Flowfit CYA27
Flowfit CYA27
Technical Information
Flowfit CYA27
Modular flow assembly for multiparameter
measurements
Measuring system A complete measuring system may contain up to six different sensors and consists, for example, of
the following:
• Flow assembly Flowfit CYA27
• At least one sensor, e.g CCS51D for the measurement of free chlorine
• At least one measuring cable, e.g. CYK10
• Transmitter, e.g. Liquiline CM44x or CM44xR with latest software
• Optional:
• pH sensors, e.g. Memosens CPS31E
• ORP sensors, e.g. Memosens CPS16E
• Conductivity sensor CLS82E
• Oxygen sensors, e.g. COS22E
• Transmitter, e.g. Liquiline Compact CM82
• Multiparameter handheld device Liquiline Mobile CML18
• Extension cable CYK11
• Sampling valve on assembly if using modules for disinfection and conductivity
• Flow switch or flowmeter
• Status lighting
5 3
A0043060
Energy supply
Cable specification Cable accessories 10 m (32.8 ft), M12 socket straight, 5-pin version
Cable accessories Ex (US) Cl.1 Div.2 cable, 10 m (32.8 ft), M12 socket straight, 4-pin version
2 Endress+Hauser
Flowfit CYA27
Performance characteristics
Reference operating 20 °C (68 °F)
conditions
Mounting
Orientation The assembly is designed for mounting on panels, walls, level surfaces, masts or railings. The only
permitted orientation of the assembly is horizontal, → 3.
The prescribed orientation of the assembly may limit the installation of certain sensors. e,g,
upside-down installation.
NOTICE
Direct sunlight or UV light
‣ Appropriate precautions should be taken at the installation site to protect the assembly from
direct sunlight or other sources of UV radiation.
At ambient temperatures below 0 °C (32 °F), the medium can freeze particularly with low flow
conditions. The medium temperature and the flow volume must be adjusted accordingly. It may
be necessary to insulate the supply and return lines and install the assembly in an additional
enclosure. This must be fitted with a separate heating system if necessary.
Direct wall mounting The assembly can be screwed directly onto the wall using two holes provided in the inlet and outlet
module.
Direct mounting on the wall is permitted for assemblies with one to a maximum of three
modules.
Number of modules 1 2 3
A0048283
Endress+Hauser 3
Flowfit CYA27
Mounting the assembly with With the wall holder, it is possible to select up to six modules. It is then possible to remove individual
wall holder modules while the rest of the assembly remains securely in the holder. Different drill holes allow, for
example, the use of the Flowfit CCA250 hole pattern.
Optional accessories, consisting of a wall holder with securing clips for assemblies with 1 to 6
modules.
The drill holes (hatched in graphic) correspond to those of assembly CCA250, which can be
reused.
)
(4x
70 (2.76)
Ø9
7
(0
153.6 (6.05)
.2
80 (3.15)
70 (2.76)
8)
)
( 4x
Ø9
80 (3.15)
240 (9.45)
320 (12.6) 94 (3.70)
A0047945
A0043207 A0043208
With six modules, three securing clips are required for increased
stability.
Environment
Ambient temperature –20 to 60 °C (–4 to 140 °F)
At ambient temperatures below 0 °C (32 °F), the medium temperature must be at least 5 °C (41 °F)
and the supply and return lines must be insulated.
4 Endress+Hauser
Flowfit CYA27
T[°F] T[°C]
140 60
122 50
104 40
A
86 30
68 20
50 10
41 5
32 0
-20 0 20 40 60 T[°C]
A Medium temperature
B Ambient temperature
Process
Process temperature range 0 to 60 °C (32 to 140 °F), non-freezing
Pressure/temperature graph
p [psi] p [bar]
58 4
44 3
A
29 2
15 1
0 0
0 10 20 30 40 50 60 70 T[°C]
32 50 68 86 104 122 140 158 T[°F]
B
A0044367
6 Pressure/temperature ratings
A Process pressure
B Medium temperature
pH range pH1 to 12
Endress+Hauser 5
Flowfit CYA27
Above the specified flow rate, the pressure in the assembly may exceed the specification limits
of the sensors.
