0% found this document useful (0 votes)
153 views32 pages

Neuron Ii Controller Manual

The NEURON II User Manual provides comprehensive information about the device's features, technical specifications, and operational instructions. It highlights energy-saving capabilities, user-friendly interface, and various control modes while detailing input/output descriptions and menu structures. The manual also includes troubleshooting sections and optional features to enhance functionality.

Uploaded by

ei.arakkonam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
153 views32 pages

Neuron Ii Controller Manual

The NEURON II User Manual provides comprehensive information about the device's features, technical specifications, and operational instructions. It highlights energy-saving capabilities, user-friendly interface, and various control modes while detailing input/output descriptions and menu structures. The manual also includes troubleshooting sections and optional features to enhance functionality.

Uploaded by

ei.arakkonam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 32

NEURON II

User Manual

Version 1.0 ● 2 April 2009


# Chapter Page
1.0 Salient Features 1
2.0 Technical Features 3
3.0 Input Output Description 4
4.0 Main Screen 7
5.0 Menu Structure 8
5.1 View 8
5.1.1Operator 9
5.1.2 Fault Report 10
5.1.3 Day Report 10
5.1.4 Service Time 10
5.1.5 Cumulative Time 11
5.1.6 VFD 11
5.2 Operator 11
5.2.1 Machine 12
5.2.2 Schedule 13
5.2.3 Maintenance 13
5.2.4 Language 13
5.2.5 Change Password 14
5.3 Service 14
5.3.1 Calibration 15
5.3.2 Relay 15
5.3.3 Change Password 16
5.3.4 Maintenance 16
5.3.5 Set Dew point 16
5.4 Factory menu 17
5.4.1 Machine 18
5.4.2 Self Test 19
5.4.3 Change Password 19
5.4.4 Clock 19
5.4.5 Integrator Dryer 20
5.5 Customer care 20
6.0 Controls 21
6.1 Start Sequence 21
6.2 Stop Sequence 23
6.3 Fan Control 24
6.4 ADV control 25
6.5 Dryer Control 25
7.0 Data Interface 26
7.1 Analog output 26
7.2 DCS Port 26
8.0 Construction & Dimension Drawing 27
9.0 Revision Details 28
10.0 Appendix 29
1.0 Salient features

Saves Money

 The ‘Smart Logic’ of NEURON II automatically decides the start delay required to ensure minimum wait time
between successive starts of the compressor and dryer thereby increasing their lifetime.
 Start Inhibit till sump pressure is within safe limits to enhance the life of the compressor
 Low Voltage & Short time Power Interrupts detection to enhance the life of the contactors
 Automatic Display Back-light Control to increase the Display Lifetime
 Data validation of critical parameters for protecting the compressor from improper usage.

Saves Energy

 Automatic Dryer ON/OFF Control to reduce power wastage


 Automatic Fan ON/OFF Control based on temperature to reduce power wastage
 Pressure Scheduling to allow user to plan for air requirements and avoid power wastage
 Dedicated VFD interface port for synchronized operation of integrated compressor with VFD
Saves Time

 Easy User Interface thro 8 line Graphical Display and intuitive menu navigation keys
 Regional Language menu & message display: Hindi, Chinese, Selective European Languages
 Mimic LED indication for fault diagnosis
 Easy to read Fault and Warning message display
 Cumulative Hours Display for Load, Unload, Run, Stop, Fault, Standby
 Total No of Start/Stop and Load/Unload Cycle Display
 Compressor Utilisation Display
 Service Remain Hours Display
 Dryer or Ambient Temperature (Pt100 sensor) Display
 Different Control Modes: Local, Remote & DCS
 Unload Mode for Service
 Pressure & Temperature Units Selectable PSI or Bar, Centigrade or Fahrenheit
 30 Day Report includes Date, Load, Unload, Run, Stop, Standby, Fault hours
 99 Fault Report includes Fault Code along with the Date, Time, Pressure, Temperature and Run Status
 MODBUS RTU protocol for monitoring the compressor through DCS interface (BAUD– 9600 / 19200)
 Analog Output for Pressure (Channel1), Temperature/Sump Pressure, Pt100 (Programmable on Channel2)
 Programmable Relay for Load, Warn, Trip, Standby, Service, Ready, Remote
 Easy Firmware update using a handheld programming device or a laptop

