The document outlines the specifications and requirements for the façade work of the L&T SOSF project, detailing various materials and installation methods for stone cladding, structural steel frames, exterior paints, aluminum windows, and glass doors. It includes descriptions of the materials to be used, installation techniques, and measurement methods for payment. Additionally, it specifies the warranty requirements and compliance with architectural drawings and engineering instructions.

Uploaded by

Masood Hasan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
113 views12 pages

BOQ Architecture Noida Facade

The document outlines the specifications and requirements for the façade work of the L&T SOSF project, detailing various materials and installation methods for stone cladding, structural steel frames, exterior paints, aluminum windows, and glass doors. It includes descriptions of the materials to be used, installation techniques, and measurement methods for payment. Additionally, it specifies the warranty requirements and compliance with architectural drawings and engineering instructions.

Uploaded by

Masood Hasan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 12

PROJECT: L&T SOSF

FAÇADE
S. No.
1
1.1

1.2

1.3

2
2.1
2.2

3
3.1

3.2
4
4.1

5
5.1

6
6.4

7
7.1

A
B

8
8.1

13
13.1
PROJECT: L&T SOSF
FAÇADE
DESCRIPTION
STONE FIXING
DRY STONE CLADDING
Providing and fixing dry cladding upto 10 metre heights gang saw cut stone with (machine cut edges) of uniform colour an
1.5mx1.0m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with appro
sealant., including holes/ cutting for switch plates, fixtures etc., with all consumables, manpower, any other resource, with
complete as per drawing, technical specification and instruction of Architect / Engineer-in-charge. Rate is inclusive wastag
protection till handing over etc complete at all floors & levels as directed by EIC.
Rate inclusive of cost of all materials, miscellaneous consumables, labours ,transportation of material to all required locati
means , tools, plant and machinery, hire and fuel charges and all other incidental charges etc., all required as per specifica
directed by EIC. The item rates shall hold good for work at all Levels, lead, lifts, Heights, Depths etc.
Mode of Measurement- Actual area measured in vertical plane/ elevation
Note: Rate is exclusive of framework covered in item no. 3.1

STONE 1 (ST01) - Sand Stone - Thickness - 25-30 mm


STONE 2 (ST02) - Granite - Thickness - 22-25 mm

Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand st
heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting,
The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded
embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nom
300x230x300 mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/
including drilling necessary holes. Approved cramps/ pins etc.
shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as a
Engineerin-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor
charge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only struct
shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall b

@5K/Sqm considered for estimation

Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainles
andwasher (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including m
recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-in-charge.
@4 Clamps /Sqm Considered for estimation

EXTERIOR PAINT
EXTERNAL GRADE ACRYLIC EMULSION PAINT
Providing and applying 100% Acrylic exterior paint of approved colour, shade and make finished with brush / spray / roller
by EIC) in one or more coat of putty and two or more coats of Acrylic paint to get desired finish over external RCC surfaces
using approved materials, prepared, applied and finished as per manufacturer's recommendations , etc.
The surface shall be thoroughly cleaned off all mortar dropping, dirt dust, algae, fungus or moth grease and other foreign m
and washing, pitting in RCC/plaster shall make good surface imperfections such as cracks , tie patti holes etc. should be fille
according to approved methodology & treated with one coat of water proofing compound. Approval of the prepared surfa
before commencement of painting work. Paint shall be applied on cleaned and smooth surface .The surface shall be finis
as directed by the Project In charge at all heights & levels.
The rate shall include cost of non-shrink grout, work at all heights, all locations and all levels and for all members, all shape
double-legged scaffolding with proper working platform, curing, cleaning, protection of window glasses & frames, tracks, l
all consumables, manpower, any other resource, etc. complete as per technical specification and to the complete satisfacti
Contractor shall provide seven years warrantee as per manufacturer's specification.
Mode of Measurement: Measurement shall be application area as per drawing.

