0% found this document useful (0 votes)
10 views2 pages

Cat 6a U FTP LSZH Cable

The Cat 6A U/FTP LSZH Cable is designed for high-performance data transmission speeds of up to 10GB per second, supporting frequency ranges up to 500MHz and compliant with various industry standards. It features a solid copper conductor, low smoke zero halogen sheath, and is suitable for installations where fire safety is a concern. The cable is tested for quality and compliance at an accredited facility and adheres to European regulatory requirements.

Uploaded by

doneiam24
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
10 views2 pages

Cat 6a U FTP LSZH Cable

The Cat 6A U/FTP LSZH Cable is designed for high-performance data transmission speeds of up to 10GB per second, supporting frequency ranges up to 500MHz and compliant with various industry standards. It features a solid copper conductor, low smoke zero halogen sheath, and is suitable for installations where fire safety is a concern. The cable is tested for quality and compliance at an accredited facility and adheres to European regulatory requirements.

Uploaded by

doneiam24
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Click here for more information:

elandcables.com | Cat 6A U/FTP LSZH Cable

Cat 6A U/FTP LSZH Cable

Eland Product Group: A8N

APPLICATION STANDARDS
A very high performance data cable designed for transmission TiA/EIA 568-B.10, IEC 61158-5
speeds of up to 10GB per second. These cables allow the use Flame Retardant according to BS EN/IEC 60332-1-2
of protocols supported by class EA for the implementation of
10G Base-T. Cat 6A cables support frequency ranges up to
500MHz compatible with PoE & PoE+. For installations where
fire, smoke emissions and toxic fumes create a potential risk to
life and equipment. THE CABLE LAB®
AN ISO/IEC 17025 AND IECEE CBTL ACCREDITED FACILITY
Our world-class testing facility assures the quality and compliance of this cable
CHARACTERISTICS through a continuous and rigorous testing regime.
Temperature Rating
Fixed: -20°C to +60°C

Minimum Bending Radius


Fixed: 4 x overall diameter
Flexed: 8 x overall diameter SUSTAINABILITY COMMITMENT
We are on a journey to Net Zero.
We've committed to near-term emissions reductions and a net-zero target with the
CONSTRUCTION Science Based Targets initiative and we're a signatory to the United Nations Global
Compact Sustainable Development Goals.
Conductor
Learn more about embodied carbon and our carbon emissions reduction actions,
Class 1 solid copper conductor our comprehensive recycling services, and wider ESG activities for sustainable
operations at: www.elandcables.com/company/about-us/esg-sustainability
Insulation
HDPE (High Density Polyethylene)

Screen
Al/PET (Aluminium/Polyester tape)

Drain Wire
Tinned copper wire of 26AWG REGULATORY COMPLIANCE
This cable is compliant with European Regulation EN 50575, the Construction
Sheath
Products Regulation.
LSZH (Low Smoke Zero Halogen)

Core Identification
Pair 1: Blue White/Blue
Pair 2: Orange White/Orange
Pair 3: Green White/Green This cable meets the requirements of the Low Voltage Directive 2014/35/EU,
the RoHS Directive 2015/65/EU and Reach Directive EC 1907/2006. RoHS
Pair 4: Brown White/Brown
compliance has been tested and confirmed by The Cable Lab®.

Sheath Colour
Blue

UK T 020 7241 8787 | F 020 7241 8700 | [email protected] | www.elandcables.com


International T +44 20 7241 8740 | F +44 20 7241 8700 | [email protected] technicalspecification | 1 of 2
Click here for more information:
elandcables.com | Cat 6A U/FTP LSZH Cable

DIMENSIONS
ELAND PART NO. NO. OF AWG NOMINAL DIAMETER OVER INSULATION NOMINAL OVERALL DIAMETER NOMINAL WEIGHT
PAIRS mm mm kg/km

A8NFORCE6ALS 4 23 1.33 7.3 48

PERFORMANCE CHARACTERISTICS
FREQUENCY ATTENUATION NEXT PS-NEXT RL ELFEXT PS-ELFEXT PHASE DELAY
MHz dB/100m dB dB dB dB dB/100m ns

1 2.1 74.3 72.3 20 68 65 570


4 3.8 65.3 63.3 23 56 53 552
8 5.3 60.8 58.8 24.5 49.9 46.9 546.7
10 5.9 59.3 57.3 25 48 45 545.4
16 7.5 56.2 54.2 25 43.9 40.9 543
20 8.4 54.8 52.8 25 42 39 542.1
25 9.4 53.3 51.3 24.3 40 37 541.2
31.25 10.5 51.9 49.9 23.6 38.1 35.1 540.4
62.5 15 47.4 45.4 21.5 32.1 29.1 538.6
100 19.1 44.3 42.3 20.1 28 25 537.6
200 27.6 39.8 37.8 18 22 19 536.5
250 31.1 38.3 36.3 17.3 20 17 536.3
300 34.3 37.1 35.1 16.8 18.5 15.5 536.1
500 45.3 33.8 31.8 15.2 14 11 535.6

ELECTRICAL CHARACTERISTICS
DELAY VELOCITY MAXIMUM UNBALANCED- MAXIMUM MAXIMUM DC CONDUCTOR
SHEW OF PROPAGATION TO-GROUND CAPACITANCE DC RESISTANCE RESISTANCE UNBALANCE
ns/100m % pf/100m ohms/100m %

≤ 45 68 330 9.38 2

The information contained within this datasheet is for guidance only and is subject to change without notice or liability. All the information is provided in good faith and is
believed to be correct at the time of publication. When selecting cable accessories, please note that actual cable dimensions may vary due to manufacturing tolerances.

UK T 020 7241 8787 | F 020 7241 8700 | [email protected] | www.elandcables.com


2 of 2 | technicalspecification International T +44 20 7241 8740 | F +44 20 7241 8700 | [email protected]

You might also like