0% found this document useful (0 votes)
51 views12 pages

Flowfit CYA27

The Flowfit CYA27 is a modular flow assembly designed for multiparameter measurements in various water applications, allowing for the measurement of up to six parameters with minimal water loss. It features integrated flow monitoring, easy maintenance options, and flexible installation capabilities. The assembly is suitable for a range of environments and comes with various accessories for enhanced functionality.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
51 views12 pages

Flowfit CYA27

The Flowfit CYA27 is a modular flow assembly designed for multiparameter measurements in various water applications, allowing for the measurement of up to six parameters with minimal water loss. It features integrated flow monitoring, easy maintenance options, and flexible installation capabilities. The assembly is suitable for a range of environments and comes with various accessories for enhanced functionality.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

TI01559C/07/EN/03.

23-00 Products Solutions Services


71626365
2023-08-25

Technical Information
Flowfit CYA27
Modular flow assembly for multiparameter
measurements

Application Your benefits


Flowfit CYA27 is a flow assembly for multiparameter • Maximum flexibility: The modular design of the assembly
measurements mainly in bypass installations for: means that it can be adapted perfectly to the process
• Drinking water requirements. Up to 6 parameters can be measured. Flexible
• Process water installation options enable optimum sensor positioning for
• Saltwater accurate measurements.
• Swimming pool water • Minimum water loss: Using the Flowfit CYA27, sensors
require a sample flow of only 5 l/h (1.32 gal/h) for a precise
measurement. This means that only a very small volume of
water needs to be discarded.
• Reliable measurement: Integrated flow monitoring ensures
that the measurement is always ready for operation. LEDs
indicate whether the flow rate is correct and facilitate a
quick response in the event of errors.
• Easy to maintain: The optional cleaning and dosing module
enables automatic cleaning cycles.
Flowfit CYA27

Function and system design


Operating principle The CYA27 flow assembly can be used for reliable measurements for the purpose of liquid analysis.
The measurement of different parameters, such as disinfection, pH, ORP, conductivity and oxygen is
possible. An additional flow measurement enables safe and reliable operation of the measuring
point.

Measuring system A complete measuring system may contain up to six different sensors and consists, for example, of
the following:
• Flow assembly Flowfit CYA27
• At least one sensor, e.g CCS51D for the measurement of free chlorine
• At least one measuring cable, e.g. CYK10
• Transmitter, e.g. Liquiline CM44x or CM44xR with latest software
• Optional:
• pH sensors, e.g. Memosens CPS31E
• ORP sensors, e.g. Memosens CPS16E
• Conductivity sensor CLS82E
• Oxygen sensors, e.g. COS22E
• Transmitter, e.g. Liquiline Compact CM82
• Multiparameter handheld device Liquiline Mobile CML18
• Extension cable CYK11
• Sampling valve on assembly if using modules for disinfection and conductivity
• Flow switch or flowmeter
• Status lighting

5 3

A0043060

1 Example of a measuring system


1 Transmitter Liquiline CM44x or CM44xR
2 Measuring cable CYK10
3 pH sensor, e.g. CPS31E
4 Flow assembly Flowfit CYA27
5 Disinfection sensor CCS5xD (membrane-covered, ⌀25 mm (0.98 in)), e.g. CCS51D

Energy supply
Cable specification Cable accessories 10 m (32.8 ft), M12 socket straight, 5-pin version
Cable accessories Ex (US) Cl.1 Div.2 cable, 10 m (32.8 ft), M12 socket straight, 4-pin version

2 Endress+Hauser
Flowfit CYA27

Performance characteristics
Reference operating 20 °C (68 °F)
conditions

Mounting
Orientation The assembly is designed for mounting on panels, walls, level surfaces, masts or railings. The only
permitted orientation of the assembly is horizontal, →  3.
The prescribed orientation of the assembly may limit the installation of certain sensors. e,g,
upside-down installation.

