0% found this document useful (0 votes)
246 views2 pages

Ritar HR12-36W-9AH

The HR12-36W is a 12V 36W valve regulated lead acid (VRLA) battery designed for high power discharge applications with a design life of up to 8 years. It features a maximum discharge current of 90A and a weight of approximately 2.45 kg, with a low self-discharge rate and high power output suitable for use in data centers and UPS systems. The battery can be stored for up to 6 months at 25℃ and requires recharging before use.

Uploaded by

Marcos Olivares
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
246 views2 pages

Ritar HR12-36W-9AH

The HR12-36W is a 12V 36W valve regulated lead acid (VRLA) battery designed for high power discharge applications with a design life of up to 8 years. It features a maximum discharge current of 90A and a weight of approximately 2.45 kg, with a low self-discharge rate and high power output suitable for use in data centers and UPS systems. The battery can be stored for up to 6 months at 25℃ and requires recharging before use.

Uploaded by

Marcos Olivares
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

HR12-36W(12V36W)

Specification
Cells Per Unit 6
Voltage Per Unit 12
Capacity 36W@15min-rate to 1.67V per cell @25℃
Weight Approx. 2.45 Kg (Tolerance±5.0%)
Internal Resistance Approx. 22 mΩ
Terminal F2
Max. Discharge Current 90A (5 sec)
HR ( High Rate ) series Valve Regulated Lead
Short Circuit Current 450A
Acid (VRLA) battery is designed for heavy load
Design Life Could Reach 8 years discharge applications with 8 years design
life in float service. By using strong grids, thick
Max. Charging Current 2.7 A
plate and specially designed active material.
C10 8.5AH It is with lower I.R, lower self discharge rate,
Reference Capacity
C20 9.0AH high power, and longer service life. The HR
13.7 V~13.9 V @ 25℃
series battery offers 30% more power output
Standby Use Voltage Temperature Compensation: -3mV/℃/Cell than the standard series. It is suitable for high
power standby used, such as datacenter, UPS,
14.6 V~14.8 V @ 25℃ EPS etc.
Equalization Voltage Temperature Compensation: -4mV/℃/Cell
Discharge: -20℃~60℃
Operating Temperature Range Charge: 0℃~50℃
Storage: -20℃~60℃
Normal Operating Temperature Range 25℃±5℃
ISO 9001 ISO 14001 OHSAS 18001
RITAR Valve Regulated Lead Acid (VRLA) batteries can
be stored for up to 6 months at 25℃ and then recharging
Self Discharge is recommended. Monthly Self-discharge ratio is less
than 3% at 25℃.Please charge batteries before using.

Container Material A.B.S. UL94-HB, UL94-V0 Optional.


MH 28539

Dimensions
151 65 Length 151±1mm (5.94 inches)
6.35
66 Width 65±1mm (2.56 inches)
Height 94±1mm (3.70 inches)
3.4
7.8

Total Height 100±1mm (3.94 inches)


Terminal Value
100
94

6~7 N*m
43

0.8 M5
M6 8~10 N*m
M8 10~12 N*m
F2 Terminal
Unit: mm

Constant Current Discharge Characteristics : A (25℃)


F.V/Time 3MIN 5MIN 8MIN 10MIN 15MIN 20MIN 30MIN 60MIN 90MIN
1.60V 46.94 41.26 32.97 28.26 20.85 16.39 11.68 6.548 4.642
1.67V 42.60 37.44 30.15 26.05 19.50 15.47 11.06 6.241 4.443
1.70V 40.76 35.83 28.95 25.11 18.90 15.06 10.79 6.105 4.360
1.75V 37.75 33.19 26.97 23.53 17.85 14.30 10.34 5.900 4.228
1.80V 34.58 30.40 24.93 21.95 16.95 13.63 9.889 5.679 4.078
1.85V 29.57 25.99 21.24 18.63 14.54 11.84 8.745 5.133 3.730
Constant Power Discharge Characteristics : WPC (25℃)
F.V/Time 3MIN 5MIN 8MIN 10MIN 15MIN 20MIN 30MIN 60MIN 90MIN
1.60V 84.36 74.16 59.46 51.16 38.10 30.17 21.58 12.28 8.787
1.67V 77.51 68.13 55.11 47.84 36.00 28.79 20.78 11.82 8.488
1.70V 74.84 65.79 53.34 46.42 35.25 28.18 20.29 11.63 8.356
1.75V 70.00 61.53 50.25 44.05 33.60 27.11 19.65 11.31 8.140
1.80V 64.98 57.12 47.01 41.53 32.10 26.04 19.00 10.98 7.925
1.85V 56.46 49.63 40.62 35.68 27.90 22.82 16.91 9.993 7.278
(Note) The above characteristics data are average values obtained within three charge/discharge cycle not the minimum values.
HR12-36W(12V36W)
Discharge Characteristics Curve Charge Characteristic Curve For Standby Use
Temperature:25℃(77℉) Temperature:25℃(77℉)
(V/cell)
120 0.14 2.40
2.16 Charge Volume

Charge Voltage (VPC)


Charge Current (CA)
Terminal Voltage (v )

100 0.12 Charge Voltage 2.30

Charge Volume (%)


2.00

80 0.10 2.20
1.84

1.68 0.6C 60 0.06 2.10


After 50% Discharge
5C 3C 2C 1C After 100% Discharge
1.52 40 0.04 2.00

1.36 20 0.02 1.90


Charge Current
0
1 2 3 4 5 10 15 20 25 30 40 50 60 70 80 90 0 0.00 1.80
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28
Discharge Time (min) Charging Time(h)

Storage Characteristics Relationship Between Charging Voltage And Temperature


2.70

2.60

Charge Voltage (v )
Cycle use
2.43~2.47VPC@25℃
Capacity (% )

2.50

2.40

2.30
Standby use
2.28~2.32VPC@25℃
2.20
-20℃ -10℃ 0℃ 10℃ 20℃ 30℃ 40℃ 50℃
Storage Time(months) Temperature (℃)

Temperature Effects On Capacity Relationship of OCV And State of Charge(20℃)


2.20

2.15
Battery Voltage (V)

/Ce l l
36 W
2.10
Capacity (% )

2.05

2.00

1.95

1.90

1.85

1.80
Temperature(℃) 0 10 20 30 40 50 60 70 80 90 100
State Of Capacity (%)

Effect Of Temperature On Long Term Life Life Characteristics Of Standby Use


12.5 Testing conditions: floating charge
Temperature: 25℃( 77℉)
120
Lift Expectancy (y ears)

10.0

100
7.5
80
Capacity(%)

5.0
60

2.5 40

20
0
0 10 20 30 40 50 0
0 1.5 3.0 4.5 6.0 7.5 9.0
Temperature (℃) Life expectancy (years)

(Note) All above information shall be changed without prior notice, Ritar reserves the right to explain and update the latest information.

HENGYANG RITAR POWER CO.,LTD. Add: No.1 Huagong Road, Songmu Industrial Park, Shigu District, Hengyang, Hunan, China 421001
URL: www.ritarpower.com Tel: +86-734-8595528 Fax: +86-734-8595518 E-mail: [email protected] Version 20A-0