SIDE CHANNEL BLOWER
SERIES K MODEL 08
Version: IE2 TYPE TD EXECUTION MOR
Rev. 15-05 EN
Technical Characteristics
−− Aluminum alloy construction
−− Smooth operation
−− Maintenance free
Electric Motor
−− Motors with IP 55 protection rating.
−− class F insulation, suitable for operating with
inverter (refer to FPZ)
−− Thermal Protector (PTO) as standard
Options Supply voltage - IE2 only at 50 Hz - Tolerance on the
−− Special voltages (IEC 60038) fixed voltage value ± 10%, in range ± 5%.
−− Surface treatments
−− Increased seal version
Perfomance Table
Δpmax Current Consumption (Y/Δ)
Pn Frequency [mbar] Qmax Leq1 Weight H3 [A] Cosφ Speed
[kW] [Hz] [m3/h] [dB(A)] [kg] [mm] [-] [rpm]
Suction Compression IE22 Range
7.5 50 375 325 518 77 100.5 580 9.06 / 15.7 9.18-9.47 / 15.9-16.4 0.78 2940
9 60 325 290 625 79 100.5 580 8.86 / 15.34 9.87-9.00 / 17.1-15.6 0.83 3530
9.2 50 425 425 518 77 105.5 620 10.3 / 17.8 11.1-10.6 / 19.2-18.3 0.83 2940
11 60 425 390 625 79 112 620 10.3 / 17.9 11.9-10.3 / 20.6-17.9 0.86 3530
11 50 - 550 518 77 112 620 12.53 / 21.7 13.0-12.9 / 22.6-22.3 0.81 2940
13 60 - 490 625 79 112 620 12.2 / 21.2 13.8-12.4 / 23.9-21.4 0.84 3530
15 50 - 625 518 77 129 695 16.46 / 28.51 17.8-16.6 / 30.8-28.8 0.84 2940
17 60 - 625 625 79 129 695 15.7 / 27.2 18.1-15.6 / 31.3-27.1 0.86 3540
1. Noise level measured at a distance of 1 m with ducted intake and delivery, in accordance with Standard ISO 3744.
2. IE2 only at 50 Hz.
3. See figure "dimensions" at following page.
SUCTION COMPRESSION
Tolerance on indicated values ± 10%.
Data subject to change without notice.
Curves referring to air at a temperature of 20 °C and atmospheric pressure of 1013 mbar (abs).
FPZ S.p.A. Via F.lli Cervi 16, 20863 Concorezzo (MB), ITALY Tel. +39 039 69 09 81 - [email protected] - www.fpz.com
SIDE CHANNEL BLOWER
SERIES K MODEL 08
Version: IE2 TYPE TD EXECUTION MOR
Rev. 15-05 EN
Dimensions
For all assembly options refer to FPZ.
Dimensions in mm
NOT Binding
a b c d d1 e f G I I1 I2 m n o p1 p2 q r r1 s t u v w x y z
457 498 269 82 192 480 448 G 3" - 187 77.5 13 300 350 650 392 25 137 25 5 M8 310 581 481 319 260 16
INSTALLATION
•• For proper operation of the machine, it must be provided with a suction FILTER and a vacuum/pressure limiting VALVE.
•• Other accessories are available on request.
•• Permissible ambient and fluid temperature in suction from -15 °C to +40 °C.
•• Read the instruction manual carefully before installing the machine.
FPZ S.p.A. Via F.lli Cervi 16, 20863 Concorezzo (MB), ITALY Tel. +39 039 69 09 81 - [email protected] - www.fpz.com