ML180UH
MERIT® SERIES
Upflow / Horizontal
Bulletin No. 210590
P R O D U C T S P E C I F I C AT I O N S April 2019
Supersedes October 2018
AFUE - 80%
Input - 44,000 to 132,000 Btuh
Nominal Add-on Cooling - 2 to 5 Tons
MODEL NUMBER IDENTIFICATION
ML 1 80 UH 070 X P 36 B
Unit Type 1
Cabinet Width
ML = Merit Series® A = 14-1/2 in.
B = 17-1/2 in.
Stages C = 21 in.
1 = Single-Stage D = 24-1/2 in.
1
Indoor coils with the same letter designation will physically match the furnace.
FEATURES
CONTENTS
Blower Data................................................................ 15 J
Dimensions - Furnace/Coil Combined Dimensions.... 14
Dimensions - Horizontal Position................................ 12
Dimensions - Optional Accessories............................ 13
Dimensions - Upflow Position..................................... 11 B
Features....................................................................... 2
Gas Heat Accessories ................................................. 9 F
High Altitude Derate...................................................... 9 L
Installation Clearances............................................... 10
D
G E
Model Number Identification......................................... 1
Optional Accessories - Order Separately..................... 9 C
Specifications............................................................... 8
K
NOTE - ML180UH FURNACES ARE NOT
AVAILABLE IN CANADA! I
WARRANTY
ML180UH / Page 2
FEATURES
HEATING SYSTEM G Flame Rollout Switches (2)
Manual reset switches are factory installed on the front
B Lennox Duralok™ Heat Exchanger Assembly of the burner box.
Heavy gauge aluminized steel heat exchanger.
Crimped seam clamshell type design. Switches provides protection from abnormal operating
conditions.
Designed for normal expansion and contraction.
Minimum resistance to Limit Control
air flow. Automatic reset, primary limit is accurately located on
vestibule panel on all units.
Heat exchanger has
been laboratory life Optional Accessories
cycle tested in excess of
industry standards. High Altitude Pressure Switch Kit
Required on most units for proper unit operation at
Compact size of heat
altitudes from 4,501 to 7500 ft.
exchanger permits low
overall design of furnace Natural Gas to LPG/Propane Conversion Kit
cabinet. Required for field changeover from natural gas to LPG/
Propane.
C Inshot Burners
Aluminized steel inshot burners provide efficient, LPG/Propane to Natural Gas Conversion Kit
trouble-free operation. Required for field changeover from LPG/Propane to
Burner venturi mixes air and gas in correct proportion natural gas.
for proper combustion.
Vent Adaptor (Upflow Applications Only)
Burner assembly is removable from the unit as a single Allows venting through a 6 in.
component for ease of service. masonry chimney without the (152 mm)
need of a flue liner.
D SureLight® Hot Surface Ignitor
Tough, reliable, long-life, trouble-free performance. Manual reset temperature
Silicon nitride ignitor. sensor protects against 7 in.
(178 mm)
abnormal operating conditions.
Cemented to steatite block for protection against current
leakage. Sensor wiring may be routed
from either side of adaptor.
Ignition leads are constructed of nickel plated copper
and are enclosed in high temperature Teflon® insulation Minimum winter design
for dependable operation. temperatures:
−10°F when used with interior masonry chimneys.
E Gas Control Valve +5°F when used with exterior masonry chimneys.
24 volt redundant combination gas control valve
combines manual shut off switch (On-Off), automatic Refer to Winter Design Temperatures Map on page
electric valve (dual) and gas pressure regulation into a 7 for application information. Also refer to the
compact combination control. installation instructions for detailed information.
BLOWER
F Combustion Air Inducer
Shaded pole heavy duty blower prepurges heat H Multi-speed direct drive blower.
exchanger and safely vents flue products. Statically and dynamically balanced.
Pressure switch proves blower operation before Resiliently mounted.
allowing gas valve to open. Blower assembly easily removed for servicing.