TEXTURE PAINT
Providing and applying Two coats or more coats to get desired finish of Heavy-duty 100% Acrylic heavy texture waterproo
antialgal, anticarbonation and elastomeric exterior paint system as per manufacturer's recommendation and specification
pattern to external surface including scaffolding, labour, and material and preparing surface. The surface shall be thoroug
mortar dropping, dirt dust, algae, fungus or moth grease and other foreign material by brushing and washing ,pitting in RC
good surface imperfections such as cracks with synthetic fine texture based on polymer emulsion reinforced with quartz &
wall tie patti holes with non-shrink grout etc. Approval of the prepared surface to be obtained before commencement of
rate shall include work at all heights, all locations and all levels and for all members, all shapes and sizes , steel double legg
proper working platform, curing, cleaning, protection of window glasses & frames, tracks,louvers etc., including all consum
any other resource, etc. complete as per technical specification and to the complete satisfaction of Architect / Engineer-in
shall provide warranty as per manufacturer's specification.
Mode of Measurement:- Measeurement shall be application area as per drawing

ALUMINIUM WINDOWS
ALUMINIUM FRAMED WINDOWS
Providing & Fixing Fixed Window/Door comprising of frame with Shutters as per Drawings with ALUMINIUM Extrusions fro
extruder to withstand the project design wind pressure. Include all necessary accessories, E.P.D.M. Gaskets, siliconized wo
and approved European hardware's as a complete tested window system. All exposed ALUMINIUM extrusions with outer
section shall be SDF powder coating (white/Black/Charcoal Grey or as approved) as per approved shade. Non exposed area
chromatised to 5 microns. The quality of coating shall be guaranteed for a period of 15 years. Price shall include fixing of th
marble / Concrete /Plaster rough ground surface with necessary fixing screws of SS 316 grade with rawl plug. The scope sh
providing & fixing thick toughened glass (Thickness as per window Size). The gap between window frame perimeter and st
not exceed 6mm and it should be sealed with backer rod and exterior grade weather sealant from approved sealant manu
Hardware shall be of approved make samples to be submitted for approval.
NOTE: Item rate in compliance with concept drawings and specifications noted herein including cleaning of the windows.
Mode of measurement shall be structural opening size as mentioned in the item description.

W11- 1000X2900MM
W12-1500X2900MM
W13- 2000X2900MM
W14- 3000X2900MM
Structural Curtain Glazing
Providing and fixing all arrangements for Structural Curtain Glazing. Powder Coated of approved shade and make as per de
& mullions to structure through adequately designed galvanized brackets, providing and fixing toughened, reflective glass
approved make as per specifications with aluminium sections using structural silicon sealant of approved quality (Dow Cor
specifications or approved equivalent), including all aluminium sub frames wherever necessary. The complete drainage sys
incorporated in the design in the unlikely event that water penetrates the pressure seal. The system to include sealing with
streaking weather sealant (Dow Corning )as per specifications or approved equivalent in perimeter channel sealing, and co
designed extruded EPDM gasket etc. to prevent water penetration as per IS code .complete as per detailed drawings and
shop drawings. Price is inclusive of erection and dismantling of required scaffolding required for work.

MAIN ENTRANCE GLASS DOOR


AUTOMATIC SLIDING GLASS DOOR
roviding and fixing Automatic Sliding door operator, Make: ASSA ABLOY SL 500HP 6000 mm, design to meet ANSI/BHSM 1
based on the product category rules :IBU: PCR automatic doors, automatic gates and revolving door sysytem, PCR tested.
the product takes into account the proof of conformity with harmonizes norms: EN 16005:2012/AC:2015: Power operated
safety in use- requirement and test methods, EN 61000-6-2:2005: Electromagnetic compatibility,EN 61000-6-3, EN60335-
160 5, IEC 60335-1, IEC 60335-2-103, UL 325, DIN 18650Environmental product declaration in accordance with ISO 14025
for Durability of 1 Million Cycles, for frameless glass door application, modular design including internal cover. and with 12
toughened glass for 1/ 2 Nos sliding door panel, Operator to be mounted on MS-Box Section/Equalant.Operator Finish sho
Anodised E6/C0, with operator dimensions Maximum (H x D) : 123x150 mm and of length as required to suit the opening
The track profile should be separate from the main profile for enabling reduction in vibration insulation and easy maintain
Microprocessor-controlled control unit, Self-learning. Maximum power consumption of 250W.Power Supply100-240V AC/
Auxilary voltage of 24V DC, min. 1000mA Minimum clear opening width COW 800MM (single) and 1000mm (bi-part) Maxi
width COW 3000mm. Minimum and maximum opening height 3000mm (higher on demand). Door weight single 240kg Do
door 2 x 200kg Opening and closing force Friction related, adjustable from 30 to 190N Height x Depth150mm (H) x 123mm
closing speed single 0.85m/sec (depends on perf. Level). Opening and closing speed, bi-part 0.85m/sec (depends on perf.
time 0 to 60 sec.
Ambient Temperature -20 °C to +50 °C. Humidity max 85%. Class of protection(dust). IP 20 EPD-Declaration available conv
(battery-powered) 24V battery (optional). 3 different performance level (Standard, High & Exceptional). Easy performance
(when the use of building change). Operation "mode selector with service indication diode". Combination of dual mode se
distance between mode selector and door system (500 metre). Interlock system,Synchronisation, Partial close function (a
width ,Prolonging of hold open time, Opening delay (adjustable delay to ensure that the lock "unlock") open/close time-ou
impulse is forgotten the door will close by timeout it selves).Nurse function (adjustable opening width depending on the n
performance (ensure safety even without extra safety devices). Status relay output (configurable output on customer need
curtain, door location.)

