Daldoss Manual Door PS Sensor
Daldoss Manual Door PS Sensor
1. AUTOMATIC DOORS
2. AUTOMATIC DOORS SWITCH CONFIGURATION
3. ELECTRONIC PRESSURE SENSOR
1. AUTOMATIC DOORS
Control VVVF
Ctra. Constantí, Km 3 Å Tel. 977 774065 Web site : www.fermator.com
43206 – Reus SPAIN Ê FAX 977 771615 e-mail: [email protected]
Mechanical adjustments.
Outstanding questions.
1
Control VVVF
Φ Τ
Ctra. Constantí km.3 – 43206 Reus SPAIN
Å Tel. +34 977 77 40 65 – Ê Fax. +34 977 77 16 15
The VVVF-3 elevator door operator is a control equipment based on a specific frequency inverter
designed to incorporate the whole functions to control any kind of elevator door.
The system satisfies the most complex operator requirements and offers safety, reliable performance.
With this kind of control the system gets a soft, noiseless, fast and comfortable movement.
The VVVF control is a 3-phase inverter made with the 3rd generation rugged IGBT transistors, fast
speed, that can generate a range frequency from 0.2 Hz to 200 Hz with a 0.1 Hz precision and a 15 KHz
carrier frequency. The carrier frequency guarantees a silent electronic control. The sinusoidal signal
synthesis is made by 3 PWM in real time.
The control is a Frequency/Voltage closed loop positioning type that regulates Voltage and Frequency
independently with a constant torque response in the working frequency range.
The VVVF main processor is from the last generation 16bit microprocessor (Hitachi H8 532). Its high
speed (20 MHz), low power consumption, powerful peripheral devices leads the system to manage in real
time the whole functions with the maximum accuracy.
The working frequency converts the VVVF control to a quiet system.
The electronic components have been distributed on the board for best isolation between the different
areas, to avoid the possibility of a problem in one of them affecting the others. Input control area is
completely isolated by means photo-couplers, the outputs are separated with relays and a driver, the
mains power supplies are isolated and the input power supply is protected against over-voltages (wrong
400V connections) and indirect discharges (surges) up to 2500 V.
The board is a SMD design for a better reliability and an easy assembly.
2
Control VVVF
• Maximum working flexibility. The same control can work with any kind of lift O
1 2 3 4
N
controller in market and with any kind of door operator. It is very easy to
program by means microswitches and there is an automatic auto-adjustment
function to avoid complex parameter programming.
• Automatic Autoadjustment function, to get an easier start up and work for the installer, with
the whole functionality and protections.
• The induction motor is a brushless one so its noiseless performance and reliability is
guaranteed.
• Reduced installation, maintenance and adjustment time.
• Better efficiency than traditional control systems (up to 200% improvement) getting an
important energy saving, less motor heating and a higher working rate (90% rate).
• Accelerations and decelerations are controlled by microprocessor and can be modified.
• Adjustable speeds and safety force regulation:
Opening speed from 0.4 m/second to 1 m/second.
Closing speed from 0.2 m/second to 0.6 m/second.
Safety closing force: 80 N to 150 N.
• Serial communication port with external devices as PC Computers, Bus Interfaces, etc.
• Programming console or PC Interface to customize movement available.
• The control inputs activated by a wide voltage range (from 12V to 230V AC or DC voltage)
or by means free voltage contacts (relay type) to work with any main controller. Multiple
inputs to get a better flexibility, with logic priorities.
55. ENCODER
3
Control VVVF
4. Checking systems.
These are the perfect tools to customize and test easily our electronic boards, specially in
technical departments.
Programming console.
The serial communication interface translates the VVVF serial communication port (a 4-20 mA
safe industrial current loop communication port) to the standard RS-232C levels for a PC
Computer by means a Windows 95/98 based program, to customize the systems and to verify
the system automatically.
4
Control VVVF
The system guarantees the CE European safety and immunity rules and it
have been designed and manufactured in accordance with the following
European harmonized, national and international standards: αβχδε
E198022
This product complies with the Low Voltage Directive 73/23/EEC, the Electromagnetic Compatibility
(EMC) Directive 89/336/EEC and the CE Marking.
Directive 93/68/EEC.
