CR MULTIFORMAT READER
CAWO DIGID 3.4
DIGITIZER
Affordable and efficient computed radiography
solution offering high image quality and high speed
The tabletop CAWO DIGID 3.4 digitizer is based on proven
Agfa technology, with a modular yet robust with a modular
yet robust design combining affordability with high image
quality, adjustable speed and a user-tuned workflow.
Versatile, this computed radiography (CR) digitizer
can handle a broad range of digital radiography
applications
HIIGHLY VERSATILE AND COMPACT COMPUTED
RADIOGRAPHY SOLUTION OFFERING HIGH The total cost of ownership remains low, thanks to its ease
IMAGE QUALITY AND HIGH SPEED. THE of installation, maintenance and use, making it an affordable
AFFORDABLE, COMPACT AND FAST DIGID 3.4 way to move from analog to digital. With the DIGID 3.4, small
DIGITIZER OFFERS AN IDEAL SOLUTION FOR hospitals and private practices can take advantage of the
DECENTRALISED HOSPITAL EINVIROMENTS, convenient and fast workflow offered by digital radiography.
CLINICS AND PRIVATE PRACTICES.
• Affordable for a broad range of applications Balancing speed and resolution
• Convenient and fast workflow, with user-
With the DIGID 3.4, the user can choose to adjust speed and
controllable speed and resulution
resolution depending on the needs of the exam. The user can
• Robust yet easy to install and maintain
easily overwrite the default settings for each exam, depending
• Fits in small spaces and is suited for mobile
on the specific speed/quality priorities, study by study.
applications
Agfa’s intelligent MUSICA image processing automatically
• Networking capabilities deliver seamless
optimizes image quality.
integration
CAWO Solutions
CR MULTIFORMAT READER
Convenient and fast workflow Horizontal cassette insertion prevents dust and dirt from
being introduced during normal operation.
The DIGID 3.4 works in conjunction with NX, Agfa’s image
identification and quality control tool, for a highly efficient
and optimized radiology workflow.
Fits in small spaces and is suited for mobile
It comes with Agfa’s gold-standard MUSICA software, which With its table-top size, the DIGID 3.4 digitizer can be placed
automatically handles all calibration and image processing, easily at any location, no matter how small, and was designed
independently of body part and dose, optimizing the final with ease of use in mind. The DIGID 3.4 can also be fitted
image quality without the need for any human intervention into cars, vans, trucks and other mobile facilities, for mobile
or special training. applications. Due to the low power consumption, connection
to battery can be easily realized.
Robust yet easy to install and maintain
Networking capabilities deliver seamless
Installing the DIGID 3.4 is fast and easy. With its ‘one
integration
screwdriver’ concept and modular, component-based
design, maintenance is faster, easier and more cost- The DIGID 3.4 is fully DICOM-compliant, to easily integrate
effective, as well. Consequently, set up costs are lower and with other solution elements; combining it with PACS
installation simpler. solution for a complete softcopy solution, or with the
CAWO Dry 2.4 imager for a hardcopy solution.
CASSETTE SIZES
Cassette Sizes Plate Sizes Spatial Resolution
CR MD1.0 GENERAL 35 x 43 cm 35 x 43 cm 10 pixels/mm
(14 x 17 inch) (including for FLFS)
6.6 pixels/mm
5 pixels/mm (including for FLFS)
24 x 30 cm 24 x 30 cm 10 pixels/mm, 6.6 pixels/mm
5 pixels/mm
18 x 24 cm 18 x 24 cm 10 pixels/mm, 6.6 pixels/mm
5 pixels/mm
15 x 30 cm 15 x 30 cm 10 pixels/mm, 6.6 pixels/mm
5 pixels/mm
CR MD1.0F GENERAL 35 x 43 cm 15 x 30 cm 10 pixels/mm, 6.6 pixels/mm
(14 x 17 inch) 5 pixels/mm
CR DD1.0 VET (*) 35 x 43 cm s0, s1, s2, s3, s4, 10 pixels/mm, 6.6 pixels/mm
(14 x 17 inch) equine1 (63 x 180 mm), 5 pixels/mm
equine2 (63 x 210 mm),
equine3 (90 x 220 mm)
15 x 30 cm s0, s1, s2, s3, s4, 10 pixels/mm, 6.6 pixels/mm
equine1 (63 x 180 mm), 5 pixels/mm
equine2 (63 x 210 mm),
equine3 (90 x 220 mm)
(*) for veterinary use only
BAR CODE
In order to guarantee highest image quality, each image plate contains a bar code which contains all
plate specific data.
