TASK 21-51-00-040-002-A
Deactivation of the Air Conditioning Pack
FIN: 10HM 11HM
Personnel Required.
Minimum Number of Person 2
Manhours 1.0
Elapsed Time 1.0
WARNING: MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM FROM THE MAIN ENGIN
E, THE APU OR A GROUND SOURCE.
HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
NOTE: The procedure is the same for the two air conditioning packs 10HM (11HM).
1. Reason for the Job
MMEL 21-52-01D
AIR CONDITIONING PACK
MMEL 21-52-01E
AIR CONDITIONING PACK
MMEL 21-52-01F
AIR CONDITIONING PACK
2. Job Set-up Information
A. Consumable Materials
REFERENCE DESIGNATION
14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy -
B. Work Zones and Access Panels
ZONE/ACCESS ZONE DESCRIPTION
190 BELLY FAIR, AIR CONDITIONING & HYD COMPT
191KB, 192KB
C. Referenced Information
© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
REVISION REVISION
CUSTOMIZATION AIRCRAFT TYPES DOCTYPES TITLE
DATE NUMBER
A318 A319 A321 21-51-00-040-002-A - Deactivation of the Air Conditioning
AIC AMM 01-Feb-2025 21
A320 Pack
TAIL NUMBER - MSN - FSN: VT-PPL - 03752 - 111
Print date: 2025-04-10 04:35:30
REFERENCE DESIGNATION
Ref. 24-41-00-861-002-A Energize the Aircraft Electrical Circuits from the External Power
Ref. 24-41-00-861-002-A01 Energize the Aircraft Electrical Circuits from the APU
Ref. 24-41-00-861-002-A02 Energize the Aircraft Electrical Circuits from Engine 1(2)
Ref. 24-41-00-862-002-A De-energize the Aircraft Electrical Circuits Supplied from the External
Power
Ref. 24-41-00-862-002-A01 De-energize the Aircraft Electrical Circuits Supplied from the APU
Ref. 24-41-00-862-002-A02 De-energize the Aircraft Electrical Circuits Supplied from the Engine 1
(2)
Ref. 53-35-13-000-002-A Removal of the Quick-Release Access Panels From the Belly Fairing
Structure
Ref. 53-35-13-400-002-A Installation of the Quick-Release Access Panels on the Belly Fairing S
tructure
Ref. Fig. Pack Flow-Control Unit - Component Location
Ref. Fig. Pack Flow-Control Unit - Component Location
3. Job Set-up
SUBTASK 21-51-00-861-058-A
A. Energize the aircraft electrical circuits Ref. AMM TASK 24-41-00-861-002.
SUBTASK 21-51-00-010-058-A
B. Get Access
(1) Remove the access panel Ref. AMM TASK 53-35-13-000-002:
(a) For PACK 1
- 191KB.
(b) For PACK 2
- 192KB.
SUBTASK 21-51-00-941-057-A
C. Safety Precautions
(1) On the panel 30VU:
(a) Make sure that:
- The APU BLEED pushbutton switch is in the OFF position (the ON legend is off).
- The ENG 1 BLEED and the ENG 2 BLEED pushbutton switches are in the OFF positio
n (the OFF legends are on).
(b) Put a warning notice in position to tell persons not to operate these switches.
(2) On the HP ground connector put a warning notice in position to tell persons not to supply the grou
nd air.
SUBTASK 21-51-00-860-061-A
© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
REVISION REVISION
CUSTOMIZATION AIRCRAFT TYPES DOCTYPES TITLE
DATE NUMBER
A318 A319 A321 21-51-00-040-002-A - Deactivation of the Air Conditioning
AIC AMM 01-Feb-2025 21
A320 Pack
TAIL NUMBER - MSN - FSN: VT-PPL - 03752 - 111
Print date: 2025-04-10 04:35:30
D. ECAM Warning Check before Deactivation
(1) On the Upper ECAM E/WD make sure that the display unit does not show these warnings associat
ed with the operative pack:
- AIR PACK 1 REGUL FAULT or AIR PACK 2 REGUL FAULT
- AIR COND CTL 1-A FAULT or AIR COND CTL 2-A FAULT
- AIR COND CTL 1-B FAULT or AIR COND CTL 2-B FAULT.
