperature. When
Comes with Φ 0.8*3 mm platinum disc. connecting probes to the PrimeLab 2.0, the photometer
manages the probe, obtaining readings which can be sto-
red under the user-defined sampling points and synchro-
PL2Sp-ElECLRGL WID CON 361-01-1 Glass Body – Pure Water Conductivity Electrode. Conductivity 0 – 80 °C 0 ~ 200 μS/cm NTC 30kΩ nized to the LabCOM®-Cloud (optional).
Electrode (K = 0.1) is designed for purified water and ultra-pure
water conductivity measurements. Electrode size: 7×18 mm platinum. The PrimeLab 2.0 and electrodes connection is made by
a USB-Type C cable with an A/D-exchange-box link. The
PrimeLab 2.0 uses highest quality probes.
PL2Sp-ElECHRGLATC WID CON 351-1-1 Glass Body – Conductivity Electrode (K=1.0). Designed for high– 0 – 80°C 0 – 200 mS/cm NTC 30kΩ
accuracy laboratory conductivity measurements. Its cavity structure
and platinum chip sensor design enhance the accuracy and stability
of conductivity measurement in the range of 0 to 200mS/cm. The
glass body is resistant to all kinds of general chemical corrosion.
Electrode size: 5*7 mm platinum plate/ 2 pole.
PL2Sp-ElECLRPCATC WID CON 341-1-1 Plastic Body – Conductivity Electrode. Designed for high accuracy in 0 – 50°C 0 – 200 mS/cm NTC 30kΩ
a wide range of conductivity measurements (0 to 200 mS/cm). (K = 1.0).
PL2Sp-ElECHRPCATC WID CON 341-10-1 Plastic Body – Conductivity Electrode. Designed for high-range 0 – 80°C 20 – 2000 mS/cm NTC 30kΩ
(K = 10) conductivity measurement . Electrode size: 5*5 mm platinum
ring/ 2 pole.
www.primelab.org
26 27
Flexible
Parameter Setup
www.primelab.org
28 29
PrimeLab 2.0 The Water-i.d.® PrimeLab 2.0 Pre-set-kits offer
Flexible Parameters,
reagents and accessories
to choose out of the kits
overview
Boiler Water Kit 37 Cat Fines Control Pro Kit 49
PrimeLab 2.0 Marine
30 31
Primelab 2.0 COD Kit
(Chemical Oxygen Demand)
Recommended photometer
Item-Code Kit
Recommended reagents/parameters (these methods are activated on the included PrimeLab 2.0)
Can be extended to more than 140 parameters at any time by ordering an activation code.
Recommended accessories
Item-Code Accessories
PLSp-CODheatblock-E Heat block for 8 x 16mm vials. Temp. 70, 100, 120, 150 and 160°C. Digital reading, 110 – 130
V/ 50 – 60 Hz., 220 – 240 V / 50 – 60 Hz, automatic voltage change. 140W
32 33
Primelab 2.0 Waste Water Kit Primelab 2.0 Drinking Water Kit
PL02B The PrimeLab 2.0 Multitest Photometer Starter-Kit contains: PL02B-TRB The PrimeLab 2.0 Multitest Photometer: Starter-Kit WITH Turbidity (NTU) contains:
1 x Grey plastic carrying-case with foam insert 1 x PrimeLab 2.0 Multitest Photometer
1 x PrimeLab 2.0 Multitest Photometer 1 x Grey plastic carrying-case with foam insert
*Complete accessories and description see on page 9 – 10 1 x 1 – 10ml professional lab pipette with 2 tips
1 x NTU-Turbidity calibration kit. Sealed glass vials with 0.5 / 10 / 1000 NTU
*Complete accessories and description see on page 9 – 10
Recommended reagents/parameters (these methods are activated on the included PrimeLab 2.0)
PLPar79 COD (LR) 0 – 150 mg/l prepared vials Item-Code Parameter Measurement Range Type Of Reagent
PLPar80 COD (MR) 0 – 1500 mg/l prepared vials PLPar121 Alkalinity-M (HR) 0 – 500 mg/ tablet
PLPar17 COD (HR) 0 – 15000 mg/l prepared vials PLPar6 Alkalinity-P 5 – 300 mg/l tablet
PLPar169 Nitrate (HR) 1 – 100 mg/l powder-liquid PLPar4 Aluminium 0 – 0.3 mg/l tablet
PLPar35 Nitrite (LR) 0 – 0.5 mg/l tablet PLPar7 Boron 0 – 2 mg/l tablet
PLPar152 Nitrogen-Total (HR) 5 – 150 mg/l prepared vials PLPar124 Chloride 0 – 100 mg/l liquid
PLPar45 Phosophate-ortho (LR) 0 – 4 mg/l powder-liquid PLPar11 Chlorine (free-combined-total) 0.00 – 8.00 mg/l tablet
Can be extended to more than 140 parameters at any time by ordering an activation code.
PLPar94 Chromium 0 – 2.2 mg/l tablet
PLSp-CODheatblock-E Heat block for 8 x 16mm vials. Temp. 70, 100, 120, 150 and 160°C. Digital reading, 110 – 130 PLPar158 Cyanide 0.01 – 0.50 mg/l powder-liquid
V/ 50 – 60 Hz., 220 – 240 V / 50 – 60 Hz, automatic voltage change. 140W
PLPar180 Fluoride (SPADNS) 0 – 2 mg/l liquid
PL2Sp-Adk16 PrimeLab 2.0 adapter to use 16mm glass vials
→
PLSp-PIP10ml 10ml pipette (variable volume 1 – 10ml)
Continued
PLSp-PIP10ml-tips10 10 x tips for PLSp-PIP10ml pipette
34 35
Primelab 2.0 Drinking Water Kit Primelab 2.0 Boiler Water Kit
→ Continued
Recommended reagents/parameters (these methods are activated on the included PrimeLab 2.0) Recommended photometer
Recommended reagents/parameters (these methods are activated on the included PrimeLab 2.0)
PLPar38 pH-value (MR) 6.5 – 8.4 pH tablet
Item-Code Parameter Measurement Range Type Of Reagent
PLPar54 Sulphate 5 – 100 mg/l tablet
PLPar5 Alkalinity-M 5 – 200 mg/l tablet
PLPar112 Turbidity (NTU) 0.5 – 1100 NTU ---
PLPar6 Alkalinity-P 5 – 300 mg/l tablet
PLPar62 Zinc 0 – 1 mg/l tablet
PLPar124 Chloride 0 – 100 mg/l liquid
Can be extended to more than 140 parameters at any time by ordering an activation code.