Installation instructions NOTICE


Ambient conditions
‣ The ambient conditions of the technical specification of the assembly and sensors must be
observed at the installation site.
‣ Take technical precautions, such as installing in an additional enclosure, to protect the
measuring point from ambient or environmental influences (e.g. temperature, pollution).

NOTICE
Direct sunlight or UV light
‣ Appropriate precautions should be taken at the installation site to protect the assembly from
direct sunlight or other sources of UV radiation.

At ambient temperatures below 0 °C (32 °F), the medium can freeze particularly with low flow
conditions. The medium temperature and the flow volume must be adjusted accordingly. It may
be necessary to insulate the supply and return lines and install the assembly in an additional
enclosure. This must be fitted with a separate heating system if necessary.

Direct wall mounting The assembly can be screwed directly onto the wall using two holes provided in the inlet and outlet
module.
Direct mounting on the wall is permitted for assemblies with one to a maximum of three
modules.

Number of modules 1 2 3

Spacing between drill 120 (4.73) 180 (7.09) 240 (9.45)


holes
mm (in)
M6

240 (9.45) 73 (2.87)

A0048283

2 Direct wall mounting. Engineering unit: mm (in)

Endress+Hauser 3
Flowfit CYA27

Mounting the assembly with With the wall holder, it is possible to select up to six modules. It is then possible to remove individual
wall holder modules while the rest of the assembly remains securely in the holder. Different drill holes allow, for
example, the use of the Flowfit CCA250 hole pattern.
Optional accessories, consisting of a wall holder with securing clips for assemblies with 1 to 6
modules.
The drill holes (hatched in graphic) correspond to those of assembly CCA250, which can be
reused.

)
(4x
70 (2.76)

Ø9

7
(0

153.6 (6.05)
.2

80 (3.15)
70 (2.76)
8)
)
( 4x
Ø9

80 (3.15)
240 (9.45)
320 (12.6) 94 (3.70)

A0047945

3 Dimensions of wall holder. Engineering unit: mm (in)

A0043207 A0043208

4 2 securing clips for 1 to 5 modules  5 3 securing clips for 6 modules

With six modules, three securing clips are required for increased
stability.

Environment
Ambient temperature –20 to 60 °C (–4 to 140 °F)
At ambient temperatures below 0 °C (32 °F), the medium temperature must be at least 5 °C (41 °F)
and the supply and return lines must be insulated.

4 Endress+Hauser
Flowfit CYA27

T[°F] T[°C]

140 60

122 50

104 40
A
86 30

68 20

50 10
41 5
32 0
-20 0 20 40 60 T[°C]

-4 32 68 104 140 T[°F]


B
A0044116

A Medium temperature
B Ambient temperature

Storage temperature –20 to 60 °C (–4 to 140 °F)

Degree of protection • Flow switch: IP67


• Status indication light: IP66/67

Process
Process temperature range 0 to 60 °C (32 to 140 °F), non-freezing

Process pressure range 0 to 4 bar (0 to 58 psi) relative

Pressure/temperature graph
p [psi] p [bar]

58 4

44 3
A
29 2

15 1

0 0
0 10 20 30 40 50 60 70 T[°C]
32 50 68 86 104 122 140 158 T[°F]
B
A0044367

6 Pressure/temperature ratings
A Process pressure
B Medium temperature

pH range pH1 to 12

Process connections G 1/4" (ISO 228)

Endress+Hauser 5
Flowfit CYA27

Flow Recommended flow range


5 l version 5 to 8 l/h (1.32 to 2.11 gal/h)

30 l version 30 to 40 l/h (7.92 to 10.46 gal/h)

Critical upper limits


5 l version 40 l/h (10.56 gal/h)

30 l version 80 l/h (21.13 gal/h)

Above the specified flow rate, the pressure in the assembly may exceed the specification limits
of the sensors.

