It-24-018742 Gondola Rwsi G-06
It-24-018742 Gondola Rwsi G-06
43 Ma. Elena Street, Carmel Subd., Bahay Toro, Quezon City, Philippines
Tel. No.: (0632) 8928-6626 Telefax: (0632) 8697-7246
Cell number: 09173270580/09228321058 Email address: [email protected] / [email protected]
DOLE Accreditation No. 1410-22011822-0008 SBMA Accreditation No. REG.2010-123
____________________________________________________
GONDOLA No. 06
FIT FOR
Platform: STEEL PLATFORM 470 kgs. 350 kgs. / OPERATION
L= 5.0 m, W= 0.69 m, 2 persons
H= 1.1 m REMARKS:
Brand: SHENXI • Must provide safe
Model: ZLP800 working load signage
Serial No.: 0190185 (350 kgs. / 2 persons).
Hoists S/N: 6173055/6173054 • Install additional heavy
Capacity: 800 Kgs. hammer.
Date Manufactured: 2017 • Install limit stopper.
Cable diameter: 8.3 mm
Power: 1.8 kW each motor, 3 Note:
phase, 220 V, 60 hertz
Synchronized motor driven, • All operators of the
Equipped with two over-running, equipment should have
devices and anti-tilting safety undergone proper training
wires. Top wall anchored. and assessment in
Gondola operation
Installed at 50TH FLOOR, ROOF /maintenance.
DECK, FACING POOL AREA, THE • In-house check &
GENTRY CORPORATE PLAZA, 130 inspection of all
VALERO STREET, MAKATI CITY components of the
gondola is required every
time a unit is operated.
I hereby certify that on September 12, 2024, the Gondola described in this certificate
was tested and thoroughly inspected by me in accordance with the Manufacturer’s
Specification and Standards, and the attached checklist is correct. The Gondola should
be presented for Thorough Examination & Test on or before September 11, 2025, if
not transferred to another location.
Attested by:
Name and address of company by whom the INNO-TECH SKILLS & EQUIPMENT TESTING, INC.
person conducting the test and inspection is 43 Ma. Elena Street, Carmel Subd.
employed. Bahay Toro, Quezon City
The ITSET Inc., has no liability for loss or damages caused by its officers, employees or others who act under assignment from the ITSET Inc. regardless
of whether such person has acted intentionally or negligently and irrespective of whether the loss or damage has affected the company or others who
have requested the ITSET’s assistance or any third party who without any contractual relations with the ITSET Inc. has acted or made arrangements in
reliance on decisions made or information given by or on behalf of the ITSET nor can the individual or individuals who have personally caused the loss
or damage be held liable.
INNO-TECH SKILLS & EQUIPMENT TESTING INC.
______________________________________________