Standard Features
MODEL SHX-100
SUNKINGS Power provides one-source responsibility for the
kVA 110 generating system and accessories.
Standby
kW 100 The generator set and its components are prototype-tested,
factory- built, and production-tested.
kVA 100
Prime The 50Hz generator set offers a AUS 2012 listing and CE 2015
Power kW 90 listing.
Pf.0.8 Frequency Hz 50 The generator set complies with ISO 8528-5, Class G3
requirements for transient performance.
Voltage V 400 The generator set accepts rated load in one step.
The 50Hz generator set engine is certified by the Environmental
Rated speed rpm 1500
Protection Agency (EU or MEP) to conform to EU2、EU3
nonroad emissions regulations.(≤560KW)
A one-year limited warranty covers all systems and
components. Two-, five-, and ten-year extended warranties
are also available.
Generator Features
The brushless, rotating-field generator has broad range
reconnect ability.
The pilot-excited, permanent-magnet generator (PMG) provides
superior short-circuit capability
Controllers are available for all applications. See controller
features inside.
The low coolant level shutdown prevents overheating (standard
on radiator models only)
Integral vibration isolation eliminates the need for under-unit
vibration spring isolators
An electronic, isochronous governor delivers precise frequency
SUNKINGS generator sets meet the standards of ISO9001, CE,
regulation.
BS5000, ISO 8528, ISO 3046, IEC 60034, NEMA MG-1.22. Electronic engine controls and a generator microprocessor
controller combine to deliver one of the most advanced
Standard reference Conditions: control systems in today’s generator market.
Standard reference condition 25℃ (77℉ ) air inlet temp, 100m (328ft)
A.S.L 30% relative humidity. Fuel consumption data with diesel fuel
with specific gravity of 0.85 and conforming to BS 2869: 1998, Class
A2.
RATINGS: All three-phase units are rated at 0.8 power factor. Standby ratings: Standby ratings apply to installations served by a reliable utility source. The standby rating
is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046/1, BS 5514,
AS 2789, and DIN 6271. Prime power ratings:Prime power ratings apply to installations where utility power is unavailable or unreliable. At varying load, the number of
generator set operating hours is unlimited. A 10% overload capacity is available for one hour in twelve. Ratings are in accordance with ISO-8528/1, overload power in
accordance with ISO-3046/1, BS 5514, AS 2789, and DIN 6271.For limited running time and base load ratings, consult SUNKINGS. Obtain the technical information bulletin
(TIS-101) on ratings guidelines for the complete ratings definitions. SUNKINGS reserves the right to change the design or specifications without notice and without any
obligation or liability whatsoever.
Weichai engine Model: WP4.1D113E200
Main features:
• Accessory drive
Single Poly Vee belt drive for fan, alternator and water pump, with self-tension idle for
minimum maintenance
• Complete rebuild ability
Cylinder block has multiple rebore capability. Service cylinder sleeves and valve guides
are also available
• Compact size
Easy for installation and ready access for routine maintenance
• Filters
Fleetguard spin-on fuel filter and full-flow lubricating oil filter
• Cold start capability
Minimum ambient temperature for unaided cold start -12℃
Minimum ambient temperature for aided (with coolant heater) cold start -35℃
Engine Specifications
Engine Brand WEICHAI
Engine Model WP4.1D113E200
Cylinder No.& Configuration 4 cylinder Diesel L type
Working Mode Turbocharged,Aftercooled
Bore x Stroke mm 105*118
Displacement L 4.089
Compression Ratio 17.5:1
Standby Power kW 113
Rated Speed 1500
Lubrication System Splash Lubrication
Lube Oil Conforms above CF class or
SAE10W-30,15w-40
Lube Oil Capacity L 14
Battery Capacity 6-QW-45(380)*2
Fuel Type Diesel:0#(Summer),-
10#(Winter),-35#(Cold)
Fuel Consumption 25% load L/H 6.1
Fuel Consumption 50% load L/H 10.1
Fuel Consumption 75% load L/H 14.1
Fuel Consumption 100% load L/H 18.8
Alternator
NEMA MG1, IEEE, and ANSI standards compliance
Type 4-Pole, Rotating-Field
for temperature rise and motor starting.
Exciter type Brushless, Permanent-Magnet,
Sustained short-circuit current of up to 300% of the
Pilot Exciter
rated current for up to 10 seconds.
Voltage regulator Solid-State, Volts/Hz
Sustained short-circuit current enabling downstream
Insulation NEMA MG1, Class H circuit breakers to trip without collapsing the
Material Synthetic, No hygroscopic generator field.
