0% found this document useful (0 votes)
32 views24 pages

Arteche CT Time-Lag-Auxiliary-Relay en

The document provides detailed information about ARTECHE's time-lag auxiliary relays, including their general and functional characteristics, technical standards, and applications in various industries such as electrical utilities, railways, and heavy industry. It highlights the relays' multifunctionality, timing accuracy, and compliance with international standards, ensuring reliability in harsh environments. Additionally, the document outlines model specifications, selectable functions, and installation features for ease of use.

Uploaded by

omo89
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
32 views24 pages

Arteche CT Time-Lag-Auxiliary-Relay en

The document provides detailed information about ARTECHE's time-lag auxiliary relays, including their general and functional characteristics, technical standards, and applications in various industries such as electrical utilities, railways, and heavy industry. It highlights the relays' multifunctionality, timing accuracy, and compliance with international standards, ensuring reliability in harsh environments. Additionally, the document outlines model specifications, selectable functions, and installation features for ease of use.

Uploaded by

omo89
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 24

TIME-LAG

AUXILIARY RELAY
This document may be subject to changes. Contact
ARTECHE to confirm the characteristics and availability
of the products described here.

Moving together
INDEX

4. ›› Answers for any application

5. ›› General characteristics

6. ›› Technical standards

7. ›› Functional characteristics

9. ›› Selectable functions

10. ›› Range of products

13. ›› Breaking capacity

18. ›› Pick-up voltage/release voltage-temperature charts

20. ›› Model selection

22. ›› Dimensions and panel mounting cut-off

Auxiliary Relays | Time-lag Relays 3


ANSWERS FOR ANY
APPLICATION
ARTECHE relays are designed to guarantee the best features and
complete security even in the harshest environment. Only thus it
is possible to have more than 3,000,000 working relays all over
the world.

The action of the output contacts of the time-lag relays is directed


by a timing. This timing can be pick-up timing, drop-out timing or
cyclic timing ... very accurate timing ranges from a few milisecond
till several hours, all of them available in the same relay.

The time-lag relay needs auxiliary supply, in order to operate.


Both the auxiliary supply and the command signal can be
independent. In the event that the command signal and the
auxiliary supply share the same power supply, you must choose
the option “Dependent command signal”. If both signals come
from different power supplies you must choose “Independent
command signal” ( please see pg. 20, in order to choose the
corresponding number from the model selection table).

ELECTRICAL UTILITIES
›› Direct operation upon MV / HV (circuit breaker, sectionalizer).
›› Timings where high accuracy time measure is needed.
›› Specific relays for nuclear power plants.
›› Contact multiplication in power plants and HV / MV substation
controls.

RAILWAYS
›› Traction Substation and Traction system.
›› Door opening and closing control in trains.
›› Lighting system actuation.

HEAVY INDUSTRY (PETROCHEMICAL,


CONCRETE, IRON INDUSTRY,...)
›› Critical process surveillance.
›› Alarms for signalization and telecontrol.

ADVANTAGES
›› Multifunction time lag relays with multi time setting ranges.
›› Relays designed for working in permanence in the whole voltage range
in high temperature environments.
›› Self cleaning contacts.
›› Adapted to vibration and seismic conditions (EN61373 Standard).
›› Security contacts and voltage range +25% - 30% of nominal voltage, for
high security applications.
›› Easy installation (plug in relays, sockets for DIN rail).
›› No maintenance.
›› Possibility of working in 100% relative humidity ambiences.

4 Auxiliary Relays | Time-lag Relays


GENERAL
CHARACTERISTICS
The main features of ARTECHE’s auxiliary relays are the
followings:

›› Security contacts (EN 50205 Standard).


