CLAS HE EVO
CLAS HE EVO System
USER’S MANUAL
CONDENSING WALL-HUNG GAS BOILER
Dear Customer,
GUARANTEE
Thank you for choosing an ARISTON boiler. The appliance is guaranteed for 5 years from the date of
We guarantee that your boiler is a reliable and technically purchase.
sound product. Aristons only obligation under the guarantee will be to repair
or replace the faulty appliance at Aristons discretion. This will
This manual provides detailed instructions and
be carried out where the fault arises from within defects in the
recommendations for proper installation, use and appliance, caused either by material or workmanship of the
maintenance. manufacturer.
Remember to keep this manual in a safe place for future This guarantee does not protect malfunction or damage arising
reference i.e. by the gas meter. from incorrect installation, commissioning or maintenance
procedures as laid out in the installation and servicing manual,
Your local ARISTON Servicing Centre is at your complete inefficient flue system, poor or incorrect electricicty, wrong gas
disposal for all requirements. supply or pressure, tampering by inexperienced persons and
any other cause not directly due to manufacture.
Ariston Thermo UK Ltd cannot accept responsibility for any
cost arising from repair or maintenance carried out by any third
party.
Service under the guarantee does not affect the expiry date
of the guarantee. The guarantee on parts and appliances
which are exchanged ends when the guarantee on the original
appliance expires.
This guarantee does not affect your statutory rights.
The boiler must be registered with Ariston within 30 days from
date of installation.
Registration is online at www.ariston.co.uk.
2/
USER’S MANUAL
CE labelling
The CE mark guarantees that the appliance conforms to the
following directives:
- 2009/142/CEE
relating to gas appliances
- 2004/108/CEE
relating to electromagnetic compatibility
- 92/42/CEE
relating to energy efficiency
- 2006/95/CEE
relating to electrical safety
- 2009/125/CE
Energy related Products
- 813/2013
Commission regulation (EU)
/3
USER’S MANUAL
4/
USER’S MANUAL
Control panel
2 12
3
11
2 1 24
4 3 23
22
4
12
21
5
I
10
20
6
9
19
7
18
8
17
9
6
16
10
11 15
12 13 14
5
9
6 8
7
Legend :
1. Display
2. Domestic Hot Water adjustment button +/-
(only for Clas HE EVO models)
3. MODE button
(Operation mode selection (summer/winter)
4. Pressure gauge
5. Auto Function and/or Comfort Function
enable/disable button
(Comfort function only for Clas HE EVO models)
6. ESC button - reserved for technical assistance
7. “encoder” programming knob
- reserved for technical assistance
8. OK button - reserved for technical assistance
9. ON/OFF button
10. TIME CLOCK (option for System boilers))
11. RESET button
12. Heating temperature adjustument button +/-
/5
USER’S MANUAL
Winter
Summer
Note.
Note: Connections viewed from behind boiler
Connections viewed from
behind boiler. 3
behind boiler.
3
6/
USER’S MANUAL
A
2 1 24
3 23
22
4
12
21
5
C
I
20
6
19
7
18
8
17
9
6 B
16
10
11 15
12 13 14
4. For operation
Put the selector switch B to the symbol to control the central
heating by the clock. Put the switch B to “I” to select permanent
operation or to “0” to turn the central heating off permanently.
/7
USER’S MANUAL
COMFORT function (CLAS HE EVO models) Auto button - Temperature adjustment activation
The comfort mode has priority over any other heating request. The AUTO function enables boiler operation to be adapted to
There are two settings for the comfort mode (they can be adjusted environmental conditions and to the type of system it is installed on.
in the parameters menu): Comfortable temperature is reached inside the room in the quickest
1. As soon as DHW is drawn, the secondary heat exchanger is kept way possible, without wasting money, energy or efficiency, while
warm for 30 mins. substantially reducing the amount of wear experienced by the
2. As soon as DHW is drawn, the secondary heat exchanger is kept components.
warm permanently.
This function may be enabled by pressing the COMFORT button. Your installer will advise you on the devices connectable to the
boiler and will program it according to the system.
Note
Esc, Ok and Encoder
The Esc, Ok and Encoder are reserved for use by the service
technician.
