EV ON-BOARD
EVO Series HIGH FREQUENCY Battery Chargers
EVO22KL
22kW EV/HEV ON-BOARD Charger
for Heavy Duty & Rugged Applications
APPLICATIONS FEATURES
EVO22KL charger series is a very versatile, safe, US & EU single-phase and three-phase AC input
high power density charger for On-Board electric
voltage range (120/208/230/240/380/400/420 Vac)
vehicle applications.
SAE J1772 & EN 61851 Compliance
With a simple firmware set-up the EVO22KL can
charge one or two battery pack independently. Its Active HVDC Interlock monitoring
flexible AC input port and constant power charging Efficient – η > 90%
feature provide a very effective Charging System,
compatible with all international power grids. High AC Input Power Factor (low reactive power)
AC/DC Galvanic Isolation assures a definitive safety
The EVO22KL has been successfully tested to
meet CE and E/e safety and performance separation between the vehicle and grid.
standards.
High IP protection rating (EN60529)
Outputs are short-circuit and reverse polarity
protected
ACCESSORIES
Fully CAN controlled (v2.0B )
PCA22K-02 Battery & Mains Cables (2 m.) SAE J1939 available
PCA22K-03 Battery & Mains Cables (3 m.)
PCA22K-04 Battery & Mains Cables (4 m.)
PCA22K-05 Battery & Mains Cables (5 m.)
EVO22KL Series Data Sheet – Rev. 04, Issue 15/11 Page 1 of 2
EDN GROUP S.r.l. Via dell'Artigianato, 8 – 20835 – Muggiò (MB) ITALY – TEL. +39 039 9402610 FAX +39 039 9461698
CONSULT TECHNICAL SALES FOR MORE DETAILED DATA SHEETS OR TECHNICAL MANUAL
e-mail: [email protected] web.site: www.edngroup.com
EV ON-BOARD
EVO Series HIGH FREQUENCY Battery Chargers
AC Input Data 1-phase 3-phase Δ 208V US 3-phase Υ 400V EU Units
AC Input Voltage Range REDUCED POWER 100 … 185 100 … 185 173 … 340 Vac
AC Input Voltage Range FULL POWER 185 … 265 185 … 265 340 … 460 Vac
Line Frequency 47...63 Hz
Max AC Input Current (each-phase) 96 56 32 Aac
Absorbed Maximum Apparent Power 22 kVA
Power Factor > 0,98
DC Ouputs Data EVO22KLR1 EVO22KLR2 EVO22KLR3 EVO22KLR4 Units
V01 HV Output Voltage (max) 100...420 125...500 160...670 210...840 Vdc
V01 HV Voltage Accuracy ±1 %
V01 HV Output Current (2x) 80 66 50 40 Adc
V01 HV Rated Output Power Max 20 kW
V01 HV Parameters control CAN v2.0B
General Data Units
Ambient Temperature - Operating -30...+85 degC
Ambient Temperature - Full performance -25...+65 degC
Power de-rating (from +65 to +85 degC) -5 % / degC
Heat Dissipation Liquid cooling (50:50% Glycol/Water, F>10lt/min, Tmax<55°C)
Coolant Pressure Loss @ 10lt/min < 200 mbar
Protection Degree IP67 / IP6K9K
Efficiency > 90 @ from 25% to Max load %
Control Interface CAN V2.0B (125/250/500Kbit/s, EXT/STD frame, ID's adaptable)
Standard Applied Units
General Requirements EN 61851-1; SAE J1455
EMC – Emission & Immunity ECE Regulation 10
SAFETY ECE Regulation 100; SAE J2344
Insulation resistance HVDC Output / PE: > 10MΩ @ 1000Vdc
Touch current < 3.5 mA
Chassis Ground Stud M8
Mechanical Data Units
Dimensions: Width x Depth x Height 550 x 354 x 200 mm
Weight 49 Kg
Case Material Aluminium
EVO22K
90
80
70
60
50
40
30
20
10
0
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Pout vs. Vout% [kW]
Iout (R1) vs. Vout% [amps]
Iout (R2) vs. Vout% [amps]
Iout (R3) vs. Vout% [amps]
Iout (R4) vs. Vout% [amps]
EVO22KL Series Data Sheet – Rev. 04, Issue 15/11 Page 2 of 2
EDN GROUP S.r.l. Via dell'Artigianato, 8 – 20835 – Muggiò (MB) ITALY – TEL. +39 039 9402610 FAX +39 039 9461698
CONSULT TECHNICAL SALES FOR MORE DETAILED DATA SHEETS OR TECHNICAL MANUAL
e-mail: [email protected] web.site: www.edngroup.com