0% found this document useful (0 votes)
17 views3 pages

It-24-018742 Gondola Rwsi G-06

This document is a certificate issued by Inno-Tech Skills & Equipment Testing, Inc. confirming the thorough examination and test of a suspended working platform (Gondola No. 06) for Roof and Wall Saver Incorporated. The gondola was found fit for operation with specific remarks for safety signage and maintenance requirements. The certificate is valid until September 11, 2025, and outlines the inspection details and responsibilities of operators.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
17 views3 pages

It-24-018742 Gondola Rwsi G-06

This document is a certificate issued by Inno-Tech Skills & Equipment Testing, Inc. confirming the thorough examination and test of a suspended working platform (Gondola No. 06) for Roof and Wall Saver Incorporated. The gondola was found fit for operation with specific remarks for safety signage and maintenance requirements. The certificate is valid until September 11, 2025, and outlines the inspection details and responsibilities of operators.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

INNO – TECH SKILLS & EQUIPMENT TESTING, INC.

43 Ma. Elena Street, Carmel Subd., Bahay Toro, Quezon City, Philippines
Tel. No.: (0632) 8928-6626 Telefax: (0632) 8697-7246
Cell number: 09173270580/09228321058 Email address: [email protected] / [email protected]
DOLE Accreditation No. 1410-22011822-0008 SBMA Accreditation No. REG.2010-123
____________________________________________________

D A T E : September 12, 2024


CERTIFICATE No.: IT-24-018742

CERTIFICATE OF THOROUGH EXAMINATION AND TEST OF


SUSPENDED WORKING PLATFORM
(As required under the Department of Labor & employment order No.13, Series of 1998 on
Guidelines Governing Occupational Safety and Health in the Construction Industry)

Name of owner and address ROOF AND WALL SAVER INCORPORATED


0643 Quirino Avenue, San Dionisio, Paraňaque City
Description of Suspended Test load Safe working Defects noted, alterations or
Working Platform, type & applied load repairs required. If none,
distinguishing mark ( Kgs.) ( Kgs.) enter “None” and state
SWL whether in safe order

GONDOLA No. 06
FIT FOR
Platform: STEEL PLATFORM 470 kgs. 350 kgs. / OPERATION
L= 5.0 m, W= 0.69 m, 2 persons
H= 1.1 m REMARKS:
Brand: SHENXI • Must provide safe
Model: ZLP800 working load signage
Serial No.: 0190185 (350 kgs. / 2 persons).
Hoists S/N: 6173055/6173054 • Install additional heavy
Capacity: 800 Kgs. hammer.
Date Manufactured: 2017 • Install limit stopper.
Cable diameter: 8.3 mm
Power: 1.8 kW each motor, 3 Note:
phase, 220 V, 60 hertz
Synchronized motor driven, • All operators of the
Equipped with two over-running, equipment should have
devices and anti-tilting safety undergone proper training
wires. Top wall anchored. and assessment in
Gondola operation
Installed at 50TH FLOOR, ROOF /maintenance.
DECK, FACING POOL AREA, THE • In-house check &
GENTRY CORPORATE PLAZA, 130 inspection of all
VALERO STREET, MAKATI CITY components of the
gondola is required every
time a unit is operated.
I hereby certify that on September 12, 2024, the Gondola described in this certificate
was tested and thoroughly inspected by me in accordance with the Manufacturer’s
Specification and Standards, and the attached checklist is correct. The Gondola should
be presented for Thorough Examination & Test on or before September 11, 2025, if
not transferred to another location.

DOLE Testing Organization Accreditation no.: 1410-22011822-0008

LENDL MARK H. MANALO


( Signature of Equipment Inspector )
Qualification : Equipment Inspector
Mechanical Engineer- 0088209

Attested by:

DENNET C. LINO CARLITO B. PENA


Professional Mechanical Engineer REE-0015038 & DOLE NO. 1030-111720 - OSHC-061
PRC Registration Number: 5158
PTR No.: 8377012 Date Issued: 1/02/2024
Place issued: Calamba City / TIN No.: 130-670-993-000

Name and address of company by whom the INNO-TECH SKILLS & EQUIPMENT TESTING, INC.
person conducting the test and inspection is 43 Ma. Elena Street, Carmel Subd.
employed. Bahay Toro, Quezon City

The ITSET Inc., has no liability for loss or damages caused by its officers, employees or others who act under assignment from the ITSET Inc. regardless
of whether such person has acted intentionally or negligently and irrespective of whether the loss or damage has affected the company or others who
have requested the ITSET’s assistance or any third party who without any contractual relations with the ITSET Inc. has acted or made arrangements in
reliance on decisions made or information given by or on behalf of the ITSET nor can the individual or individuals who have personally caused the loss
or damage be held liable.
INNO-TECH SKILLS & EQUIPMENT TESTING INC.
______________________________________________

Checklist for Thorough Inspection of Suspended Working Platform


(As per ANSI / ASME B30.9 Standards)

D A T E : September 12, 2024


CERTIFICATE No.: IT-24-018742

Brand/Model: SHENXI ZLP800 Capacity: 800 Kgs.


Serial Nos.: 6173055/6173054 Date Manufactured: 2017
Dimension : L= 5.0 m, W= 0.69 m, H= 1.1 m Counterweight: 1300 Kgs.
(40 pcs.)

Items for Inspection Check Points &


Inspection Deficiencies S US Reject Passed
1. Wire Rope Cables No ten randomly broken wires in √ √
one rope lay, or five wires in one
L R rope strand in one rope lay
No kinking, crushing, unstranding, √ √
WW 8.3 8.3 birdscaging
SW 8.3 8.3 No strand displacement, core √ √
protrusion
No broken or cut strand, corrosion √ √
No crack/s √ √
No nicks √ √
2. Platform No gouges √ √
No crack/s on welding joints √ √
No substitution of parts √ √
w/ wall rollers No bending / deformation √ √
3. Drive Motors Functions properly √ √
4. Over-running & anti- Functions properly √ √
tilting safety devices S/N: (1961084) (1861872)
5. Anchorage Must be of sound material √ √
Good mechanical construction √ √
No serious deformation √ √
6. Lifelines (2 Sets) Check if missing or damaged √ √
TO BE
7. Legible Identification Have legible identification PROVIDED
8. Working Height 108.0 meters
9. Front Beam 1.70 meters & 1.70 meters
(overhang)
10. Distance between 3.60 meters & 4.0 meters
Front & Rear Base
• Monitor the tense of reinforcing wire rope.