Norm Description
Pr EN81 Generic safety norm for elevators
EN 12015 Electromagnetic compatibility. Product family standard for lift, escalators and
passenger conveyors. Emission.
EN 12016 Electromagnetic compatibility: Product family for lifts, escalators and
passenger conveyors. Immunity. (Generic norms – 4-2/4-3/4-4/4-11)
EN 61000 4 -2 Electrostatic discharges
EN 61000 4 -3 Radiated emissions
EN 61000 4 -4 Electrical fast transient / burst immunity test.
EN 61000 4 -5 Surge immunity test
EN 61000 4 -6 RF immunity
EN 61000 4 - 11 Voltage dips, short interruptions and voltage variations immunity tests.
EN 61000 9 2/3 Harmonic
IEC 664 - 1 Insulation co-ordination for equipment within low-voltage systems:
Principles, requirements and tests.
IEC 60947 4 -1 Electromechanical contactors and motor-starters.
IEC 60947 5 -1 Control circuit devices and switching elements. Electromechanical control
circuit devices.
EN 294 Safety of machinery.
EN60529 Degrees of protection provided by enclosures (IP code).
EN 55011 EMC Generic test norm (Ref. EN 12015).
EN50081-1 EMC Generic emission standard for the residential, commercial and light
industrial environment
EN50081-2 EMC Generic emission standard for the industrial environment
EN50082-2 EMC Generic immunity standard for the industrial environment
Every electronic VVVF board goes through a 24 hours “Burning” process connected at
250 V with two motors to ensure a long working life of each unit.
After the “Burning” there are two more tests done by a computer. One before
assembling the board to the operator, and the other one after assembling it. These two tests
check the correct working of all the functions, acceleration, deceleration, obstruction etc...
When the operator is ready for delivery, the computer print out a label that is added to
the board and it gives information related to the type of door, programming, software and
hardware codes and so on.
All these tests assure us that all the doors produced by Tecnolama are delivered with all the
quality and adjustment tests that are necessary to minimize installation time.
5
Control VVVF
6. NEW FEATURES
Since the beginning we have innovated to bring new features (in the software and the
hardware control) and technologies.
That means a constant evolution and improvement of the managing control system.
This new VVVF control is completely compatible with the previous one and it incorporates a
new microprocessor more powerful, more internal memory and a improved software for a
better movement performance.
The adaptive control for VVVF door operator tries to maintain the brake distances even
in the worst conditions.
The system measures the space just in the final brake points to compensate in next
cycles and it improves the signal to get always the space approximation programmed by
means the programming console.
The compensation application runs through a recursive algorithm that makes
the average from the measures made, integrating the effort of the cabin door and the
different landing doors.
With this function we can compensate the torque losses when the motor is very hot or
the mechanism becomes old.
6
Control VVVF
7. START UP PROTOCOL
Every electronic VVVF board pass through a 24 hours “Burning” process connected at
250 V with two motors to ensure a long working life of each unit.
After the “Burning” there are two tests more done by a computer. One before
assembling the board to the operator, and the other one after assembling it. These two tests
check the correct working of all the functions, acceleration, deceleration, obstruction etc...
When the operator is ready for delivery, the computer print out a label that is added to
the board and it gives information related to the type of door, programming, software and
hardware codes and so on.
All these tests assure us that all the doors produced by Tecnolama are delivered with all the
quality and adjustment tests that are necessary to minimize installation time.
1. - The door must be middle opened to see better the initial movement.
2. - Disconnect the signals coming from the main controller (8,9,10,11,12, and 24,25).
6. - The door must remain stopped. If the door moves check the microswitch 1 in OFF
position.
7
Control VVVF
7. - Press the AUTOADJUSTMENT button (51) to make an autoadjustment cycle.
The door should close, in case it opens you should check the microswitch 3 and if it is
correct then any motor phases is inverted and it will have to interchange 2 of them and
make the autoadjustment again.
- If the door doesn’t move, check the motor wires and the motor connector (56).
- If the door stops before close completely, the information from the encoder is not
correct.
- If the door stops in the locking skate movement check manually the lock and de-lock
skate movement is made easily and completely.
(See the Mounting cabin doors instructions).
- If The door doesn’t close completely disconnect the whole system and check if there is
any mechanical obstruction.
