0% found this document useful (0 votes)
37 views2 pages

SPM32 Data Sheet V1

The SPM32 Multifunction Power Meter is designed for panel and DIN rail mounting, suitable for distribution systems under 850kV, and provides true RMS measurements with high accuracy. It features a range of monitoring capabilities including voltage, current, power factors, harmonic analysis, and setpoint alarms for various electrical parameters. The device supports MODBUS-RTU communication and offers optional relay outputs and status inputs.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
37 views2 pages

SPM32 Data Sheet V1

The SPM32 Multifunction Power Meter is designed for panel and DIN rail mounting, suitable for distribution systems under 850kV, and provides true RMS measurements with high accuracy. It features a range of monitoring capabilities including voltage, current, power factors, harmonic analysis, and setpoint alarms for various electrical parameters. The device supports MODBUS-RTU communication and offers optional relay outputs and status inputs.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 2
SPM32 Multifunction Power Meter x » Suit for Panel mount and DIN Rail Mount installation > Suitfor distribution system under 850kV (PT value settable ) > True RMS measuring parameters > Setpoint alarm for over / under limit > 31 Harmonic analysis, THD > Status input & relay output function (Optional) > High accuracy, class 0.58 for kWh > Small size : 72°72mm > One RSAB5, support MODBUS-RTU protocol sPMs2 Panel Mount SPM32-DR: DIN Rall Mount (without display) Basic Function ‘SPM32 measure and display real-time parameters: > Valtage—Ua, Ub, Uc, Uab, Ube, Uca, ULL avg. ULN avg, > Current—Ia, Ipc, I, Lave. > Current Unbalance Rate -I unbal » clive Power ~ Pa, Pb, Po, SP » Reactive Power —Qa, Qb, Qc, 3 > Apparent Power—Sa, Sb.Se, 3S > Power Factor—PFa, PFb, PFc, )PF eee ec > Frequency-F > Active Energy—Total kWh (import/export) > Reactive Energy Total kvarh (import / export) > Apparent Energy ~ Total KVAN > Demand (1, P) and Max. Demand Record for |, P > 31% harmonic, THD, THOu, THDi, > Selpoint Alarm — over voltage, under voltage, over current, under current, frequency too high, frequency too low, overload, over demand, phase loss, status input OFF For SPMa2 R | 2relay outpurs (Panet Mount) [5 | 2 status inputs (Wet contact) For SPM32:0R (oration | | Stas Inpus (wet contac) | Technical Specification Connection Mode | 3 phase 3 wires, 8 prase 4 wires Metering “roe RMS, # sec reftesh time Input Rated curenk Aor 1A Rated vtago: 57V ~S00VIphN),35Ke-6SHe ‘Status input Rated wotage 220V, 2 channel ative sas (tional) input {eptona Uwe than 80 ie apen higher than 478V is lose Max ints 3000 Relay Output | Rated contact capacity (optional) [AC 250VI5A or DC 3A Power Supply | AG 85-255 or DC 100-300 Power Loss “ava Power Frequency Withstand Voltage | AC 2KViminute Insulation Resistance > 10080 Impulse Withstand Voltage Kv Ty hitp:|enpmac.com.cn ‘Communication | RS486 sara, Moabus-RTU, Adoress: 1-247 ‘audrat: 4900, 9600, 1920005 Dimension Panel Mount 72°72*7omm (Wx) Dina Mount 72°72°77 2mm 1P Index 1P52 (Font pans) and 1P20 (ese) Operating temperature: 100 — +85 Umi operating temperature: 25°C ~=55%° — Storage temperature: 40 —+70 Environment | Humid 52-88% RH, non-condensing Elecvortai dacharg inmunty test IEC 81000-42 Levels Raciatd imma test Standard (EMC) | Sctrealton vars Electrical fast Vanslentburst immunity test TEC 61000-4-4,Level 4 ‘Suge immu os (1, 260ys~-8/204s) TEC 51000-45 Level 4 FF fol immunity inducod mass Te ces000-46, Lavel 3 Measurement Parameter ‘Accuracy Measuring Range Voltage 02% ‘10V-500V (PT secondary side) Current 02% ‘5A or 1A (5%4-120% of rating) (CT secondary sid) Power factor 05% 71.000-1.000 . ok Per phase: 0- 1 25MW Reactive power 10% ‘Apparent power 10% ‘Active energy 05% 0 98,999,098,9 kWh Reactive energy 20% (0-99,900,099.9 Kvarh ‘Apparent energy 2.0% (0 99,999,990.9 KVAR ‘Three-phase current unbalance 10% 0% 100% Harmonic ass B (0%-700% | Dimension & Installation ‘SPM32: Panel Mount | SPm32-DR: DIN Rail Mount Unit: mm Eton R | 2relay outputs ! S| 2otatus inputs (Wet contact | S| 4 status inputs seus j | sewsz0R ya | ga | vi BA ve | 1 v2 | 1A ‘SPM32-RS-V1, it means the device provides basic measuring function, one RS485 por, 2 status inputs, 2 relay outputs. Rated input courent 5A,

You might also like