Stair Parking: Chamber Dimension: 3 X (50 X 50 X 50)
Stair Parking: Chamber Dimension: 3 X (50 X 50 X 50)
POOL PUMP, EX HAYWARD SUPER PUMP (SIZE REFER TO DRAWING) PARKING STAIR UP
FFL - 0.80 PVC AW Ø 2"
SAND FILTER, EX HAYWARD SAND FILTER (ACCORDING TO POOL PUMP) 1 2 3 4 5
FFL - 0.65
FFL - 0.50
FFL - 0.65
FFL - 0.70
FFL - 0.70
FFL - 0.70
FFL - 0.70
6
100 CM
Chamber 8
FFL - 0.80
BV Ø 2"
Dimension : 3 X (50 X 50 X 50)
BV Ø 2"
UPPER DRAIN 2" GARDEN
INSTALL ON THE POND'S TOPING FFL ± 0.00
POND PUMP
LOWER DRAIN 2"
Capacity : 0.5 HP
INSTALL ON THE POND'S FLOOR
Power : 313.5 Watt
MBC Group XXX plugged into the WPO above the chamber. PVC AW Ø 2"
CORRIDOR
FFL ± 0.00
4
KITCHEN 3
FFL ± 0.00 DINING
FFL ± 0.00 2
1
SUNKEN
FFL - 0.60
4 Ø 1 1/2" Ø 1 1/2"
Ø 2"
GARDEN 3 UPPER POOL
FFL - 0.80 2 FFL - 0.60 BALANCING TANK 1
PVC AW Ø 1 1/2" PVC AW Ø 1 1/2" BATHROOM
1
PVC AW Ø 2" BT dimensionFFL
: 150
± 0.00cm x 150 cm x 200 cm
4 X PVC AW Ø 2" 4 X PVC AW Ø 2"
TERRACE TERRACE For the depth, BT start from pool's gutter FFL.
FFL ± 0.00 FFL - 0.70 GARDEN
5 4 3 2 1
FFL - 0.90 Sump Pit dimension : 30 cm FFLx- 0.80
30 cm x 50 cm
PVC AW Ø 1 1/2" PVC AW Ø 1 1/2" PVC AW Ø 1 1/2" Manhole dimension : 70 cm x 70 cm, with iron plat door
Ø 1 1/2" Ø 1 1/2" Ø 2" Ø 1 1/2"
Ø 1 1/2"
WM Ø 2"
WM Ø 2"
Ø 2"
WM Ø 2"
Ø 2"
GARDEN
HEADER Ø 3"
HEADER Ø 3"
FFL - 0.80
BV Ø 2"
BV Ø 2"
BV Ø 2"
BV Ø 2"
BV Ø 2"
BV Ø 2"
BV Ø 2"
BV Ø 2"
BV Ø 2"
BV Ø 2"
BV Ø 2"
BV Ø 2"
6 X PVC AW Ø 2" 7 X PVC AW Ø 2"
PUMP ROOM
PR dimension : 250 cm x 150 cm x 200 cm
Sump Pit dimension : 30 cm x 30 cm x 50 cm
9 X PVC AW Ø 2" Manhole dimension : 120 cm x 120 cm, with iron plat door
NOTES : GROUND TANK
1 Pool Waste Water (Dark Yellow) uses PVC AW Ø 4" pipe and has -1% slope from the Overflow Drain (OD) to Balancing Tank (BT). GT dimension : 150 cm x 150 cm x 200 cm
2 Pool Waste Water (Dark Yellow) uses PVC AW Ø 2" pipe from the Main Drain (MD) and the Vacuum Fitting (VF) to the Pump Room (PR). Sump Pit dimension : 30 cm x 30 cm x 50 cm
3 Pool Clean Water (Blue) uses PVC AW Ø 2" pipe for the main line. Manhole dimension : 70 cm x 70 cm, with iron plat door
4 The branching pipe to Wall Inlet (WI) and Floor Inlet (FI) use PVC AW Ø 1 1/2" pipe.
5 The height of the sparing pipe for the pool's accessories has been adjusted in the detail drawing.
6 If the subcontractor encounters problems in the project, the subcontractor is obligated to coordinate with the civil supervisor, MEP supervisor and also to the project manager.