0% found this document useful (0 votes)
26 views6 pages

Datasheet Demasias Cárcamo

The document provides technical specifications and performance data for the HPGH(X)/HPGHH(X) grinder pumps, including power ratings, dimensions, and electrical data. It also details the SJE PumpMaster® pump switch, designed for controlling pumps in various applications, with specifications on cable type, float dimensions, and electrical ratings. Additional ordering information and options for the pump switch are included.

Uploaded by

EMILIO
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
26 views6 pages

Datasheet Demasias Cárcamo

The document provides technical specifications and performance data for the HPGH(X)/HPGHH(X) grinder pumps, including power ratings, dimensions, and electrical data. It also details the SJE PumpMaster® pump switch, designed for controlling pumps in various applications, with specifications on cable type, float dimensions, and electrical ratings. Additional ordering information and options for the pump switch are included.

Uploaded by

EMILIO
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Customer : Pump Performance Curve

Project name : Default Encompass 2.0 - 17.5.2.0

6.0

4.5
Power - kW

Power
3.0

1.5

0.0

60
Minimum Continuous Stable Flow

54

48
159 mm

42

36
Head - m

30

24

18

108 mm
12

0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0
Flow - l/s

Item number : 065 Size : Hydromatic - HPGHH/ Flow, rated : 5.00 l/s
Service : HPGHHX-500 Differential head / pressure, rated : 28.50 m
Quantity :1 Stages :1 NPSH required :-
Quote number : 691258 Speed, rated : 3500 rpm Fluid density, rated / max : 0.998 / 0.998 kg/dm3
Date last saved : 25 Jan 2018 12:42 PM Based on curve number : SUB_G_O_AH_00005_B_2 Viscosity : 1.00 cSt
Rev 2012-03-23 Cq/Ch/Ce/Cn [ANSI/HI 9.6.7-2010] : 1.00 / 1.00 / 1.00 / 1.00
Efficiency :-
Power, rated : 3.42 kW

PICSA, SA DE CV PHONE: · FAX:


AMACUZAC NO 176 · COL SAN PEDRO IZTACALCO, CP 08220
Dimensional Data – HPGHH
Section GRINDER Page 208

Horizontal Discharge

E
3/4"

G 3/4" Dia. holes 4 places


equally spaced on a 6" Dia.
D B.C. straddle centerline

C
F

3"-125#
DISCHARGE FLANGE

H
I SUCTION

A B C D E F G H I
HPGHH 22-7/8 13-3/4 17-7/8 9-11/16 8-1/4 18-1/8 4-27/32 4 2
Horizontal Discharge ALL DIMENSIONS IN INCHES
NOTE: CASTING DIMENSIONS MAY VARY ± 1/8”

© 2014 Pentair Ltd.


Electrical Data – HPGH(X)/HPGHH(X)
Section GRINDER Page 306

MODEL: HPGH(X)/HPGHH(X) — Grinder Pumps

R.P.M. 3450
MOTOR TYPE ENCLOSED, OIL COOLED INDUCTION
MOTOR DESIGN NEMA TYPE B (3ø) L (1ø)
GENERAL INSULATION CLASS F
STATOR WINDING CLASS F
MAXIMUM STATOR TEMPERATURE 155°C – 311°F
MOTOR PROTECTION BI-METALLIC, TEMPERATURE SENSITIVE DISC,
SIZED TO OPEN AT 120°C AND AUTOMATICALLY
RESET @ 30–35°C DIFFERENTIAL, ONE IN
SINGLE PHASE, TWO IN THREE PHASE
ELECTRICAL RATINGS HEAT 24VDC 115VAC 230VAC
SENSOR 5AMPS 5AMPS 5AMPS
SEAL FAIL 300VAC 5mA
VOLTAGE TOLERANCE ±10%
AM LOAD