Mechanical construction
Dimensions
A B C
221.4 (8.72)
212.6 (8.37)

285 (11.22) 345 (13.58) 225 (8.86)

D E F
52.5 (2.07) 60 (2.36)
249.5 (9.82)
155 (6.10)

165 (6.50) 165 (6.50)


A0045635

7 Dimensions. Engineering unit: mm (in)


A Disinfection, pH and flow display version with sampling valve, status lighting and flow switch or flow
measurement
B Disinfection, pH, ORP and flow display version with sampling valve, status lighting and flow switch or flow
measurement
C Disinfection and flow display version with sampling valve, status lighting and flow switch or flow
measurement
D Disinfection version with sampling valve
E pH, ORP or oxygen version
F Conductivity version with sampling valve

6 Endress+Hauser
Flowfit CYA27

175 (6.89)
155 (6.10) A0043194

8 Mounting distance. Engineering unit: mm (in)

The minimum mounting distance required to remove the sensor(s) is 175 mm (6.9 in).

Weight Number of modules 1 2 3 4 5 6

Weight in kg (lb) 0.9 kg 1.5 kg 2.1 kg 2.7 kg 3.3 kg 3.8 kg


(1.98 lb) (3.31 lb) (4.63 lb) (5.95 lb) (7.28 lb) (8.38 lb)
 max. weight depending
on version without
sensors

Wall mounting accessories: 1.3 kg (2.87 lb)


Pipe mounting accessories (incl. wall bracket): 2.2 kg (4.85 lb)

Materials In contact with medium


Assembly: PMMA (modules)
PVDF for inlet and outlet module
Seals: FPM (FKM)
Black compound in conjunction with PVDF
Green compound in conjunction with PVC
Plugs, adapters, valves: PVC/POM or PVDF
Floats: Titanium
Flowmeter: PVDF
Equipotential bonding connection: 1.4404/1.4571 (316L/316TI) (stainless Cr-Ni steel)

Not in contact with medium


Clips, wall holder, inlet and outlet module PBT-GF20/GF30

Materials not in contact with the medium


Obligation to provide information in accordance with Art. 33 REACH regulation (EU no.
1907/2006):
The PVC used (hard) contains more than 0.1% of the following substance: dioctyltin compounds
(DOTE) CAS number: 15571-58-1. No special precautions are required when handling the item,
since the substance is firmly embedded in the plastic and is not released if used as intended.

Endress+Hauser 7
Flowfit CYA27

Certificates and approvals


Current certificates and approvals for the product are available at www.endress.com on the relevant
product page:
1. Select the product using the filters and search field.
2. Open the product page.
3. Select Downloads.

Order information
Product page www.endress.com/cya27

Product Configurator 1. Configure: Click this button on the product page.


2. Select Extended selection.
 The Configurator opens in a separate window.
3. Configure the device according to your requirements by selecting the desired option for each
feature.
 In this way, you receive a valid and complete order code for the device.
4. Accept: Add the configured product to the shopping cart.

For many products, you also have the option of downloading CAD or 2D drawings of the
selected product version.
5. CAD: Open this tab.
 The drawing window is displayed. You have a choice between different views. You can
download these in selectable formats.

Scope of delivery The scope of delivery comprises:


• Assembly including enclosed accessories in the version ordered
• Operating Instructions
• Manufacturer's Declaration

Accessories
The following are the most important accessories available at the time this documentation was
issued.
Listed accessories are technically compatible with the product in the instructions.
1. Application-specific restrictions of the product combination are possible.
Ensure conformity of the measuring point to the application. This is the responsibility of the
operator of the measuring point.
2. Pay attention to the information in the instructions for all products, particularly the technical
data.
3. For accessories not listed here, please contact your Service or Sales Center.

Device-specific accessories Peristaltic dosing pump


The dosing pump is a peristaltic dosing pump with stepper motor drive for dosing liquid media in
commercial and industrial applications.
Volumes of 0.5 ml/h - 10000 ml/h can be dosed with the available pump hose dimensions. The
pump has multiple operating modes as well as a 2x16 character display for indicating functions and
parameters.
Thanks to ergonomic control, the parameters and functions can be adjusted clearly during operation.