Optional Features

 Optional add-on Fault Predictive Device


o Eliminate the need for the customer to call for service or repair
o Compressor life could be increased by regular monitoring for problems
o Production can be maximized due to the minimal downtime
 Optional Add-on IO card further extends Input and Output
o 4 no’s of Isolated Digital Input
o 4 no’s of Relay Output
o 2 no’s of Analog Input, 4-20ma
o 2 no’s of Analog Input, RTD
2.0 Technical Features
8 no’s of Optically Isolated Digital Inputs of 24VDC
01 = Emergency stop
02 = Differential pressure oil filter
03 = Reverse Rotation
04 = Differential pressure separator element
05 = Remote Start/Stop
06 = High Sump Pressure
07 = Cooler
08 = Main Motor Overload
8 no’s of Output Relay (SPDT 250V AC 10A, 1, 00,000 cycle electric life)
01 = Main contactor
02 = Star contactor
03 = Delta contactor
04 = Load Valve
05 = Fan
06 = Auto Drain Valve
07 = Dryer (if Dryer is Connected) else Programmable
08 = Programmable [Load, Service, Standby, Warn, Trip, Remote, Ready]
4 no’s of Analog Input Channels
1 no of 4-20mA Channel, 0 to 16 bar for Discharge Pressure
1 no of 4-20mA channel, 0 to 16 bar for Sump Pressure
1 no of RTD (KTY10) channel, 0 to 150 degree C for Discharge Temperature
1 no of RTD (Pt-100) channel, -50 to +85 degree C for Drier or Ambient Temperature
2 no’s of Analog Output Channels
0 to 5 VDC, One for Discharge Pressure and One Programmable
9 no’s of Function keys
Up, Down, Left, Right, Enter, Escape, Start, Stop and Reset.
1 no of Display
128X64 White Backlight Graphical LCD
9 no’s of LED’s for visualization alarm status
Air Filter
Auto Restart
Main Motor
Main Motor Reverse Rotation
Pressure
Temperature
Differential Pressure Oil Filter
Cooler
Differential Pressure Separator Element
1 no. of Dual led for start/stop indication
Green for start and Red for stop
1 no. of Non – Volatile Memory
For storage of 30 Day & 99 Fault Reports
1 no. of Real Time Clock
With Battery life of about 10 years
4 no’s of Communication Port (RS485, 2 wire)
Serial Port 1: MODBUS-RTU or SCADA Port
Serial Port 2: Dedicated FPD Port
Serial Port 3: VFD Interface Port
Serial Port 4: Add-On I/O Interface Port
1 no. of In System Programming (ISP) port
Power Supply Input: 24VAC +/- 25%, 50Hz, 1A (Surge, Over Current and EMI Protected)
3.0 Input Output Description
X01: Power supply
Connector type: 3 pole combicon

Pin Function Id Active state


1 24V AC 24V AC -
2 Earth Earth -
3 24V AC 24V AC -

X02: Main Motor Relays


Connector type: 4 pole combicon

Pin Function Id Active state


1 Common for Main, Star and Delta Common -
contactors
2 Main Contactor Digital output 1 Energised
3 Star Contactor Digital output 2 Energised
4 Delta Contactor Digital output 3 Energised

X03: Relays
Connector type: 10 pole combicon

Pin Function Id Active state


1 Common - Load Relay Common
2 Load Relay Digital output 4 Load when energised
3 Common - Fan Relay Common
4 Fan Relay Digital output 5 Energised
5 Common - Auto Drain Valve relay Common
6 Auto Drain Valve Relay Digital output 6 Energised
7 Common – Dryer Relay Common
8 Dryer Relay Digital output 7 Energised
9 Common - Programmable Relay Common
10 Programmable Relay Digital output 8 Energised
X04: Digital inputs
Connector type: 11 pole combicon