Operates only during heating cycle. Blower speeds are easily changed on the integrated
Direct access allows inducer assembly to be rotated furnace control. See blower performance tables.
90° clockwise or counterclockwise to facilitate easy vent
attachment in horizontal applications.
ML180UH / Page 3
FEATURES
ML180UH / Page 4
FEATURES
CONTROLS (continued) CABINET
Optional Accessories (continued) Low-profile, narrow width cabinet allows easy
installation.
Thermostat Heavy-gauge, cold rolled steel construction.
Thermostat (programmable/non-programmable) is not
Pre-painted cabinet finish.
furnished with unit.
Flue outlet on top of cabinet for upflow applications,
See Thermostat bulletins in Controls Section and
can be relocated to either side of cabinet for horizontal
Lennox Price Book for selection.
applications.
Night Service Kit Flanges provided on supply air opening for ease of
Contains most commonly used service parts: plenum connection or alignment with indoor coil.
• Furnace Control J Insulated cabinet with foil faced insulation on sides and
• Ignitor back of heating compartment.
• Flame sensor Complete service access.
• Gas valve K Safety interlock switch automatically shuts off power
• Transformer to unit when blower compartment access panel is
removed.
Air Filter and Rack Kit for Horizontal Return Air L Gas piping and electrical inlets are provided in both
(End) Applications sides of cabinet.
Washable or vacuum cleanable polyurethane frame
type filter and external end return air rack available for Return Air Entry:
field installation. For bottom/end return-air entry for upflow/horizontal
Rack has filter door for easy filter servicing. applications, remove furnished bottom seal panel from
cabinet.
Flanges on rack allow easy duct connection.
For side return-air entry (upflow applications only),
See dimension drawing. corners are marked on either side of cabinet for return
Air Filter and Rack Kit for Upflow Side Return Air air cut-outs.
Applications - Not for use with Return Air Base See dimension drawings.
Washable or vacuum cleanable polyurethane frame NOTE - 60C and 60D size units that require air
type filter and external side return air rack available for volumes over 1800 cfm must have one of the
field installation. following:
Available in single and ten pack kits. 1. S ingle side return air and Optional Return Air
Rack has filter door for easy filter servicing. Base with transition that must accommodate
Flanges on rack allow easy duct connection. required 20 x 25 x 1 inch air filter to maintain
proper velocity.
Field installs on either side of unit cabinet. See
dimension drawing. 2. Bottom return air.
3. Return air from both sides.
4. Bottom and one side return air.
See Blower Performance Tables for additional
information.
Coil Match-Up
All furnaces exactly match Lennox cased upflow
indoor coils and horizontal indoor coils with same letter
designation (A, B, C, D) in model number. No adaptor
required. Engaging holes furnished on cabinet for
alignment.
Lennox uncased coils match furnaces without any
overhang but require an optional adaptor base or field
fabricated transition to match furnace opening. See coil
bulletin for additional information.
ML180UH / Page 5
FEATURES
CABINET (continued) FILTER (not furnished)
Optional Accessories Filter and provisions for external mounting must be field
provided.
Horizontal Suspension Kit
Optional Accessories
Provides suspension of unit and indoor coil in horizontal
applications. Air Filter and Rack Kit for Horizontal Return Air
Allows complete service access. (End) Applications
Consists of corner mounted hanging brackets with Washable or vacuum cleanable polyurethane frame
vibration isolators, return air end support rail and type filter and external end return air rack available for
hardware for assembly. field installation.
Metal hanging straps must be field provided. Rack has filter door for easy filter servicing.
Flanges on rack allow easy duct connection.
Return Air Base
See dimension drawing.