PLSp-Filt45M 25mm 0.45 micron filter paper. Can of 50 filter papers Recommended accessories
PL2Sp-Vollpip2ml 2ml bulp-pipette (glass) PLSp-InjFil-1 Luer lock syringe (20ml) with adapter for filter holder (PLSp-Filtad1)
PL2Sp-Vollpip2ml-Ball Pipetting-ball (Peleus ball) for 2ml bulp-pipette PLSp-Filtad1 Filter holder to be attached to PLSp-InjFil-1 / to hold 25mm filter
36 37
Primelab 2.0 Cooling Water Kit
PL02B PrimeLab 2.0 Multitest Photometer Starter-Kit contains: PLSp-InjFil-1 Luer lock syringe (20ml) with adapter for filter holder (PLSp-Filtad1)
1 x grey plastic carrying-case with foam insert
1 x PrimeLab 2.0 Multitest Photometer PLSp-Filtad1 Filter holder to be attached to PLSp-InjFil-1 / to hold 25mm filter
*Complete accessories and description see on page 9 – 10
PLSp-Filt45M 25mm 0.45 micron filter paper. Can of 50 filter papers
Recommended reagents/parameters (these methods are activated on the included PrimeLab 2.0) PLSp-PIP1ml-tips10 10 x tips for PLSp-PIP1ml pipette
Item-Code Parameter Measurement Range Type Of Reagent PLSp-FiltGFC 25mm GF/C filter papers. Plastic can with 50 filter papers.
PLPar5 Alkalinity-M 5 – 200 mg/l tablet
Can be extended to more than 140 parameters at any time by ordering an activation code.
Continued
→
38 39
Primelab 2.0 Pool Water Kit
Recommended photometer
PL02B-TRB PrimeLab 2.0 Multitest Photometer: Starter-Kit WITH Turbidity (NTU) contains: PLPar37 Ozone 0 – 5.4 mg/l tablet
1 x PrimeLab 2.0 Multitest Photometer
1 x grey plastic carrying-case with foam insert PLPar38 pH-value (MR) 6.5 – 8.4 tablet
1 x 1 – 10ml professional lab pipette with 2 tips
1 x NTU-Turbidity calibration kit. Sealed glass vials with 0.5 / 10 / 1000 NTU PLPar43 PHMB 2 – 60 mg/l tablet
*Complete accessories and description see on page 9 – 10
PLPar44 Phosphate-ortho (LR) 0 – 4 mg/l tablet
Recommended reagents/parameters (these methods are activated on the included PrimeLab 2.0)
PLPar120 Urea 0.1 – 2.5 mg/l tablet + liquid
Continued
→
40 41
PrimeLab 2.0 Marine PrimeLab 2.0 Marine
Cooling Pro Kit PWT Pro Kit
PL02B The PrimeLab 2.0 Multitest Photometer Starter-Kit contains: PL02B-TRB The PrimeLab 2.0 Multitest Photometer: Starter-Kit WITH Turbidity (NTU) contains:
1 x Grey plastic carrying-case with foam insert 1 x PrimeLab 2.0 Multitest Photometer
1 x PrimeLab 2.0 Multitest Photometer 1 x Grey plastic carrying-case with foam insert
*Complete accessories and description see on page 9 – 10 1 x 1 – 10ml professional lab pipette with 2 tips
1 x NTU-Turbidity calibration kit. Sealed glass vials with 0.5 / 10 / 1000 NTU
*Complete accessories and description see on page 9 – 10
PLPar78 Hardness-Calcium 0 – 500 mg/l Tablets PLPar6 Alkalinity–P 5 – 300 mg/l Tablets
PLPar56/57 Hardness-Total (LR/HR) 2(20) – 50(500) mg/l Tablets PLPar4 Aluminium 0 – 0.3 mg/l Tablets
WIDmar HSRAEU Legionella 60 – 1000000 cfu/l Test panel, External Test HAT-CHLTest Chloride 30 – 600 mg/l Test strips; External test
PLPar35 Nitrite (LR) 0 – 0.5 mg/l Tablets PLPar11 Chlorine (free-combined-total) 0.00 – 8.00 mg/l Tablets
PLPar40 pH-value (LR) 5.2 – 6.8 pH Tablets PLPar107 Colour (Hazen/APHA) 15 – 500 mg/l (Pt–Co) --
Can be extended to more than 140 parameters at any time by ordering an activation code. PLPar56/57 Hardness-Total (LR/HR) 2(20) – 50(500) mg/l Tablets
Can be extended to more than 140 parameters at any time by ordering an activation code.
42 43
PrimeLab 2.0 Marine
Fresh Water Control Kit
→
Recommended photometer
PL02B-TRB The PrimeLab 2.0 Multitest Photometer: Starter-Kit WITH Turbidity (NTU) contains: PL30DO1/D02/D03 Dissolved Oxygen 0 – 10 mg/l Liquid
1 x PrimeLab 2.0 Multitest Photometer
1 x Grey plastic carrying-case with foam insert TbsPTH50 Hardness-Total (LR/HR) 2 (20) – 50 (500) mg/l Tablet
1 x 1 – 10ml professional lab pipette with 2 tips
1 x NTU-Turbidity calibration kit. Sealed glass vials with 0.5/10/1000 NTU ppFerVer1 Iron total 0 – 3 mg/l Powder
*Complete accessories and description see on page 9 – 10
PPPNiLR50/HR150 Nitrite (LR) 0 – 0.5 mg/l Tablet
Can be extended to more than 140 parameters at any time by ordering an activation code.
