0% found this document useful (0 votes)
12 views4 pages

Advantec MFS

The document discusses the importance of sample preparation in soil analysis, highlighting the need for effective filtration systems due to increasing heavy metal pollution from industrialization. ADVANTEC MFS, Inc. offers a variety of high-quality filters and systems for sample preparation, including mixed cellulose esters, qualitative and quantitative filter papers, glass fiber filters, and syringe filter units. These products are designed to ensure optimal results in laboratory testing by facilitating efficient extraction and clarification processes.

Uploaded by

Ya Sinchan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
12 views4 pages

Advantec MFS

The document discusses the importance of sample preparation in soil analysis, highlighting the need for effective filtration systems due to increasing heavy metal pollution from industrialization. ADVANTEC MFS, Inc. offers a variety of high-quality filters and systems for sample preparation, including mixed cellulose esters, qualitative and quantitative filter papers, glass fiber filters, and syringe filter units. These products are designed to ensure optimal results in laboratory testing by facilitating efficient extraction and clarification processes.

Uploaded by

Ya Sinchan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Filters and systems for sample preparation

The earth is a complex matrix of physical and chemical characteristics.


This dynamic composition is critical to all aspects of life, from food
production to environmental ecosystems. As the human population grows
and industrialization increases, mother earth becomes an even more
precious resource. Heavy industry, both past and present, is a large source
of heavy metal pollutants that can become a health risk to man, animals,
and plants. Fertilizers, pesticides, and other pollutants permeate through
soil and find their way into groundwater. These problems are on the rise
and so the need to monitor the soil ecosystem becomes a growing
importance. Establishing a soil profile is an intricate and time consuming
process but many industries such as agriculture, mining, land development,
and land remediation share this need.

ADVANTEC MFS, Inc. offers a large array of high quality products for sample
preparation. Many of the most widely used methods of testing require a
soil sample to undergo a liquid extraction or digestion process. The extract
is then filtered and analyzed by a specific instrument for the analyte of
interest. Sample preparation for instrumental analysis is a critical step and
should not be overlooked. Using high quality products upstream, ensures
the best possible results downstream.
A nalytical methods and procedures are validated by the laboratory. There are various
techniques for any one test. Whichever particular variation is selected, the principle is the
same: separation of the compounds in the sample via extraction, often-times sample
clarification by filtration, followed by analysis of the filtrate with the appropriate detector
selected for the compounds of interest.

TE TEST METHOD APPLICATION DESCRIPTION ADVANTEC FILTER REFERENCE


GRADE GRADE
USEPA 1311 Toxicity Characteristic Leaching Procedure(TCLP) GF75 What GF/F
USEPA 1310B Extraction Procedure(EP) Toxicity Test GC90 Milli AP15
GS25 Milli AP20
DP70 Milli AP25
A045A_ (MCE 0.45) Milli HAWP
USEPA 1312 Synthetic Precipitation Leaching Procedure(SPLP) GF75 What GF/F
USGS FLT 5-D3 Field Leach Test(FLT) 25AS045AN
USEPA 1664A Oil & Grease No.5B What 40
(ASTM5520B)
NV DEP, 1996 Meteoric Water Mobility Procedure(MWMP) A045A_ (MCE 0.45)
USEPA 3050B Acid Digestion Sediments/Sludges/Soils No.5A What 41
USEPA 8151A Chlorinated Herbicides No.1 What 1
USEPA 1668B Chlorinated Biphenyl Congeners GD120 What GF/D
NCR-13 P, K, Mg, Ca, Zn, Fe, Cu, B, S, Cl⁻ No.5C, 6, 231 What 42, 2
NCR-13 Mn No.1 What 1

Filters for Sample Preparation

M ixed Cellulose Esters(MCE) membranes are highly porous filters that offer superior flow
rates. Advantec MCE membranes are Triton-free and biologically inert. They have a broad
range of laboratory applications from sample clarification to sterilizing biological fluids.
Advantec offers a wide selection of pore sizes, colors, diameters, plain or gridded, and sterile
or non-sterile.

Pore Size, Color/ Sterile Diameter, Quantity Catalog #


µm Surface mm per pack
0.45 White/Plain No 47 100 A045A047A
0.45 White/Plain No 142 25 A045A142C

Advantec offers a variety of membrane polymers, pore sizes, and diameters. Please see
our product catalog for the complete selection.
Q ualitative and Quantitative Filter Papers are manufactured from
100% alpha cotton cellulose of the highest quality. Advantec
quantitative grades are double acid washed then rinsed in ultrapure
water. Our long-established quality control measures ensure the best
product consistency, reproducibility, and superior performance. Advantec
offers the cleanest papers on the market.