If one of these buttons/knobs are activated by accident by the end
user ‘SERV’ is displayed
This will deactivate after a few seconds.
All other button are reserved for use by the end user
8/
USER’S MANUAL
Safety shut-off 1 03
This type of error is “volatile”, which 1 04
means that the boiler starts up again 1 05 Insufficient circulation
automatically as soon as the problem
which caused the shut-off is removed. 1 06
The display will flash ”Err” and the 1 07
error code.
1 08 Insufficient water (request filling)
In fact, as soon as the cause of the
shut-off disappears, the boiler starts 3 05 P.C.B error
up again and continues to operate 3 06 P.C.B error
normally.
While the boiler is shut off for safety reasons, it is possible to attempt 3 07 P.C.B error
to restore normal operation by switching the appliance off and on
again using the ON/OFF button on the control panel. The anti-frost function acts on the central heating flow temperature
If the boiler still indicates a safety shut-off, switch it off. Make sure probe, independently from other settings, when the electrical
the external electric switch is in the OFF position, close the gas tap
supply is turned on.
and contact a qualified technician.
If the primary circuit temperature falls below 8°C the pump will run
for 2 minutes.
Safety shut-off due to insufficient water pressure
After the two minutes of circulation (fixed) the boiler will check the
If the water pressure inside the
following:
heating circuit is insufficient, the
a) if the central heating flow temperature is > 8°C, the pump stops;
boiler will perform a safety shut-off.
b) if the central heating flow temperature is between 4 and 8°C, the
(See table).
pump will run for another two minutes;
To re-pressurise the boiler, it will
c) if the central heating flow temperature is < 4°C, the burner will
be necessary to connect the silver
flexible hose supplied to the two fire (heating position) at minimum power until the temperature
isolating points underneath the reaches 33°C, the burner will go off and the pump will continue
boiler, once the hose is connected, to run for two minutes.
open up both of the black quarter The anti-frost device activates only when (with the boiler operating
(see p.5) turn handles, once the pressure reads 1.5 bar on the correctly):
display, close both handles and disconnect the hose . - the system pressure is correct,
If the pressure drops very frequently, there may be a water leak - the boiler is electrically powered,
at some point in the system. If this is the case please contact your - there is a supply of gas.
installer and ask them to check it.
Operation shutdown
This type of error is “non volatile”, which means that it is not removed Change of gas type
automatically. The display will flash Err and the error code. Our boilers are designed to function either with Natural Gas
In this case the boiler does not restart automatically, but it may (methane) or Propane. If you need to change from one gas to the
be reset by pressing the button. If the problem manifests other, one of our Authorised Service Centres must be contacted to
itself again after several attempts to reset the appliance, contact a convert the appliance.
qualified technician.
IMPORTANT Maintenance
Schedule an annual maintenance check-up for the boiler with a
competent person.
Correct maintenance always results in savings in the cost of
running the system.
Failure to arrange an annual service for the appliance will invalidate
the second year and subsequent years of the manufacturers
guarantee.
/9
5 Year Guarantee
Terms & Conditions
WHAT ARISTON REQUIRES
The boiler must be registered with Ariston within 30 days from date of installation. Registration is on line at
www.ariston.co.uk
The boiler must be installed in accordance with the manufacturers instructions
The boiler must be installed by a Gas Safe Registered engineer.
The installer must arrange for a Building Regulations Compliance Certificate to be issued to the boiler owner.
The Building Regulations Compliance Certificate is to be made available upon request by any attending Ariston
service representative.
The Benchmark commissioning checklist, which can be found at the back of the Installation instructions, must be
completed in full by the installer.
The completed Benchmark checklist must be left with the boiler or be made available upon request by any attending
Ariston representative.
The boiler must be serviced by the 12 month anniversary of the installation. This must be carried out by a Gas Safe
Registered engineer.
Proof of annual service must be made available upon request by any attending Ariston representative.
The boiler must be installed on a clean system and corrosion inhibitors added.
All of the above are standard procedures which a competent installer will be aware of.
Failure to comply with any of the above will result in any guarantee being withdrawn.