›› Capable to withstand vibrations and seismic
conditions (EN 61373; IEEE 344; IEEE 323;
IEEE C37.98 Standards).
›› Capable to operate under low duty loads,
activate digital inputs, and operate without
any load.
›› Wide range of auxiliary voltage levels (Vdc
and Vac).
›› Sturdy design.
›› Self-cleaning contacts.
›› Designed to allow continuous operation even
in high temperature ambient, within the whole
voltage range.
›› High level of electrical insulation between
input and output circuits.
›› An internal diode is included to avoid
damaging the relay when connecting with
inverse polarity.
›› In compliance with the most demanding test
standards: IEC, EN, IEEE and bearing the CE
mark.
›› High protection degree (IP40), with
transparent cover, making them suitable for
use in salty and tropical atmospheres.
›› Capable to work under ambients with relative
humidity around 100%.
›› Simplicity of installation (plug-in relays in a
wide range of sockets with different installation
configurations).
›› No need of maintenance after installation.

In addition, the different number of alternatives that are offered when


the equipment is selected, both technically (increase of the breaking
capacity by serial contacts) and in the assembly method (front, rear or
flush mounted sockets, with screws or fastons), ...

Auxiliary Relays | Time-lag Relays 5


TECHNICAL STANDARDS
RAILWAY APPLICABLE STANDARDS

›› EN 60077 Series. Rolling stock equipment.


- Part 1: General conditions in service and general terms.
- Part 2: Electrotechnical components.
›› EN 50155 (IEC 60571 equivalent). Railway applications - Rolling
stock equipment.
›› IEC 61373. Railway applications - Shock and vibration tests.
›› NF F 16-101 y NF F 16-102. Rolling stock fire behaviour.
›› RIA 12. Protection from transient and surges.
›› EN 50121-3-2:2006. Electromagnetic compatibility.
›› EN 50205. Relays with forcibly mechanically guided contacts.
WELD NO TRANSFER
›› NF F 70-031. Contact weld resistance tests. NO WELD CONTACTS

GENERAL STANDARDS

In addition to the specific applicable standards, ARTECHE auxiliary


relays are designed based on the fulfilment of the following standards:

›› IEC 61810: Electromechanical all-or-nothing relays.


›› IEC 60255: Electrical relays. Measuring relays and protection
equipment.
›› IEC 61812: Specified time relays for industrial use.
›› IEC 60947: Low-voltage switchgear and controlgear.
›› IEC 61000: Electromagnetic compatibility.

E322124

UL Recognized Component Marks for USA and


Canada: The combined UL signs for the USA and
Canada are recognized by the authorities of both
countries. All auxiliary relays identified with this mark
meet the requirements of both countries.

6 Auxiliary Relays | Time-lag Relays


FUNCTIONAL CHARACTERISTICS

ARTECHE time-lag relays allow 16 timing ranges (from 30 ms to 99h)


and 10 different functions (F0, F7, F9: pick-up timing - F1: pickup timing
acceleration - F2, F3, F8: drop-out timing - F6: flashing timing - F4, F5:
special timing). All of it being easily adjustable from the front of the
relay. According to the most demanding test standards: IEC, EN, IEEE,
and bearing the CE mark.

The great power of the output contacts makes possible direct


action on HV and MV switchgear, because their making/breaking
capacities, continuous through-current and overvoltage capacity
guarantee perfect insulation. Absolutely reliable for use in salty,
tropical atmospheres, and in general in those atmospheres which need
protection with transparent cover.

Timing selections
Time range selector

Function selector

Activation indicator
light

Timing indicator
light

Auxiliary Relays | Time-lag Relays 7


TIMING

To choose the desired timing, the relays have 3 selectors available on


the front part: All the selectors are of discrete step not continuous, and
for this reason the arrow cannot stay in an intermediate position.

The 16 position selector with the indication “Range”, on top right part,
allows to choose between the different 16 time ranges available. Each
of the ranges is determined by a low limit and a top limit, as well as, by
a step, as it is shown in the following table. This same table is printed
on the left side of the relay.