Type Grade Particle Thickness, Weight, Flow Time*


Retention (µm) mm g/m2 (sec)
Qualitative No.1 Course (6) 0.20 90 Fast (45)
Qualitative No.2 Medium (5) 0.26 125 Fast (80)
Qualitative No.231 Medium (5) 0.18 95 Medium (130)
Quantitative No.3 Medium (5) 0.23 113 Fast (130)
Quantitative No.5A Course (7) 0.22 97 Fast (60)
Quantitative No.5B Medium (4) 0.21 108 Medium (195)
Quantitative No.5C Fine (1) 0.22 118 Slow (570)
Quantitative No.6 Medium (3) 0.20 103 Slow (300)
*Flow time is the time in seconds required to filter 100mL of distilled water at 20℃ under pressure supplied by a 10 cm water column through a 10 cm2
section of filter.

Ordering information: Available in disks of standard diameters (cm): 4.25, 5.5, 7.0, 9.0, 11.0, 12.5,
15.0, 18.5, 24.0 Catalog #’s are specified by grade followed by diameter,
Example: NO112.5CM, NO5B9.0CM Other grades and diameters are available.

G lass Fiber Filters are a dense matrix of 100% borosilicate microfibers.


These filters are chemically resistant and biologically inert. Advantec
Glass fiber depth filters have superior loading capacity and high flow rates.
Grades with binder offer increased wet strength and minimal fiber release.
Binder-free grades can withstand temperatures up to 550°C.

Grade Particle Weight, Thickness, Flow Time* Binder


Retention, µm g/m2 mm sec
GC50 0.5 48 0.19 28 None
GF75 0.3 75 0.35 84 None
GD120 0.5 123 0.51 14 None
GC90 0.9 100 0.30 20 Organic
GS25 0.6 70 0.22 15 Organic
DP70 0.6 170 0.52 20 Organic
*Flow time is the time in seconds required to filter 1000 mL of distilled water at 20℃ under differential pressure of 5.7 psi through a 9.6 cm2 section of filter.

Ordering information: Available in disks of standard diameters (mm): 21, 24, 25, 26, 37, 45, 47, 55,
70, 90, 110, 125, 142, 150 Catalog #’s are specified by grade followed by diameter,
Example: GF75142MM, DP7047MM Other grades and diameters are available.
www.advantecmfs.com
S yringe Filter Units offer a covenient and compact solution for fast
filtration and sample preparation prior to instumental analysis.
Advantec DISMIC syringe filters are designed to maximize sample
recovery. Our pigment-free polypropylene housing along with our
membrane selection ensure low extractables and broad chemical
compatibility for use with a range of samples and solvents.

DISMIC-PTFE for IC were designed specifically for sample prep for Ion
Chromatography and HPLC analysis. Advantec combines a hydrophilic
PTFE membrane with a high purity housing to provide a universal filter
unit with the lowest extractibles on the market.

DISMIC-PVDF offers low protein binding and extractables. Provides fast flow rate and good
resistance to mild aqueous organic solutions.

DISMIC-Nylon is compatible with aqueous and alcoholic solutions as well as most HPLC
solvents. Offers negligible organic extractibles.

Membrane Hydrophilic PTFE PVDF Nylon


Pore size (µm) 0.20 0.45 0.22 0.45 0.20 0.45
Diameter (mm) 13 17 25
2
Filtration area (cm ) 0.9 1.4 4.0
Sterility Non-Sterile Non-Sterile Non-Sterile
Quantity (Packed) 50 (blister packs) 50 (bulk pack) 100 (bulk pack)
Catalog # 13HP020CN 13HP045CN 17VP022AN 17VP045AN 25NP020AN 25NP045AN
Inlet/outlet are standard Luer connections.
Please see our Syringe Filter brochure to view our full selection of syringe filters

Filter Holders and Accessories


Description Catalog #

Stainless Steel Pressure Holder 142mm, 1.5L capacity, 316ss 302400


w/ Reservoir (PTFE coating available)
Glass Filter Holder 47mm, glass support, 300mL funnel 311400
Glass Filter Holder w/ PTFE Seal 47mm, PTFE support, 300mL funnel 351620
Polysulfone Aseptic Holder 47mm, 300mL funnel, cover 501030
All-Glass Holder 47mm, glass support 40/35 joint, 311420
300mL funnel, 1L flask
Stainless Steel Manifold 3-place, standard cup, 2-way valve 353100
6-place, standard cup, 2-way valve 353300
PVC Manifold 3-place, standard cup, 2-way valve 313400
6-place, standard cup, 2-way valve 313600 6723 Sierra Court, Suite A
Vacuum Pressure Pump 115V 800800 Dublin, CA 94568 USA
220V 800801 Phone (925)479-0625
Fax (925)479-0630
pH Test Paper Range 0-14, roll (9mm x 5.5M) W-R [email protected]
Filterceps Beveled smooth tips 17800000 www.advantecmfs.com