Siemens Hipath 4000 Release 1.0 To A Cisco Iad243X Using E1-Isdn Net5 With Sip
Siemens Hipath 4000 Release 1.0 To A Cisco Iad243X Using E1-Isdn Net5 With Sip
Introduction
This is an application note for connectivity to a Siemens HiPath 4000 Release 1.0 with a Cisco IAD243X Gateway via E1 ISDN NET5-
to-SIP communication (10/100baseT).
The network topology diagram (Figure 1) shows the test setup for end-to-end interoperability with the Cisco IAD243X Gateway
connected to the PBX via NET5 (E1 PRI). IP trunk connectivity between the Cisco IAD243X’s is achieved by using SIP protocol.
Limitations
On Call Forward No Answer local (e.g. Phone A calls Phone C CFNA to Phone D); the Cisco IAD243X must be set to Q921/Q931
Network side. If the Cisco IAD 243X is set to Q921/Q931 user side CFNA will not work.
Connected number (COLP) does not interoperate This is an Cisco IAD2432 limitation.
DIU-N2
Software Requirements
Siemens HiPath 4000 Release 1.0
Features
Features Supported
Basic end-to-end calls with CLIP (Calling Number)
Overlap Receiving
Call on-hold
3-way Conference
DTMF end-to-end
Features Not Supported
Calling Name and Connected Name presentation
Configuration
1. Add the new access code to Dialing Plans using WABE + LDPLN.
2. Add the new trunk board using BCSU.
3. Configure Class of Trunk using COT.
4. Configure Class of Parameter for device handler using COP.
5. Configure Class of Service using COSSU.
6. Add the new trunk group access code using BUEND.
7. Configure trunk using TDCSU.
8. Configure Reference Clock using REFTA.
9. Configure trunk Least Cost Routing using LDAT + RICHT.
10. Configure LCR Out-dial Rules using LODR.
11. Enable In-Band DTMF signaling for the Digital Stations using SBCSU.
BCSU
PRI Board
<DISPLAY-BCSU:TYPE=TBL,LTG=1,LTU=2,SLOT=49;
DISPLAY-BCSU:TYPE=TBL,LTG=1,LTU=2,SLOT=49;
H500: AMO BCSU STARTED
<dis-cot:21;
DIS-COT:21;
H500: AMO COT STARTED
COT: 21 INFO:
DEVICE: INDEP SOURCE: DB
PARAMETER:
PRIORITY FOR AC WILL BE DETERMINED FROM MESSAGE PRI
RECALL IF USER HANGS UP IN CONSULTATION CALL RCL
TRUNK CALL TRANSFER XFER
TRUNK SIGNALING ANSWER ANS
CHANGEOVER FROM HOLD TO RING TONE CHRT
KNOCKING OVERRIDE POSSIBLE KNOR
CALL EXTEND FOR BUSY, RING OR CALL STATE CEBC
NETWORKWIDE AUTOMATIC CALLBACK ON BUSY CBBN
NETWORKWIDE AUTOMATIC CALLBACK ON FREE CBFN
DON'T RELEASE CALL TO BUSY HUNT GROUP BSHT
CONNECTION TO ROUTE OPTIMIZATION NODE ROPT
TSC-SIGNALING FOR NETWORKWIDE FEATURES (MANDATORY) TSCS
INCOMING CDR BY ZONE OR FROM LINE ICZL
AOC PER CALL (AUTOMATICAL OR ON REQUEST), MAND. CORNET-NQ AOCC
LINE WITH IMPLICIT NUMBERS LINO
NO TONE NTON
<DISPLAY-COP:COPNO=21;
DISPLAY-COP:COPNO=21;
H500: AMO COP STARTED
COP: 21 INFO:
DEVICE: INDEP SOURCE: DB
PARAMETER:
LINE WITH END-OF-DIAL EOD
SPECIAL MODE SFRM
CODE CALLING RELEASE AFTER EVERY TASK CCR
REGISTRATION OF LAYER 3 ADVISORIES L3AR
MAKE/BREAK RATIO FOR DTMF 1 (PULSE=80MS,PAUSE=80MS) DTM1
CO TRUNK ACCESS:
TRUNK ACCESS TA
TOLL ACCESS:
TRUNK ACCESS TA
<DISPLAY-COSSU:TYPE=COS,COS=10;
DISPLAY-COSSU:TYPE=COS,COS=10;
H500: AMO COSSU STARTED
+------+-----------------+---------------+-----------------+
| COS | VOICE | FAX | DTE |
+------+-----------------+---------------+-----------------+
| 10 |> |
| | TA | NOCO | NOCO |
| | TSUID | NOTIE | NOTIE |
| | TNOTCR | | |