44 45
PrimeLab 2.0 Marine
Grey Water Control Pro Kit PrimeLab 2.0 Marine SDA Pro Kit
Recommended photometer
Recommended photometer
PL02B The PrimeLab 2.0 Multitest Photometer Starter-Kit contains: The PrimeLab 2.0 Multitest Photometer Starter-Kit contains:
PL02Bmar
1 x Grey plastic carrying-case with foam insert 1 x Grey plastic carrying-case with foam insert
1 x PrimeLab 2.0 Multitest Photometer 1 x PrimeLab 2.0 Multitest Photometer
*Complete accessories and description see on page 9 – 10 1 x Direct displacement pipette
10 x Pipette tips 0,1ml [glass, reusable]
5.5‘‘ HD–Colour-Touch Display
16 wavelengths-scan (410 – 940nm)
„90° ready“ for NTU, PTSA, Fluorescein, Plankton
Recommended reagents / parameters Option of over 140 different parameters (chargeable activation required)
8.400 mAh Li-Ion-battery (built–in)
Item-Code Parameter Measurement Range Type Of Reagent Bluetooth® 4.2
WiFi/USB Type C | GSM (via USB-Type-C Modem)
FT6012 pH [electronic meter] 0 – 14 -- Option to connect Electrodes (via USB Type C plus A/D–changer–Box)
Built-in camera to scan QR-codes
FT7021 Conductivity [electronic meter] 0.0 – 2000.0 µS/cm -- Self-Calibration-Mode with certificate (via LabCOM® software)
„I-OTZ“ Intelligent–One–Time–Zero
PLPar155 Ammonia (HR) 1 – 50 mg/l Prepared vials + powder Compatible to the free of charge PrimeLab tools:
LabCOM® App| Software|Cloud (Android, iOS, Windows, Mac, Browser)
PLPar79 COD (LR) 0 – 150 mg/l Prepared vials 4 x 24mm|10ml glass-vials with lid (light-shield incorporated into the lid)
1 x Light shield (for 16mm and 1ml vials as well as check-standards)
PLPar80 COD (MR) 0 – 1500 mg/l Prepared vials 1 x 24mm vial adapter (built–in; exchangeable)
1 x 10.5 cm stirring rod
PLPar17 COD (HR) 0 – 15000 mg/l Prepared vials 1 x 10ml plastic syringe (graduated)
1 x Vial cleaning brush
PLPar169 Nitrate (HR) 1 – 100 mg/l Powder-liquid 1 x Microfibre cleaning cloth for vials
1 x Charger with cable (USB–Type–C)
PLPar35 Nitrite (LR) 0 – 0.5 mg/l Tablet 1 x Printed user manual in a ring-binder
Can be extended to more than 140 parameters at any time by ordering an activation code.
46 47
PrimeLab 2.0 Marine SDA Pro Two Kit* PrimeLab 2.0 Marine Cat Fines Control Pro Kit*
Item-Code Parameter Measurement Range Type Of Reagent Item-Code Parameter Measurement Range Type Of Reagent
PLPar171 Iron-in-Oil (Fe2+) 20 – 450 mg/l Tablet + Liquid WIDmar-ALU50 Aluminium-in-Oil 1 – 100 ppm Tablets
PLPar187 Copper-in-Oil 0 – 50 mg/l Tablet + Liquid WIDmar-SIL50 Silica-in-Oil 1 – 100 ppm Powder
Can be extended to more than 140 parameters at any time by ordering an activation code. Can be extended to more than 140 parameters at any time by ordering an activation code.
*Coming soon: Available in II/22 *Available in II/2022
48 49
Legionella Test–Kits
Kit–Features:
AOAC Certified
Legipid® on PrimeLab 2.0 takes a different approach: This makes viable Legionella visible (pink colour) to be
As with the culture method, 1 litre of water is filtered to col- detected by the PrimeLab 2.0.
lect the Legionella. After the Legionella are released from The PrimeLab measures the colour and converts it to
the filter, a patented reagent is added that contains micro- 60 – 106 Colony Founding Units (CFU). As the PrimeLab
bits with a magnetic core covered with an antibody. Only is connected via WiFi to a free software and app, both of
living Legionella spp. (no false positives!) are captured by the which are synchronised via the cloud, reporting is very
antibodies. After several washing steps, a colour tracer, also easy.
linked to an antibody, is added, which binds with the Legio-
nella spp. already bound to the micro-bit.
Item-Code Description
50 51
PrimeLab 2.0 basic legionella kit
→
Recommended photometer
PL02B The PrimeLab 2.0 Multitest Photometer Starter-Kit contains: PLSp-LG-ELF10 10 x 60 ml Elution Flask
1 x Grey plastic carrying-case with foam insert
1 x PrimeLab 2.0 Multitest Photometer LG-Fil-Prof Professional filter equipment:
*Complete accessories and description see on page 9 – 10 1 x Vacuum pump
1 x filtration funnel
1 x glass collect bottle 1000ml
1 x tweezers
1 x scissor
Recommended reagents / parameters (this method has to be activated on the included PrimeLab 2.0) 10 x elution flasc
Can be extended to more than 140 parameters at any time by ordering an activation code.
