0% found this document useful (0 votes)
52 views2 pages

RLX - D - G2 - Quick Installationguide - D0010 - v1.7 - EN - 11.2024

This guide provides instructions for the installation of the RLX D G2 floodlight, emphasizing that only qualified electricians should perform the installation. It includes safety warnings, installation requirements, and details about necessary tools and connections. Proper ventilation and cable management are crucial for optimal performance and longevity of the floodlight.

Uploaded by

Vegard Sømliøy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
52 views2 pages

RLX - D - G2 - Quick Installationguide - D0010 - v1.7 - EN - 11.2024

This guide provides instructions for the installation of the RLX D G2 floodlight, emphasizing that only qualified electricians should perform the installation. It includes safety warnings, installation requirements, and details about necessary tools and connections. Proper ventilation and cable management are crucial for optimal performance and longevity of the floodlight.

Uploaded by

Vegard Sømliøy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

This brief guide will take you through the installation of your new RLX D G2 floodlight.

For additional in–depth


product information, operation and maintenance issues, please contact your local Glamox distributor or go
online Marine, Offshore & Wind / www.glamox.com for further information.

 Fully assembled RLX D floodlight  Umbraco 4mm


 Quick installation guide  Electrician’s screwdriver (slot)
 Recyclable cardboard  2x 17mm combination spanners
 24mm combination spanner
 Wire stripper
 Additional cable glands (optional)

The RLX D G2 should be opened or dismantled by Luminell only1. The customer can, however, perform all
power connections described in the Quick Installation Guide or in the RLX User Manual without the latter
requirement being exceeded. If the terminal box has been moulded, do not open it!

To attain the long lifetime, please make sure that the heat sink on the back of the chassis has an adequate
passage to allow air to flow freely – this for the highest possible cooling performance. For outdoor applications
it is important that the external cables and cable glands point downward. If the RLX D is desired recessed,
please make sure to have at least 200 mm of free space around the unit for cooling purposes. The steel bracket
features clearance holes and angle lines offering flexibility when adjusting the light’s horizontal and vertical
direction. Loosen the bolts to pan and adjust the floodlight so that it points correctly. When satisfied, tighten
the bolts with 30 Nm torque. Shall only be installed by a qualified electrician.

CAUTION!
Crush hazard! Be aware of moving
parts when lifting and mounting the
floodlight. Shall only be installed by
a qualified electrician.

1
Or personnel authorized by Luminell.

Doc. No.: D0010 RLX D Quick Installation Guide v1.7 Page 1 of 2


DANGER!
Electric shock risk, 100 – 277 VAC. Ensure that power is disconnected before carrying out any
connections!

 Shall only be installed by a qualified electrician.


 Do not connect the RLX D floodlight on the same power circuit as floodlights using ballast
units (such as high pressure sodium, metal halide or other high intensity discharge lamps).
 Make sure to replace unused cable glans with blind caps M20x1.5. Warranty will be voided
if replaced cable glans / blind caps are not UV and weather resistant, –40°C to 80°C. In
addition, it is the installer’s responsibility to ensure that cable and cable glands are
appropriate for each other.

Unscrew the back plate using an Umbraco 4mm. The leak


proofing seal have a grease (OKS1110) applied to it – if this is wiped
off, please make sure to replace it in order to make the housing leak
proof. Each floodlight is delivered with one cable gland. Make sure to
tighten all four M5 bolts with 5Nm.

Your power cable should hold one wire for ground (GND) and two
power wires – L and N. Dismantle these wires as shown in the figure:
8 mm for each wire, and approx. 35 mm for the cable itself.

The RLX D G2 has two threaded M20x1.5 holes, each with a blind
cap or a cable gland. Use a power cable with appropriate dimensions
so that the cable gland connection is sealed. Make sure to tighten
cable gland and cap nut with *5.5Nm.

*The specified torques where determined under laboratory conditions according to


EN 62444. The torques are therefore guide values, and torque should be observed
under normal climatic conditions for stop ends.

Conductor: Multi core, AWG 16–14 / 1.5-2,5 mm2

To connect the cables to the spring–loaded conductor connection, simply press down a small screwdriver
(preferably a slot screwdriver) as shown in the figure and place the conductor in the spring cage. Repeat
this for each conductor. For the RLX D, follow the circuit outlined below when carrying out the connections.

Optional
100 – 277 VAC
DIM control

Dim Dim Phase Neutral Ground


Max 10 VDC minus plus

Note on coated print circuit board:


In order to withstand extreme conditions even without the glass on, the print circuit boards in the RLX series are coated
with a premium quality tough-gel. During the hardening process, this gel may generate some dew, which could be visible
on the inside of the glass on brand new products. This is not a product failure, and the dew will disappear over time.

Doc. No.: D0010 RLX D Quick Installation Guide v1.7 Page 2 of 2