4. Procedure
SUBTASK 21-51-00-040-052-A
A. Deactivation of the Air Conditioning Pack
NOTE: This procedure is applicable for the pack flow-control unit with part number 1806A0000-02 or 1
806B0000-01 or 1806B0000-02 or 1806D0000-01.
WARNING: DO NOT TOUCH THE COMPONENT UNTIL IT IS SUFFICIENTLY
COOL TO PREVENT BURNS.
WARNING: USE PROTECTIVE GOGGLES AND GLOVES EACH TIME YOU CUT LOCKWIRE. DISCARD L
OOSE OR USED LOCKWIRE IMMEDIATELY. LOOSE OR USED LOCKWIRE CAN CUT YOU OR
MAKE YOU BLIND.
(1) For PACK 1:
(a) In the cockpit, on the AIR COND section of panel 30VU:
- Make sure that the PACK 1 pushbutton switch is released (the OFF legend comes o
n).
(2) For PACK 2:
(a) In the cockpit, on the AIR COND section of panel 30VU:
- Make sure that the PACK 2 pushbutton switch is released (the OFF legend comes o
n).
(3) On the related pack flow-control unit (1) :
Ref. Fig. Pack Flow-Control Unit - Component Location
(a) Remove and discard the lockwire (2) from the pressure seal cap (3).
(b) Remove the pressure seal cap (3) from the pack flow-control unit (1).
NOTE: This will cause the air to flow out of the pack flow-control unit (1) and close the
butterfly valve.
(c) Make sure that the forked-valve position-indicator lever (5) is in the CLOSED position.
(d) Install the pressure seal cap (3) between the forks of the forked-valve position-indicator lev
er (5) and on the threaded boss (4).
(e) Safety the pressure seal cap (3) with Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - (Materi
al Ref. 14QFB1).
SUBTASK 21-51-00-040-053-A
B. Deactivation of the Air Conditioning Pack
© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
REVISION REVISION
CUSTOMIZATION AIRCRAFT TYPES DOCTYPES TITLE
DATE NUMBER
A318 A319 A321 21-51-00-040-002-A - Deactivation of the Air Conditioning
AIC AMM 01-Feb-2025 21
A320 Pack
TAIL NUMBER - MSN - FSN: VT-PPL - 03752 - 111
Print date: 2025-04-10 04:35:30
NOTE: This procedure is applicable for the pack flow-control unit with part number 1806D0000-02.
WARNING: DO NOT TOUCH THE COMPONENT UNTIL IT IS SUFFICIENTLY
COOL TO PREVENT BURNS.
WARNING: USE PROTECTIVE GOGGLES AND GLOVES EACH TIME YOU CUT LOCKWIRE. DISCARD L
OOSE OR USED LOCKWIRE IMMEDIATELY. LOOSE OR USED LOCKWIRE CAN CUT YOU OR
MAKE YOU BLIND.
(1) For PACK 1:
(a) In the cockpit, on the AIR COND section of panel 30VU:
- Make sure that the PACK 1 pushbutton switch is released (the OFF legend comes o
n).
(2) For PACK 2:
(a) In the cockpit, on the AIR COND section of panel 30VU:
- Make sure that the PACK 2 pushbutton switch is released (the OFF legend comes o
n).
(3) On the related pack flow-control unit (1) :
Ref. Fig. Pack Flow-Control Unit - Component Location
(a) Remove and discard the lockwire (6) from the locking screw (7).
(b) Remove the locking screw (7), the plate of connecting cable (5) and the O-ring (4) from the
pack flow-control unit (1).
NOTE: This will cause the air to flow out of the pack flow-control unit (1) and close the
butterfly valve.