Recommended accessories
Item-Code Accessories
LG-MP4-rack 1 x Rack with magnet to hold 4 MHCB cuvettes, to be used as single or with LG-MP4
agitator
LG-MP4-tblcl 1 x table cloth for MP4 to avoid magnet interferences between several MP4 used parallel
52 53
PrimeLab 2.0 professional legionella kit →
Recommended photometer
Item-Code Accessories
Item-Code Kit
PL2Sp-AluCase-Legi PrimeLab 2.0 aluminium-trolley with foam inserts (matches Legipid filterkit in lower
PL02B The PrimeLab 2.0 Multitest Photometer Starter-Kit contains: compartment)
1 x Grey plastic carrying-case with foam insert
1 x PrimeLab 2.0 Multitest Photometer LG-MP4 „MP4 Multitest agitator - KIT:
*Complete accessories and description see on page 9 – 10 1 x Automatic agitator to place 20 x MHCB cuvettes at a time, which can (1 control / batch)
1 x LG-MP4-AGT multitest agitator
5 x LG-MP4-IHMHCB insertable holder for MHCB cuvettes
5 x LG-MP4-rack magnetic holder for MHCB cuvettes
5 x LG-MP4-BB box bracket
Recommended reagents/parameters (this method has to be activated on the included PrimeLab 2.0) 1 x LG-MP4-TC table cloth
1 x LG-MP4-PLT platform
Item-Code Parameter
PL2Sp-AdkEp PrimeLab 2.0 adapter to use rectangle 1ml Eppendorf-vials
PLPar147 ID 147 | Legionella | 60-1000000 cfu/l | liquid | Resolution 1 PLSp-LG-ELF100 100 x 60 ml Elution Flask
LG-Fil-Prof Professional filter equipment:
LGP-100 „Kit to perform max. 99 tests (1 control / batch): 1 x Vacuum pump *see on next page
1 x bottle (1050ml) “L0 Diluent“ 1 x filtration funnel
1 x bottle (105ml) “L1 Capture Reagent“ 1 x glass collect bottle 1000ml
2 x bottles (each 940ml) „“L2 Washing buffer“ 1 x tweezers
1 x bottle (105ml) “L3 Enzyme-labeled anti-Legionella“ 1 x scissor
35 x tetra dose (each 5ml) „“L4 Enzyme-co-substrates“ 10 x elution flasc
1 x bottle (11ml) “L5 Stopping reagent“
100 x 1ml CB cuvette LG-Fil-GFC GF/C (Pre-) filter (47mm diameter):
100 x 9ml MHCB cuvette 100 x filter papers GF/C for LP-Fil-Prof
Can be extended to more than 140 parameters at any time by ordering an activation code.
LG-Fil-40M 0.40µ Polycarbonate filter (47mm diameter):
100 x filter papers 0.40µ for LP-Fil-Prof
LG-Ref-pneu Levertest. Pneumonia positive controll check standard. 20ml. 1 month shelf life
Recommended accessories
Item-Code Accessories
54 55
PrimeLab 2.0 – List Of Parameters
Parameter Measurement Range Resolution Parameter ID Item-Code Parameter Reagent(s) (No. Of Tests) Type Of Reagent Item-Code Reagents
Active Oxygen (MPS) 0 – 40 mg/l 0.1 01 PLPar1 DPD N°4 Tablet TbsPD4
Ammonia (LR) 0 – 1 mg/l 0.01 02 PLPar2 Ammonia N°1 Powder Pillow PPHAM1
Ammonia N°2 Powder Pillow PPPAM2
Ammonia Sea-Water cond. Powder Pillow PPHAMsw
Ammonia (HR) 1 – 50 mg/l 0.1 155 PLPar155 50 Ammonia HR vial Kit PL155-kit
50 Ammonia Salicylate F5 Powder Pack
50 Ammonia Cyanurate F5 Powder Pack
100ml deionised water
Boron 0 – 2 mg/l 0.1 07 PLPar7 Boron N°1 (25 tests) Tablet TbsHBO1
Boron N° 2 Tablet TbsPBO2
Bromine 0 – 4.5 mg/l 0.01 128 PLPar128 DPD N°1 Powder Pillow PPPD150
Carbohydrazide 0 – 1.3 mg/l 0.01 71 PLPar71 PL Oxy. Scav. N°1 (270 tests) Liquid PL65OxyScav1
PL Oxy. Scav. N°2 (65 tests) Liquid PL65OxyScav2
Chloramines 0.00 – 8.00 mg/l 0.01 95 PLPar95 DPD N°1 Photometer Tablet TbsPD1
DPD N°2 Photometer Tablet TbsPD2
DPD N°3 Photometer Tablet TbsPD3
Chloride 0 – 100 mg/l 0.1 124 PLPar124 PL Chloride N°1 (108 tests) Liquid PL65Chloride1
PL Chloride N°2 (108 tests) Liquid PL65Chloride2
www.primelab.org
56 57
PrimeLab 2.0 – List Of Parameters
Parameter Measurement Range Resolution Parameter ID Item-Code Parameter Reagent(s) (No. Of Tests) Type Of Reagent Item-Code Reagents
Chloride in Methanol 0 – 20 mg/l 0.01 167 PLPar167 PL30CLMEOH (75 tests) Liquid PL30CLMEOH
Chlorine (fCL, tCl, cCl) 0.00 – 8.00 mg/l 0.01 11 PLPar11 DPD N° 1 Tablet TbsPD1
DPD N° 3 Tablet TbsPD3
Chlorine (fCL, tCl, cCl) 0.00 – 8.00 mg/l 0.01 12 PLPar12 PL DPD 1 A (250/541 tests) Liquid PL30DPD1A/PL65DPD1A
PL DPD 1 B (250/541 tests) Liquid PL30DPD1B/PL65DPD1B
PL DPD 3 C (250/541 tests) Liquid PL30DPD3C/PL65DPD3C
Chlorine (free/combined/total) 0.00 – 8.00 mg/l 0.01 129 PLPar129 DPD N° 1 Powder PPPD150
Chlorine (MR) 0.00 – 10.00 mg/l 0.01 122 PLPar122 DPD N°1 MR Tablet TbsPD1MR