| | RKOABS | | |
| | CDRINT | | |
| | CDRS | | |
| | CDRC | | |
| | COSXCD | | |
| | VCE | | |
| | FWDNWK | | |
| | MSN | | |
| | FWDECA | | |
| | CFB | | |
| | CFNR | | |
| | FWDEXT | | |
| | | | |
+------+-----------------+---------------+-----------------+
AMO-COSSU-111 CLASSES OF SERVICE
DISPLAY COMPLETED;
<DISPLAY-BUEND:TGRP=20,FORMAT=L;
DISPLAY-BUEND:TGRP=20,FORMAT=L;
H500: AMO BUEND STARTED
<DISPLAY-TDCSU:PEN1=1-2-49-0;
DISPLAY-TDCSU:PEN1=1-2-49-0;
H500: AMO TDCSU STARTED
+------------------------ DIGITAL TRUNK (FORMAT=L) -------------------------+
| DEV = S2CONN PEN = 1-02-049-0 TGRP = 20 |
|---------------------------------------------------------------------------|
| PROTVAR = ETSI INS = Y SRCHMODE = ASC |
| COTNO = 21 COPNO = 21 DPLN = 0 |
| ITR = 1 COS = 10 LCOSV = 1 |
| LCOSD = 1 CCT = HICOM S2 DESTNO = 1 |
| SEGMENT = 1 DEDSCC = DEDSVC = NONE |
| FACILITY = DITIDX = SRTIDX = |
| TRTBL = GDTR SIDANI = N ATNTYP = TIE |
| CBMATTR = NONE NWMUXTIM = 10 TCHARG = N |
| SUPPRESS = 0 DGTPR = CHIMAP = N |
| ISDNIP = ISDNNP = |
| PNPL2P = PNPL1P = PNPAC = |
| TRACOUNT = 31 SATCOUNT = MANY NNO = 1 -1 -300 |
| ALARMNO = 0 FIDX = 1 CARRIER = 1 |
| ZONE = EMPTY COTX = 21 FWDX = 5 |
| DOMTYPE = DOMAINNO = TPROFNO = |
| INIGHT = CCHDL = |
| UUSCCX = 16 UUSCCY = 8 FNIDX = 1 |
| CLASSMRK = EC & G711 & G729OPT SRCGRP = |
| TCCID = |
|---------------------------------------------------------------------------|
| BCNEG = N BCGR = 1 LWPAR = 1 |
| LWPP = 0 LWLT = 0 LWPS = 0 |
| LWR1 = 0 LWR2 = 0 |
| SVCDOM = |
| BCHAN = 1 && 30 |
| |
+---------------------------------------------------------------------------+
AMOUNT OF B-CHANNELS IN THIS DISPLAY-OUTPUT: 30
<DISPLAY-LWPAR:FORMAT=L,TYPE=DIUS2,BLNO=1;
DISPLAY-LWPAR:FORMAT=L,TYPE=DIUS2,BLNO=1;
H500: AMO LWPAR STARTED
+-----------------------------------------------------------------------+
| LOADWARE PARAMETERS CIRCUIT TYPE: DIUS2 SOURCE:DB BLOCK: 1 |
+-----------------------------------------------------------------------+
| LNTYPE = COPPER VERSION = S2 QUAL = ON |
| MASTER = Y DCHAN1 = 16 DCHAN2 = 0 |
| PATTERN = D5H QUAL1 = 10 SEC. QUAL2 = 10 MIN. |
| SMD = Y PERMACT = Y FCBAB = DFH |
| CDG = N FIXEDTEI = 0 CNTRNR = 255 |
| TEIVERIF = N CRC4REP = N |
| DEV = INDEP |
| INFO = |
+-----------------------------------------------------------------------+
<DISPLAY-TDCSU:PEN1=1-2-49-0;
DISPLAY-TDCSU:PEN1=1-2-49-0;
H500: AMO TDCSU STARTED
+------------------------ DIGITAL TRUNK (FORMAT=L) -------------------------+
| DEV = S2CONN PEN = 1-02-049-0 TGRP = 20 |
|---------------------------------------------------------------------------|
| PROTVAR = ETSI INS = Y SRCHMODE = ASC |
| COTNO = 21 COPNO = 21 DPLN = 0 |
| ITR = 1 COS = 10 LCOSV = 1 |
| LCOSD = 1 CCT = HICOM S2 DESTNO = 1 |
| SEGMENT = 1 DEDSCC = DEDSVC = NONE |
| FACILITY = DITIDX = SRTIDX = |
| TRTBL = GDTR SIDANI = N ATNTYP = TIE |
| CBMATTR = NONE NWMUXTIM = 10 TCHARG = N |
| SUPPRESS = 0 DGTPR = CHIMAP = N |
| ISDNIP = ISDNNP = |
| PNPL2P = PNPL1P = PNPAC = |
| TRACOUNT = 31 SATCOUNT = MANY NNO = 1 -1 -300 |
| ALARMNO = 0 FIDX = 1 CARRIER = 1 |
| ZONE = EMPTY COTX = 21 FWDX = 5 |
| DOMTYPE = DOMAINNO = TPROFNO = |
| INIGHT = CCHDL = |
| UUSCCX = 16 UUSCCY = 8 FNIDX = 1 |
| CLASSMRK = EC & G711 & G729OPT SRCGRP = |
| TCCID = |