Range Low Limit Top Limit Step


0 30 ms 990 ms 10 ms
1 30 ms 2,97 s 30 ms
2 0,1 s 9,9 s 100 ms
3 0,2 s 19,8 s 200 ms
4 0,5 s 49,5 s 0,5 s
5 1s 99 s 1s
6 3s 297 s 3s
7 5s 495 s 5s
8 10 s 990 s 10 s
9 0,5 min 49,5 min 0,5 min
A 1 min 99 min 1 min

B 3 min 297 min 3 min


C 5 min 495 min 5 min
D 10 min 990 min 10 min
E 0,5 h 49,5 h 0,5 h
F 1h 99 h 1h

›› NOTE 1: If the tens selector is placed on the 0 and the unit one on
the 0 or on the 1, the relay temporizes the step of the selected range.

›› NOTE 2: As the relay cannot temporize less than 30 miliseconds, if


by the selectors it is chosen an option that would suppose a timing
lower than this value, the relay will temporize 30ms. (for example, if
it is selected the range 0, tens 0, and units 1 or 2, according to what
was mentioned on the preceding page, the timing would be 10 ms
or 20 ms respectively, but the relay will temporize 30 ms as it is the
minimum timing limit). On the rest of the positions the timing will be
the selected value.

›› NOTE 3: If all the selectors are placed on 0 (Tens 0, Units 0, Range


0 and Function 0), the timing will be disabled and the relay will
operate in the minimum time possible (electronical and mechanical
initialization delay). This time is a bit lower than 20ms. In a relay with
an instantaneous coil, both coils the instantaneous and the time-lag
will operate at the same time.

›› NOTE 4: The accuracy of the timing will be ±5ms or ±1%, the one
which is higher.

8 Auxiliary Relays | Time-lag Relays


SELECTABLE FUNCTIONS
Below the 3 timing selector in TDF and TDJ models, there is a forth 10 position selector, which
allows to choose the different functions that the relay can execute. The way to make the selection
is the same as ones explained before, by the point of the arrow.

The time diagrams for each of the functions available are printed on the right side of the relay.

For further information about TDJZ specific functions, please see the chart with its technical
features.

Time diagram
F0 F1
F9

F2 F3

F4 F5

F6 F7

F8

These time-diagrams are for TDF-22 relay with


dependent command signal.
For TDF-4, the time-diagram of contacts 3-7 and 4-8
would be the same than for the contacts 5-9 and 6-10.

›› Function 0: Pick up timing


›› Function 1: Pick up timing with acceleration by external control
›› Function 2: Drop out timing, the instantaneous part of the TDF-22 follow the auxiliary supply
›› Function 3: Drop out timing, the instantaneous part of the TDF-22 follow the external control
›› Function 4: Timing with continuity control
›› Function 5: Permanent cycle timing
›› Function 6: Flashing timing
›› Function 7: Pick up timing
›› Function 8: Drop out timing
›› Function 9: Pick up timing with reduced reseting time

Auxiliary Relays | Time-lag Relays 9


TECHNICAL FEATURES
PER MODEL

››World-class range of
auxiliary relays for
energy sector, specially
designed for the most
demanding applications