2
CR MULTIFORMAT READER
technical
SPECIFICATIONS
GENERAL Environmental conditions
• In line with: IEC 721-3-3 (1997): class 3K2, with the
Digitizer type following extension:
• Single cassette feed • Temperature: 15 - 35° C
• Throughput: Up to 102 plates/hour
(depending on size and resolution) Environmental effects
• Noise level: max. 65 dB (A)
Display • Heat dissipation: standby 30 W, max. 140 W
• LED Status Indicator
• Status and error messages on external PC monitor Mobile use
• In line with IEC721-3-3 (1997): 3K2 with the
Greyscale resolution following restrictions:
• Data acquisition: 20 bits/pixel • Temperature: +15° C to +35° C
• Output to processor: 16 bits/pixel square root • Humidity: 15 - 75 % RH (non-condensing)
• During transport with mobile kit: in line with
compressed
IEC721-3-5: 5K1 and 5M3
Dimensions and weight Transport
• W x D x H: 580 x 700 x 471 mm • In line with: IEC 721-3-2 (1997): class 2K2, with the
• Depth without cassette unit and following restrictions: -25 to +55° C (-4 to 131° F)
extension: 380 mm
• Weight: 29 kg Storage
• Packed device shall withstand the following
Power mechanical conditions: IEC 721-3-1: class 1M2
• Autoranging external power supply (24 V output) and IEC 721-3-2(1993): class 2M3; including sea
• Input: transport
• 100 V - 240 V • In line with IEC721-3-1: class 1K4
• <2A
• 50/60 Hz SAFETY
• Fuse: Europe max 16 A; USA max 15 A
Approvals
Minimum requirements • CE, cNRTLus
• CR MD1.0 GENERAL PLATE
• CR MD1.0 GENERAL CASSETTE
• CR MD1.0 CASSETTE ADAPTER 24 X 30
• CR MD1.0F GENERAL PLATE
• CR MD1.0F GENERAL CASSETTE
• CR DD1.0 VET PLATES
• CR DD1.0 VET CASSETTE
• NX
471 mm (18.54 in)
580 mm (22.83 in) 380 mm (14.96 in)
700 mm (27.56 in)
3
CR MULTIFORMAT READER
SAFETY
General
The product has been designed in accordance with the MEDDEV Guidelines relating to the application of Medical Devices
and has been tested as a part of the conformity assessment procedures required by 93/42/EEC Medical Device Directive
(European Council Directive) 93/42/EEC on Medical Devices.
• ISO 13485:2003 Laser Safety
• IEC 62366:2007 • IEC 60825-1:1993
• IEC 60825-1:2007
Safety
• IEC 60601-1:2005 Environmental Compliance
• UL 60601-1:2003 • WEEE 2012/19/EC
• CAN/CSA C22.2 No 601.1-M90 • RoHS 2 Directive 2011/65/EU
Electromagnetic Compatibility
• IEC 60601-1-2-2007
• FCC Rules 47 CRF part 15 subpart B
• CAN/CSA 22.2 No 60601-1-2-08
• IEC 62304:2006
• ISO 14971:2007
Agfa and the Agfa rhombus are trademarks of Agfa-Gevaert NV, Belgium, or its affiliates. CAWO is a © 2018 Agfa NV
trademark of Agfa-Gevaert NV, Belgium, or its affiliates. All rights reserved. All information contained
All rights reserved
herein is intended for guidance purposes only, and characteristics of the products and services described
in this publication can be changed at any time without notice. Products and services may not be available Published by Agfa NV
for your local area. Please contact your local sales representative for availability information. Agfa-Gevaert Septestraat 27 - 2640 Mortsel
NV diligently strives to provide as accurate information as possible, but shall not be responsible for any
Belgium
typographical error.
GB 00201803