AR-T1-301b-ELEVATION 01 - PART 2
AR-T1-301b-ELEVATION 01 - PART 2
A
GHE
CONSULTANT ENGINEER
T1-K T1-L T1-M T1-N T1-P T1-Q T1-R T1-S T1-T T1-U GULF HOUSE ENGINEERING
Architects & Engineers
2450
ARCHITECT APPROVAL AR-T1-550 ISO 9001, ISO 14001 and ISO 45001
ROOF DECK LEVEL
FFL +44250
+ 43575 +43650 PROJECT
LVL T.O.P
+ 43025
T.O.P
3350
+ 41825 LOUVER SCREEN AS PER ARCHITECT APPROVAL
T.O.P
THERMAL PLASTER (TYPICAL) FINISHED WITH
EXTERNAL WEATHER PROOF FINE TEXTURE PAINT TENTH FLOOR LEVEL
FFL +40900
1575
4400
1575
-100
OWNER
C
4200
W04
1625
W03 W03 W04 W03 W03 W04 W03 W03
3350
0 0 0
2500
EAGLE HILLS
400 1000
400 1000
R01 R01 NINTH FLOOR LEVEL
R02 R02 FFL +37550
400
850
-100 -100
20MM THK. PLASTER GROOVE FINISHED WITH
325
EXTERNAL WEATHER PROOF FINE TEXTURE PAINT
1950
W04 SUB CONSULTANTS
1625
W04 W04 W03 W03 COLOR AS PER ARCHITECT'S APPROVAL
3350
W03 W03 W03 W03
2950
0
2500
0 0 200 200
200 200 200 200
400 1000
400 1000
R01 R01 EIGHTH FLOOR LEVEL
R02 R02
D FFL +34200
400
850
-100 -100
325
1950
AS PER ARCHITECT'S APPROVAL
W04 W04 W03 W03 W04
3350
W03 W03 W03 W03
2950
0 NOTE
2500
2500
200 200 0 200 200 0 200 200
1. THIS DRAWING IS THE PROPERTY OF :
GULF HOUSE ENGINEERING, Architects, Engineers
400 1000
R05 R05 SEVENTH FLOOR LEVEL
R02 R02
FFL +30850 2. REPRODUCING ITS CONTENTS IN ANY FORM EXCEPT FOR THE
20MM THK. PLASTER GROOVE
400
PURPOSE OF WHICH IT IS INTENDED, IS PROHIBITED.
850
850
-100
3. THIS DRAWING IS NOT TO BE SCALED, STATED DIMENSIONS ARE
THERMAL PLASTER (TYPICAL) FINISHED WITH ONLY TO BE CONSIDERED.
1950
W04 EXTERNAL WEATHER PROOF FINE TEXTURE PAINT
W03 W03 W04 W03 W03 W04 W03 W03 4. ALL DIMENSIONS ARE TO BE VERIFIED ON SITE AS PER ACTUAL SITE
3350
COLOR AS PER ARCHITECT'S APPROVAL
0
2500
2500
E 0 0 200 200 CONDITION PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION WORK.
3350
200 200 200 200
5. ANY DISCREPANCIES IN DIMENSIONS & OR INFORMATION SHOULD BE
400 1000
SIXTH FLOOR LEVEL BROUGHT TO THE ATTENTION OF THE CONSULTANT IN WRITING.
R02 R02 R05 R05
REFER TO PART 1
FFL +27500
6. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH STRUCTURAL,
850
850
-100 MEP AND INFRASTRUCTURE DRAWINGS etc.
-100
7. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH SPECIFICATIONS,
40450
30MM THK. DOUBLE INSULATED GLAZING. COLOUR
CONDITIONS OF CONTRACT, etc.
1950
W04 W04 W04 AS PER ARCHITECT'S APPROVAL
W03 W03 W03 W03 W03 W03
3350
0 2950 0 0 8. CONTRACTOR SHOULD CO-ORDINATE ALL WORKS WITH THE
2500
2500
200 200 200 200 200 200 STRUCTURAL, MEP, LANDSCAPE, INFRASTRUCTURE DRAWINGS etc.
9. SURROUNDING LEVELS VARIES AS PER HIGHEST POINT OF FOOTPATH
400 1000
R05 R05 FIFTH FLOOR LEVEL PROVIDED FROM INFRASTRUCTURE.
R02 R02
FFL +24150
400
850
850
-100 ISSUE / REVISION
F 20MM THK. PLASTER GROOVE FINISHED WITH
W04 W04
1950
W04 EXTERNAL WEATHER PROOF FINE TEXTURE PAINT
W03 W03 W03 W03 W03 W03 COLOR AS PER ARCHITECT'S APPROVAL
3350
200 200 0 200 200 0 0
2500
2500
200 200
3350
400 1000
R05 R05 FOURTH FLOOR LEVEL
R02 R02 FFL +20800
850
850
-100
20MM THK. PLASTER GROOVE
1950
W03 W03 W04 W03 W03 W04 W03 W03 W04
3350
2950
0 0 0
2500
2500
200 200 200 200 200 200
00 14/09/2023 ISSUED FOR CONSTRUCTION A.O. A.O.
400 1000
R05 R05 THIRD FLOOR LEVEL
G R02 R02
FFL +17450
REV DATE DESCRIPTION BY CHK'D
400
850
850
-100 -100 -100
30MM THK. DOUBLE INSULATED GLAZING. COLOUR KEY PLAN
AS PER ARCHITECT'S APPROVAL
W04 W04 W03 W03 W04
W03 W03 W03 W03
3350
2950
2950
0
2500
400
850
850
W04
1325
3350
H
1
3350
AR-T1-916
2350
2350
CANOPY AS PER FIRST FLOOR LEVEL
C02 C02 C02 ARCHITECT APPROVAL C01 FFL +10750
900
+10100
LVL
1
900
6400
750
4500
SHEET TITLE
4450
CW01b CW01a CW01b CW02a
3150
MARASSI TERRACES 1
2400
ISSUE FOR
AUG. 2023
AR-T1-301b 00
FILE NAME: