AN ISO 9001:2015 COMPANY
Air Filter
PRODUCT
Catalogue
www.mechmaark.in
Filter Standard Chart
Average Efficiency @
Type Filter Class EU Classifications MERV Efficiency %
0.3µ
G1 EU-1 N/A Rod Filters
MERV 1-4
G2 EU-2 N/A 85% down to 20µ
Filters Coarse Dust
G3 EU-3 MERV 5-6 N/A 90% down to 20µ
G4 EU-4 MERV 7-8 N/A 90% down to 10µ
F5 EU-5 MERV 9-10 N/A 95% down to 5µ
F6 EU-6 MERV 11-12 N/A 99.9% down to 5µ
Filters for Fine Dust F7 EU-7 MERV - 13 N/A 99% down to 3µ
F8 EU-8 MERV - 14 N/A 99.9% down to 3µ
F9 EU-9 MERV - 15 N/A 50% down to 0.3µ
Filters For H 10 EU-10 MERV - 16 85% 85% down to 0.3µ
Microparticle H 11 EU-11 MERV - 17 95% 95% down to 0.3µ
s
H 12 EU-12 MERV - 18 99.50% 99.5% down to 0.3µ
HEPA Filters H 13 EU 13 MERV - 19 99.95% 99.97% down to
0.3µ
H14 EU 14 MERV - 20 99.995% 99.99% down to
0.3µ
99.999% down
H 15 EU 15 N/A 99.9995%
to 0.3µ
ULPA Filters H 16 EU 16 N/A 99.99995% N/A
H17 EU 17 N/A 99.999995% N/A
ACTIVATEDCARBON /CHEMICALAIRFILTERS
TOREMOVETOXICGASSESANDODOURS
S.No. Types of Filters Filter media Types of Pollutants Area’s where Filters are Suitable
Activated Carbon Light Hydrocarbon VOC’s
(Non- Impregnated)
Butane, Tar, Separation of odours in the Airport, Office and
Petrol and Administration Building, Hotels, Hospitals,
Filters With Kerosene IAQ Improvement
1. Activated
Vapours from Solvent Filtrations of Inlet air in Microelectronics
carbon (Loose or
Laminated type) Body, Hospital Elimination of Harmful Gaseous
Odours, vapours from circulating Air
Cigarette Smokes
Food, Kitchen and
Animal Room
Impregnated Activated Acidic Trace
Carbon and Other
Acid SOx, Inlet Air Filtrations for controls DataandComputer
Mixture of Chemical
Rooms
Media NOx, NO2
Chemical Inletand Circulating air filters for microelectronics
2. Filters For HCL, H2SO4, H2S, HF,
Inletand Circulating air filters for Museums,
Specific Gas Cl2
Adsorption Hospital, Archives, Libraries
Amines
Refineries, Nuclear Powerstations etc
NH3,
NH4
Formaldeh
yde
Ozone etc
WE FOLLOW ISO16890/EN–779 STANDARDS
FORCOARSE, PRE &FINEFILTER
Relation BetweenASHRAE52.2,EN779and1SO16890
ASHRAE 52.2 EN779 ISOePM ISO ePM2.5 ISOePM ISO Coarse
10
MERV 5 G3 - - - >80%
MERV 7 G4 - - - >90%
MERV 8-9 M5 - - >50% -
MERV 10-12 M6 - 50-60% >60% -
MERV 13 F7 50-65% 65-80% >85% -
MERV 14 F8 65-80% >80% >90% -
MERV 15 F9 >80% >95% >95% -
Particle size
Particle Size
within Practicle size Practicle >
within 1.0µm-
0.3µm-1.0µm, within 3.0µm- 10.0µm,
Typical 3.0µm, Lead
All bacteria, 10.0µm, Mold Pollen, Dust
Control dust, Milled
Cooking oil, Spores, Hair mites, Sanding
Contaminants’ flour, Coal dust,
Most smoke, spray, Cement dust, Spray
Auto emissions,
Copier toner, dust, Snuff, paint dust,
Nebulizer drop,
Most face Powdered milk Textile Fibers
Welding fumes
powder, Most
paint pigments
IAQ
IAQ
concerned
concerned Commercial, Gross filter,
Application commerci
commercial, industrial, domestic and
al &
industrial, paint shop commercial
industrial,
medical,food etc
medical
EN779-2012STANDARD
EN 779-2012 Classifications
Avg. Arrestance Avg. Arrestance Minimum
Group Filter Class FPD (Pa)
(Am) (Em) for 0.4 µm Arrestance
of Synthetic Dust particles % for 0.4µm particles
% %
G1 250 50<Am 65 - -
G2 250 65<Am<80 - -ww
Coarse
G3 250 90<Am - -
G4 250 - - -
M5 450 - 40<EM<60
Medium
M6 450 - 60<EM<80
F7 450 - 80<EM<90 35
Fine F8 450 - 90<EM<95 55
F9 450 - 95<EM 70
MECHMAARK'S PRE FILTERS 10 MICRON
FILTER CLASSES AS PER ISO-16890
FILTER CLASS ePM 1 ePM2.5 ePM 10
ISO COARSE/G-4 < 50%
Filter MOC MERV Filter Eurovent Frame Gasket Testing
Class Rating Class Depth Thickness Standard
G-4 Aluminium MERV- 8 EU-4 25 3 MM BS EN:779
Extrusion/GI MERV- 8 EU-4 50 3 MM BS EN:779
Filter Class: EU-4
Mechmaark Pre Filters are manufactured in accordance with BS EN779 and are
used to remove solid particles of dia >= 10 Micron from the air stream entering the
ventilation system.
Media: 100 % washable Synthetic non woven Synthetic media supported by
Aluminium. Mesh on one side & finishes with HDPE mesh on the other side.
Features:
• Tested according to EN:779.
• Light weight &robust construction.
• Available in wide variety of sizes.
• Low pressure drop.
• 100 % washable.
• Long service life.
Applications:
• For Pre filtration for air conditioning & Air Handling Units.
• General Air Filtration & Pre Filtration for various equipments.
• For maintaining indoor air quality.
TECHNICAL PARAMETERS
Filter Size CFM Efficiency IPD Recommend Max. Temperatu
ed FPD Pressu re
re Resistance
% Pa Pa Pa 0C
610 X610 X 25mm 1000 90% @ 10 Micron 40 150 500 70
610 X305 X 25mm 500 90% @ 10 Micron 40 150 500 70
305 X305 X 25mm 250 90% @ 10 Micron 40 150 500 70
610 X610 X 50mm 2000 90% @ 10 Micron 40 150 500 70
610 X305 X 50mm 1000 90% @ 10 Micron 40 150 500 70
305 X305X 50mm 500 90% @ 10 Micron 40 150 500 70
• Also Available in High Temperature. • Special dimensions can be customized.