10 Auxiliary Relays | Time-lag Relays


TIME-LAG RELAYS (I)
Model TDF-2 TDF-4 TDF-22

Applications Electrical command timing


Construction characteristics
Timing Contacts no. 2 Changeover 4 Changeover 2 Changeover
Instantaneous contact no. 0 Changeover 0 Changeover 2 Changeover
DEPENDENT INDEPENDENT DEPENDENT INDEPENDENT
DEPENDENT INDEPENDENT
CONTROL CONTROL CONTROL CONTROL
CONTROL CONTROL
B1 B1 A1 B1 B1 A1
A1 A1 B1
+ 1 2 - + 1 2 - + 1 2 - + 1 2 -
+ 2 1 - + 2 1 -
11 11 11 11
3 7 3 7 3 3
13 13 7 7
INST INST
5 5 12 12 12 12
9 9 4 4
8 8 4 4
TEMP TEMP 8 8
Connections 14 14
13
TEMP
13
TEMP
13 13
6 10 6 10 5 5
9 9 5 9 5 9
TEMP TEMP
14 14 14 14
6 10 6 10 6 6
10 10
DEPENDENT CONTROL
S 2-1 Supply Voltage DEPENDENT CONTROL DEPENDENT CONTROL
C A1-1 Control Voltage S 1-2 Supply Voltage S 1-2 Supply Voltage
C B1-2 Control Voltage C B1-2 Control Voltage
INDEPENDENT CONTROL
INDEPENDENT CONTROL INDEPENDENT CONTROL
S 2-1 Supply Voltage
Options (With OP options) C A1-B1 Control Voltage
S 1-2 Supply Voltage
C B1-A1 Control Voltage
S 1-2 Supply Voltage
C B1-A1 Control Voltage

Weight (g) 265


Dimensions (mm) 42,5 x 50,4 x 96,6 (F large type)
Coil characteristics

Standard voltages(1) 24, 48, 72, 96, 110, 125, 220, 250 Vdc/Vac (50-60 Hz)
Voltage range +25% -30% UN (except range 250: +10% -20%)
Pick-up / Release voltage See power supply-temperature charts for time-lag relays
Average consumption in permanence (UN) 2,6 W 3,85 W 5,35 W
Operating time
Time range between 0,03 s and 99 h
Pick-up time < 23 ms
Drop-out time < 50 ms
Contacts
Contact type 2 Changeover 4 Changeover
Contact material AgNi
Contact resistance(2) ≤ 30 mΩ (standard range) / ≤ 15 mΩ (FF range)
Distance between contacts 1,2 mm
Permanent current 10 A
Instantaneous current 30 A during 1 s / 80 A during 200 ms / 200 A during 10 ms
Max. making capacity 40 A, 0,5 s, 110 Vdc / 30A, 1 s, 36 Vdc, 30.000 operations (1 op/ 15 s)
Breaking capacity See breaking capacity curves
Max. breaking capacity See value for 50,000 operations
Umax opened contact 250 Vdc / 400 Vac
General data
Mechanical endurance 107 operations
Dielectric strength 2,2 kV (between independent circuits) / 1,5 kV (between open contacts)
Impulse voltage 5 kV (between independent circuits) / 2,5 kV (between open contacts)
Insulation resistance >1000 GΩ
Operating temperature Up to 125Vdc -40ºC +70ºC / 220Vdc – 250Vdc -40ºC +55ºC
Storage temperature -40ºC +85ºC
Max. operating humidity 93% / +40ºC
Operating altitude(3) <2000 m

(1)
Other voltage upon request (3)
Ask for higher altitudes
(2)
Guarantee data for relays just manufactured

Auxiliary Relays | Time-lag Relays 11


TIME-LAG RELAYS (II)
Model TDJ-8 TDJ-44

Applications Electrical Command Timing

Construction characteristics
Timing Contacts no. 8 Changeover 4 Changeover
Instantaneous contact no. 0 Changeover 4 Changeover
DEPENDENT CONTROL INDEPENDENT CONTROL DEPENDENT CONTROL INDEPENDENT CONTROL
b b c b b c

+ d a - + d a - + d a - + d a -

10 10 10 10
1 11 1 11 1 11 1 11
20 20 20 20
Connections 2 21 2 21 2 21 2 21
INST INST
30 30 30 30
3 31 3 31 3 31 3 31
40 40 40 40
4 41 4 41 4 41 4 41
TEMP TEMP
50 50 50 50
5 51 5 51 5 51 5 51
60 60 60 60
6 61 6 61 6 61 6 61
TEMP TEMP
70 70 70 70
7 71 7 71 7 71 7 71
80 80 80 80
8 81 8 81 8 81 8 81

