STIX A200 MULTI VINYL is a multi-purpose acrylic adhesive designed for laying various soft floor coverings, including PVC and natural fibers. It features rapid curing, high initial grab, and is suitable for both residential and commercial projects, with a recommended application temperature of +10°C to +30°C. The product has a shelf life of 12 months and requires proper subfloor preparation and cleaning for optimal performance.

Uploaded by

saifu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
23 views3 pages

Bostik TDS Stix A200 Multi Vinyl

STIX A200 MULTI VINYL is a multi-purpose acrylic adhesive designed for laying various soft floor coverings, including PVC and natural fibers. It features rapid curing, high initial grab, and is suitable for both residential and commercial projects, with a recommended application temperature of +10°C to +30°C. The product has a shelf life of 12 months and requires proper subfloor preparation and cleaning for optimal performance.

Uploaded by

saifu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

MULTI-PURPOSE ADHESIVE FOR ALL VINYL COVERINGS

KEY BENEFITS

• Rapid curing
• High initial grab
• PVC bonding on old PVC

APPLICATIONS PRODUCT CHARACTERISTICS

DESCRIPTION Colour Ivory


STIX A200 MULTI VINYL is a multi-purpose acrylic
adhesive for laying soft floor covering:
Composition Acrylic water based
homogeneous and heterogeneous PVC, carpet
with any type of backing, and natural fibres.
Storage / Shelf life* 12 months
DESTINATION
Application
It’s a universal multi-purpose adhesive suitable for +10°C to +30°C
temperature
the installation of most soft floor coverings.
For all types of resilient flooring in residential and Waiting time** 10-15min
commercial projects.
Also suitable for shower units with PVC floors and Open time** 45-50min
walls
Recommended by most of the manufacturers Walk on time** 12 hours
For interior use only.
Curing time* 24 to 48 hours
Associated floor coverings :

 Homogeneous and heterogeneous PVC Coverage 250-400 g/m²


sheeting and tiles
 Cork with PVC backing Frost sensitivity Reversible up to 0°C
 Expanded vinyl
 Semi-flexible tiles
 Textiles: needle punch with or without backing,
*from date of manufacture in original, unopened packaging,
foam clear of the ground, in cool, dry conditions within the
 Non-woven textile floor coverings temperature range +5°C to +25°C and out of direct sunlight.
 Natural fiber floor coverings (Coir, sisal and sea Protect from frost, damp, condensation and dew.
grass). **these times are determined at + 23° C and 50 % relative
humidity on normally absorbent substrates
DIRECTIONS FOR USE
Bond the floor covering by applying a rubbing block
PREPARATION and/or roller to expel trapped air and ensure good
Subfloor: transfer of the adhesive. Repeat after 30 minutes to
expel trapped air and ensure good contact.
Ensure the subfloor is in accordance with building
standards. Subfloors must be clean, sound, dry Do not weld the joints before the adhesive has had
(<75%RH), and free from contaminants that may sufficient time to develop a good bond (approx. 24 to 48
impair adhesion e.g. dust, grease, paint, plaster, hours after installation).
polish, water softenable adhesive etc.
CLEANING
For subfloors that are not sufficiently smooth or Clean tools and equipment with warm water
require height build up to receive the particular immediately after use. Remove any adhesive from
floor covering being bonded, an application of a the surface of the floor covering with a damp
suitable Bostik self-levelling compound and cloth.
primer system is recommended. Please consult
Technical Services for advice on specific products
and subfloors. Code UC PCB PALLET. GENCOD

30615675 6 kg 1 80 3549212484828
Very absorbent subfloors such as open textured
screeds and plywood should be primed prior to 30615552 20 kg 1 32 3549212484804
applying adhesive, with a suitable Bostik primer.
Priming reduces over-absorption of the adhesive
into the substrate, giving a good working time and
strong adhesive bond.

Before applying any adhesive, ensure the


substrate is dry and dust free.

Underfloor heating systems:


Underfloor heating systems must be switched off
for 48 hours before installation. Wait 7 days after
installation before gradually turning up
underfloor heating.