(c) Discard the O-ring (4).
(d) Make sure that the hole of the manual override lever (3) is aligned with the hole of the hall
sensor-plate support (2).
(e) Install these parts in the hole of the manual override lever (3) and the hole of the hall senso
r-plate support (2):
- The locking screw (7)
- The plate of connecting cable (5).
(f) Safety the locking screw (7) with Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - (Material R
ef. 14QFB1).
5. Close-up
SUBTASK 21-51-00-410-058-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panel Ref. AMM TASK 53-35-13-400-002:
(a) For PACK 1:
- 191KB.
© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
REVISION REVISION
CUSTOMIZATION AIRCRAFT TYPES DOCTYPES TITLE
DATE NUMBER
A318 A319 A321 21-51-00-040-002-A - Deactivation of the Air Conditioning
AIC AMM 01-Feb-2025 21
A320 Pack
TAIL NUMBER - MSN - FSN: VT-PPL - 03752 - 111
Print date: 2025-04-10 04:35:30
(b) For PACK 2:
- 192KB.
(3) Remove the WARNING NOTICE(S).
(4) Put an applicable placard in position in the work area (refer to your standard practices and local re
gulations).
(5) Make an entry in the logbook.
SUBTASK 21-51-00-862-057-A
B. De-energize the aircraft electrical circuits Ref. AMM TASK 24-41-00-862-002.
© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
REVISION REVISION
CUSTOMIZATION AIRCRAFT TYPES DOCTYPES TITLE
DATE NUMBER
A318 A319 A321 21-51-00-040-002-A - Deactivation of the Air Conditioning
AIC AMM 01-Feb-2025 21
A320 Pack
TAIL NUMBER - MSN - FSN: VT-PPL - 03752 - 111
Print date: 2025-04-10 04:35:30
191BB
191KB
A
FR34
FR36
Z190
A
192FB
192KB
FR41
A
5
LH SHOWN
RH SYMMETRICAL
4
1 23HB
1 (24HB)
2
3
B 01
NOTE:
01 P/N 1806A0000-02 OR 1806B0000-01 OR 1806B0000-02 OR 1806D0000-01. N_MM_215100_4_BAM0_01_01
Figure 21-51-00-991-00600-00-A (SHEET 1) - Pack Flow-Control Unit - Component Location
** ON A/C FSN 002-050, 105-150, 201-450, 456-500, 551-850, 901-999
© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
REVISION REVISION
CUSTOMIZATION AIRCRAFT TYPES DOCTYPES TITLE
DATE NUMBER
A318 A319 A321 21-51-00-040-002-A - Deactivation of the Air Conditioning
AIC AMM 01-Feb-2025 21
A320 Pack
TAIL NUMBER - MSN - FSN: VT-PPL - 03752 - 111
Print date: 2025-04-10 04:35:30
191BB
191KB
A
FR34
Z190 FR36
A
192FB
192KB
FR41
A
LH SHOWN
RH SYMMETRICAL
3
1 23HB
1 (24HB)
B 01
NOTE:
01 P/N 1806D0000-02. N_MM_215100_4_KB09_01_00
Figure 21-51-00-991-00700-00-A (SHEET 1/2) - Pack Flow-Control Unit - Component Location
** ON A/C FSN 002-050, 105-150, 201-450, 456-500, 551-850, 901-999
© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
REVISION REVISION
CUSTOMIZATION AIRCRAFT TYPES DOCTYPES TITLE
DATE NUMBER
A318 A319 A321 21-51-00-040-002-A - Deactivation of the Air Conditioning
AIC AMM 01-Feb-2025 21
A320 Pack
TAIL NUMBER - MSN - FSN: VT-PPL - 03752 - 111
Print date: 2025-04-10 04:35:30
7 1
4
6
C
N_MM_215100_4_KB09_02_00
Figure 21-51-00-991-00700-00-A (SHEET 2/2) - Pack Flow-Control Unit - Component Location