Pin Function Id Active state


1 Digital Inputs Common – 24VDC 24VDC -
2 Emergency Stop Digital input 1 Fault if open
3 Differential Pressure Oil Filter Digital input 2 Fault if open
4 Reverse Rotation Digital input 3 Fault if closed
5 Differential Pressure Oil Separator Digital input 4 Fault if open
6 Remote Digital input 5 Stop if open/ start on
closure
7 High Sump Pressure Digital input 6 Fault if open
8 Cooler Digital input 7 Fault if open
9 Main Motor Overload Digital input 8 Fault if open
10 Ground GND24 -
11 No Connection - -

X05: Analog Inputs


Connector type: 8 pole combicon

Pin Function Id Type Range


1 Discharge pressure Analog input 1 4-20 ma 0 to 16 bar
2 15 to 18VDC
3 Discharge temperature Analog input 2 KTY10 0 to 150 °C
4 Discharge temperature
5 Sump Pressure Analog input 3 4-20 ma 0 to 16 bar
6 15 to 18VDC
7 Dryer or Amb temperature Analog input 4 Pt100 -50 to +85 °C
8 Dryer or Amb temperature

X06: Analog outputs and VFD


Connector type: 5 pole combicon

Pin Function Id Type Range


1 VFD Interface VFD-A RS485 A FC Protocol
2 VFD Interface VFD-B RS485 B
3 Ground 0VDC GND - -
4 Dis. Pressure Output Analog output 1 1 to 5V 0 to 16 bar
5 Programmable Analog Analog output 2 4-20 ma 0 to 160 C
Output 0 to 16 bar
-70 to 90C
X07: Communication
Connector type: 6 pole combicon

Pin Function Id Type Protocol


1 DCS Interface DCS A RS485 A Modbus
2 DCS Interface DCS B RS485 B
3 FPD Interface FPD A RS485 A ASCII
4 FPD Interface FPD B RS485 B
5 Add On Interface Add On A RS485 A Modbus
6 Add On Interface Add On B RS485 B
4.0 Main Screen
Dis. Pr : 6.0 bar

Dis. Tr : 32 °C
Dew. Pt* : 1 °C

Status
Warning Messages
HH:MM:SS 1 2 DD/MM

* If Dryer is enabled otherwise Ambient Temperature


Status: Either Fault message or Compressor Status
1 - Pressure schedule
- If Blank  Pressure Schedule is Disabled
- If “PS”  Pressure Schedule is Enabled
- If “PS” blinking  Waiting for Pressure Schedule Acknowledgement
2 - Control Mode
- L  Local, ON/OFF Control from Local Keypad
- R  Remote, ON/OFF Control from Remote Input
- D  DCS, Control is from DCS System
- M  Manual, Start need to given after Power failure
- A  Auto, Compressor will Automatically Restart after power failure

Status Messages Fault Messages Warning Messages


Ready HSP DPSE
Star Cooler DPOF
Run Pressure Probe Failure Dryer Probe Failure
Run Load Temperature Probe Failure Low Dew Point
Run Unload Main Motor Overload High Dew Point
Stop Busy Reverse Rotation High Differential pressure
Idle Trip Temperature Warn Temperature
Emergency Stop Sump Pressure Not Developing Low Voltage (All
Start Inhibit Sump Pressure probe Failure Controller Operations are
Start ack Power failure Suspended)
(acknowledgement )
wait
5.0 Menu Structure
Press any one of the following keys ▲, ▼, ◄and ► to enter main menu

Main Menu

Dis. Pr : 6.0 bar


Dis. Tr : 32 ° C
Status
► View
Operator
Service
Factory
Customer Care

5.1 View

View

Operator Fault Day Service Cumulative VFD


Report Report Time Time
5.1.1 Operator

LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4


View Operator Mode Control mode Local / Remote / DCS
Unload Mode Enable / Disable
Auto Restart ON/ OFF
Pressure Unit PSI / Bar
Temperature Unit Fahren / Centi

Pressure Unload pressure XX.X


Load pressure XX.X
Pr. Schedule ON/ OFF
Sump Pressure XX.X
Diff Pr XX.X

Delay Warn RST delay X X X sec


Star delay X X sec
DTR delay X X sec
RTS delay X X sec
Stanby Time Sby X X min
St/Sp PH X X

DCS port Type Modbus / SCADA


Baud 9600/19200
Parity None / Even
Length 8/7
Stop Bit 2 / 1

Temperature Trip Temperature XXX


Warn Temp XXX
Fan Temp XXX
Low Dew Pt XX
High Dew Pt XX
5.1.2 Fault Report

Use ▲, ▼ to select the Fault Record number (1 to 99).