When the door is fully closed it will activate the CLOSE led and after a few seconds
will open slowly and the led will be deactivated.
The door should open slowly until the mechanical rubber stopper.
- If only opens 26 cm, the encoder information doesn’t arrive to the VVVF. Check the
connections or change the encoder or the wire if they are damaged.
- If doesn’t open completely, check the mechanical because the motor torque is enough
to drag any kind of door (Check the wheels, the leaves, etc.)
The door will close again.
If the door doesn’t close, one encoder phase fails. Verify the wire and the encoder.
If the door stops for some seconds before the close movement thereis too much
mechanical friction detected by the system. The system will work, but the door operator
should be checked mechanically.
Some considerations should be taken when the special car lock system is installed.
The last software version will detect this device automatically and special working conditions
will be adopted.
Be sure to switch off the VVVF control when connecting the input signals to do not
make a shortcircuit between the 0-12V internal voltage and the lift control signals with
external voltage.
8
Control VVVF
9
Control VVVF
•The door hits when opens, the “open”LED is not activated and the
system gets out of order.
- Check the tension of the toothed belt, because probably is not correctly adjusted and it slips
on the pulley of the motor and consequently the encoder is sending a wrong information to the
controller.
• The system gets power but doesn’t work and LED ON is off. Ext. Fuse
- Check if the external fuse is burned and change it for another of the same type
(250V , 4A ceramic fast speed).
• The LEDS are working but the door doesn’t move. Int. Fuse
- Check if the internal fuse is burned and in case it is, please send the controller
back to Tecnolama to be repaired, but do not try to change it by yourself as it
could give an electric shock and break the output transistors.
• Disconnect the input signals from the controller, the encoder wires and program the switch 1
in ON position. (Only mains supply and motor connected). Switch on the circuit.
If the door starts to open, then the turning sense is correct, but if the door starts to
close, interchange two motor phases.
• Connect the encoder wire and the system inputs.
How to check the
encoder.
• If the door closes, opens and stops after 26 cm, the encoder is not connected or it is
damaged.
• If the door closes, opens but doesn’t close again, one phase of the encoder is not correct.
Interchange the 2 middle wires only, but never the two wires in the extreme because this
would damage the encoder.
This could happen updating an old VVVF controller type (like the VVVF1).
Pressing the TEST button the door should apply the correct acceleration and deceleration
curves and it means that the motor and the encoder are correct.
10
Control VVVF
- Connecting 220V or any voltage between the 12V (9) or 0V (11) terminals.
- Drops of water inside the controller. If this happens, disconnect the system and dry it
completely.
- To change the fuse number 3 can also damage the output transistors. If this fuse is
burned, proceed to change the whole controller.
- Connecting any signal with power in the SERIAL PORT or ENCODER connectors.
Be careful to switch off the VVVF control when connecting the input
signals to do not make a shortcircuit between the 0-12V internal
voltage and the lift control signals with external voltage.
11
Control VVVF
1.-TO SEE the speeds and the re-opening safety effort programmed.
We connect the console by the “SERIAL PORT” connector.
Pressing the “OPEN” / “CLOSE” keys the screen will show the opening and closing speeds
mm/s.
Pressing the “SAFETY” key we will see the effort of the programmed re-opening in case of
obstruction reflected in a scale from 15 to 22.
2.- TO DETECT
To enter into the new VVVF-4 menu press the ? key and ENTER
It will show VERSION 4004 according to the software electronic board, and it activates
the new extra information related to this version.
Pressing the TEST and ENTER keys the screen will show the first information data:
SUPPLY VOLTAGE
This indicates the rectified tension supply, and it informs if the protection fuse is blown.
Note: Press “+” or “-“ to show up/down the different parameters step by step.
ALARM 00 - Alarm code if an error is detected. The alarm code references are:
1 - Driver 2 - Bl.Open 4 - Bl.Close 8 - Friction 16- Temperature 32- Autoadjust 64- Encoder
DOOR POSITION Door position in centimeters from the closed door position. So, when
000 the door is opened it will show the clear entrance.
(Clear entrance plus 7 pulses if the door has a skate for automatic landing door. For example a
door with a clear opening of 800mm will show 87 pulses with the door opened.)
