7910 Series Programmable Counter
Designed for industrial machine and process
control applications, the 7910 Series provides
a full complement of programmable features
including bidirectional counting modes,
programmable output logic and hold times,
and RS-422 or RS-232 data communications. A
unique dual-counter-mode lets the Series 7910
replace the functions of two predetermining
counters in some applications.
Among the 7910 Series’ convenience oriented
features are rugged screw-terminal strips for
easy wiring, 115/230 VAC dual operating voltage,
and a regulated DC voltage output with enough
capacity to support two encoders. • Two high-speed counting registers with
separate calibration factors
• Quick and easy setup using built-in “library”
of popular programs
• Add/subtract, count/direction, or
quadrature bidirectional input modes
• Big, bright, high-contrast red LED display
• Control outputs from two 5 amp rated
relays, plus solid state outputs
• Nonvolatile memory for all programmed,
preset, and counted data
• Sealed, NEMA-4 rated front panel; dust-free
and water-tight
• Direct access keys for all operating
functions – no “shifts or scrolls”
• Data communications port for printer or
computer interface
• Built-in self-diagnostics and power line fault
detection
TIME COUNT MEASURE DISPLAY
1.800.390.6405 www.veeder-rootcounters.com
2100 West Broad Street
[email protected] Elizabethtown, NC 28337
ESVR 09082016
7910 Series Programmable Counter
SPECIFICATIONS DIMENSIONS
INPUT POWER Selectable 115/230 VAC, 50/60 Hz, 20 VA maximum
ACCESSORY POWER DC output provided for transducer, 15 VDC ±5%, 160mA maximum
DISPLAY 6 digit, 0.56” (14.2 mm) red LED
DECIMAL POINT Selectable decimal point location
Sealed membrane; rated NEMA-4 when unit is panel mounted
KEYBOARD
with gasket provided
Two separate 6 decade counting registers with assignable
CONFIGURATION
preset limits, and operating modes
Separate input scaling for count registers A and B; Range:
CALIBRATOR
0.0001 to 9.9999
2 individual, 6 digits each; may be individually assigned to
PRESET LIMITS
count register A or B
Up Mode: Resets to zero, processes presets when count matches
limit value; Down Mode: Resets to preset limit value, outputs are
PRESET MODES actuated at zero and second preset limit (if used); Totalizer Mode:
Count register A or B can operate as totalizer if not assigned preset
limit
COUNTING MODES Add/add, add/subtract, count/direction, quadrature
INPUT LOGIC X1, X2, X4 (quadrature only)
Maximum 10 kHz count rate with single input driven, 7.5 kHz
COUNT RATE
with both inputs driven
Open collector (sinking), or contact closure (programmable
SIGNAL INPUTS
input filter)
Reset A, reset B, and stop count (commands initiated when
CONTROL INPUTS
switched to common)
2 form-C relays, rated at 5 amp/230 VAC, maximum; 2
CONTROL OUTPUTS
NPN transistor (sinking); 30 VDC/150 mA, maximum
RESET Front panel push-button, remote, programmable automatic
SECURITY Selectable locks for reset, preset, and program mode
DIAGNOSTICS Tests for control inputs, outputs, panel keys, and display
RS-422, RS-232, See ordering table; 7 bit ASCII plus parity;
COMMUNICATIONS
Baud rate to 2400
OPERATING
+32° to +122°F (0 to +50°C)
TEMPERATURE
WEIGHT 2.5 lbs. (1.1 kg)
ORDERING INFORMATION
Standard Models
0791086-210 UL/CSA, RS-422 Data
0791086-220 UL/CSA, RS-232 Data
Special variations may be available. Please consult factory.
1.800.390.6405 www.veeder-rootcounters.com
2100 West Broad Street
[email protected] Elizabethtown, NC 28337