DASS 3phase - MANUAL V0.9 - ENG
DASS 3phase - MANUAL V0.9 - ENG
DASS Grid-connected
Photovoltaic Inverter
(3-Phase Power Conditioning System)
0
Contents
3. Installation......................................................................11
4. Operations.........................................................................22
6. Specification of Products..........................................................31
7. Quality Guaranteed.................................................................33
7.1 Quality Liaison..............................................................33
0
1. Caution for Safety
Cautions for safety must be kept under any circumstances in order to prevent accident or
dangers for safe and right use
Read the installation manual very carefully before you install, operate or maintain the
products.
There are two types of caution in the manual- warning and attention as below.
Indicates that you must be careful for possible danger under certain conditions
Indicates that you must be careful for electric shock under certain conditions.
The repair, check-up, part-changes for inverters must be performed by only certified
engineer. The engineers must have the following qualifications.
W Warning
Do not touch outside terminal any time when you install or operate product.
Main terminal with electric power on makes inner parts and inner circuits flow electric
current. This current is very dangerous and it could cause severe injury or death when you
touch the currents.
1
Do not operate switch when your hands are wet.
It could cause electric shock.
Do not open cover even when power is off except for regular check-up.
Inverter is still charged even if power is off due to the long-time charging, which could
cause electric shock.
Shut off the power and wait more than 10 minutes to confirm complete discharging to
VOM from inverter when doing wiring work or regular check-up.
Inverter is still charged even if power is off, which could cause electric shock.
Attention
Keep away from inflammables.
Shut off output power (solar cell) and input power (AC power) immediately when
inverter malfunctions.
Otherwise, it could lead to fire by subsequent accidents.
Do not input power even if you finish installation when inverter or parts are
damaged.
It could cause electric shock.
Be careful not to get any screw, metals, water, oil, etc. inside inverter.
It could cause fire.
2
Directions
(1) transportation
(2) applications
(3) Trouble-shooting
Install additional safety device such as emergency brake just in case that inverter is
damaged and out of control.
(4) Maintenance and Repair
Don’t perform mega-test (for electric insulation and resistance) for inverter control
circuit. It could cause malfunctions or damages.
Refer chapter 6 for detailed explanations.
(5) Disposal
(6) Others
The pictures occasionally drop the explanations for cover or breaker. However, you must
strictly follow the guidelines in the manual for cover and breaker installation.
3
Directions for Installation
Installation
Wiring
As this equipment is expensive, the expert should perform wiring work or inspection in
person.
Wire with the wire more than allowable current applied by capacity.
After install the inverter body, perform wiring work.
If you connect wrong contacts, damage may happen on the inverter.
Especially, in case the polarities (+/-) of DC power, damage may happen on the inverter
or any accident may occur.
4
Make sure of the present condition of displayed screen.
2. Outline of Products
2.1 Basic data
2.1.1 Contents you should know before using the appliance
Thank you for purchasing our products. To use the appliance right, it’s important for you
to understand the function of the inverter and how to use it through the manual. If you
misuse the inverter, it is operated abnormally or its performance may be depreciated.
Especially, as the inverter might be broken or damage might impair the body seriously, use
the inverter after understanding the application or installation manual enough in using
the inverter.
DSP - 3 3 XXX K
Mark Name Mark Capacity
DSP Das PCS 10K 10 kW
20K 20 kW
Name of
Mark 30K 30 kW
Series
Single
1 50K 50 kW
Phase
3 3 Phase 100K 100 kW
200k 200 kW
Output
Mark 250K 250 kW
Power
2 220 V
3 380 V
5
2.1.5 Wiring
Connect power and running signal (signal for control) to the block of terminal. If you
don’t connect them, the inverter or peripheral add-ons may be damaged, so be careful of
wiring. Especially, watch out the polarity of input power (DC)
6
(7) Easy Parallel Operation
If the capacity of solar cells increases, you can add an inverter without any exclusive
equipment and increase its capacity for bulky power generation.
7
2.2 External Dimensions
2.2.1 DSP-3310K
8
2.2.2 DSP-3320K~3330K
2.2.3 DSP-3350K
9
2.2.4 DSP-33100K
10
2.3 Names and Functions of Each Part
2.3.1 DSP-3310K ~ 3350K
External Internal
① Key pad
-Key pad presents the operating condition of the inverter on the LDC screen.
