0% found this document useful (0 votes)
12 views2 pages

Data Sheet Fusibre Chiller Ballenita

The document provides technical data for FNQ 13/32˝ x 1-1/2˝ 500Vac time-delay supplemental fuses, including specifications, ratings, and typical applications. It highlights features such as color coding for voltage rating and fiber tube construction, along with agency certifications like UL and CSA. Additionally, it lists recommended fuse blocks and holders, as well as catalog numbers for various amp ratings.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
12 views2 pages

Data Sheet Fusibre Chiller Ballenita

The document provides technical data for FNQ 13/32˝ x 1-1/2˝ 500Vac time-delay supplemental fuses, including specifications, ratings, and typical applications. It highlights features such as color coding for voltage rating and fiber tube construction, along with agency certifications like UL and CSA. Additionally, it lists recommended fuse blocks and holders, as well as catalog numbers for various amp ratings.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Effective February 2016

Technical Data 1012 Supersedes April 2014

FNQ 13⁄32˝ x 1-1⁄2˝ 500Vac time-delay


supplemental fuses
Catalog symbol / color code: Dimensions - in (mm)
• FNQ - Orange (500Vac maximum voltage)

Description: 1.5"
0.41"
(10.3) (38.1)
Bussmann® series time-delay FNQ supplemental
fuses. For superior protection, upgrade to FNQ-R
Features
Class CC fuses. See data sheet no. 1014.
• Color coded for 500Vac maximum voltage rating
Specifications: • Fiber tube construction
Ratings • Nickel-plated brass endcaps

Fuse Interrupting Rating Agency Typical applications


Amp at Rated Voltage Information
• Motor control transformers
Range 500Vac UL CSA
• Circuits with in-rush currents.
1/10 to 30 10kA X X

Agency information Recommended fuse blocks/fuse holders


500Vac Catalog symbol Description Data sheet no.#
• UL® Listed, Std. 248-14, Guide JDYX,
1/10 to 30A
File E19180 Blocks

• CSA® Certified: C22.2 No. 248.14, 1-, 2- and 3-pole modular


BMM blocks with optional 10235
Class 1422-01, File 53787, HRC-MISC covers
• CE BM 1-, 2- and 3-pole blocks 1104
• RoHS compliant* DIN-rail holders / switches
CCP-_-30M 1-, 2- and 3-pole switch 1157
* FNQ-1/8 not RoHS compliant.
CHM 1-, 2- and 3-pole 3185

Catalog numbers (amps) Optima NG 3-Pole protection module 1109

FNQ-1/10 FNQ-8/10 FNQ-3-2/10 FNQ-9 Optima 3-Pole holder 1102


Optima 3-Pole holder + switch 1103
FNQ-1/8 FNQ-1 FNQ-3-1/2 FNQ-10
Panel mount holders
FNQ-15/100 FNQ-1-1/8 FNQ-4 FNQ-12
HPM and HPM-D 1-Pole holder 2112
FNQ-3/16 FNQ-1-1/4 FNQ-4-1/2 FNQ-14
HPC-D 1-Pole holder 2109
FNQ-2/10 FNQ-1-1/2 FNQ-5 FNQ-15
HPS2 2-Pole holder 2140
FNQ-1/4 FNQ-1-6/10 FNQ-5-6/10 FNQ-20
HPF, HPF-C and
1-Pole holder 2114
FNQ-3/10 FNQ-2 FNQ-6 FNQ-25 HPF-WT
FNQ-4/10 FNQ-2-1/4 FNQ-6-1/4 FNQ-30 HPS 1-Pole holder 2113
FNQ-1/2 FNQ-2-1/2 FNQ-7 HPG and HPD 1-Pole holder 2108

FNQ-6/10 FNQ-3 FNQ-8 In-line holders


HEB 1-Pole holder 2127
Carton quantity
HEX 2-Pole holder 2126

Amps Qty. Fuseclips

1/10 to 30 10 1A3400, 5956 and


PCB fuseclips 2132
5960
Fuse covers
SAMI-7 Finger-safe fuse cover 1204
Technical Data 1012 FNQ Series
Effective February 2016 500Vac Time-Delay Supplemental Fuses

Time-current characteristic curves – average melt

3-2/10

25
30
1-6/10

10

20
15
Amp Rating

5
6
7
4
100
2 Amp Rating
1

300
1/2

100

10

10
Time in Seconds

Time in Seconds

1
1

0.1 0.1

0.01
200
100
20
10
0.6
1

0.01
Current in Amps
200
10
6

100

600
20

Current in Amps

The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document
are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the
end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue
or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this
bulletin. Once a product has been selected, it should be tested by the user in all possible applications.

Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
Eaton.com

Bussmann Division
114 Old State Road
Ellisville, MO 63021 Eaton and Bussmann are valuable trademarks
United States of Eaton in the U.S. and other countries. You
Eaton.com/bussmannseries are not permitted to use the Eaton trademarks
without prior written consent of Eaton.
© 2016 Eaton Follow us on social media to get the
All Rights Reserved UL is a registered trademark of the latest product and support information.
Printed in USA Underwriters Laboratories, Inc.
Publication No. 1012 — BU-SB14286 CSA is a registered trademark of the Canadian
February 2016 Standards Group.

You might also like