Options (With OP options) S d-a Supply Voltage


C b-a Control Voltage
S d-a Supply Voltage
C b-c Control Voltage
S d-a Supply Voltage
C b-a Control Voltage
S d-a Supply Voltage
C b-c Control Voltage

Weight (g) 500


Dimensions (mm) 82,5 x 50,4 x 96,6 (J large type)
Coil characteristics

Standard voltages(1) 24, 48, 72, 96, 110, 125, 220, 250 Vdc/Vac (50-60 Hz)
Voltage range +25% -30% UN (except range 250: +10% -20%)
Pick-up / Release voltage See power supply-temperature charts for time-lag relays

Average consumption in permanence (UN) 6W 7,9 W

Operating time
Time range between 0,03 s y 99 h
Pick-up time <23 ms
Drop-out time <50 ms
Contacts
Contact type 8 Changeover
Contact material AgNi
Contact resistance (2) ≤ 30 mΩ (standard range) / ≤ 15 mΩ (FF range)
Distance between contacts 1,2 mm
Permanent current 10 A
Instantaneous current 30 A during 1s / 80 A during 200 ms / 200 A during 10 ms
Max. making capacity 40 A, 0,5 s, 110 Vdc / 30A, 1 s, 36 Vdc, 30.000 operations (1 op/ 15 s)
Breaking capacity See breaking capacity curves
Max. breaking capacity See value for 50,000 operations
Umax opened contact 250 Vdc / 400 Vac
General data
Mechanical endurance 107 operations
Dielectric strength 2,2 kV (between independent circuits) / 1,5 kV (between open contacts)
Impulse voltage 5 kV (between independent circuits) / 2,5 kV (between open contacts)
Insulation resistance >1000 GΩ
Operating temperature Up to 125Vdc -40ºC +70ºC / 220Vdc – 250Vdc -40ºC +55ºC
Storage temperature -40ºC +85ºC
Max. operating humidity 93% / +40ºC
Operating altitude(2) <2000 m

(1)
Other voltage upon request (3)
Ask for higher altitudes
(2)
Guarantee data for relays just manufactured

12 Auxiliary Relays | Time-lag Relays


TIME-LAG RELAYS (III)
Model TDJZ-8 TDJZ-44

Applications Electrical Command Timing with fix pulse of 3 seconds

Construction characteristics
Timing Contacts no. 8 Changeover 4 Changeover
Instantaneous contact no. 0 Changeover 4 Changeover
DEPENDENT CONTROL INDEPENDENT CONTROL DEPENDENT CONTROL INDEPENDENT CONTROL
b b c b b c

+ d a - + d a - + d a - + d a -

10 10 10 10
1 11 1 11 1 11 1 11
20 20 20 20
Connections 2 21 2 21 2 21 2 21
INST INST
30 30 30 30
3 31 3 31 3 31 3 31
40 40 40 40
4 41 4 41 4 41 4 41
TEMP TEMP
50 50 50 50
5 51 5 51 5 51 5 51
60 60 60 60
6 61 6 61 6 61 6 61
TEMP TEMP
70 70 70 70
7 71 7 71 7 71 7 71
80 80 80 80
8 81 8 81 8 81 8 81

Options (With OP options) S d-a Supply Voltage


C b-a Control Voltage
S d-a Supply Voltage
C b-c Control Voltage
S d-a Supply Voltage
C b-a Control Voltage
S d-a Supply Voltage
C b-c Control Voltage

Weight (g) 500


Dimensions (mm) 82,5 x 50,4 x 96,6 (J large type)
Coil characteristics

Standard voltages(1) 24, 48, 72, 96, 110, 125, 220, 250 Vdc/Vac (50-60 Hz)
Voltage range +25% -30% UN (except range 250: +10% -20%)
Pick-up / Release voltage See power supply-temperature charts for time-lag relays