DPD N° 3 MR Tablet TbsPD3MR
Chlorine (HR) 5 – 200 mg/l 1 14 PLPar14 Chlorine HR (Ki) Powder Pillow PPPClHR
Acidifying GP Powder Pillow PPHAFG
Chlorine (HR) 0 – 200 mg/l 1 15 PLPar15 PL Chlorine HR N°1 (541 tests) Liquid PL65ClHR1
PL Chlorine HR N°2 (250/541 tests) Liquid PL30CIHR2/PL65ClHR2
Chlorine Dioxide 0 – 15 mg/l 0.01 64 PLPar64 PL DPD 1 A (250/541 tests) Liquid PL30DPD1A/PL65DPD1A
PL DPD 1 B (250/541 tests) Liquid PL30DPD1B/PL65DPD1B
PL DPD Glycine (250 tests) Liquid PL30DPDGlycine
Chlorine Dioxide 0 – 5 mg/l 0.01 130 PLPar130 DPD N°1 Powder Pillow PPPD1
Glycine Tablet TbsHGC50
Chlorite 0 – 8 mg/l 0.01 106 PLPar106 PL DPD 1 A (250/541 tests) Liquid PL30DPD1A/PL65DPD1A
PL DPD 1 B (250/541 tests) Liquid PL30DPD1B/PL65DPD1B
PL DPD 3 C (250/541 tests) Liquid PL30DPD3C/PL65DPD3C
PL DPD Glycine (250 tests) Liquid PL30DPDGlycine
PL DPD Acidifying (250 tests) Liquid PL30DPDAcidif
PL DPD Neutralising (250 tests) Liquid PL30DPDNeutr
www.primelab.org
58 59
PrimeLab 2.0 – List Of Parameters
Parameter Measurement Range Resolution Parameter ID Item-Code Parameter Reagent(s) (No. Of Tests) Type Of Reagent Item-Code Reagents
Chromium 0 – 1 mg/l 0.01 103 PLPar103 PL Chromate N°1 (142 tests) Powder PLpow10Chromate1
PL Chromate N°2 (50/108 tests) Liquid PL30-/PL65Chromate2
Cyanide 0.01 – 0.50 mg/l 0.01 158 PLPar158 PL Cyanide-11 Powder PL158-kit
PL Cyanide-12 Powder
PL Cyanide-13 Liquid
DEHA 20 – 1000 µg/l 1.0 21 PLPar21 PL Oxyg. Scav. N°1 (270 tests) Liquid PL65OxyScav1
PL Oxyg. Scav. N°2 (65 tests) Liquid PL65OxyScav2
Dissolved Oxygen 0 – 10 mg/l 0.1 163 PLPar163 PL DissOx N°1 Liquid PL30DO1
PL DissOx N°2 Liquid PL30DO2
PL DissOx N°3 Liquid PL30DO3
Erythorbic Acid 0 – 3.5 mg/l 0.01 70 PLPar70 PL Oxyg. Scav. N°1 (270 tests) Liquid PL65OxyScav1
PL Oxyg. Scav. N°2 (65 tests) Liquid PL65OxyScav2
Fluoride (SPADNS) 0 – 2 mg/l 0.01 180 PLPar180 PL SPADNS Fluoride (50 tests) Liquid PL100SPADNSF
www.primelab.org
60 61
PrimeLab 2.0 – List Of Parameters
Parameter Measurement Range Resolution Parameter ID Item-Code Parameter Reagent(s) (No. Of Tests) Type Of Reagent Item-Code Reagents
Hardness–Calcium 0 – 500 mg/l 1 166 PLPar166 PL Calcium Hardness 1 (50 tests) Liquid PL20CH1
PL Calcium Hardness 2(50 tests) Liquid PL20CH2
Hardness–Total (HR) 0 – 500 mg/l 1 148 PLPar148 PL Total Hardness N°1 (50 tests) Liquid PL20TH1
PL Total Hardness N°2 (50 tests) Liquid PL10TH2
Hydrazine 5 – 600 µg/l 1 23 PLPar23 PL Hydrazine N°1 (162 tests) Liquid PL65Hydraz1
Hydrogen Peroxide (LR) 0 – 3.8 mg/l 0.01 66 PLPar66 PL Hyd. Perox. LR N°1 (250 tests) Liquid PL30HydLRP1
PL Hyd. Perox. LR N°2 (250 tests) Liquid PL30HydLRP2
Hydrogen Peroxide (LR) 0 – 3.8 mg/l 0.01 24 PLPar24 Hydr. Peroxide LR Tablet TbsPHP
Hydrogen Peroxide (HR) 0 – 200 mg/l 1 25 PLPar25 PL Hydr. Perox. HR N°1 (541 tests) Liquid PL65HydHRP1
PL Hydr. Perox. HR N°2 (541 tests) Liquid PL65HydHRP2
Hydrogen Peroxide (HR) 0 – 200 mg/l 1 162 PLPar162 Acidifying PT Photometer Tablet TbsHAFPP
Hydr. Peroxide HR Photometer Powder Pillow PPPHPHR
DEWAN–50 0 – 300 mg/l 1 109 PLPar109 Available via DINAX: www.dinax.hu Liquid PL-DX DEWAN-50
Hydroquinone 0 – 2.5 mg/l 0.01 26 PLPar26 PL Oxygen Scavenger N°1 (270 tests) Liquid PL65OxyScav1
PL Oxygen Scavenger N°2 (65 tests) Liquid PL65OxyScav2
Iron (MR) 0 – 10 mg/l 0.01 29 PLPar29 PL Iron MR N°1 (285 tests) Powder PLpow20IronMR1
Iron (MR) Ferrous 0 – 10 mg/l 0.01 127 PLPar127 PL Iron MR N°2 (400 tests) Powder PLpow20IronMR2
Iron (HR) 0 – 30 mg/l 0.01 30 PLPar30 PL Iron HR N°1 (162/108 tests) Liquid PL65IronHR1
PL Iron HR N°2 (375 tests) Liquid PL30IronHR2
www.primelab.org
62 63
PrimeLab 2.0 – List Of Parameters
Parameter Measurement Range Resolution Parameter ID Item-Code Parameter Reagent(s) (No. Of Tests) Type Of Reagent Item-Code Reagents
Iron total 0 – 3 mg/l 0.01 132 PLPar132 FerroVer® Iron PP (Hach) (100 tests) Powder Pillow ppFerVer1
Iron in Oil 20 – 450 mg/l 1 171 PLPar171 Reagents and accessories kit to perform 60 tests Various PLPar171
Isothiazolinone 0.0 – 10.0 mg/l 0.01 88 PLPar88 PL Isothiazolinone N°1 (187 tests) Liquid PL30Isoz1
PL Isothiazolinone N°2 (108 tests) Liquid PL65Isoz2
PL Isothiazolinone N°3 (95 tests) Liquid PL65Isoz3