A field fabricated transition or Return Air Base is
required when using an IAQ product higher than 14- Air Filter and Rack Kit for Upflow Side Return Air
3/16 in. installed next to the unit and serviced from the Applications - Not for use with Return Air Base
front. IAQ products higher than 20 in. require a field
Washable or vacuum cleanable polyurethane frame
fabricated transition.
type filter and external side return air rack available for
Base must be used for 60C and 60D models with air field installation.
volumes over 1800 cfm in upflow applications when
Available in single and ten pack kits.
only one side return is required.
Rack has filter door for easy filter servicing.
Cabinet is shipped flat for easy field assembly and is
pre-painted steel to match the furnace. Flanges on rack allow easy duct connection.
See Dimension Drawing. Field installs on either side of unit cabinet. See
dimension drawing.
High Performance Economizer
(Commercial Applications Only)
Designed for applications requiring outdoor air to be
utilized in a commercial HVAC system. Allows the
entry of fresh outdoor air for free cooling, reducing the
requirement for mechanical cooling.
Heavy gauge galvanized steel cabinet lined with thick
fiberglass insulation.
Mixed air sensor, outdoor air sensor and 24VAC
transformer furnished.
Approved for California Title 24 building standards.
ASHRAE 90.1-2010 compliant.
See separate Product Specifications bulletin for
additional information and available control and sensor
options.
ML180UH / Page 6
99% WINTER DESIGN TEMPERATURES FOR THE CONTIGUOUS UNITED STATES
5 oF −10oF
17oF
−10oF
27 F
o
5 oF
−10oF
37 F o
17oF
27oF
37oF
This map is a necessarily generalized guide to temperatures in the contiguous Unites States. Temperatures shown for
areas such as mountainous regions and large urban centers may not be accurate. The data used to develop this map
was taken from the 1993 ASHRAE Fundamentals Handbook (Chapter 24, Table 1: Climate Conditions for the United
States).
Reprinted with permission from NFPA 54: National Fuel Gas Code 1999, National Fire Protection Association, Quincy,
MA 02269. This reprinted material is not the complete and official position of the National Fire Protection Association on
the referenced subject, which is represented only by the standard in its entirety.
ML180UH / Page 7
SPECIFICATIONS
Gas Model No. ML180UH045P24A ML180UH045P36A ML180UH070P24A ML180UH070P36A
Heating Model No. - Low Nox --- ML180UH045XP36A --- ML180UH070XP36A
Performance AHRI Ref. No. Non “X” Models 4208204 4208205 4208206 4208207
“X” Models --- 4208213 --- 4208214
1
AFUE 80% 80% 80% 80%
Input - Btuh 44,000 44,000 66,000 66,000
Output - Btuh 35,000 35,000 54,000 54,000
Temperature rise range - °F 20 - 50 15 - 45 30 - 60 30 - 60
Gas Manifold Pressure (in. w.g.) 3.5 / 10.0 3.5 / 10.0 3.5 / 10.0 3.5 / 10.0
Nat. Gas / LPG/Propane
High Static - in. w.g. 0.50 0.50 0.50 0.50
Connections Flue connection - in. round 4 4 4 4
in. Gas pipe size IPS 1/2 1/2 1/2 1/2
Indoor Wheel nom. dia. x width - in. 10 x 7 10 x 8 10 x 7 10 x 8
Blower Motor output - hp 1/5 1/3 1/5 1/3
