0% found this document useful (0 votes)
79 views2 pages

7910 Datasheet

The 7910 Series Programmable Counter is designed for industrial machine and process control, featuring bidirectional counting modes, programmable output logic, and RS-422 or RS-232 communication. It includes dual high-speed counting registers, a bright LED display, and a NEMA-4 rated front panel for durability. Additional features include nonvolatile memory, built-in self-diagnostics, and easy setup with a library of popular programs.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
79 views2 pages

7910 Datasheet

The 7910 Series Programmable Counter is designed for industrial machine and process control, featuring bidirectional counting modes, programmable output logic, and RS-422 or RS-232 communication. It includes dual high-speed counting registers, a bright LED display, and a NEMA-4 rated front panel for durability. Additional features include nonvolatile memory, built-in self-diagnostics, and easy setup with a library of popular programs.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

7910 Series Programmable Counter

Designed for industrial machine and process


control applications, the 7910 Series provides
a full complement of programmable features
including bidirectional counting modes,
programmable output logic and hold times,
and RS-422 or RS-232 data communications. A
unique dual-counter-mode lets the Series 7910
replace the functions of two predetermining
counters in some applications.

Among the 7910 Series’ convenience oriented


features are rugged screw-terminal strips for
easy wiring, 115/230 VAC dual operating voltage,
and a regulated DC voltage output with enough
capacity to support two encoders. • Two high-speed counting registers with
separate calibration factors
• Quick and easy setup using built-in “library”
of popular programs
• Add/subtract, count/direction, or
quadrature bidirectional input modes
• Big, bright, high-contrast red LED display
• Control outputs from two 5 amp rated
relays, plus solid state outputs
• Nonvolatile memory for all programmed,
preset, and counted data
• Sealed, NEMA-4 rated front panel; dust-free
and water-tight
• Direct access keys for all operating
functions – no “shifts or scrolls”
• Data communications port for printer or
computer interface
• Built-in self-diagnostics and power line fault
detection

TIME COUNT MEASURE DISPLAY

1.800.390.6405 www.veeder-rootcounters.com

2100 West Broad Street


[email protected]
Elizabethtown, NC 28337
ESVR 09082016

7910 Series Programmable Counter

SPECIFICATIONS DIMENSIONS
INPUT POWER Selectable 115/230 VAC, 50/60 Hz, 20 VA maximum

ACCESSORY POWER DC output provided for transducer, 15 VDC ±5%, 160mA maximum

DISPLAY 6 digit, 0.56” (14.2 mm) red LED

DECIMAL POINT Selectable decimal point location

Sealed membrane; rated NEMA-4 when unit is panel mounted


KEYBOARD
with gasket provided

Two separate 6 decade counting registers with assignable


CONFIGURATION
preset limits, and operating modes

Separate input scaling for count registers A and B; Range:


CALIBRATOR
0.0001 to 9.9999

2 individual, 6 digits each; may be individually assigned to


PRESET LIMITS
count register A or B

Up Mode: Resets to zero, processes presets when count matches


limit value; Down Mode: Resets to preset limit value, outputs are
PRESET MODES actuated at zero and second preset limit (if used); Totalizer Mode:
Count register A or B can operate as totalizer if not assigned preset
limit

COUNTING MODES Add/add, add/subtract, count/direction, quadrature

INPUT LOGIC X1, X2, X4 (quadrature only)

Maximum 10 kHz count rate with single input driven, 7.5 kHz
COUNT RATE
with both inputs driven

Open collector (sinking), or contact closure (programmable


SIGNAL INPUTS
input filter)

Reset A, reset B, and stop count (commands initiated when


CONTROL INPUTS
switched to common)

2 form-C relays, rated at 5 amp/230 VAC, maximum; 2


CONTROL OUTPUTS
NPN transistor (sinking); 30 VDC/150 mA, maximum

RESET Front panel push-button, remote, programmable automatic

SECURITY Selectable locks for reset, preset, and program mode

DIAGNOSTICS Tests for control inputs, outputs, panel keys, and display

RS-422, RS-232, See ordering table; 7 bit ASCII plus parity;


COMMUNICATIONS
Baud rate to 2400

OPERATING
+32° to +122°F (0 to +50°C)
TEMPERATURE

WEIGHT 2.5 lbs. (1.1 kg)

ORDERING INFORMATION
Standard Models

0791086-210 UL/CSA, RS-422 Data


0791086-220 UL/CSA, RS-232 Data

Special variations may be available. Please consult factory.