PS .
E

AM . RTR
GE

OD
ASE

KVA RT
N

KVA N
LTA

PS
HP

PS
SF

AM F
CC

RU

STA

RU
S

kW
D
L
PH

FUL

LCK
VO

NE

200 20.6 24.7 81


3.0 1 F 1.2 3.8 16.2 4.1
230 17.9 21.5 70.5
5.0 200 1 F 1.2 33.9 40.6 125 6.6 28.8 6.8
5.0 230 1 F 1.2 29.5 35.4 125 6.6 28.8 6.8
200 10.9 13.0 53
230 9.4 11.2 46.2
3.0 3 G 1.2 3.2 14.4 3.8
460 4.7 5.6 23
575 3.8 4.5 18.5
200 17.9 21.5 83
230 15.6 18.7 72
5.0 3 G 1.2 5.4 28.7 6.2
460 7.8 9.4 36
575 6.2 7.4 28.8
200 24.8 29.7 149.5
230 21.5 25.8 130
7.5 3 H 1.2 7.4 51.8 8.6
460 10.8 12.9 65
575 8.6 10.3 52

© 2014 Pentair Ltd.


Technical Data – HPGH(X)/HPGHH(X)
Section GRINDER Page 405

MODEL: HPGH(X)/HPGHH(X) — Grinder Pumps


Physical Data:
DISCHARGE SIZE 2” NPT ON HPGH(X), 3” 125 LB. FLANGE ON HPGHH(X)
IMPELLER TYPE SEMI-OPEN 5 VANE
 &$%/(/(1*7+ ·67$1'$5'

Liquid Handling:
MAXIMUM LIQUID TEMP. 140ºF
ACCEPTABLE pH RANGE 6–9
SPECIFIC GRAVITY 0.9 – 1.1
VISCOSITY 28 – 35 SSU

Temperature:
MAXIMUM STATOR 311°F
OIL FLASH POINT 390°F
HEAT SENSOR Open: 257°F MAX./ 239°F MIN.
Closed: 194°F MAX./ 149°F MIN.

Technical Data:
POWER CORD TYPE SOOW, W
SENSOR CORD TYPE SOOW
MOTOR HOUSING CAST IRON ASTM A-48 CLASS 30
CASING CAST IRON ASTM A-48 CLASS 30
CONSTRUCTION

IMPELLER RED BRASS #85-5-5-5 ASTM B584-836


MATERIALS OF

CUTTERS
Stationary: 440C STAINLESS STEEL HARDENED TO 55-60 ROCKWELL C
Upper (Axial): 440C STAINLESS STEEL HARDENED TO 55-60 ROCKWELL C
Lower (Radial): 440C STAINLESS STEEL HARDENED TO 55-60 ROCKWELL C
MOTOR SHAFT 416 STAINLESS STEEL
HARDWARE 300 SERIES STAINLESS STEEL
O-RINGS NITRILE
MECHANICAL SEALS
Standard: UPPER AND LOWER CARBON/CERAMIC/NITRILE, TYPE 21
Optional: LOWER TUNGSTEN CARBIDE/TUNGSTEN CARBIDE/NITRILE, TYPE 21
UPPER BEARING (RADIAL) SINGLE ROW BALL (6303)
LOWER BEARING (THRUST) SINGLE ROW BALL
MIN. B-10 BEARING LIFE 50,000 Hrs

© 2014 Pentair Ltd.


SJE PUMPMASTER® Pump Switch
Mechanically-activated, wide-angle switch designed to control pumps up to 1/2 HP at 120
VAC and 1 HP at 230 VAC.

This mechanically-activated, wide-angle pump switch provides automatic control of pumps in:
 Q Potable Water
Q Water
 Q Sewage applications

The SJE PumpMaster® pump switch is not sensitive to rotation or turbulence allowing it to be
used in both calm and turbulent applications.