LEVEL 1 LEVEL 2 LEVEL 3


View Fault report Fault code: XX, Message
Time: HH:MM:SS
Date: DD/MM/YY
Dis.Pr: X X .X
Dis.Tr: XXX
Status: Load/ UnLoad /OFF

Fault Code:
01 & 09 – Reserved
02-Main Motor Overload, 03-Cooler, 04-HSP(Analog), 05–Trip Temperature, 06-
Reverse Rotation, 07-Pressure Probe Failure, 08-Temperature Probe Failure, 0A-
HSP(Digital), 0B-Power Failure( Short Power Interrupt), 0C-Sump Pressure Not
Developing , 0D-Sump Pressure probe Failure.

5.1.3 Day Report

Use ▲, ▼ to select the Record number (1 to 30).

LEVEL 1 LEVEL 2 LEVEL 3


View Day report Date: DD/MM/YY
Load: X X Hours
UnLoad: X X Hours
Run: X X Hours
Stop: X X Hours
Fault: X X Hours
Standby: X X Hours

5.1.4 Service Time


LEVEL 1 LEVEL 2 LEVEL 3
View Service time Remaining AFCT: X X X X X X hours
Remaining OFCT: X X X X X X hours
Remaining OSCT: X X X X X X hours
Remaining OCT: X X X X X X hours
Remaining RGT: X X X X X X hours
5.1.5 Cumulative Time
LEVEL 1 LEVEL 2 LEVEL 3
View Cumulative time Load X X X X X X hrs: X X Min
Unload X X X X X X hrs: X X Min
Run X X X X X X hrs: X X Min
Stop X X X X X X hrs: X X Min
Fault X X X X X X hrs: X X Min
Standby X X X X X X hrs: X X Min
Start Count X X X X X X hrs: X X Min
Load Count X X X X X X hrs: X X Min
Utilisation XX%

5.1.6 VFD
If VFD is connected to the compressor and VFD port is connected, use can view the
following parameters of VFD in Neuron II.
1. Voltage in V
2. Current in A
3. Frequency in Hz
4. Power in KW
5. Run Hours
6. Kilowatt Hour
7. Status of the VFD

5.2 Operator
Password required.

Operator

Machine Schedule Maintenance Language Change


Password

Mode Pressure Set Delay DCS Port Auto Drain


Valve
5.2.1 Machine
# Item Min Max Option Default Unit
Mode
1 Auto Restart - - on / off off -
2 Pr Unit - - bar / psi bar -
3 Tr Unit - - cen / fah cen -
4 Control - - loc/rem/dcs loc -
mode
5 Unload - - en/dis dis -
mode
6 Analog - - Tmp / Sp / Tmp -
output Pt
Pressure
7 Unload > load < max unload - 6.5 bar bar/psi
Pressure pressure+0.5 pressure (bar)
(bar)
8 Load 4.0 (bar) < unload - 4.5 bar bar/psi
Pressure pressure-0.5
(bar)
Set Delay
9 Warn RST 90 300 - 90 second
10 Star 6 10 - 6 second
11 DTR 10 60 - 10 second
12 RTS 5 30 - 10 second
13 Standby 1 99 - 5 minute
14 St/Sp per hr 3 10 - 5 -
DCS Port
15 Type - - Modbus modbus -
/SCADA
16 Baud - - 9600/19200 9600 bps
17 Parity - - None /Even None -
18 Length - - 8/7 8 -
19 Stop Bit - - 2/1 2 -
Auto Drain Valve
20 Off time 1 150 - 4 minute
21 On time 1 15 - 5 second
5.2.2 Schedule

Enable Pressure Schedule, and then use ▲, ▼ to select the schedule number (1 to 32).