PL Isothiazolinone N°4 (108 tests) Liquid PL65Isoz4
PL Isothiazolinone N°5 (150 tests) Liquid PL30Isoz5
Legionella 60 – 106 cfu 1 147 PLPar147 1 x bottle (110ml) „L0 Diluent“ Kit to perform max. 9 tests LGP-10
10 x single-doses (each 1ml) „L1 Capture Reagent“ (1 control / batch):
1 x bottle (200ml) „L2 Washing buffer“
10 x single-doses (each 1ml) „L3 Enzyme-labeled
anti-Legionella“
5 x tetra dose (each 5ml) „L4 Enzyme-co-substrates“
1 x bottle (2ml) „L5 Stopping reagent“
5 x disposable pipette
10 x 1ml CB cuvette
10 x 9ml MHCB cuvette
www.primelab.org
64 65
PrimeLab 2.0 – List Of Parameters
Parameter Measurement Range Resolution Parameter ID Item-Code Parameter Reagent(s) (No. Of Tests) Type Of Reagent Item-Code Reagents
Manganese VLR 0 – 0.030 mg/l 0.001 161 PLPar161 Manganese VLR N°1 Tablet TbsHMagVLR1
Manganese VLR N°2 Tablet TbsHMagVLR2
Manganese 0.2 – 5 mg/l 0.1 31 PLPar31 Manganese LR N°1 Powder Pillow PPHMGNSLR1
Manganese LR N°2 Powder Pillow PPPMGNSLR2
Methylethylketoxime 0 – 4.1 mg/l 0.01 69 PLPar69 PL Oxy. Scav. N°1 (270 tests) Liquid PL65OxyScav1
PL Oxy. Scav. N°2 (65 tests) Liquid PL65OxyScav2
Molybdate (HR) 5 – 200 mg/l 0.1 33 PLPar33 PL Molybdate N°1 (162 tests) Liquid PL65Moly1
Molybdate (HR) 0 – 40 mg/l 0.1 134 PLPar134 100 Powder-Pillows MolyVer1 in a PE-bag Powder PPPmolyver1
100 Powder-Pillows MolyVer2 in a PE-bag Powder PPPmolyver2
100 Powder-Pillows MolyVer3 in a PE-bag Powder PPPmolyver3
Nickel (HR) 0 – 10 mg/l 0.1 100 PLPar100 PL Nickel HR N°1 (100 tests) Liquid PL65NickHR1
PL Nickel HR N°2 (150 tests) Liquid PL30NickHR2
PL Nickel HR N°3 (150 tests) Liquid PL60NickHR3
Nitrate 0.00 – 11.00 mg/l 0.1 34 PLPar34 PL Nitrate N°1 (285 tests) Powder PLpow20Nitra1
Nitrate (HR) 1 – 100 mg/l 1 169 PLPar169 Nitrate HR N° 1 Powder Pillow PPHNitra1
Nitrate HR N° 2 Powder Pillow PPPNitra2
Nitrite (LR) 0 – 0.5 mg/l 0.01 35 PLPar35 Nitrite LR Powder Pillow PPPNiLR
Nitrite (HR) 5 – 200 mg/l 0.1 36 PLPar36 PL Nitrite HR N°1 (142/285 tests) Powder PLpow10-/ PLpow20NitriHR1
Nitrite (HR) 0 – 3000 mg/l 1 101 PLPar101 PL Nitrite HR N°2 (108 tests) Liquid PL65NitriteHR2
Nitrogen–Total (LR) 0.5 – 25 mg/l 0.1 151 PLPar151 50 Hydrox. LR vials Kit PL151-kit
50 Persulfate powder packs
50 Reagent A powder packs
50 Reagent B powder packs
50 Acid LR/HR vials
100ml DI-Water
www.primelab.org
66 67
PrimeLab 2.0 – List Of Parameters
Parameter Measurement Range Resolution Parameter ID Item-Code Parameter Reagent(s) (No. Of Tests) Type Of Reagent Item-Code Reagents
Nitrogen–Total (HR) 5 – 150 mg/l 1 152 PLPar152 50 Hydrox. HR vials Kit PL152-kit
50 Persulfate powder packs
50 Reagent A powder packs
50 Reagent B powder packs
50 Acid LR/HR vials
100ml DI-Water
Ozone 0 – 5.4 mg/l 0.1 92 PLPar92 PL DPD 1 A (250/541 tests) Liquid PL30DPD1A/PL65DPD1A
PL DPD 1 B (250/541 tests) Liquid PL30DPD1B/PL65DPD1B
PL DPD 3 C (250/541 tests) Liquid PL30DPD3C/PL65DPD3C
PL DPD Glycine (250 tests) Liquid PL30DPDGlycine
Peracetic Acid (LR) 0.00 – 10.00 mg/l 0.01 164 PLPar164 PD N°4 Tablet TbsPD4
Peracetic Acid (HR) 0 – 300 mg/l 1 165 PLPar165 Chlorine HR (KI) Powder Pillow PPPClHR
Acidifying GP Powder Pillow PPHAFG
Permanganate Time Test 0 – 100 %T 0.1 159 PLPar159 PTT (285 tests) Liquid PL10PTT
in Methanol (tank wash) 10ml Reagent grade Methanol Sealed vial PTT-Metha
pH–value (MR) 6.5 – 8.4 pH 0.01 38 PLPar38 Phenol Red Tablet TbsPpH
pH–value (MR) 6.4 – 8.4 pH 0.01 39 PLPar39 PL pH 6.4-8.4 (270 tests) Liquid PL65PhenRed
Phosphate–ortho (LR) 0 – 4 mg/l 0.01 44 PLPar44 Phosphate (LR) N°1 Powder Pillow PPHPPLR1
Phosphate (LR) N°2 Tablet TbsPPPLR2
www.primelab.org
68 69
PrimeLab 2.0 – List Of Parameters
Parameter Measurement Range Resolution Parameter ID Item-Code Parameter Reagent(s) (No. Of Tests) Type Of Reagent Item-Code Reagents
Phosohate–ortho (LR) 0 – 4 mg/l 0.01 45 PLPar45 PL Phosphate LR N°1 (65 tests) Liquid PL65PPLR1
PL Phosphate LR N°2 (142/285 tests) Powder PLpow10-/ PLpow20PPLR2
Phosphate–ortho (HR) 0 – 80 mg/l 0.1 46 PLPar46 Phosphate (HR) N°1 Powder Pillow PPHPPHR1
Phosphate (HR) N°2 Tablet TbsPPPHR2
Phosphate–ortho (HR) 0 – 100 mg/l 0.1 47 PLPar47 PL Phosphate HR N°1 (65 tests) Liquid PL65PPHR1
PL Phosphate HR N°2 (65 tests) Liquid PL65PPHR2