Average consumption in permanence (UN) 6W 7,9 W

Operating time
Time range between 0,03 s y 99 h
Pick-up time <23 ms
Drop-out time <50 ms
Contacts
Contact type 8 Changeover
Contact material AgNi
Contact resistance (2) ≤ 30 mΩ (standard range) / ≤ 15 mΩ (FF range)
Distance between contacts 1,2 mm
Permanent current 10 A
Instantaneous current 30 A during 1s / 80 A during 200 ms / 200 A during 10 ms
Max. making capacity 40 A, 0,5 s, 110 Vdc / 30A, 1 s, 36 Vdc, 30.000 operations (1 op/ 15 s)
Breaking capacity See breaking capacity curves
Max. breaking capacity See value for 50,000 operations
Umax opened contact 250 Vdc / 400 Vac
General data
Mechanical endurance 107 operations
Dielectric strength 2,2 kV (between independent circuits) / 1,5 kV (between open contacts)
Impulse voltage 5 kV (between independent circuits) / 2,5 kV (between open contacts)
Insulation resistance >1000 GΩ
Operating temperature Up to 125Vdc -40ºC +70ºC / 220Vdc – 250Vdc -40ºC +55ºC
Storage temperature -40ºC +85ºC
Max. operating humidity 93% / +40ºC
Operating altitude(2) <2000 m
Specific functions
1E Pick up timing, fix pulse of 3s
4E, 5E, 6E, and 7E No fuction. Open to new ones
(1)
Other voltage upon request (3)
Ask for higher altitudes
(2)
Guarantee data for relays just manufactured

Auxiliary Relays | Time-lag Relays 13


BREAKING CAPACITY

››With devices operating


worldwide, also heavy
industries like oil &
gas sector trust in our
relays.

14 Auxiliary Relays | Time-lag Relays


BREAKING CAPACITY
The breaking capacity is a critical parameter on the design and the
applications of the relays. Its mechanical life could be considerably
reduced, depending on the value of the load (especially with heavy duty
loads), the number of operations and the environmental conditions in
which the relay is operating.

In any configuration, ARTECHE’s auxiliary relays have a high breaking


capacity values. These limits are showed in the table below, in terms
of power and current values. In all the cases, these relays guarantee a
right performance during 50,000 operations.

Likewise, the values showed in the following charts have been obtained
in standard conditions in the laboratory, and they could be different
in real conditions. In any case, connecting serial contacts or a bigger
distance between contacts makes these values to be considerably
increased.

24 Vdc voltage
Different loads configurations.

Resistive load: Highly inductive load:


›› L/R= 0 ms. ›› L/R= 40 ms.
107 107

106 106
No. operations

No. operations

105 105

104 104
0 5 10 15 20 25 0 2 4 6 8 10 12

Current Current

0 ms 20 ms 40 ms

Vdc P(W) I(A) P(W) I(A) P(W) I(A)

24 450 18,75 300 12,50 210 8,75

Auxiliary Relays | Time-lag Relays 15


110 Vdc voltage
Different loads configurations.
Resistive load: Highly inductive load:
›› L/R= 0 ms. ›› L/R= 40 ms.
10000000
107 10000000
107
No. operations

No. operations
1000000
106 1000000
106

100000
105 100000
105

104
10000 104
10000
0 1 2 3 4 5 6 7 8 9 10 0
0,00 1
1,00 2
2,00 3
3,00 4
4,00 5
5,00 6
6,00 7
7,00
0,00 1,00 2,00 3,00 4,00 5,00 6,00 7,00 8,00 9,00 10,00

Current 1 contact Current


2 contacts

0 ms 20 ms 40 ms

Vdc Contact configuration P(W) I(A) P(W) I(A) P(W) I(A)

1 contact 125 1,14 100 0,91 65 0,59


110
2 contacts
874 7,95 742 6,74 482 4,38

220 Vdc voltage


Different loads configurations.
Resistive load: Highly inductive load:
›› L/R= 0 ms. ›› L/R= 40 ms.
10000000
107 10000000
107

