CA18CLNN
CA18CLNN
I E LD™
Thermoplastic Polyester Housing H
I P LES
Type CA, M18, DC TR
• Featuring TRIPLESHIELD™ sensor protection
• Adjustable sensing distance 3-8 mm or 3-12 mm
• Rated operational voltage: 10-40 VDC
• Output: DC 200 mA, NPN or PNP
• Make and break switching function
• LED indication
• High noise immunity
• Flush and non-flush types
• Plug and cable versions
Type Selection
Housing Rated Mounting Ordering no. Ordering no. Ordering no. Ordering no.
diameter operating Transistor NPN/cable Transistor NPN/plug Transistor PNP/cable Transistor PNP/plug
dist. (Sn) 1) Make & break Make & break Make & break Make & break
switching switching switching switching
Specifications
Rated operating dist. (Sn) Indication for output ON LED, yellow
CA18CLF08 3 to 8 mm Environment
factory set at 8 mm Degree of protection IP 67 (Nema 1, 3, 4, 6, 13)
CA18CLN12 3 to 12 mm
factory set at 12 mm Temperature
Operating temperature -25° to +80°C ( -13° to +176°F)
Sensitivity Adj. 270° turn pot. meter Storage temperature -40° to +85°C (-40° to +185°F)
Effectiv operation dist. (Sr) 0.9 x Sn ≤ Sr ≤ 1.1 x Sn Housing material
Usable operation dist. (Su) 0.8 x Sr ≤ Sn ≤ 1.2 x Sr Body Grey, thermoplastic polyester
Repeat accuracy (R) ≤ 5% Front Grey, polyester
Cable end Polyester
Hysteresis (H) 4 to 20% of sensing distance Nuts Black, reinforced nylon
Rated operational volt. (UB) 10 to 40 VDC Connection
(ripple included) Cable Grey, 2 m, 4 x 0.34 mm2
Ripple ≤ 10% Oil proof PVC
Rated operational current (Ie) Plug (M1) M12 x 1
Continuous ≤ 200 mA Cable for plug (M1) CON.1A-series
No-load supply current (Io) ≤ 10 mA Weight
Voltage drop (Ud) ≤ 2.5 VDC at max. load Cable version 110 g
Plug version 30 g
Protection Reverse polarity,
short-circuit, transients Approvals UL, CSA
CE-marking Yes
Frequency of operating
cycles (f) 30 Hz
4 BK
2 WH
3 BU PNP
1) 1 BN
2 WH
4 BK
M12 x 1
3 BU NPN
1) Note: Only CA18CLN
Adjustment Guide
The environments in which modate mechanically demand- CA18CL...
capacitive sensors are install- ing areas, temperature stability
ed can often be unstable re- to ensure minimum need for
garding temperature, humidity, adjusting sensitivity if tempe-
object distance and industrial rature varies and high immuni-
(noise) interference. Because ty to electromagnetic interfe- Max.
of this, Carlo Gavazzi offers as rence (EMI).
standard features in all TRIP-
LESHIELD™ capacitive sen- Note: Min.
sors a user-friendly sensitivity Sensors are factory set (de- Sensitivity
adjustment instead of having fault) to maximum rated sens-
a fixed sensing range, extend- ing range.
ed sensing range to accom-
Installation Hints
Capacitive sensors have the • Chemical Industry • Packaging Industry tive sensor is referenced to a
unique ability to detect almost Cleansers, fertilisers, liquid Package inspection for le- grounded metal plate (ST37).
all materials, either in liquid or soaps, corrosives and pe- vel or contents, dry goods, For additional information re-
solid form. Capacitive sen- trochemicals. fruits and vegetables, dairy garding dielectric ratings of
sors can detect metallic as products. materials please refer to
well as non-metallic objects, • Wood Industry Technical Information.
however, their traditional use Saw dust, paper products, Materials are detected due to
is for non-metallic materials door and window frames. their dielectric constant. The
such as: bigger the size of an object,
• Ceramic & Glass the higher the density of ma-
• Plastic Industry Industry terial, the better or easier it is
Resins, regrinds or moulded Raw material, clay or finish- to detect the object. Nominal
products. ed products, bottles. sensing distance for a capaci-