0% found this document useful (0 votes)
0 views

Raid

The document discusses the use of Redundant Arrays of Inexpensive Disks (RAID) to improve disk performance and reliability through striping and redundancy. It outlines various RAID levels, including RAID 0 (non-redundant), RAID 1 (mirrored), and RAID 5 (distributed parity), highlighting their trade-offs in terms of performance and data protection. Additionally, it addresses the complexities of managing multiple disks and the challenges associated with booting from RAID configurations.

Uploaded by

nafyjabesa1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
0 views

Raid

The document discusses the use of Redundant Arrays of Inexpensive Disks (RAID) to improve disk performance and reliability through striping and redundancy. It outlines various RAID levels, including RAID 0 (non-redundant), RAID 1 (mirrored), and RAID 5 (distributed parity), highlighting their trade-offs in terms of performance and data protection. Additionally, it addresses the complexities of managing multiple disks and the challenges associated with booting from RAID configurations.

Uploaded by

nafyjabesa1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 13

CSE 451: Operating Systems

Winter 2013

Redundant Arrays of Inexpensive Disks


(RAID)
and OS structure

Gary Kimura
The challenge
• Disk transfer rates are improving, but much less fast
than CPU performance
• We can use multiple disks to improve performance
– by striping files across multiple disks (placing parts of each
file on a different disk), we can use parallel I/O to improve
access time
• Striping reduces reliability
– 100 disks have 1/100th the MTBF (mean time between
failures) of one disk
• So, we need striping for performance, but we need
something to help with reliability / availability
• To improve reliability, we can add redundant data to
the disks, in addition to striping
2
RAID
• A RAID is a Redundant Array of Inexpensive Disks
• Disks are small (physically) and cheap, so it’s easy to
put lots of disks (10s to 100s) in one box for
increased storage, performance, and availability
• Data plus some redundant information is striped
across the disks in some way
• How striping is done is key to performance and
reliability

3
Some RAID tradeoffs
• Granularity
– fine-grained: stripe each file over all disks
• high throughput for the file
• limits transfer to 1 file at a time
– coarse-grained: stripe each file over only a few disks
• limits throughput for 1 file
• allows concurrent access to multiple files
• Redundancy
– uniformly distribute redundancy information on disks
• avoids load-balancing problems
– concentrate redundancy information on a small number of
disks
• partition the disks into data disks and redundancy disks

4
RAID Level 0
• RAID Level 0 is a non-redundant disk array
• Files are striped across disks, no redundant info
• High read throughput
• Best write throughput (no redundant info to write)
• Any disk failure results in data loss; sometimes a file,
sometimes the entire volume

5
RAID Level 1
• RAID Level 1 is mirrored disks
• Files are striped across (half) the disks
• Data is written to multiple (two) places – data disks
and mirror disks
• On failure, just use the surviving disk(s)
• Factor of N (2x) space expansion

data disks mirror copies

6
RAID Levels 2, 3, and 4
• RAID levels 2, 3, and 4 use ECC (error correcting
code) or parity disks
– E.g., each byte on the parity disk is a parity function of the
corresponding bytes on all the other disks
• A read accesses all the data disks
• A write accesses all the data disks plus the parity
disk
• On disk failure, read the remaining disks plus the
parity disk to compute the missing data
data disks parity disk

7
Refresher: What’s parity?

1 0 1 1 0 1 1 0 1

• To each byte, add a bit set so that the total number of


1’s is even
• Any single missing bit can be reconstructed
• (Why does memory parity not work quite this way?)

8
RAID Level 5
• RAID Level 5 uses block interleaved distributed parity
• Like parity scheme, but distribute the parity info (as
well as data) over all disks
– for each block, one disk holds the parity, and the other disks
hold the data
• Significantly better performance
– parity disk is not a hot spot
data & parity drives

0 1 2 3 PO
File Block
5 6 7 P1 4 Numbers

10 11 P2 8 9

9
Management
• Multiple spindles complicates things
– Visible to: Apps? File system?
– Allocation of space (per user on a “file server”)
– SANs
– Differing disk sizes
• Partitions!
– Logical division of spindle into blocks
– Assemble volumes from partitions

10
OS and Hardware Layering
• Who needs to know?
Operating System
– FS: probably not
File System

Fault Tolerance

Volume Manager

Device Driver

Disk Controller

Disk 0 Disk 1 Disk 2

11
OS and Hardware Layering
• Why put FT into hardware?
– Speed
– Simplicity of OS Operating System
• Why not?
– Fixes File System
– CvI data
Volume Manager

Device Driver

Disk Controller w/ FT

Disk 0 Disk 1 Disk 2

12
One tiny problem with RAID and multiple
spindles…
• How do you boot?
– ROM on motherboard doesn’t have a lot of room for logic
– Boot zone on disk doesn’t have a lot of room for logic (and
needs to be replicated, striped, etc.)
– Put partition info into “well-known place”
– Put RAID info into “well-known place”
– Still… too complicated
• “Real systems”…
– Don’t boot from multi-partition volumes
– Boot from RAID 0, at most RAID 1 (simple failover)

13