Tons of add-on cooling 1.5 - 2 2-3 1.5 - 2 2-3
Air Volume Range - cfm 345 - 1130 650 - 1670 420 - 1160 785 - 1660
Electrical Voltage 120 volts - 60 hertz - 1 phase
Data Blower motor full load amps 3.1 6.1 3.1 6.1
Maximum overcurrent protection 15 15 15 15
Shipping Data lbs. - 1 package 105 110 114 119
SPECIFICATIONS
Gas Model No. ML180UH090P36B ML180UH090P48B ML180UH110P48C
Heating Model No. - Low Nox --- ML180UH090XP48B ---
Performance AHRI Ref. No. Non “X” Models 4208208 4208209 4208210
“X” Models --- 4208215 ---
1
AFUE 80% 80% 80%
Input - Btuh 88,000 88,000 110,000
Output - Btuh 71,000 71,000 89,000
Temperature rise range - °F 25 - 55 25 - 55 25 - 55
Gas Manifold Pressure (in. w.g.) 3.5 / 10.0 3.5 / 10.0 3.5 / 10.0
Nat. Gas / LPG/Propane
High Static - in. w.g. 0.50 0.50 0.50
Connections Flue connection - in. round 4 4 4
in. Gas pipe size IPS 1/2 1/2 1/2
Indoor Wheel nom. dia. x width - in. 10 x 9 10 x 10 10 x 10
Blower Motor output - hp 1/3 1/2 1/2
Tons of add-on cooling 2-3 3-4 3-4
Air Volume Range - cfm 680 - 1795 920 - 2160 910 - 2170
Electrical Voltage 120 volts - 60 hertz - 1 phase
Data Blower motor full load amps 6.1 8.2 8.2
Maximum overcurrent protection 15 15 15
Shipping Data lbs. - 1 package 131 138 151
SPECIFICATIONS
Gas Model No. ML180UH110P60C ML180UH135P60D
Heating Model No. - Low Nox ML180UH110XP60C ---
Performance AHRI Ref. No. Non “X” Models 4208211 4208212
“X” Models 4208216 ---
1
AFUE 80% 80%
Input - Btuh 110,000 132,000
Output - Btuh 89,000 107,000
Temperature rise range - °F 25 - 55 30 - 60
Gas Manifold Pressure (in. w.g.) 3.5 / 10.0 3.5 / 10.0
Nat. Gas / LPG/Propane
High Static - in. w.g. 0.50 0.50
Connections Flue connection - in. round 4 4
in. Gas pipe size IPS 1/2 1/2
Indoor Wheel nom. dia. x width - in. 11-1/2 x 10 11 x 11
Blower Motor output - hp 1 1
Tons of add-on cooling 4-5 4-5
Air Volume Range - cfm 1355 - 2715 1380 - 2810
Electrical Voltage 120 volts - 60 hertz - 1 phase
Data Blower motor full load amps 10 11.5
Maximum overcurrent protection 15 15
Shipping Data lbs. - 1 package 161 174
NOTE - Filters and provisions for mounting are not furnished and must be field provided.
1
Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces.
ML180UH / Page 8
OPTIONAL ACCESSORIES - ORDER SEPARATELY
“A” Width “B” Width “C” Width “D” Width
Models Models Models Models
CABINET ACCESSORIES
Horizontal Suspension Kit - Horizontal only 51W10 51W10 51W10 51W10
Return Air Base - Upflow only 65W75 50W98 50W99 51W00
High Performance Economizer (Commercial Only) 10U53 10U53 10U53 10U53
Controls
iComfort® M30 Smart Wi-Fi Thermostat 15Z69 15Z69 15Z69 15Z69
Remote Outdoor Air Temperature Sensor X2658 X2658 X2658 X2658
FILTERS
1
Air Filter and Rack Kit Horizontal (end) 87L95 87L96 87L97 87L98
Size of filter - in. 14 x 25 x 1 18 x 25 x 1 20 x 25 x 1 25 x 25 x 1
Side Return Single 44J22 44J22 44J22 44J22
Ten Pack 66K63 66K63 66K63 66K63
Size of filter - in. 16 x 25 x 1 16 x 25 x 1 16 x 25 x 1 16 x 25 x 1
NIGHT SERVICE KITS
Night Service Kit 68W80 68W80 68W80 68W80
VENTING
Vent Adaptor − 6 in. conn. size upflow applications only 18M79 18M79 18M79 18M79
1
Cleanable polyurethane, frame-type filter.