Phosphonate 0 – 20 mg/l 0.01 87 PLPar87 PL Phosphonate N°1 (285 tests) Powder PLpow20PPHON1
PL Phosphonate N°2 (285 tests) Powder PLpow20PPHON2
PL Phosphonate N°3 (81 tests) Liquid PL65PPHON3
PL Phosphonate N°4 (285 tests) Powder PLpow20PPHON4
Phosphorus–Total (LR) 0 – 2.6 mg/l 0.01 153 PLPar153 50 Phosphorus LR vial Kit PL153-kit
30ml PL Phosphorus LR N°1
10g PL Phosphorus N°2
100 powder p. Phosphate LR N°1
50 tablets Phosphate LR N°2
Phosphorus–Total (HR) 0 – 52 mg/l 0.1 154 PLPar154 50 Phosphorus HR vial Kit PL154-kit
30ml PL Phosphorus HR N°1
10g PL Phosphorus N°2
100 powder p. Phosphate HR N°1
50 tablets Phosphate HR N°2
Polyacrylate 1 – 30 mg/l 0.1 85 PLPar85 PL Polyacrylate N°1 (65 tests) Liquid PL65PLYA1
PL Polyacrylate N°2 (65 tests) Liquid PL65PLYA2
Sanosil 0 – 400 mg/l 0.01 173 PLPar173 PL Hydrogen Peroxide HR N°1 Powder PL65HydHRP1
PL Hydrogen Peroxide HR N°2 Powder PL65HydHRP2
www.primelab.org
70 71
PrimeLab 2.0 – List Of Parameters
Parameter Measurement Range Resolution Parameter ID Item-Code Parameter Reagent(s) (No. Of Tests) Type Of Reagent Item-Code Reagents
Silica (LR) 0 – 5 mg/l 0.01 49 PLPar49 PL Silica LR N°1 (162 tests) Liquid PL65SiLR1
PL Silica LR N°2 (162 tests) Liquid PL65SiLR2
PL Silica LR N°3 (190 tests) Powder PLpow40SiLR3
Silica (HR) 0 – 100 mg/l 1 50 PLPar50 PL Silica HR N°1 (71/142 tests) Powder PLpow10-/ PLpow20SilHR1
PL Silica HR N°2 (241 tests) Powder PLpow60SilHR2
PL Silica HR N°3 (142 tests) Powder PLpow10SilHR3
Sodium Hypochlorite 0.2 – 40 % 0.1 51 PLPar51 Chlorine HR (Ki) Powder Pillow PPPClHR
Acidifying GP Powder Pillow PPHAFG
Sodium Hypochlorite 0.2 – 40 % 0.1 68 PLPar68 PL Chlorine HR N°1 (541 tests) Liquid PL65ClHR1
PL Chlorine HR N°2 (250/541 tests) Liquid PL30CIHR2/ PL65ClHR2
Sulphate 5 – 100 mg/l 1 55 PLPar55 PL Sulphate N°1 (142 tests) Powder PLpow10SULPHA1
Sulphide 0.04 – 0.5 mg/l 0.01 52 PLPar52 Sulphide N°1 Tablet TbsHSULFD1
Sulphide N°2 Tablet TbsPSULFD2
Suphide 0 – 0.7 mg/l 0.01 140 PLPar140 Sulfide 1 (Hach) (1000 tests) Liquid HaSulfide1
Sulfide 2 (Hach) (1000 tests) Liquid HaSulfide2
Sulphite (HR) 0 – 300 mg/l 0.1 105 PLPar105 Sulphite N°1 Tablet TbsHSULFHR1
Sulphite N°2 Tablet TbsPSULFHR2
Sulphite (HR) 0 – 200 mg/l 0.1 174 PLPar 174 PL Oxygen Scavenger 1 Powder PL65OxyScav1
PL Oxygen Scavenger 2 Powder PL65OxyScav2
Tannic acid 0 – 150 mg/l 0.1 91 PLPar91 PL Tannin N°1 (65 tests) Liquid PL65Tannin1
PL Tannin N°2 (125 tests) Liquid PL30Tannin2
Total Oxidant 0 – 8 mg/l 0.01 108 PLPar108 PL DPD 1 A (250/541 tests) Liquid PL30DPD1A/PL65DPD1A
PL DPD 1 B (250/541 tests) Liquid PL30DPD1B/PL65DPD1B
PL DPD 3 C (250/541 tests) Liquid PL30DPD3C/PL65DPD3C
PL DPD Acidifying (250 tests) Liquid PL30DPDAcidif
PL DPD Neutralising (250 tests) Liquid PL30DPDNeutr
www.primelab.org
72 73
PrimeLab 2.0 – List Of Parameters
Parameter Measurement Range Resolution Parameter ID Item-Code Parameter Reagent(s) (No. Of Tests) Type Of Reagent Item-Code Reagents
Urea 0.1 – 2.5 mg/l 0.1 120 PLPar120 Ammonia N°1 Powder Pillow PPHAM1
Ammonia N°2 Powder Pillow PPPAM2
PL Urea N°1 (375 tests) Liquid PL30Urea1
PL Urea N°2 (250 tests) Liquid PL10Urea2
Urea 0.2 – 5.0 mg/l 0.2 150 PLPar150 Ammonia N°1 Powder Pillow PPHAM1
Ammonia N°2 Powder Pillow PPPAM2
PL Urea N°1 (375 tests) Liquid PL30Urea1
PL Urea N°2 (250 tests) Liquid PL10Urea2
www.primelab.org
74 75
PrimeLab 2.0 – accessories
PLSp-Kv2410-10 Set of 10 x 24mm (10ml) round glass vials with lid / light shield PLSp-inj1 Graduated Plastic Syringe (10ml)
integrated in lid
PLSp-inj03 Graduated Plastic Syringe (3ml)
PLSp-Kv1610-10 Set of 10 x 16mm (10ml) round glass vials with lid
PLSp-inj01 Graduated Plastic Syringe (1ml)
PLSp-Kv1-100 Set of 100 x 1ml semi-micro-vials (rectangle)
PLSp-PIP10ml 10 ml pipette (variable volume 1 – 10ml)
PLSp-LG-ELF10 Set of 10 x 60ml measuring cup with red lid
PLSp-PIP10ml-tips10 10 x tips for PLSp-PIP10ml pipette
SVZdev100 100ml plastic measuring cup
PLSp-PIP1ml 1 ml pipette (variable volume 0.1 – 1ml)
PLSp-GlsBot50ml 50ml glass-bottle with stopper
PLSp-PIP1ml-tips10 10 x tips for PLSp-PIP1ml pipette
PLSp-CODheatblock-T Heat block for 12 x 16mm vials. Temp. 70, 100, 120, 148, 150 and 160°C.