1000000
106 106
1000000
No. operations

No. operations

100000
105 100000
105

10000
104 10000
104
0,00
0,00 0,20
0,20 0,40
0,40 0,60
0,60 0,80
0,80 1,00
1,00 1,20
1,20 1,40
1,40 1,60
1,60 0,00
0,00 0,10
0,10 0,20
0,20 0,30
0,30 0,40
0,40 0,50
0,50 0,60
0,60 0,70
0,70 0,80
0,80
Current Current
1 contact
2 contacts

0 ms 20 ms 40 ms

Vdc Contact configuration P(W) I(A) P(W) I(A) P(W) I(A)

1 contact 125 0,57 104 0,47 60 0,27


220
2 contacts
242 1,10 177 0,81 100 0,45

16 Auxiliary Relays | Time-lag Relays


HOW THE BREAKING
CAPACITY CAN BE INCREASED

ARTECHE’s auxiliary relays are power relays, designed


specially to have a high breaking capacity. Thus, there are
applications where the loads are so high that it is necessary to
even increase the breaking capacity, keeping the reliability of
the contacts of the auxiliary relays.

Thus, ARTECHE relays have the following alternatives and


recommendations:

›› Possibility of external connection of equipment (serial


contacts) getting an important increase of breaking
capacity in these equipment is shown, guaranteeing the
right performance during a high number of operations.

Auxiliary Relays | Time-lag Relays 17


PICK-UP VOLTAGE/RELEASE
VOLTAGE-TEMPERATURE
CHARTS

18 Auxiliary Relays | Time-lag Relays


Variability of operative voltage range against temperature for the time-lag relays.

TIME-LAG RELAYS

Operative range against ambient temperature.

Maximum storage temperature


200

150
Upper limit of the pick-up voltage
U/UN (%)

Pick-up voltage limit


100

Drop-out voltage limit


50
Operative range of the coil voltage

0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110

Temperature (ºC)

Auxiliary Relays | Time-lag Relays 19


MODEL SELECTION
Timers Model FF Aux. Supply Options
Range*

Model Selectión OP 0 0

General purpose range

Relay with 2 timer contacts TDF-2 0** 0 0**


Relay with 4 timer contacts TDF-4 0** 0 0**

Standard model
Relay with 2 instantaneous contacts + 2
TDF-22 0** 0 0**
timer contacts
Relay with 8 timer contacts TDJ-8 0** 0 0**
Relay with 4 instantaneous contacts + 4
TDJ-44 0** 0 0**
timer contacts
Relay with 8 timer contacts TDJZ-8 0** 0 0**
Relay with 4 instantaneous contacts + 4
TDJZ-44 0** 0 0**
timer contacts

FF Range
No -
Rolling stock applications or low duty
Yes FF
loads***

Aux. Supply
Indicate voltage level
(ex.: 24Vdc/Vac)

Options

Dependent 0
Standard
24 Vdc • Vac 1
48 Vdc • Vac 2

Independent 60 Vdc • Vac 3


Command signal voltage 72 Vdc • Vac 4
Different power suppliers
for the comand signal and 96 Vdc • Vac 5
the auxiliary supply 110 Vdc • Vac 6
125 Vdc • Vac 7
220 Vdc • Vac 8

* Indicate just if FF range is required.