0 - 2000 Feet 2001 - 4500 Feet 4501 - 7500 Feet 7501 - 10,000 ft. Minimum
Input
Maximum
Natural LPG/ Natural LPG/ Natural LPG/ 1
Natural LPG/ Natural LPG/
Gas Propane Gas Propane Gas Propane Gas Propane Gas Propane
045 3.5 10 3.2 10 3 10 3.5 10 4.5 11 13
070 3.5 10 3.2 10 2.8 10 3.5 10 4.5 11 13
090 3.5 10 3.2 10 2.7 9.6 3.5 10 4.5 11 13
110 3.5 10 3.5 10 3 9.6 3.5 10 4.5 11 13
135 3.5 10 3.5 10 2.9 9.6 3.5 10 4.5 11 13
1
Natural Gas High Altitude Orifice Kit required.
ML180UH / Page 9
INSTALLATION CLEARANCES
UPFLOW POSITION HORIZONTAL POSITION
Vent Type Type B1 Type C Vent Type Type B1 Type C
Sides 0 (0) 1
0 (0) End 1
2 1
2
Rear 0 (0) 0 (0) Rear 0 (0) 0 (0)
Top 1 (25) 1 (25) Top 1
0 (0) 1
0 (0)
Front 2-1/4 (57) 2-1/4 (57) Front 2-1/4 (57) 2-1/4 (57)
Front (service/alcove) 24 (610) 24 (610) Front (service) 24 (610) 24 (610)
Floor Combustible Combustible Floor Combustible Combustible
Flue 1 (25) 6 (152) Flue 1 (25) 6 (152)
NOTE − Air for combustion must conform to the methods outlined in the National NOTE − Air for combustion must conform to the methods outlined in the National
Fuel Gas Code (NFPA 54/ANSI-Z223.1). Fuel Gas Code (NFPA 54/ANSI-Z223.1).
NOTE − In the U.S. flue sizing must conform to the methods outlined in the NOTE − In the U.S. flue sizing must conform to the methods outlined in the
current National Fuel Gas Code (NFPA 54/ANSI-Z223.1) or applicable current National Fuel Gas Code (NFPA 54/ANSI-Z223.1) or applicable
provisions of local building codes. provisions of local building codes.
1
Left side requires 4 in. if single wall vent is used on 14-1/2 in. cabinets, 2 in. on 1
Line contact installation permissible between jacket top or sides and building
17-1/2 in. cabinets. joists.
ML180UH / Page 10
DIMENSIONS - UPFLOW POSITION
3-1/8 (79)
1 NOTE - 60C and 60D size units that require air volumes over
1800 cfm must have one of the following:
1. Single side return air and Optional Return Air Base
with transition that must accommodate required D
20 x 25 x 1 inch (508 x 635 x 25 mm) air filter to
maintain proper velocity.
2. Bottom return air. SUPPLY AIR
3. Return air from both sides. OPENING
4. Bottom and one side return air. FLUE OUTLET
See Blower Performance Tables for additional information. (Top)
2 FLUE OUTLET
(Either Side)
9-1/8 (232) Right
3 OPTIONAL ELECTRICAL INLET
8-5/8 (219) Left
EXTERNAL (Either Side)
SIDE RETURN
AIR FILTER KIT
(Either Side)
33 5-3/8 (137) Right GAS PIPING INLET
(838) 2-3/16 (56) Left (Either Side)
ELECTRICAL
23 1-1/2
INLET (Either Side) (584) (38)
14-3/4
(375)
1 SideReturn 14
16 Air Opening (356)
(406) (Either Side)
1-15/16 (49)
5/8
3/4 3/4 (16) 3-1/4 23-1/2
(19) C (19) (83) (597)
1 BottomReturn 1 Bottom Return
Air Opening Air Opening
A B C D
Model No.