APPLICATION
Select appropriate trowel size and application
method for the floor covering and apply the
adhesive evenly onto the subfloor, holding the
trowel at an angle of 60°. Leave the adhesive for
the appropriate open time.
TROWEL
FLOOR COVERING CONSUMPTION
SIZE
Coverings with a
smooth backing SAFETY
A2 0.2kg - 0.25kg/m²
(PVC tiles and strips,
E.V.R., foams) For more details, consult the safety data sheet on
short wool Roll with a short https://bostiksds.thewercs.com/default.aspx
Thin coverings to
roller (such wool roller and
avoid glue streaks
as a lacquer then lay on the
during use
roller) wet adhesive film
Coverings with a The information given and recommendations made herein are based on
B1 0.3kg - 0.35kg/m² Bostik’s research only and are not guaranteed to be accurate. The
textured backing performance of the product, its shelf life, and application characteristics
will depend on many variables, including the kind of materials to which the
Coverings with a product will be applied, the environment in which the product is stored or
high relief on the applied, and the equipment used for application. Any change in any of these
B2 0.4kg - 0.45kg/m² variables can affect the product’s performance. It is the buyer’s obligation,
reverse side (e.g. coir prior to using the product, to test the suitability of the product for an
intended use under the conditions that will exist at the time of the
with latex backing) intended use. Bostik does not warrant the product’s suitability for any
particular application. The product is sold pursuant to Bostik’s Terms and
Conditions of Sale that accompanies the product at the time of sale.
To minimise the effect of adhesive serrations Nothing contained herein shall be construed to imply the nonexistence of
showing through thin floor coverings, pre-wet a any relevant patents or to constitute permission, inducement, or
recommendation to practice any invention covered by any patent, without
roller with adhesive and flatten what has been authority from the owner of the pat
applied to the subfloor.

DRYING TIME BOSTIK TECHNICAL ASSISTANCE

The 10-15 minutes waiting time must be Smart Help +XX XX XXX XXX
respected to minimize the risk of puddle
formation (except for linoleum).

Lay the floor covering while the adhesive remains


tacky and receptive.
SUBFLOOR PREPARATION COVERAGE

From 250 to 400 g/m² depending on the type of


CLEANING PREPARATION coating and the spatula used.
Preparation should be in accordance with building
standards. Subfloors must be sound, smooth,
permanently dry and free from old adhesive
residues, dust, grease or other contaminants.
STORAGE STABILITY
When overlaying existing floor coverings ensure
that they are firmly bonded and clean.
Remove dirt, polish, oil and similar contaminating Up to 12 months in the original unopened
substances. container stored between +10°C and +30°C. Frost-
Need to comply with local regulation and mostly sensitive
prepared with a self-leveling compound
associated with Bostik primers.
Very absorbent surfaces must be primed to
prevent over absorption. Anhydrite screeds as CLEANING
well as particleboards and plywood should be
primed with dedicated primer.
Always allow primers and self-levelling Tools should be cleaned with warm water,
underlayment to dry thoroughly before applying preferably whilst the adhesive is still wet.
the adhesive.

Code UC PCB GENCOD

METHOD OF USE 30615675 6 kg 1 3549212484828

Apply an even coat over the whole area to be 30615552 20 kg 1 3549212484804


covered using a suitable notched trowel
(depending on the porosity and roughness of the
substrate).

Type of floor covering or specific substrate


Notched trowel to be used (TKB standard)
Average consumption, per m²

- Very thin floor coverings with a smooth


backing on all types of substrates or floor
coverings with a smooth backing on non-
porous substrates (A4 type or by roller/ 200
g/m²)
- Floor coverings with a smooth backing (A2
type / 200-250 g /m²)
- Floor coverings with a slightly rough backing
(B1 type / 300-350 g/m²)

SAFETY
Bonding PVC onto PVC, impervious surfaces: open
time can vary from 30 to 90 minutes depending For more details, consult the safety data sheet on
on https://bostiksds.thewercs.com/default.aspx
ambient conditions and the quantity of adhesive
applied.
The information given and recommendations made herein are based on
Bostik’s research only and are not guaranteed to be accurate. The
performance of the product, its shelf life, and application characteristics
will depend on many variables, including the kind of materials to which the
product will be applied, the environment in which the product is stored or
applied, and the equipment used for application. Any change in any of these
variables can affect the product’s performance. It is the buyer’s obligation,
prior to using the product, to test the suitability of the product for an
intended use under the conditions that will exist at the time of the
intended use. Bostik does not warrant the product’s suitability for any
particular application. The product is sold pursuant to Bostik’s Terms and
Conditions of Sale that accompanies the product at the time of sale.
Nothing contained herein shall be construed to imply the nonexistence of
any relevant patents or to constitute permission, inducement, or
recommendation to practice any invention covered by any patent, without
authority from the owner of the pat

BOSTIK TECHNICAL ASSISTANCE

Smart Help +XX XX XXX XXX

You might also like