Aeroflex IFR Marconi 2945B Datasheet
Aeroflex IFR Marconi 2945B Datasheet
Test Equipment Solutions Ltd specialise in the second user sale, rental and distribution of
quality test & measurement (T&M) equipment. We stock all major equipment types such as
Spectrum Analyzers, Signal Generators, Oscilloscopes, Power Meters, Network Analyzers
etc from all the major suppliers such as Keysight, Tektronix, Anritsu and Rohde & Schwarz.
We are focused at the professional end of the marketplace, primarily working with customers
for whom high performance, quality and service are key, whilst realising the cost savings that
second user equipment offers. We fully test & refurbish equipment in our in-house, traceable
Lab. Items are supplied with manuals, accessories and typically a full no-quibble 1 year
warranty. Our staff have extensive backgrounds in T&M which enables us to deliver
industry-leading service and support. We endeavour to be customer focused in every way
right down to the detail, such as offering free delivery on sales, presenting flexible technical +
commercial solutions and supplying a loan unit during warranty repair, if available.
As well as the headline benefit of cost saving, second user offers shorter lead times, higher
reliability and multivendor solutions. Rental, of course, is ideal for shorter term needs and
offers fast delivery, flexibility, try-before-you-buy, zero capital expenditure, lower risk and off
balance sheet accounting. Both second user and rental improve the key business measure of
Return On Capital Employed.
We are based in at Oakley, Bedfordshire in the UK from where we supply test equipment
worldwide. Our facility incorporates Sales, Support, Admin, Logistics and our own
in-house Lab.
- No-quibble parts & labour warranty (we provide transport for UK mainland addresses).
- Free loan equipment during warranty repair, if available.
- Full electrical, mechanical and safety refurbishment in our 40GHz in-house Lab.
- Certificate of Conformance (calibration available on request).
- Manuals and accessories required for normal operation.
- Free insured delivery to your UK mainland address (sales).
- Support from our team of seasoned Test & Measurement engineers.
- ISO9001 quality assurance.
Email: [email protected]
Web: www.TestEquipmentHQ.com
Wireless
2945B Communications Service Monitor
Comprehensive Oscilloscope Certain characteristics are shown as typical. These provide additional
information for applying the instrument, but are unwarranted.
Analysis of audio signals, whether from the demodulated signal or the
audio input direct, can be viewed for further inspection. The oscillo- RF SIGNAL GENERATOR
scope can either be combined with the measurement screen in the
Tx, Rx or AF test modes or ‘zoomed’ to a full screen display. FREQUENCY
Different levels of persistence can be selected to allow short or long Frequency Range
term effects to be captured.
400 kHz to 1.05 GHz
Transient Analysis Resolution
The ability to capture transients on the rising or falling edge of a 10 Hz
waveform provides a valuable tool for fault finding radios and radio
Indication
systems. The user has full control of the trigger level and input atten-
uation as well as the timebase and five fixed trigger points, making 10 digit display
this feature simple and flexible to operate. Setting
Keyboard entry, delta increment/decrement function and rotary control
Accuracy
As frequency standard
OUTPUT LEVEL
Output Level Range
Rx Test:
N-Type socket: -141 dBm to -21 dBm
Harmonic Analysis BNC socket: -115 dBm to +5 dBm
An automatic harmonic analysis function is included in the 2945B. (overrange to +7 dBm)
This complements the fast spectrum analyzer and allows a rapid
check that the transmitter is not producing any large harmonics.