in. mm in. mm in. mm in. mm
ML180UH045P24A
ML180UH045P36A
14-1/2 368 13-3/8 340 13 330 4-3/4 121
ML180UH070P24A
ML180UH070P36A
ML180UH090P36B
17-1/2 446 16-3/8 416 16 406 6-1/4 159
ML180UH090P48B
ML180UH110P48C
21 533 19-7/8 504 19-1/2 495 8 203
ML180UH110P60C
ML180UH135P60D 24-1/2 622 23-3/8 594 23 584 9-3/4 248
ML180UH / Page 11
DIMENSIONS - HORIZONTAL POSITION
LEFT-HAND AIR DISCHARGE
1 Flueoutlet may be from end but
furnace must be vented vertically
GAS PIPING INLET
(Top or Bottom)
9-1/8 (232) Top AIR
8-5/8 (219) Bottom FLOW
ELECTRICAL INLET
(Top or Bottom)
FLUE OUTLET
(Top)
3/4 (19)
3 (76) Front Panel
3/4 (19)
Front Panel 3 (76)
2-3/16 (56) Top
5-3/8 (137) Bottom 8-5/8 (219) Top
9-1/8 (232) Bottom
TOP VIEW
27-3/4 33 1 FLUE OUTLET 27-3/4
(705) (838) (End) 3-1/8 (705)
(79)
3/4 9/16
END VIEW (19) FRONT VIEW END VIEW (14)
A B C D
Model No.
in. mm in. mm in. mm in. mm
ML180UH045P24A
ML180UH045P36A
14-1/2 368 13-3/8 340 13 330 4-3/4 121
ML180UH070P24A
ML180UH070P36A
ML180UH090P36B
17-1/2 446 16-3/8 416 16 406 6-1/4 159
ML180UH090P48B
ML180UH110P48C
21 533 19-7/8 504 19-1/2 495 8 203
ML180UH110P60C
ML180UH135P60D 24-1/2 622 23-3/8 594 23 584 9-3/4 248
ML180UH / Page 12
DIMENSIONS - OPTIONAL ACCESSORIES
5/8 Furnace A B
Catalog
(16) Cabinet
Number in. mm in. mm
Width
AIR FILTER
5/8 (Furnished)
(16)
SIDE VIEW FRONT VIEW
FURNACE
FRONT
IF BASE 1 23(584)
IS USED 3-1/4 Overall
WITHOUT (83) (Maximum) 1
Minimum
IAQ CABINET, 11 (279)
INDOOR AIR A SINGLE 2 Maximum 1
QUALITY RETURN AIR 1 Unit side return air 22-7/16
14 (356) (570)
CABINET PLENUM Opening
AIR FLOW (PCO, Filter MUST Overall
Cabinet, etc.) COVER BOTH (Maximum)
UNIT AND
RETURN SIDE RETURN
AIR BASE 7-1/4 5-5/8
OPENINGS (184) (143) AIR OPENINGS
(Either Side)
23
14-1/2 (368) A Width (65W75) OPTIONAL (584) 3/4
RETURN (19)
17-1/2 (446) B Width (50W98) AIR BASE 26-7/8
21 (533) C Width (50W99) (683)
24-1/2 (622) D Width (51W00) SIDE VIEW
NOTE- Optional Side Return Air Filter Kits are not for use with Optional Return Air Base.
1 Both the unit return air opening and the base return air opening must be covered by a single plenum or IAQ cabinet.
Minimum unit side return air opening dimensions for units requiring 1800 cfm or more of air (W x H): 23 x 11 in. (584 x 279 mm).
The opening can be cut as needed to accommodate plenum or IAQ cabinet while maintaining dimensions shown.
Side return air openings must be cut in the field. There are cutting guides stenciled on the cabinet for the side return air
opening. The size of the opening must not extend beyond the markings on the furnace cabinet.