Clear Opening Size : 2000X3000mm.-Bi-parting door


M.S. COLUMNS
M.S. COLUMNS- FAÇADE FEATURE
Providing & Fixing MS Hollow Circular Sections with Conical Shape at the Top as per approved Design & Drawing & finished
coateding. DIMENSION: 200MM (DIA) & 4500MM (HT.); Thickness: 5 mm Thk.
M.S. SCREEN FACADE FEATURE
M.S. SCREEN
Providing & Fixing MS Fabricated Screen With Hollow Sections In Outer Frame Of approved thickness & Specifications & F
Matt Finish Powder coating
ALUMINIUM SLIDING DOOR/WINDOW / OPENABLE FOR VENTILATORS
FOR SHOW FLAT
Providing and fixing of powder coated (60 to 80 microns) alluminium profiles of doors, windows, ventilators of an
design with extended built-up tubular and other sections. Complete with all necessary fittings Hinges, Handles, E
specified thickness & type of Glass.
System Supplier- Technal, Schueco or equivalent

SLIDING with Clear Glass


W1- 2350X2400MM
W2- 1625X2400MM
W3- 2750X2400MM
W4- 3050X2400MM
W5- 1000X1650MM
W6- 3050X2300MM
W7- 2250X2400MM
W8- 6400X2300MM
W9- 7600X2400MM
W10- 1000X1300MM

OPENABLE with frosted Glass


V1- 900X1200MM
V2- 900X2100MM

SHAFT OPENINGS
GRC JALI Or As per Group Housing / Sample Flat facade
UniStone GRC Customized Screens with Power Spray Casting Method - Providing and fixing Glass Reinforced Concrete (G.R
approved size, pattern, design, shade and thickness of 50mm on frame and design element in 30mm thick casted with pow
have weight approximately between 3.5 – 4 Kg per Sq. Ft. of M/s UniStone make or equivalent. The above weight and thic
dimensions of screens up to 2133mm in height and 1219mm in width and having at least 50% void space. The screens sho
grade’ White Portland Cement manufactured by ‘JK Cement’ or equivalent, Quartz, Fine Silica Sand, having Alkali Resistant
percentage 4.5-5% with minimum zirconia content 16%,manufactured by ‘N.E.G JAPAN’ or equivalent, Super Plasticizers m
‘BASF’ or equivalent, Polymers manufactured by ‘BASF’ or equivalent and U.V resistant non fading Synthetic inorganic exte
should be used for homogeneous concrete pigmentation manufactured by ‘BAYFERROX (Germany)’ or equivalent. The ma
take place in FRP Molds. The GRC screens flexural strength average L.O.P should be above or equivalent to 6N/mm2 & M.O
or equivalent to 15 N/mm2 Fixing of Screens should be ‘Dry fixing’ i.e. to be done with M.S Galvanized Clamps, fixtures an
Fischer and in accordance to approved shop drawings by Engineer in charge.

OP1- 1000X1800MM
OP2- 1500X1800MM
OP3- 750X1800MM

BALCONY RAILING
SHOE-GLASS RAILING Or As per Group Housing / Sample Flat façade
Providing & fixing in position shoeTM Glass railing system to be designed Top mounted continuous Base profile, of height m
Height, Entire System should be Aluminium PVDF Coated of approved shade. Member Railing Height upto 900mm from up
drawings & Glass Panels of upto 1800mm Width, 13.52 mm Laminated toughened glass with Aluminium caprail PVDF Coa
shade fixed with EPDM gasket. System should be dry mount and 100% silicone free. Anchor Fasteners should be HILTI. Anc
Centre to Centre 250mm/ As per design etc complete.
Vendor to do design calculation for Shoe and glass thickness before execution
UNIT QTY. RATE AMOUNT

SQM. 205

SQM. 160
SQM. 45

Kg 1024

No 819

SQM. 791
SQM. 27

NO.

5
6
1
1
SQM. 244
NO. 1

NO. 8

SQM. 11

NO.
1
1
1
1
1
1
1
1
1
1

4
1

NO.

1
3
1

SQM. 35

You might also like