Temperature rise 130℃, 150℃ Standby Self-ventilated and dripproof construction.
Superior voltage waveform from two-thirds pitch
Bearing: quantity, type 1, Sealed
windings and skewed stator.
Coupling Flexible Disc Digital solid-state.volts-per-hertz voltage regulator
Amortisseur windings Full with±0.25% no-load to full-load regulation.
Rotor balancing 125% 60 Hz, 150% 50 Hz Brushless alternator with brushless pilot exciter for
Voltage regulation, no-load to excellent load response.
full-load(with < 0.5% drift due 3-Phase Sensing, ±0.25%
to temp. variation
One-step load acceptance 100% of Rating Unbalanced
load capability 100% of Rated Standby
Controller
Audiovisual annunciation with NFPA 110 Level 1 capability.
Programmable microprocessor logic and digital display
features. Safeguard circuit protection standard.
12- or 24-volt engine electrical system capability.
Remote start, remote annunciation, and remote
communication options. Refer to M6-46 for additional
controller features and accessories
Key Features ➢ Manual speed control
4-line back-lit LCD text display ➢ Manual fuel pump control
Five key menu navigation ➢ Engine exerciser
Front panel editing with PIN protection ➢ “protections disabled” feature
LED and LCD alarm indication ➢ kW overload protection
Customizable status screens ➢ Power monitoring
Power save mode ➢ Load switching (load shedding and dummy load
Support for up to three remote display units outputs)
9 configurable inputs ➢ Automatic load transfer
8 configurable outputs ➢ Unbalanced load protection
Flexible sender inputs ➢ Independent Earth Fault trip
Configurable timers and alarms ➢ USB connectivity
3 configurable maintenance alarms ➢ Backed up real time clock
Multiple date and time scheduler ➢ Configurable display languages
Configurable event log (250) ➢ User selectable RS232 and RS485 communications
Control logic facilities ➢ SMS Messaging (additional external modem required)
Easy access diagnostic page ➢ Additional display screens to help with modem
CAN and Magnetic Pick-up / Alt. Sensing diagnostics
Fuel usage monitor and low fuel alarms ➢ Integral PLC editor
Charger alternator failure alarm
Generating Sets Standard and Optional Features
Engine
Overview Dimension & Weight
➢ 4-stroke, water-cooled diesel engine
➢ Standard air filter
Ø Standard fuel filter
Ø Standard oil filter
➢ Oil temperature sensor
➢ Low coolant level sensor
Ø Radiator with blowing fan
Ø Industrial silence
➢ Fuel water separator
➢ Water jacket heater (optional)
Alternator
SHX-100(Silent type)
➢ Class H insulation Fuel Tank
Configuration L=Length(mm) W=Width(mm) H=Height(mm) Weight(kg)
➢ IP23 Protection Capacity(L)
➢ Automatic Voltage Regulator (AVR) Silent Type 2900 1100 1750 1600 /
➢ PMG excitation
➢ Single bearing alternator
➢
➢ Class F or class B temperature rise (optional)
➢ Digital Voltage Regulator (optional)
➢ Double bearing (optional)
➢ Condensed heater (optional)
➢ IP41 Protection (optional)
Electrical system
➢ Maintenance-free and anti-explosion battery
➢ Standard breaker
➢ ABB breaker (optional)
➢ ATS (optional)
➢ Battery charger (optional)
➢ GMS monitoring (optional)
Packing
➢ Engine manual
➢ Alternator manual
➢ Gensets operation and maintenance manual SHX-100(Open type)
➢ Tool kit Fuel Tank
Configuration L=Length(mm) W=Width(mm) H=Height(mm) Weight(kg)
Capacity(L)
Open Type 2100 800 1500 1200 /
Baseframe
➢ Forklift pockets
➢ Pulling slots
➢ Earth wire protection
➢ Built-in anti vibration mountings
➢ Fuel outlet value
➢ Standard fuel tank
➢ Enlarged fuel tank (optional)
➢ Separated fuel tank (optional)
Canopy Contact your distributor / dealer for more information
➢ Weatherproof & sound-attenated canopy GUANGDONG SUNKINGS ELECTRIC CO.,Ltd
➢ Sound-absorbing material No.1, Xinglong Road II, Guanglong Industrial
➢ Lifting lug Zone,Chencun Town.
➢ Emergency stop button Shunde District, Foshan City. China.
Web:www.sunkings.cn
➢ Inside silencer
Email: mona@sunkings.cn