Then Press “Enter” to set the following

# Item Min Max Option Default Unit


1 Day - - Sun to Sat / --- -
--- (means no
schedule)
2 Action - - on / off off -
3 Time HH 00 24 - 00 Hour
4 Time MM 00 59 - 00 Minute
5 Unload > Load < Max - 6.5 bar bar/psi
Pressure Pressure Unload
+ 0.5 Pressure
(bar) (bar)
6 Load Pressure 4.0 bar < Unload - 4.5 bar bar/psi
Pressure –
0.5 (bar)

5.2.3 Maintenance
# Item Min Max Option Default Unit
1 AF changed - - no/yes no -
2 OF changed - - no/yes no -
3 OS changed - - no/yes no -
4 Oil changed - - no/yes no -
5 Re Grease - - no/yes no -

5.2.4 Language
# Item
1 English
2 Hindi
3 Portuguese
4 Chinese

Note: Various Languages will be available depending on the software version


5.2.5 Change Password

Procedure for changing the password


1. Enter the old Password
2. If old password is correct, next screen is displayed. If wrong the control comes
out of the change password screen.
3. Enter the New password
4. Enter the New password again
5. If the new password matches both the times then new password is updated. If
mismatch the control goes back to step 3.
Pressing Esc will bring the control to the main menu screen

5.3 Service
Password required.

Service

Calibration Relay Change Maintenance Set Dew


Password point
5.3.1 Calibration
Select the parameter need to calibrated using the ▲, ▼keys. Then Press “Enter” to
calibrate.

Dis Pressure/ Dis Temperature/ Sump Pressure Calibration


Run the Compressor. When the value is stable at some point, measure the actual value
using a standard & recently calibrated meter and enter the meter reading in to the set
value field displayed in Neuron II. Set Value should not exceed +/- 1 bar, +/- 10 C.

Pt 100 Calibration
When the Dew point/ Ambient Temperature is stable at some point, measure the actual
value using a standard & recently calibrated meter and enter the meter reading in to the
set value field displayed in Neuron II. Set Value should not exceed +/- 3 C.

Note: Calibration for Pressure values will be only in bar and for temperature values only
in Centigrade.

5.3.2 Relay

Select the Programmable Relay 1 or 2 using the ▲, ▼keys. Then Press “Enter” to assign
the any one of the following functionality for the relay.

# Item
1 Warn
2 Load
3 Service
4 Standby
5 Trip
6 Remote
7 Ready

Note: If Dryer is enabled then Programmable Relay 2 is not user programmable.


Relay 2 is used for automatic dryer control.
5.3.3 Change Password

Procedure for changing the password


1. Enter the old Password
2. If old password is correct, next screen is displayed. If wrong the control comes
out of the change password screen.
3. Enter the New password
4. Enter the New password again
5. If the new password matches both the times then new password is updated. If
mismatch the control goes back to step 3.
Pressing Esc will bring the control to the main menu screen

5.3.4 Maintenance
# Item Min Max Option Default Unit
1 Set AFCT 000000 999999 - 002000H Hour
2 Set OFCT 000000 999999 - 002000H Hour
3 Set OSCT 000000 999999 - 002000H Hour
4 Set OCT 000000 999999 - 002000H Hour
5 Set RGT 000000 999999 - 002000H Hour

5.3.5 Set Dew point


# Item Min Max Option Default Unit
1 Low Dew point -6 C +2 C - -2 C C/F
2 High Dew point 6C 12 C - 8C C/F
5.4 Factory menu
Password required.

Factory

Machine Self Test Change Clock Integrated


Password Dryer

Compressor DPSE DPOF Max. Temperature


Info Pressure Settings
Settings
5.4.1 Machine
# Item Min Max Option Default Unit
Compressor Info
1 Device ID 01 99 - 01 -
2 Rating - - 11 to 315 11 KW
3 Pressure - - 7.0 to 12.5 7.0 bar
4 Fab no 000000 999999 - 000001 -