Mechanical construction
Dimensions
A B C
221.4 (8.72)
212.6 (8.37)
D E F
52.5 (2.07) 60 (2.36)
249.5 (9.82)
155 (6.10)
6 Endress+Hauser
Flowfit CYA27
175 (6.89)
155 (6.10) A0043194
The minimum mounting distance required to remove the sensor(s) is 175 mm (6.9 in).
Endress+Hauser 7
Flowfit CYA27
Order information
Product page www.endress.com/cya27
For many products, you also have the option of downloading CAD or 2D drawings of the
selected product version.
5. CAD: Open this tab.
The drawing window is displayed. You have a choice between different views. You can
download these in selectable formats.
Accessories
The following are the most important accessories available at the time this documentation was
issued.
Listed accessories are technically compatible with the product in the instructions.
1. Application-specific restrictions of the product combination are possible.
Ensure conformity of the measuring point to the application. This is the responsibility of the
operator of the measuring point.
2. Pay attention to the information in the instructions for all products, particularly the technical
data.
3. For accessories not listed here, please contact your Service or Sales Center.
8 Endress+Hauser
Flowfit CYA27
150 (5.91)
172 (6.77)
!7 (0.28)
!10.5 (0.41)
93.5 (.68) 130 (5.12)
A0053037
! 9.7 (0.38)
! 4.2 (0.17)
13.5 (0.53)
22 (0.87)
A0053047
Endress+Hauser 9
Flowfit CYA27
Disinfection sensors
Memosens CCS50E
• Membrane-covered amperometric sensor for chlorine dioxide
• With Memosens technology
• Product Configurator on the product page: www.endress.com/ccs50e
Technical Information TI01353C
Memosens CCS51
• Sensor for measuring free available chlorine
• Product Configurator on the product page: www.endress.com/ccs51 or
Technical Information TI01424C (CCS51)
Memosens CCS51E
• Sensor for measuring free available chlorine
• Product Configurator on the product page: www.endress.com/ccs51e
Technical Information TI01423C
Memosens CCS55E
• Sensor for measuring free bromine
• With Memosens technology
• Product Configurator on the product page: www.endress.com/ccs55e
Technical Information TI01423C
Memosens CCS58E
• Sensor for determining ozone
• With Memosens technology
• Product Configurator on the product page: www.endress.com/ccs58e
Technical Information TI01583C
pH sensors
Memosens CPS31E
• pH sensor for standard applications in drinking water and swimming pool water
• Digital with Memosens 2.0 technology
• Product Configurator on the product page: www.endress.com/cps31e
Technical Information TI01574C
Memosens CPS11E
• pH sensor for standard applications in process and environmental engineering
• Digital with Memosens 2.0 technology
• Product Configurator on the product page: www.endress.com/cps11e
Technical Information TI01493C
Memosens CPS41E
• pH sensor for process technology
• With ceramic junction and KCl liquid electrolyte
• Digital with Memosens 2.0 technology
• Product Configurator on the product page: www.endress.com/cps41e
Technical Information TI01495C
ORP sensors
Orbisint CPS12D / CPS12
• ORP sensor for process technology
• Product Configurator on the product page: www.endress.com/cps12d or www.endress.com/cps12
Technical Information TI00367C
10 Endress+Hauser
Flowfit CYA27
Memosens CPS76E
• pH/ORP sensor for process technology
• Digital with Memosens 2.0 technology
• Product Configurator on the product page: www.endress.com/cps76e
Technical Information TI01601C
Conductive sensor
Memosens CLS82E
• Hygienic conductivity sensor
• Digital with Memosens 2.0 technology
• Product Configurator on the product page: www.endress.com/cls82e
Technical Information TI01529C
Oxygen sensors
Memosens COS22E
• Hygienic amperometric oxygen sensor with maximum measurement stability over multiple
sterilization cycles
• Digital with Memosens 2.0 technology
• Product Configurator on the product page: www.endress.com/cos22e
Technical Information TI01619C
Memosens COS81E
• Hygienic optical oxygen sensor with maximum measurement stability over multiple sterilization
cycles
• Digital with Memosens 2.0 technology
• Product Configurator on the product page: www.endress.com/cos81e
Technical Information TI01558C
Endress+Hauser 11
*71626365*
71626365
www.addresses.endress.com