It is useful to check the encoder performance.
12
Control VVVF
It must be the same as the DIP-switch programmed. If not, there must be a problem with the
component, the socket connection or the control.
From left to right, the information offered is the following for the VVVF-3 control:
INPUTS It shows if the control inputs connected to the VVVF are activated or not.
0100 0000 0 it means not activated (OFF) and 1 activated (ON).
By means this screen we can check if the door operator works correctly with the lift controller.
From left to right, the information offered is the following for the VVVF-3 control:
Close / Open / Re-Open / NC / Encoder / Slow Closing/ Fast Closing / Autoadjustment
SHORTCIR.CYCLES No. times over current protection activated.(Short circuit or motor blocked)
PHOTOCELL FAULT No. times the photocell has been obstructed more than 1 minute.
BLOCKAGE CYCLES No. times the door has been blocked at opening.
The next field are only activated for the VVVF-4 control version:
13
Control VVVF
3.- REPROGRAMMING.
NOTE:
To change the PARAMETERS press ENTER and + and - to change the VALUES.
(In software versions before 3006 it is not possible to save the parameters afterwards).
There are different possibilities it depends on the doors weight, number of motors, mechanical
conditions, skate modifications, etc. The particular conditions leads to vary the standard
program.
For example, you have to increase the space at closing CLOSE LENGTH if the doors hit a bit at
closing, or increase the 0 VOLTAGE and decrease the V/F OPEN Ratio if a very heavy door has
problems to open completely at the final opening movement.
Take always in mind that you have to protect the modified parameters because if
not the auto-adjustment function will fix the standard ones for the type of door.
14
Control VVVF
Max. speed
ing
De
en
c .o
op
pe
el.
11. VVVF PROGRAMMING OPEN
nin
c
Ac
g
Skate space End opening space
OPENED CLOSED
PARAMETERS
Dec
Max. speed
sin
c lo
c
.c lo
e l.
sing
c
CLOSED
Ac
(standard values)
AUTOMATIC SEMIAUTOMATIC
OPEN LENGHT 002 The space at the final opening at slow speed. (in cm)
Increase if the door hits at opening.
CLOSE LENGTH 004 The space at the final closing at slow speed. (in cm)
Increase its value if the door hits at closing.
HOLD TORQUE 045 The voltage applied to the motor to keep the door opened. (V)
Change this value just enough to maintain the door in opened position.
OPEN SKATE SPEED 100 The speed applied to the motor at opening.
(Adjustable up to 200 mm/s)..
LENGTH SKATE 007 The required space to open the skate. (in cm)
Do not modify this value, as long as the required space to open the skate is not mechanically modified.
NO , it means that a new auto adjustment would automatically bring back all the standard parameters
adjusted with the door, losing all the modifications done with the console.
15
Control VVVF
This supplier has been made to use with the FERMATOR battery, or another one with
these specifications: - Voltage = 12 V DC.
- Output Current > 8 A during 10 s. ( min. 11.5 Volts).
With a FERMATOR battery, it is necessary to make from terminals 9(+12V) and 11( 0V)
of the control signals inlet to the charge connection (+46 and – 45).
With an ordinary battery with its own charge system this connection won’t be
necessary.
Connection Diagram:
-+
The equipment is activated by the FLOOR signal control (a free voltage contact). This
signal activates the system at least 15 seconds, and after it goes to a standby situation with a
consumption of 20mA. As you can see it is not necessary to eliminate this signal after the
operation.
16
Control VVVF
Internal connection to charge the battery.
i NOTE: The VVVF assembled with the emergency supplier is delivered with an internal
battery charging wiring. So there is no need of the external wiring (45-46) used in previous
VVVF versions.
i NOTE: The same unit with a little modification is available for 2 motors operators.
The VVVF-4 unit must have the TEC4005 software version or newer.
17
Control VVVF
INVERTER:
Carrier frequency 15 KHz (Noiseless)
Frequency range 0.5…200Hz / 0.1 step
Voltage range 3~ x 40… 200 V /2 V step
Efficiency >95%
Max. output current 4 Amps (fast ceramic fuse protection no.3)
Positional Control Quadrature Encoder, 0.1Hz freq.resolution
Communication Serial Port 1200 Baud, 0-20mA Current Loop
MOTOR:
Asynchron three phase 6 poles
Voltage supply 250V
Power 250W
Thermic Class B – 130ºC
Nominal speed 900RPM
DOOR:
Opening Speed 1 m/s Max.