Stirring rods / cleaning brushes Heating times: 30 min, 60 min, 90 min, 120 min; 200 – 240 VAC 50Hz;
Maximum 350 W
Item-Code Item Description
PLSp-BltD-1 Bluetooth® USB dongle (to enable Bluetooth® on any Windows–PC)
SPstr10 Set of 10 x 13 cm plastic stirring rods
PLSp2-GSM 4G*–modem (USB–Type–C)
PLSp-str10 Set of 10 x 10.5 cm plastic stirring rods
PLSp2-USBa-c USB–connector (type A to type C)
SPclb10 Set of 10 x 9.5 cm vial-cleaning brushes
PLSp2-USBhuba USB–Hub (Type C and Type A)
www.primelab.org
76 77
PrimeLab 2.0 – accessories Technical Data
PL2Sp-Ref112038-f Reference standard kit for PrimeLab IDs 11 (chlorine by tablet), ID Spectral range: 390nm – 950nm
20 (cyanuric acid) and ID 38 (pH by tablet).2 standards for ID 11 18 wavelength, peaks at 410|435|460|485|510|535|560|585|610|645|680|705|730|760|810|860|900
(~0.5 mg/l and ~2 mg/l), 1 standard for ID 20 (~80 mg/l), 1 standard |940nm, 180° and 90° Setup for direct and indirect measurement
for ID 38 (~7.00 pH) as well as a ZERO vial.
In a box with description. 1 year shelf life. Parameters: More than 140 parameters (flexible setup) – User defined parameter function
PL2Sp-Ref122039-f Reference standard kit for PrimeLab IDs 12 (chlorine by liquid), ID 20 Electrodes: USB–type–C connector for pH|EC|TDS|ORP|Temp-Probes
(cyanuric acid) and ID 39 (pH by liquid).
2 standards for ID 12 (~0.5 mg/l and ~2 mg/l), 1 standard for ID 20 Connectivity: WiFi, USB (type C), 4G* (via USB–modem), Bluetooth® 4.2
(~80 mg/l), 1 standard for ID 39 (~7.00 pH) as well as a ZERO vial. (technical)
In a box with description. 1 year shelf life.
Connectivity: LabCOM® Software (Windows | Mac), LabCOM® App (Android | iOS), LabCOM® Cloud (web-
PL2Sp-RefPTSA 3 x Sealed round (24mm) glass-vial (values: 0 µg/l / 100 µg/l / 400 µg/l) (software) browser)
PL2Sp-RefFLSC 2 x 100ml reference standards 100 µg/l Fluorescein, deionized water Display: 5.5‘‘ Colour–HD touch display
PL2Sp-RefTRB 3 x 10ml reference standards 0.5 NTU, 10 NTU, 1000 Camera: (Available soon) In–built QR–code scanner
Other Accessories
Clock/Date: RTC (Real–Time–Clock) with calendar function
PLSp2-Ad16/Ad1 PrimeLab 2.0 vial adapter for 16mm glass vials / 1ml semi-micro-vials (rectangle)
Menu guidance: Intuitive, display-controlled 4-button menu guidance; test instructions during measurement
process
PLSp-mft-1 Micro fiber cloth 13x13 cm for PrimeLab vials
Languages: >4
PLSp2-Alucase Aluminium trolley with foam inserts for PrimeLab 2.0 plus accessories
Reagents: The calibration curves for the individual parameters|measurement procedures are adjusted to
the reagents offered by Water-i.d.®. Using reagents from other manufacturers may lead to
wrong readings|higher tolerances. PrimeLab reagents are etirely “Made in Germany” or
“Made in UK”!
Ask for our large variety of check-standards (coloured epoxy resin) in sealed 24mm glass vials.
www.primelab.org
78 79
Notes
www.primelab.org
80 81
“When the well‘s dry, we know
the worth of water.“
– Benjamin Franklin
82
Headquarters and Production
Water-i.d.® GmbH
Daimlerstr. 20
76344 Eggenstein
Germany
Tel. +49 (0) 721 - 78 20 29 0
Fax. +49 (0) 721 - 78 20 29 11
www.water-id.com
[email protected]
Water-i.d.® UK
Unit 1, Gilchrist Thomas Industrial Estate
Blaenavon, Pontypool, Torfaen
NP4 9RL
Great Britain / UK
www.water-id.com
[email protected]
Water-i.d.® USA
458 Elizabeth Ave., Suite #5117
Somerset, NJ 08873
USA
Tel. (732) 884-5426
Fax (732) 884-5430
www.water-id.com
[email protected]