20 Hz to 20 kHz Accuracy
Resolution ±1 dB
RF FREQUENCY METER
Frequency Range
HARMONIC AND TRANSIENT ANALYSIS
100 kHz to 1.05 GHz (manual tune)
10 MHz to 1 GHz (auto-tune) HARMONIC MEASUREMENT
Resolution Displays 1st to 5th harmonic of the selected carrier
1 Hz or 10 Hz, up to 1050 MHz, selectable Maximum Harmonic Frequency
0.1 Hz, 1 Hz or 10 Hz up to 999 MHz, selectable
1.05 GHz
Indication
Up to 10 digits
Dynamic Range Accuracy (1)
Frequency Range Less than 2%, at 1 kHz and 30% AM, (CCITT weighted)
1 to 1050 MHz Residual AM
Dynamic Range Less than 1% (300 Hz to 3.4 kHz)
60 dB below spectrum analyzer reference level FREQUENCY MODULATION
Scale (power) Frequency Range
10 dB/div 100 kHz to 1.05 GHz
Scale (time) Modulation Frequency Range
50 µs/division to 5 s/div 10 Hz to 15 kHz
Trigger Level Deviation Range
Adjustable over full dynamic range +ve or -ve trigger selection 0 to 75 kHz
Pre-trigger Peak hold facility
0, 25, 50, 75 or 100% of displayed period Resolution
10 Hz below 2 kHz deviation, 1% above 2 kHz deviation
MODULATION METER
Indication
Sensitivity
3 digits and bar chart
Auto-tuned: 5 mW (N-Type)
Accuracy (1)
0.05 mW (Antenna port)
Manual Tuned: -34 dBm (N-Type) ±5% ±1 digit at 1 kHz modulation frequency
-60 dBm (Antenna port) ±7.5% ±1 digit for modulation frequencies 50 Hz to 10 kHz
Auto or manual control of input attenuator
Demodulation Distortion
Audio & Modulation Filters
Less than 2% at 1 kHz and 5 kHz FM, (CCITT weighted)
Lowpass filters
Residual FM
Four independently configurable Lowpass filters LP1, LP2, LP3, LP4
that can be set to any frequency cut off point from 250 Hz to Less than 30 Hz (300 Hz to 3.4 kHz)
20000 Hz (excluding the band 1001 Hz to 2999 Hz) Demodulation Output Socket
A 50 kHz Lowpass (No filters applied) 200 mV peak to peak ±10% per 1 kHz deviation
750 µs de-emphasis
RF SPECTRUM ANALYZER
Highpass filters
50 Hz Highpass, 300 Hz Highpass Frequency Range
Any combination of LP1, LP2, LP3, LP4 and the Highpass filters Spans
2 digits and bar chart Typically ±2 dB ±1 resolution (10 dB/div) >10 dB above noise floor
Frequency Response The SSB demodulator allows signals to be demodulated either via the
internal loudspeaker or via the accessory socket. Provides demodula-
±0.5 dB at 200 Hz to 5 kHz tion of SSB signals (upper and lower sideband).
±2 dB at 100 Hz to 20 kHz Frequency Range
Level Accuracy 400 kHz to 1 GHz
±2% at 1 kHz ± accuracy of 2945B or 2948B AF Demodulation Range
Output Level 10 Hz to 15 kHz
1 mV to 2.5 V RMS across 600 Ω Distortion
ANALOG SYSTEMS CARD (OPTION 2) Typically less than 3% at 1 kHz (300 to 3.4 kHz)
This option provides automatic testing for cellular, trunked and FM Detection Range
radios and a BASIC Interpreter for customized tests
2 µV to 150 W
HIGH STABILITY INTERNAL FREQUENCY (OCXO) STANDARD (OPTION
3) Features
Frequency Automatic detection of USB or LSB. BFO can be used for tuning of
carrier for AM and FM radios.
10 MHz
OCCUPIED BANDWIDTH MEASUREMENT (OPTION 9)
Temperature Stability
Calculates the bandwidth of a signal displayed on the spectrum analyz-
Better than 0.05 ppm, 5 to 55°C er.
Ageing Rate Frequency Range
Better than 0.1 ppm, per year, after 1 month continuous use 1 MHz to 1 GHz
Warm-up Time Display Resolution
Less than 10 minutes to within 0.2 ppm at 20°C 3 digits
PARALLEL INTERFACE (OPTION 4) Accuracy
Allows direct connection of a parallel printer 20%
Additionally provides four software programmable output lines Bandwidth Measurement Range
Printer Port 3 kHz minimum
Connector Ratio range 90% - 99% selectable in 0.1% steps
25 way female D type NMT CELLULAR SOFTWARE (OPTION 10)
Printers Supported NMT 450 NMT 900
75, 100, 150 dots per inch laser printers, FX 80, FX 100 Epson for- Benelux NMTF
mat Austria Spain
Malaysia Indonesia
Accessory Port Saudi 1 Saudi 2
Thailand Oman
Connector
Tunisia Hungary
9 way female D type Poland Russia
Czech Bulgaria
Outputs Slovenia Turkey
4 independently programmable output lines, each one configurable as USER DEFINED NMT
a logic line or as a relay contact closure. +5 V supply available AMPS CELLULAR SOFTWARE (OPTION 11)
GPIB (OPTION 5) USER DEFINED AMPS
Capability TACS CELLULAR SOFTWARE (OPTION 12)
For printing, remote instrument control or for programming of user E-TACS TACS 2
defined test sequences. C-TACS I C-TACS II
Complies with the following subsets defined J-TACS N-TACS
USER DEFINED TACS
IEEE-488:- SH1, AH1, T6, L4, SR1, RL1, DT0, EI, DC1
MPT 1327 TRUNKING SOFTWARE (OPTION 13)
BAND III JRC
UK WATER HONG KONG mounted on a bench.