|---------------------------------------------------------------------------|
| BCNEG = N BCGR = 1 LWPAR = 0 |
| LWPP = 0 LWLT = 0 LWPS = 0 |
| LWR1 = 0 LWR2 = 0 |
| SVCDOM = |
| BCHAN = 1 && 30 |
| |
+---------------------------------------------------------------------------+
AMOUNT OF B-CHANNELS IN THIS DISPLAY-OUTPUT: 30
<DISPLAY-LWPAR:FORMAT=L,TYPE=DIUS2,BLNO=0;
DISPLAY-LWPAR:FORMAT=L,TYPE=DIUS2,BLNO=0;
H500: AMO LWPAR STARTED
+-----------------------------------------------------------------------+
| LOADWARE PARAMETERS CIRCUIT TYPE: DIUS2 SOURCE:DB BLOCK: 0 |
+-----------------------------------------------------------------------+
| LNTYPE = COPPER VERSION = S2 QUAL = ON |
| MASTER = N DCHAN1 = 16 DCHAN2 = 0 |
| PATTERN = D5H QUAL1 = 10 SEC. QUAL2 = 10 MIN. |
| SMD = N PERMACT = Y FCBAB = DFH |
| CDG = N FIXEDTEI = 0 CNTRNR = 255 |
| TEIVERIF = N CRC4REP = N |
| DEV = INDEP |
| INFO = |
+-----------------------------------------------------------------------+
Ericsson-1#sh run
Building configuration...
Ericsson-1#
WITHOUT NOTICE. ALL STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO
BE ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE
IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR
INCIDENTAL DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA
ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF CISCO OR ITS SUPPLIERS HAVE BEEN
Argentina • Australia • Austria • Belgium • Brazil • Bulgaria • Canada • Chile • China PRC • Colombia • Costa Rica • Croatia • Czech
Republic • Denmark • Dubai, UAE • Finland • France • Germany • Greece • Hong Kong SAR • Hungary • India • Indonesia • Ireland •
Israel • Italy • Japan • Korea • Luxembourg • Malaysia • Mexico • The Netherlands • New Zealand • Norway • Peru • Philippines •
Poland • Portugal • Puerto Rico • Romania • Russia • Saudi Arabia • Scotland • Singapore • Slovakia • Slovenia • South Africa • Spain •
Sweden • Switzerland • Taiwan • Thailand • Turkey Ukraine • United Kingdom • United States • Venezuela • Vietnam • Zimbabwe
© 2007 Cisco Systems, Inc. All rights reserved.
CCVP, the Cisco Logo, and the Cisco Square Bridge logo are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn is a service mark of
Cisco Systems, Inc.; and Access Registrar, Aironet, BPX, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, CCSP, Cisco, the Cisco Certified Internetwork Expert logo,
Cisco IOS, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Cisco Unity, Enterprise/Solver, EtherChannel, EtherFast, EtherSwitch, Fast Step,
Follow Me Browsing, FormShare, GigaDrive, GigaStack, HomeLink, Internet Quotient, IOS, iPhone, IP/TV, iQ Expertise, the iQ logo, iQ Net Readiness Scorecard, iQuick
Study, LightStream, Linksys, MeetingPlace, MGX, Networking Academy, Network Registrar, Packet, PIX, ProConnect, RateMUX, ScriptShare, SlideCast, SMARTnet,
StackWise, The Fastest Way to Increase Your Internet Quotient, and TransPath are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the United States and
certain other countries.
All other trademarks mentioned in this document or Website are the property of their respective owners. The use of the word partner does not imply a partnership relationship
between Cisco and any other company. (0612R)
Printed in the USA