5 DPSE - - on/off off -

6 DPOF - - on/off off -


Max. Pressure Settings
7 High Sump > Max < Max - 12.0 bar bar
Pressure Unload Unload /psi
pressure +1 pressure
+3
8 Max UL > Unload < 13.5 bar - 11.1 bar bar
Pressure Pressure /psi
9 Sump - - enable/disable off -
Pressure
10 Start Sump 0.0 bar 16.0 bar - 2.2 bar bar
Pressure /psi
11 Max. 0.0 bar 2.0 bar - 1.0 bar bar
Differential /psi
Pressure
Temperature Settings
12 Trip 110 C 120 C - 110 C C/F
temperature
13 Warn 90 C 110 C - 105 C C/F
temperature
14 Fan 60 80 C - 70 C C/F
temperature
5.4.2 Self Test
Self Test for testing the Controller Display, Mimic Leds, Keys, Input/Output, Memory &
Communication Ports working.
Follow the instructions displayed in the screen

Warning!!!

Self Test should be conducted only when the compressor wiring is totally disconnected
from the controller. Do NOT perform self test when the controller is connected to the
compressor. Doing so will cause severe damage to the compressor.

5.4.3 Change Password


Procedure for changing the password
1. Enter the old Password
2. If old password is correct, next screen is displayed. If wrong the control comes
out of the change password screen.
3. Enter the New password
4. Enter the New password again
5. If the new password matches both the times then new password is updated. If
mismatch the control goes back to step 3.
Pressing Esc will bring the control to the main menu screen

5.4.4 Clock
# Item Min Max
1 Hour 00 23
2 Minute 00 59
3 Second 00 59
4 Date 01 31
5 Month 01 12
6 Year 00 99
7 Day Sun/Mon/Tue/Wed/Thu/Fri/Sat
5.4.5 Integrator Dryer
# Item Min Max Option Default Unit
1 Dryer Mode - - on/off off -
2 Dryer Start 2 10 - 6 Minute
Delay

5.5 Customer care

Dis. Pr : 6.0 bar


Dis. Tr : 32 °C
Status
Toll Free No
1800-425-3544

e-mail
[email protected]
6.0 Controls

ON Exit loop
6.1 Start Sequence Command

FAULT? Yes

No
Standby

AUTO Yes Dis. Pr. No


mode <Load Pr
ON?

No Yes

Yes Standby No AUTO


Standby Control ? ON from Yes
Power
Failure?

No
No Warn Restart
Sump Pr. Yes Sump Pr. Delay
< Set Enabled?
value?

Yes
No
Delay
60 Sec Sump Pr.
Sump Pr. Yes
Start Sequence < Set
Enabled?
value?
No
Yes
Start Sequence
Start Sequence

STAR
ON

Delay for 100msecs


(Fixed)

MAIN ‘ON’

NO. OF. START


INCREMENT

STAR TO DELTA delay ‘x’ sec


(Star delay)

STAR OFF

DELTA ON

Delta to run delay ‘x’ sec


(DTR delay)

Exit loop
6.2 Stop Sequence
Stop

Is Yes
STAR ON

No

LOAD “OFF”

(RTS delay)
Run to stop ‘x’ sec

DELTA & MAIN


OFF

“IDLE” delay for 5 secs


Fixed delay

READY
6.3 Fan Control

State = Run?
No

Dis. Temp No
> Set FAN
Temp

Yes

FAN ‘ON’

Exit Loop

FAN No
= ON?

Exit Loop
Yes

Dis. Temp No
< (Set FAN
Temp – 5 C)

Yes

FAN OFF
6.4 ADV control
As per the User set On & Off time the Drain Valve is automatically controlled.

On time

Off time

6.5 Dryer Control Dryer ON command generates


internally when Compressor
motor starts running

Calculate elapsed time from


last stop

Is No
Elapsed time>set
dryer delay ?

Yes

Dryer ON

Dryer OFF when Compressor is stopped


7.0 Data Interface

Neuron II has two types of Data Interface

• Analog 0 to 5V

• DCS Port

7.1 Analog output

Two Channels are available as analog output. The First Channel will output the current
Discharge Pressure value 0.0 to16.0 bar, converted into 1 to 5V.