AUTONET AMT
MADEIRA NL-TRAXIS IF OUTPUT (OPTION 31)
NZ MPT1327 PH-INDO Allows access to the IF signal from the rear of the instrument (Note:-
USER DEFINED MPT Incorporation of this option replaces the standard demod out capability)
PMRTEST SOFTWARE (OPTION 14) INTERNAL BATTERY (OPTION 32)
USER DEFINED PMR for FM radios Type
EDACSTM RADIO TEST SOFTWARE (OPTION 15) 12 V NiMH
Provides Auto/Manual test capability for EDACSTM radios. Up to 4 user Capacity
defined variants can be created and stored, each with up to 24 spot
channel frequencies. Typically 60 minutes operation
Performs bit error rate tests to check performance of receiver and Weight
transmitter. 1.8 kg
EDACSTM REPEATER TEST SOFTWARE (OPTION 16) Charge Time From Instrument
Provides Auto/Manual test capability for EDACSTM repeaters. Up to four 4 hours
user defined variants can be created and stored, each with up to 24
spot channel frequencies. A data logging facility is also available to Temperature Range
continuously decode and display data messages from the repeater
5-35 C charge
under test.
EDACS is an Ericsson GE registered trademark. 0-50 C discharge
LTR TRUNKING TEST SOFTWARE (OPTION 18)
Notes
Provides Auto/Manual test capability for LTR Trunked radios. (Planned
availability Q3 2006)
(1)
At low modulation levels the residual AM/FM may become significant.
Allows a CCITT filter to be inserted into either the demodulated audio Option 6 Memory Card Drive with real time clock
path or the audio input path.
Option 8 SSB Demodulator
CMESS FILTER (OPTION 24)
Option 9 Occupied Bandwidth Measurement
Allows a CMESS filter to be inserted into either the demodulated audio
path or the audio input path. Note : Option 2 required when ordering any of the following options
TONE REMOTE (OPTION 26) 10 to 18
Provides configuration screens and generation of Tone Remote control Option 10 NMT Cellular
signals.
PLUS 2 DISTORTION NOTCH FILTERS BOARD (OPTION 29) Option 11 AMPS Cellular
The standard instrument is supplied with a 1 kHz notch for Distortion Option 12 TACS Cellular
and Sinad measurements. This option allows the user to carry out
Distortion/Sinad measurements at two additional frequencies. The two Option 13 MPT 1327 trunking
additional notch frequencies can be anywhere in the band 50 Hz to
20 kHz and must be stipulated at the time of ordering. Option 14 PMRTEST
Option 29 Plus 2 Distortion Notch Filters board** 46884/649 Serial port to PC control cable (25 way)
Option 30 Bail Arm and Front Panel Stowage cover 46884/648 RS-232 Printer cable (25 way)
Operating Manual
† Options 4 and 5 cannot be fitted together.
Optional Accessories
†† Options 23 and 24 cannot be fitted together.
44991/145 Microphone with PTT * Option 2, Option 21 and Option 32 :- Any two of these options can be
fitted together, but not all three.
59000/189 Memory Card (128 k)
** Option 29, The standard instrument is supplied with a 1 kHz notch for
Distortion and Sinad measurements. This option allows the user to carry
59000/375 Memory Card (2 M) out Distortion/Sinad measurements at two additional frequencies. The
two additional notch frequencies can be anywhere in the band 50 Hz to
46662/779 Soft carrying case (suitable for all 294x, except early 20 kHz and must be stipulated at the time of ordering.
units being used with external battery ‡ External Battery Packs for previous models are still available using the
following order codes 2945A Battery pack 43113/021 or 2945 Battery
46662/571 Soft carrying/operational case pack 43113/018.