Innovative Digital Mammography Upgrade Soution
medlinkimaging.com • 1
Digital
Mammography
Upgrade Solution
Innovative retrofit digital
mammography solution
Vieworks, an Imaging Expert in radiographic imaging,
proudly introduces a Mammography-dedicated retrofit
solution of flat panel detectors for two sizes and viewer
program, VXvue Mammo, as one solution to upgrade the
existing analog and CR system to the digital easily.
VIVIX-M 1824S VIVIX-M 2430S
Small-area Flat Panel Detector for Flat Panel Detector for Mammography
Mammography with High Resolution with High Resolution
Why choose a retrofit solution?
Field-Proven Retrofit Solution Fast and Easy Upgrade
With more than tens of thousands of Via simple connection to the detector and
installations completed globally, Vieworks installation of VXvue Mammo on your
has gained its reputation as an innovator computer, you are all set to go. You can enjoy
of flat panel detector manufacturer in a all the benefits of moving to digital without
general radiography retrofit market. costly facility replacement.
High-Performance
Superior image quality with 75µm pixel pitch provides clearer
clinical images to assist diagnosis effectively. Moreover,
VXvue Mammo maximizes the efficiency of workflow.
Medlink Imaging • Digital Mammography
VIVIX-M 1824S & VIVIX-M 2430S
Easy Upgrade
Same size as a film or a CR cassette (ISO 4090)
Specially designed to use conventional AEC systems
VXvue Mammo — Viewer program specialized for mammography
Thin Chest Wall Distance
Convenient patient positioning
Securing active area easily
TFT (Thin Film Transistor) Indirect Panel
High reliability of X-ray panel
Super durability
High Image Quality
TFT with IGZO
Superior clinical image quality with 75µm pixel pitch
Digital Mammography Acquisition
Viewer for VIVIX-M Series
medlinkimaging.com • 3
VXvue Mammo
Advanced Image Processing by PureImpact™
Mammography dedicated post-processing algorithm
Peripheral and microcalcification enhancement
Sharpness preserving gridline supression
Convenient tools for Mammography diagnosis
Various analysis tools: nipple detection, density estimation, etc.
Image processing parameters for personal preference
Medlink Imaging • Digital Mammography
Convenient presets for various DICOM 3.0 compatible
diagnostic procedures • Modality Worklist (MWL) and Modality
• Easy registration to enhance workflow Performed Procedure Steps (MPPS)
• Automatic image processing and • Storage commitment
labeling of each view position
• User-friendly editing functions Optimized GUI (portrait & landscape)
Advanced image tools Fast and accurate quality control
• Center adjustment via QC tool
• Auto rotation • Five different QC tools of ACR Phantom,
• Annotation: Distance, angle and text Artifact, MTF, Flat Field and Monitor
User-friendly interface
Multi-layout
• Intuitive GUI design
• 1x1, 1x2, 2x2 layout
• User-defined settings (tools, status, etc)
• User-set layout
• Three different UI themes
medlinkimaging.com • 5
Technical Specifications
FXMD-1008S FXMD-2430S
Technology TFT WITH IGZO
Scintillator Csl:TI
Pixel Pitch 75 ㎛
Spatial Resolution 6.7 Ip/㎜
Pixels 3072 X 2304 px 3840 x 3072 px
Grayscale 16 bit
Energy Range 20 kVp to 35 kVp
Image Acquisition Time 3s
Recommended Cycle Time 15 s
Data Interface Gigabit Ethernet
X-ray Generator Interface Auto trigger: AED mode
Dimensions 26.8 cm x 19.5 cm x 1.5 cm 32.8 cm x 25.5 cm x 1.5 cm
Chest Wall Distance 2 mm 1.9 mm
10°C to 35°C
Operating Environment
30% to 85% RH (non-condensing)
Power DC 24 V, 0.75 A DC 24 V, 1 A
* Specifications are subject to change without prior notice.
Medlink Imaging • Digital Mammography
medlinkimaging.com • 7
1 Chapin Road, Unit 3, Pine Brook, New Jersey 07058 • medlinkimaging.com