② DC INPUT MCCB
-This part prevents DC of input part of a converter from photovoltaic module
contacting panel.
③ AC OUTPUT MCCB
-This device disconnects AC output part from grid system.
11
-This contact is connected to the earth wire.
2.3.2 DSP-33100K
External Internal
① Keypad
-Keypad displays synthetically running condition of the inverter on LCD screen.
② Emergency Switch
-Emergency Switch stops the inverter by compulsion in case of emergency
situation. The inverter doesn’t re-run if the switch is turned on.
12
properly. Check the emergency switch.
③ DC Input MCCB 1
-DC Input MCCB 1 disconnects DC input into Booster 1 of the inverter from solar
light module contacting panel.
④ DC Input MCCB 2
-DC Input MCCB 1 disconnects DC input into Booster 2 of the inverter from
solar light module contacting panel.
⑤ AC Output MCCB
-AC Output MCCB disconnects the inverter from grid line.
13
2.3.3 DSP-33200K, DSP-33250K
External Internal
① Integral Keypad
-Integral Keypad indicates synthetically running condition of Master and Slave
Inverter on LCD screen.
② Emergency Switch
-In case emergency situation occurs, Emergency Switch stops the inverter by
compulsion. The inverter doesn’t re-run if the switch is turned on.
③ Master Keypad
-Master Keypad displays running condition of Master Inverter on LCD screen.
④ Slave Keypad
-Slave Keypad displays running condition of Slave Inverter on LCD screen
14
⑤ DC Input MCCB 1
-DC Input MCCB 1 disconnects DC input into Master Inverter from solar light
module contacting panel.
⑥ DC Input MCCB 2
-DC Input MCCB 1 disconnects DC input into Slave Inverter from solar light
module contacting panel.
⑦ AC Output MCCB
-AC Output MCCB disconnects the inverter from grid series line.
⑩ Ground Busbar
-Ground Busbar is connected to the earth wire.
15
3. Installation of Products
around the place where the converter is installed less than allowable temperature(-10 ~
40℃).
3) Avoid hot and humid place (Relative humidity should be less than 90%. No dewfall).
6) Install the converter to let its heat emitted without a hitch, securing peripheral space.
7) Avoid the places where oil mist, flammable gas, fabric mote, dust and moisture exist.
8) Install the bolts of specified size, fixing them with a determined torque.
If you uncover the cover in front on the lower part of inverter, terminal blocks exist
as below. As their composition is different from each other by their capacity, connect
them exactly according to the manual.
In case of input power, connect positive (+) power source to the input contact (PV [+])
of the inverter, negative (-) power source to the input contact (PV [-]) and then
supply power. The inverter might be damaged by false connection.
For power input contacts and output contacts, use pressing contacts that insulating caps
are attached. Chips of wire might result in default, failure or false operation.
In case you change any wire due to improper matter, make sure if the power for the
LC(Liquid Crystal) of the keypad on the main body is turned off or not, perform wiring
16
work, please. As the internal capacity of an inverter is charged with high voltage, it is
dangerous.
To prevent electric shock, perform No.3 earth work and special No.4 earth work with the
inverter. Make sure that the resistance of earth should be less than 100 Ω.
Connect the contacts of the inverter to the exclusive terminal blocks. Don’t use a case
or sash as earth terminal.
For the earth wire, use exclusive earth wire complying with the standard. Connect the
earth contacts to the spot adjacent to the inverter.
Apply determined torque to the bolts. If they are fastened loose, it causes short or false
operation.
For the electric wires, use copper wire more than 600V, 75℃.
17
3.2.1 Wiring Diagram of DSP-3310K~3350K
Inlet
Inlet
Inlet
Inlet
④ Terminal Block of Output of the inverter is connected to R phase of GRID series line.
Output Power
⑤ Output of the inverter is connected to S phase of GRID series line.
(3Φ3W 380V)
⑧ Output of the inverter is connected to T phase of GRID series line.
⑨ Neutral Terminal Block Output of the inverter isn’t connected to GRID series line.
18
3.2.3 DSP-33200K~33250K
3.2.3 DSP-M33200K~M33250K
If the ambient temperature of installing site could be over 40°C, please install
duct for ventilation to prevent ambient temperature from rising. There is an example
picture below.
19
Inlet
Positive(+)
Connect positive (PV [+]) of DC line inlet from the
① Terminal Block of
contacting panel.