2 To minimize pressure drop, the largest opening height possible, up to 14 in. (356 mm), is preferred.
ML180UH / Page 13
DIMENSIONS - FURNACE/COIL COMBINED DIMENSIONS
UPFLOW POSITION
C35/C37/CX35/CX38 C35
Model No Cased Uncased
A B A B
C35/CX35 C37 CX38 in. mm in. mm in. mm in. mm
C35/CX35-18/24A
--- --- 16-1/2 419 49-1/2 1257 14-1/8 359 47-1/8 1197
C35/CX35-18/24B
C35/CX35-24A C37-25A CX38-25A
18-1/2 470 51-1/2 1308 16-3/8 416 49-3/8 1254
C35/CX35-24B C37-25B CX38-25B
--- --- CX38-30A 20-1/2 521 53-1/2 1359 --- --- --- --- A
C35/CX35-30A C37-31A CX38-31A
22-1/2 572 55-1/2 1410 20-3/4 527 53-3/4 1365
C35/CX35-30B C37-31B CX38-31B
C35/CX35-30/36A C37-36A CX38-36A B
C35/CX35-30/36B C37-36B CX38-36B 24-1/2 622 57-1/2 1461 22-1/4 565 55-1/4 1403
C35/CX35-30/36C C37-36C CX38-36C
33
C35/CX35-36A C37-38A CX38-38A (838)
24-1/2 622 57-1/2 1461 22-3/8 568 55-3/8 1407
C35/CX35-36B C37-38B CX38-38B
--- C37-42B CX38-42B 24-1/2 622 57-1/2 1461 --- --- --- ---
C35/CX35-48B C37-43B CX38-43B
27-1/2 699 60-1/2 1537 26-1/4 667 59-1/4 1505
C35/CX35-48C C37-43C CX38-43C
C37-48B CX38-44/48B
--- 24-1/2 622 57-1/2 1461 --- --- --- ---
C37-48C CX38-44/48C
C35/CX35-49C C37-49C CX38-49C 29-1/2 749 62-1/2 1588 28-1/2 724 61-1/2 1562
C35/CX35-50/60C C37-50/60C CX38-50/60C 27-1/2 699 60-1/2 1537 25-7/8 657 58-7/8 1495
--- C37-60D CX38-60D 25-1/2 648 58-1/2 1486 --- --- --- ---
CX35-60C C37-62C CX38-62C 31-1/2 800 64-1/2 1638 30-5/8 778 63-5/8 1616
CX35-60D C37-62D CX38-62D 29-1/2 749 62-1/2 1588 28 711 61 1549
HORIZONTAL POSITION
Model A B
Number in. mm in. mm
CH33
B 33 CH33-18A-2F 21-1/2 546 54-1/2 1384
(838) CH33-24/30A-2F, CH33-42B-2F, 26-1/2 673 59-1/2 1511
CH33-36A-2F, CH33-48C-2F,
A CH33-36B-2F, CH33-60D-2F
CH33-36C-2F,
CH33-44/48B-2F, CH33-62D-2F 31-1/2 800 64-1/2 1638
CH33-50/60C-2F,
CH35
CH35-18A-2F, CH35-36A-2F, 26-1/2 673 59-1/2 1511
CH35-24A-2F, CH35-36B-2F,
CH35-24B-2F, CH35-36C-2F,
CH35-30B-2F, CH35-42C-2F,
CH35-48C-2F
CH35-30A-2F, CH35-51C-2F, 31-1/2 880 64-1/2 1638
CH35-42B-2F, CH35-60D-2F
CH35-48B-2F,
ML180UH / Page 14
BLOWER DATA
ML180UH / Page 15
BLOWER DATA
ML180UH / Page 16
REVISIONS
Sections Description of Change
Controls Added iComfort® M30 Smart Thermostat and Remote Outdoor Temperature Sensor.
Visit us at www.lennox.com
For the latest technical information, www.LennoxPROs.com
Contact us at 1-800-4-LENNOX
NOTE - Due to Lennox’ ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability.
Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury.
Installation and service must be performed by a qualified installer and servicing agency. ©2019 Lennox Industries, Inc.