Closing Speed 0.6 m/s Max. (Limited for safety reason)
Safety Force 8..15 Kg.cm Adjustable
Maximum torque 25 Kg.cm
Maintenance torque (Opened door) 8 Kg.cm
Working Frequency Until 400 cycles/hour
INPUTS:
Optoisolated signals Bi-directional Optocouplers
Impedance 20 KΩ
Voltage or free voltage activation 12…230 V AC or DC
OUTPUTS:
Relay Contacts Switched Normally open free contact
Output Current 1.5 A max.
Voltage 230 V max.
Switched Power capacity 30 W
Switched time response 8 ms
Switched resistance 50 mΩ
WORKING CONDITIONS:
Ambient temperature -10 to +60ºC (with no freezing)
Ambient humidity <95% RH (with no dew condensation)
Storage temperature -20 to +70ºC
18
2. AUTOMATIC DOORS
SWITCH CONFIGURATION
Programmazione porta
Via al Dos de la Roda, 18
Località Cirè 38057
Fermator x Cory
Pergine Valsugana (TN) Italia
Codice Documento: U_D1_020
Revisione: 1
Data: 01.07.2005
SWITCH 1 = OFF
SWITCH 2 = ON
SWITCH 4 = OFF
Certificazione Pagina:
UNI-EN ISO 9001
N. 9102 DALD 1/1
3. ELECTRONIC
PRESSURE SENSOR
ELECTRONIC PRESSURE SENSOR (EASYLIFE INSTALLATIONS)
The electronic pressure sensor PP7022 permits the detection and monitoring of the pressure in a hydraulic system,
giving a switching signal according to the different type of functioning modus once the overload level has been
reached. The reduced dimensions as well as the use of only 4 controller interface wires, make this device particular-
ly suitable for lift applications.
The sensor body has a cylindric shape and is built in stainless steel. At one end there is the connector (male 4 ways)
for the controller connection. On the other end there is a thread (M12x1) which allows the fixing of the device to
the valve block of the pump unit.
Typical pressure values range of the sensor is from 0 to 100bar/10MPa/1450PSI. The maximum pressure tolerable
is 300bar/30MPa/4351PSI; the bursting pressure is over the 650bar/65MPa/9425PSI.
Operating voltage must be within a min. of 9,6V d.c. to a max. of 30V d.c.
The device has a short-circuit and reverse polarity protection (on power supply), overload protection for the outputs
(250mA max).
ATTENTION
Make sure that no pressure is applied to the system before mounting or removing the sensor. Screw the sensor into
a G1/4 process connection. Tightening torque recommended 25Nm (max 50Nm).
In order to avoid air bubbles on the sensor transductor, insert some oil into it (hole positioned at the end of the
threacked connection which is connected to the valve block).
Legend
Sensor pin-out
pin 1 BN, brown power supply (positive)
pin 2 WH, green teach input IN (default) or switching output OU2 *
pin 3 BU, yellow power supply (negative)
pin 4 BK, white switching output OU1 (default) or communication interface *
T = programming signal
* The functions of the connector pins 2 and 4 are selectable in according to the application (see paragraph “Menu
command”- sez. OU1 and OU2, page 22 of operating instructions manual); any action is necessary in our instal-
lations, because default values are in use.
Functions
Programming
Be sure that the sensor is correctly applied to the valve block of the pump unit and connect the power supply cables
(positive “2” and negative “1” signals) to his pin1 and pin 3, as showed in the control panel drawing. The switching
output OU1 (pin 4) will be only connected when the programming process will be finished.
Switch on the power supply and verify that the green led of the sensor is turned on.
Applying on the teach input (pin2, IN) a positive or negative signal (see “T” button on electrical drawing above),
it is possible to configure following parameter:
- overload threshold
!!! When the programming process is finished the teach input IN (pin2) must be disconnected
ATTENTION
The pressure sensor uses factory default values as follows:
overload threshold = not defined
switching output OU1 = normally open
switching output OU1 logic = NPN