Input Power
Positive(-)
Connect negative (PV [-]) of DC line inlet from the
② Terminal Block of
contacting panel.
Input Power
Earth Terminal
③ Connect the earth wire.
Block
Integrated Keypad
④ Connect the power of integrated keypad(1Φ 220Vac).
Terminal Block
Output of the inverter is connected to R phase of GRID series
⑤
line.
Terminal Block
Output of the inverter is connected to S phase of GRID series
⑥ of Output Power
line.
(3Φ3W 380Vac)
Output of the inverter is connected to T phase of GRID series
⑦
line.
Neutral Terminal
⑧ Output of the inverter isn’t connected to GRID series line.
Block
20
3.3 Wiring of Web Communications Module (Monitoring)
3.3.1 Web Communications module of DSP-3310 ~ 100K
The keypad is mounted on the internal part of frontal cover. Open the frontal door and
connect RS232C/485 communications contacts to web communications module. In wiring
communications cable, be careful of not to pass the cable near the power wire, or any
error might happen for web monitoring system.
DSP-3310 ~ 100K series products support 2 communications methods such as RS232C and RS485.
Each communications methods can be converted through operating the switch. In installing
communications line, be careful of not to cut the cables of keypad.
RS485 Communications
Contacts
For Monitoring
RS485 Communications
Contacts
For Module
21
4. The Condition of Run and Operation
Photovoltaic inverter of DSP-33 series is the system connected to fully automate digital
control. For DSP-33 series, the power of inverter (keypad) is turned on automatically and
begins to generate its power if PV voltage becomes more 400V.)
If PV voltage becomes under 200V at set of sun, the inverter stops automatically. Also, if the
voltage charged into the equipment is discharged, the power (keypad) is turned off.
※ Please, perform run/rest procedures, referring the name and function of each component on
Item 2.3.
4.1.1 Run
Confirming MCCB
The Condition for Control(ON)
of Wires
22
(5) Turn on AC MCCB (Output Breaker).
If AC MCCB is turned on, grid LED on the keypad is out of lit and operation standby
count starts (300 secs, 5 mins). At this time, if you want to run it without rest, press
[RUN] button on the keypad to run it.
4.1.2 Stop
(3) Turn off MCCB for control [For only 200 ~ 250k series]
This function is used when you operate the inverter for a long time. You don’t need to
turn off when you leave the inverter for a while.
23
4.2 Explanation of the Functions on the Keypad
4.2.1 Outlook of Keypad
Key Explanation
You can get into or out from the set menu in the mode of indicating condition.
Menu You can move to the upper set mode from the lower set mode.
In setting parameters, you can move the position of cursor“_”.
You can set a menu in the set menu.
Enter You can select lower set menu.
You can save the set value of parameters in set parameters.
Direction Key
You can change the kind of set menu and condition indicated contents.
∧∨< > In setting parameters, the position of “_” cursor is changed and the values of
parameters on the position where the cursor exist increases/decreases.
If any error occurs, this function turns off alarm and“Fault”is on the screen
BZ-off
continuously.
If you put this key when any error happens, the inverter’s functions are
F-RESET
initialized.
You can re-operate the stopped inverter.
RUN If you press this button, waiting period of 300 seconds is omitted and the
inverter begins to be operated in no time.
24
(2) Explanation of Indicating the condition of LED
Condition
Explanation
of LED
Input condition from the module of solar cells is indicated
Solar PV
(Red LED is lit: More than 400V of PV voltage)
Operated condition of the inverter is indicated
Operation
(Green LED is lit: The inverter runs in sound).
The condition of system is indicated (Yellow LED is lit: The system is
Grid
normal).
FAULT occurs for the operation of the inverter (Red LED is lit: Error occurs).
25
4.4 Displayed Screen of 200 ~ 250k Series
200~250K applies active parallel running algorithm and only Master (low load) Inverter
is operated when the sun rises. If the rate of power generation in Master (Module 1)
Inverter is up to 70% of the rated capacity for the increased radiation, Slave Inverter
(Module 2) begins to run in parallel mode.
If the rate of power generation decreases below 30% of the rated capacity for the
decreased radiation, Slave Inverter is stopped to be standby mode.
2 keypads are mounted in the keypad responding to each module (Master, Slave) of
200~250K series.