8 Endress+Hauser
Flowfit CYA27

150 (5.91)
172 (6.77)
!7 (0.28)
!10.5 (0.41)
93.5 (.68) 130 (5.12)

A0053037

9 Pump dimensions. Unit of measurement mm (in)


150 (5.91)
100 (3.94)

! 9.7 (0.38)
! 4.2 (0.17)
13.5 (0.53)
22 (0.87)

13.5 (0.53) 4 (0.16)


5 (0.20)
66.5 (2.62)
93.5 (3.68)

A0053047

 10 Drill plate for wall holder, dimensions

Kit CYA27 dosing pump 0.1-22 ml/min: order no. 71621627


Kit CYA27 pump maintenance 0.1-22 ml/min: order no. 71621629
Kit CYA27 dosing pump 1-200 ml/min: order no. 71610954
Kit CYA27 pump maintenance 1-200 ml/min: order no. 71610955
Kit CYA27 dosing pump suction lance: order no. 71610956

Endress+Hauser 9
Flowfit CYA27

Disinfection sensors
Memosens CCS50E
• Membrane-covered amperometric sensor for chlorine dioxide
• With Memosens technology
• Product Configurator on the product page: www.endress.com/ccs50e
Technical Information TI01353C

Memosens CCS51
• Sensor for measuring free available chlorine
• Product Configurator on the product page: www.endress.com/ccs51 or
Technical Information TI01424C (CCS51)

Memosens CCS51E
• Sensor for measuring free available chlorine
• Product Configurator on the product page: www.endress.com/ccs51e
Technical Information TI01423C

Memosens CCS55E
• Sensor for measuring free bromine
• With Memosens technology
• Product Configurator on the product page: www.endress.com/ccs55e
Technical Information TI01423C

Memosens CCS58E
• Sensor for determining ozone
• With Memosens technology
• Product Configurator on the product page: www.endress.com/ccs58e
Technical Information TI01583C

pH sensors
Memosens CPS31E
• pH sensor for standard applications in drinking water and swimming pool water
• Digital with Memosens 2.0 technology
• Product Configurator on the product page: www.endress.com/cps31e
Technical Information TI01574C

Memosens CPS11E
• pH sensor for standard applications in process and environmental engineering
• Digital with Memosens 2.0 technology
• Product Configurator on the product page: www.endress.com/cps11e
Technical Information TI01493C

Memosens CPS41E
• pH sensor for process technology
• With ceramic junction and KCl liquid electrolyte
• Digital with Memosens 2.0 technology
• Product Configurator on the product page: www.endress.com/cps41e
Technical Information TI01495C

ORP sensors
Orbisint CPS12D / CPS12
• ORP sensor for process technology
• Product Configurator on the product page: www.endress.com/cps12d or www.endress.com/cps12
Technical Information TI00367C

10 Endress+Hauser
Flowfit CYA27

pH and ORP combined sensors


Memosens CPS16E
• pH/ORP sensor for standard applications in process technology and environmental engineering
• Digital with Memosens 2.0 technology
• Product Configurator on the product page: www.endress.com/cps16e
Technical Information TI01600C

Memosens CPS76E
• pH/ORP sensor for process technology
• Digital with Memosens 2.0 technology
• Product Configurator on the product page: www.endress.com/cps76e
Technical Information TI01601C

Conductive sensor
Memosens CLS82E
• Hygienic conductivity sensor
• Digital with Memosens 2.0 technology
• Product Configurator on the product page: www.endress.com/cls82e
Technical Information TI01529C

Oxygen sensors
Memosens COS22E
• Hygienic amperometric oxygen sensor with maximum measurement stability over multiple
sterilization cycles
• Digital with Memosens 2.0 technology
• Product Configurator on the product page: www.endress.com/cos22e
Technical Information TI01619C

Memosens COS81E
• Hygienic optical oxygen sensor with maximum measurement stability over multiple sterilization
cycles
• Digital with Memosens 2.0 technology
• Product Configurator on the product page: www.endress.com/cos81e
Technical Information TI01558C

Endress+Hauser 11
*71626365*
71626365

www.addresses.endress.com

You might also like