U.S. Patent Nos. 5,087,801 & 5,142,108

FEATURES SPECIFICATIONS
 Q Passed NSF Standard 61 protocol by an approved Water Quality CABLE: flexible 16 gauge, 2 conductor (UL,
Association laboratory. CSA) SJOW, water-resistant, (CPE)

 Q Heavy-duty contacts. FLOAT: 7.75 cm diameter x 9.04 cm long (3.05


inch x 3.56 inch), high impact, corrosion
 Q Controls pumps up to 1/2 HP at 120 VAC and 1 HP at 230 VAC. resistant, PVC housing for use in
sewage and water up to 60oC (140oF)
 Q Adjustable pumping range of 18 to 91 cm (7 to 36 inches).
ELECTRICAL:
 Q Includes standard mounting clamp and boxed packaging. 120 VAC 50/60 Hz Single Phase:
Maximum Pump Running Current:
 Q UL Recognized for use in water and sewage. 13 amps
Maximum Pump Starting Current:
 Q CSA Certified. 85 amps
Recommended Pump HP:
 Q Three-year limited warranty. 373 W (1/2 HP) or less

230 VAC 50/60 Hz Single Phase:


Maximum Pump Running Current:
13 amps
Maximum Pump Starting Current:
85 amps
Pump Down / ON position Pump Down / OFF position Recommended Pump HP:
contacts
CLOSED
contacts
746 W (1 HP) or less
OPEN

NOTE: This switch must be used with pumps


that provide integral thermal overload
protection.

on/off ramp
on/off ramp
steel ball steel ball

OPTIONS
This switch is available:

 Q for pump down or pump up applications as specified by part number.

 Q with a 120 VAC or 230 VAC piggy-back plug.

 Q without a plug for direct wiring in 120 VAC or 230 VAC applications.

 Q in standard cable lengths of 3, 5, 6, or 10 meters and 10, 15, 20, or


30 feet (longer lengths available).
PO Box 1708, Detroit Lakes, MN 56502
Phone: (01) 218 847 1317
email: [email protected]
SEE BACKSIDE FOR ORDERING INFORMATION. www.sjerhombus.com 51
SJE PUMPMASTER® Pump Switch
Mechanically-activated, wide-angle switch designed to control pumps up to 1/2 HP at 120 VAC and 1 HP at 230 VAC.

ORDERING INFORMATION

DESCRIPTION OPTIONS
PART NUMBER SUGGESTED SHIPPING
Pump Up Pump Down Cable Length Mounting Device LIST WEIGHT MOUNTING CLAMP IS
STANDARD
1003982 1003981 3 Meters Mounting Clamp Request Quote 0.58 kgs.

1006664 1006663 3 Meters Cable Weight Request Quote 1.42 kgs. BAGGED
PACKAGING IS
1003924 1003923 5 Meters Mounting Clamp Request Quote 0.79 kgs. STANDARD

1006666 1006665 5 Meters Cable Weight Request Quote 1.63 kgs.


ADDITIONAL CABLE
1005530 1005529 6 Meters Mounting Clamp Request Quote 0.88 kgs. LENGTH IS
AVAILABLE
1006668 1006667 6 Meters Cable Weight Request Quote 1.73 kgs.

1003926 1003925 10 Meters Mounting Clamp Request Quote 1.33 kgs.

1006670 1006669 10 Meters Cable Weight Request Quote 2.17 kgs.


Part numbers and pricing with plug available upon request.

UL Recognized for
Water & Sewage
SPECIFICATIONS
PUMPING RANGE: 18 cm to 91 cm (7 to 36 inches)

CABLE: flexible 16 gauge, 2 conductor SJOW (UL, CSA), water-resistant,


chlorinated polyethylene (CPE) OTHER INFORMATION
FLOAT: 7.75 cm diameter x 9.04 cm long, impact resistant, non-corrosive, PUMP DOWN is normally open contacts
PVC plastic for use in liquids up to 60oC (140oF) for emptying.

ELECTRICAL: PUMP UP is normally closed contacts


for filling.

DIRECT WIRING
Units used for direct wiring (without plug)
may be used in either 120 VAC or 230
VAC applications within specified amp
NOTE: This switch must be used with pumps that provide integral thermal ratings.
overload protection.

www.sjerhombus.com