26
4.4.3 Screen of Integrated Keypad
Line1. Total Sum of Capacity of Master/Slave’s Present Power
Generation
Line2. Rated Capacity of Inverter
Line3. Input Condition of Solar Cells (DC Voltage / Current)
Line4. Capacity of Power Generation Accumulated Until Now
27
5. Maintenance & Repair
5.2.1 Buzzer
If any abnormal cause such as moment overload which may be the cause of failure happens, the
buzzer rings consecutively. If the moment overload is cancelled, buzzer doesn’t ring any
more.
If you press [BZ-off] button on the keypad when the buzzer rings, the buzzer doesn’t ring
any more. If you press this button again, the buzzer rings. In case any error occurs for the
condition that alarm doesn’t ring any more, the buzzer rings normally.
5.2.2 Failure
Over voltage
In case the voltage of solar cells is more than the determined voltage, stop the system of
inverter to protect the system.
※In case of DSP-33200K ~ 250K series, if you want to cancel the alarm, you should reset the
entire integrated keypad and internal Master/Slave keypad.
If serious damage occurs for the inverter, the inverter indicates that any error happens on
the LCD screen and buzzer rings at this time. If you press [F-RESET] and then [BZ-off] on
the keypad to cancel the alarm and error, the alarm or error is cancelled. After the alarm
is cancelled, the converter begins run standby counts(300 secs, 5 mins). In case the alarm
is continued to ring, stop the inverter completely and then contact to the headquarters to
fix the converter.
28
5.3 Symptoms of Failure
If any error happens, indicate this error and stop running.
If any error happens, the result is indicated on the window of the keypad.
Cause
Order Indication Occurred Cause Measures
of Error
After inspecting the module of solar
If the voltage of solar
Input DC Over cells, run the inverter.
1 cells is higher than
Overvoltage voltage If re-run is impossible, ask for
the determined voltage.
service center.
After inspecting system voltage, re-
If the system voltage
Output Over run the inverter.
2 is higher than the
Overvoltage voltage If re-run is impossible, ask for
determined voltage.
service center.
Remove the cause of over-current such
Output In case the output of
Over as short, run the inverter.
3 Over- inverter is of over-
current If re-run is impossible, ask for
current current
service center.
Check the temperature sensor and
Overheating In case the temperature cable. And remove the cause of over
Over
4 of inside the inverter is heat.
heat
Converter higher than 85℃ If re-run is impossible, ask for
service center.
Confirm the condition of earth and
Error of Earth In case leaked current insulation.
5
Earth fault occurs If re-run is impossible, ask for
service center.
Check the IGBT and Control board. If
In case inverter
there is no reason, re-run the
Error of IGBT switching
6 inverter.
Element Error element and controlling
If re-run is impossible, ask for
board is out of order
service center.
Check the phase sequence. And Change
RST phase
Reverse RST phase sequence is the R to S cable.
7 sequence
Phase mismatch If re-run is impossible, ask for
mismatch
service center.
Check the ACB or signal cable to
Malfunction operate ACB.
8 MC Error Malfunction of ACB
of ACB If re-run is impossible, ask for
service center.
29
5.4 Asking for A/S
30
6. Specification of Products
31
Name of Type: D S P-▨ ▨ ▨ ▨ K 3350 33100
32
Name of Type: D S P-▨ ▨ ▨ ▨ K 33200 33250
Max. Open Circuit Voltage 820 Vdc
Protective Structure IP 20
33
※ The scale of this product might be changed without any notice. Please, ask for the matter in purchasing our
products.
7. Quality Guaranteed
7.1 Quality Liaison
Quality Liaison
If failure occurred under normally using condition within the period of quality guaranteed, your
product can be tested and fixed for free.
If the failure of our products that you have is related to the below contents,
we will repair the product through payment charged A/S
• The product was out of order due to the customer’s intention or carelessness
• The product was out of order due to error of applied current or inferiority of
the connected product.
• Any failure occurred by natural calamity.
• In case the product was repaired or revised at the other shop, not at the designated
service center
• In case of the nameplate of Dass Tech
• In case any failure occurs after the user dismantled, repaired or replaced our products
34
• In case you replaced the component of our product because the lifetime of our product was over
• In case other person, not our designated service staff, revised or fix our products.
• In case the period of compensatory A/S is over
35
The scale of this product might be changed without any notice. Please, ask for the matter in
purchasing our products.
36