** Mandatory option.
*** For more information refer to railway application brochure.

DIMENSIONS OF THE
RELAYS
F Type J Type

F large J large

42,5 82,5
Relay
50,4

50,4

dimensions

96,6 96,6
10,5
10,5

20 Auxiliary Relays | Time-lag Relays


Arteche has more than
100 customer service
technical points, an expert
engineers network close to
you everywhere
RETAINING CLIPS
RETAINING CLIPS OP SOCKET RELATED PLUGGED RELAY
Universal (Bag
Universal (D and F sized sockets RD; RF; RJ; of 20 units)
E0 require 2 units ; J sized sockets TDF; TDJ;
require 4 units) VDF; VDJ Universal (Bag
of 100 units)
E41 DN-DE IP, DN-DE 2C IP RD OP
E50 DN-TR OP, DN-TR 2C OP RD OP
E40 FN-DE IP, FN-DE 2C IP RF OP
E43 FN-DE IP, FN-DE 2C IP TDF OP; VDF OP
E42 FN-TR OP, FN-TR 2C OP RF OP
E44 FN-TR OP, FN-TR 2C OP TDF OP; VDF OP
E31 FN-DE IP, FN-DE 2C IP BF ›› E0 retaining clips
E21 FN-TR OP, FN-TR 2C OP BF
E45 JN-DE IP, JN-DE 2C IP RJ OP
E47 JN-DE IP, JN-DE 2C IP TDJ OP; VDJ OP
E46 JN-TR OP, JN-TR 2C OP RJ OP
E48 JN-TR OP, JN-TR 2C OP TDJ OP; VDJ OP
E29 JN-DE IP, JN-DE 2C IP BJ; UJ
E27 JN-TR OP, JN-TR 2C OP BJ; UJ
OTHER ACCESSORIES
Security pins for RD; RF; RJ; TDF; TDJ; VDF; VDJ relays (bag of 100 units)

›› E** retaining clips

SOCKETS, DIMENSIONS AND


CUT-OUT
Sockets Options
Accessories
Relay Type Screw Double faston Weight (g)
Retaining clips
IP10 Front connection FN-DE IP10 FN-DE2C IP10 110
IP20 Front connection FN-DE IP20 FN-DE2C IP20 110 Function signs on the extraction
F
IP10 Rear connection FN-TR OP FN-TR2C OP 90 ring
IP10 Flush mounting F-EMP OP 300 Security pins
IP10 Front connection JN-DE IP10 JN-DE2C IP10 225
IP20 Front connection JN-DE IP20 JN-DE2C IP20 225
J
IP10 Rear connection JN-TR OP JN-TR2C OP 180
IP10 Flush mounting J-EMP OP 400

Front connection for double


faston IP10 sockets
DN-DE2C IP10
FN-DE2C IP10
JN-DE2C IP10

lateral connection for the


rest of the sockets

›› Front connection socket ›› Rear connection socket ›› Flush mounting socket

22 Auxiliary Relays | Time-lag Relays


Type F Relays Type J Relays

FN-DE IP10 • FN-DE2C IP10 JN-DE IP10 • JN-DE2C IP10

44 84
43 83

64

64
105

105
29 29
48 32,3 88 32,3
Sockets
for DIN
rail
(1) (2) FN-DE IP20 • FN-DE2C IP20 JN-DE IP20 • JN-DE2C IP20
42,7 31 82,7 31
39,8 29 79,8 29
112

112

Fix Drilling Fix Drilling

20 60
= = 3,5 = = 3,5
2 de 2 de

FN-TR IP10 OP • FN-TR2C IP10 OP JN-TR IP10 OP • JN-TR2C IP10 OP

44 43 84
40 6 43
80 6
51,2

41,8
51,2

41,8

Sockets
for rear
connection
40,5 +- 0,2 80,5 +- 0,2
42

42

F-EMP IP10 OP J-EMP IP10 OP


80
80

75 120

Sockets
for flush
mounting
124

124

15

8 12,5
15

8 12,5

106
96 4,5

61
Cut-out
50
66

90 min
57

4,5

Cut-out
125
66
57

90 min

Cut-out
66
57
R2

80 min
106
Cut-out

96
125

90 min
4,5

(1)
DIN rail according to (2)
Minimum distance between sockets will depend on type of relay and
EN50022 DIN46277/3 sockets. Please request sockets user manual for more detailed information.

Auxiliary Relays | Time-lag Relays 23


Updates: ARTECHE_CT_Time-lag-Auxiliary-Relay_EN
Versión: 1.4

www.arteche.com ©Arteche

You might also like