The Second channel is programmable. User can select any one of the following
a. Dis. Temperature 0 to 160 C, converted into 1 to 5V
(Even though the output is till 160 C, maximum value will be only 150 C)
b. Sump Pressure 0 to 16.0 bar, converted into 1 to 5V
c. Pt100 Temperature -75 to 85 C, converted into 1 to 5V
(Even though the output is -75 to 85 C, minimum value will be only -50 C)

7.2 DCS Port

DCS port can be of Modbus RTU type to interface to Generic DCS system or SCADA
type to interface to ELGI SCADA software. User can select the Port type in menu.
Also the Baud Rate, Parity, data Length, Stop Bit are user settable. The Modbus data
table is provided in the Appendix.
8.0 Construction
 Corrosion & Dust protected Back Cover
 IP65 polyethylene front keypad
 Inputs and Outputs through terminal block, board to wires, disconnect able, screw terminals
 Front Plate Dimensions 260 x 145mm
 Enclosure Dimensions 235 X 120 X 70 mm
 Operating Temperature - 0ºC to +75ºC
 Relative Humidity <85% RH non-condensing @ 40ºC

8.1 Dimension Drawing

Panel Front Plate


260

145

Panel Cut out Dimension


70 235

X01 X06
120

X04
120

X07
X05 ISP X02 X03

All Dimensions are in mm


9.0 Revision Details

Version Date Changes


1.0 2 April 2009 Initial Draft
10.0 Appendix

APPENDIX A: MODBUS TABLE: [Function Code: 0x03(Read) & 0x10(Write)]

# Item Address Type Access


Mode Registers
1 Control Mode 1000 Integer R
2 Unload Mode 1002 Integer R
3 Auto Restart 1004 Integer R
4 Pr Unit 1006 Integer R
5 Tr unit 1008 Integer R
6 Pr. Schdl(on/off) 100A Integer R
Delay Registers
7 Auto restart Delay 1100 Integer R
8 Star Delay 1102 Integer R
9 DTR Delay 1104 Integer R
10 RTS Delay 1106 Integer R
11 Standby Time 1108 Integer R
12 St/Sp ph 110A Integer R
Cumulative Time & Count Registers
13 Load Hours 1200 Long R
14 Unload 1204 Long R
15 Run 1208 Long R
16 Stop 120C Long R
17 Fault 1210 Long R
18 Sby 1214 Long R
19 No of Start 1218 Long R
20 Load Count 121C Long R
21 Utilization 1220 Integer R
Service Remaining Time Registers
22 Rem AFCT 1300 Long R
23 Rem OFCT 1302 Long R
24 Rem OSCT 1304 Long R
25 Rem OCT 1306 Long R
26 Rem RGT 1308 Long R
Analog Registers
27 Dis. Pressure 1400 Integer R
28 Dis. Temperature 1402 Integer R
29 Dew Point / Ambient temperature 1404 Integer R
30 Sump Pressure 1406 Integer R
31 Unload Pressure 1408 Integer R/W
32 Load Pressure 140A Integer R/W
33 Diff Pr 140C Integer R
34 Trip Temp 140E Integer R
35 Warn Temp 1410 Integer R
36 Low Dew Point 1412 Integer R
37 High Dew Point 1414 Integer R
38 Fan Temp 1416 Integer R
RTC Registers
39 Hour 1500 Integer R
40 Minutes 1502 Integer R
41 Seconds 1504 Integer R
42 Date 1506 Integer R
43 Month 1508 Integer R
44 Year 150A Integer R
45 Day 150C Integer R
Status Registers
46 General Status 1600 Integer R
47 Fault Status 1602 Integer R
48 Warn Status 1604 Integer R

Status Register Definition:

Bit Position General Fault Warning


0 Ready HSP DPSE
1 Star Cooler DPOF
2 Run Pressure Probe Failure Dryer Probe Failure
3 Run Load Temperature Probe Low Dew Point
Failure
4 Run Unload Main Motor Overload High Dew Point
5 Stop Busy Reverse Rotation High Differential
pressure
6 Idle Trip Temperature Warn Temperature
7 Emergency Stop Sump Pressure Not Low Voltage
Developing
8 Start Inhibit Sump Pressure probe -
Failure
9 Start ack wait Power failure -