The ML180UH Merit Series gas furnace features an AFUE of 80% and input capacities ranging from 44,000 to 132,000 Btuh, suitable for upflow or horizontal applications. It includes a durable Duralok™ heat exchanger, multi-speed blower, and various optional accessories for enhanced performance and installation flexibility. The unit is certified by AHRI and complies with California NOx standards, with specific installation requirements for certain air quality management districts.

Uploaded by

vco.osc
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
61 views20 pages

Ehb Ml180uh 1904

The ML180UH Merit Series gas furnace features an AFUE of 80% and input capacities ranging from 44,000 to 132,000 Btuh, suitable for upflow or horizontal applications. It includes a durable Duralok™ heat exchanger, multi-speed blower, and various optional accessories for enhanced performance and installation flexibility. The unit is certified by AHRI and complies with California NOx standards, with specific installation requirements for certain air quality management districts.

Uploaded by

vco.osc
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

GAS FURNACES

ML180UH
MERIT® SERIES
Upflow / Horizontal
Bulletin No. 210590
P R O D U C T S P E C I F I C AT I O N S April 2019
Supersedes October 2018

AFUE - 80%
Input - 44,000 to 132,000 Btuh
Nominal Add-on Cooling - 2 to 5 Tons
MODEL NUMBER IDENTIFICATION
ML 1 80 UH 070 X P 36 B
Unit Type 1
Cabinet Width
ML = Merit Series® A = 14-1/2 in.
B = 17-1/2 in.
Stages C = 21 in.
1 = Single-Stage D = 24-1/2 in.

AFUE Nominal Add-On Cooling Capacity


80 = 80% 24 = 2-2.5 tons
36 = 2-3.5 tons
Configuration 48 = 4 tons
UH = Upflow/Horizontal 60 = 4-5 tons

Nominal Gas Heat Input


045 = 44,000 Btuh Blower
070 = 66,000 Btuh P = PSC Multi-Speed Blower Motor
090 = 88,000 Btuh
110 = 110,000 Btuh Low NOx
135 = 132,000 Btuh X = Units meet California Nitrogen Oxides Standard (40 ng/J)

1
Indoor coils with the same letter designation will physically match the furnace.
FEATURES

CONTENTS
Blower Data................................................................ 15 J
Dimensions - Furnace/Coil Combined Dimensions.... 14
Dimensions - Horizontal Position................................ 12
Dimensions - Optional Accessories............................ 13
Dimensions - Upflow Position..................................... 11 B
Features....................................................................... 2
Gas Heat Accessories ................................................. 9 F
High Altitude Derate...................................................... 9 L
Installation Clearances............................................... 10
D
G E
Model Number Identification......................................... 1
Optional Accessories - Order Separately..................... 9 C
Specifications............................................................... 8
K
NOTE - ML180UH FURNACES ARE NOT
AVAILABLE IN CANADA! I
WARRANTY

Duralok™ Aluminized Steel Heat Exchanger - Limited H


twenty year warranty in residential applications, ten
years in non-residential applications.
All other covered components - Limited five year
warranty in residential applications, one year in non-
residential applications.
Refer to Lennox Equipment Limited Warranty certificate
included with equipment for details.
APPROVALS APPLICATIONS
Units are Certified by AHRI. Input capacities of 44,000, 66,000, 88,000, 110,000 and
Units tested and rated according to US DOE test 132,000 Btuh.
procedures and FTC labeling regulations. Energy efficiency (AFUE) of 80%.
“X” models approved by the California Energy Compact cabinet for upflow, horizontal-left or horizontal-
Commission and meet California Seasonal Efficiency right applications.
requirements and California Nitrogen Oxides (NOx)
Utility room, alcove, closet, crawl space, basement or
Standards.
attic installation.
ISO 9001 Registered Manufacturing Quality System.
Lennox add-on indoor coils, high-efficiency air cleaners
Blower data from unit tests conducted in Lennox and humidifiers can easily be added to furnace.
Laboratory air test chamber.
Shipped factory assembled with all controls installed
California Only and wired.
If installed in South Coast Air Quality Management Ready for installation in upflow or horizontal right-hand
District (SCAQMD) only: position without any modifications. Horizontal left-hand
This furnace does not meet the SCAQMD Rule 1111 position requires repositioning of pressure switch.
NOx emission limit (14 ng/J), and thus is subject to a Removable bottom seal panel shipped in place for side
mitigation fee of up to $450. This furnace is not eligible return air is easily removed for bottom/end return air
for the Clean Air Furnace Rebate Program: applications.
www.CleanAirFurnaceRebate.com. Each unit factory test operated to ensure proper
operation.
If installed in San Joaquin Valley Air Pollution Control
District (SJVAPCD) only:
This furnace does not meet the SJVAPCD Rule 4905
NOx emission limit (14 ng/J), and thus is subject to a
mitigation fee of up to $450.

ML180UH / Page 2
FEATURES
HEATING SYSTEM G Flame Rollout Switches (2)
Manual reset switches are factory installed on the front
B Lennox Duralok™ Heat Exchanger Assembly of the burner box.
Heavy gauge aluminized steel heat exchanger.
Crimped seam clamshell type design. Switches provides protection from abnormal operating
conditions.
Designed for normal expansion and contraction.
Minimum resistance to Limit Control
air flow. Automatic reset, primary limit is accurately located on
vestibule panel on all units.
Heat exchanger has
been laboratory life Optional Accessories
cycle tested in excess of
industry standards. High Altitude Pressure Switch Kit
Required on most units for proper unit operation at
Compact size of heat
altitudes from 4,501 to 7500 ft.
exchanger permits low
overall design of furnace Natural Gas to LPG/Propane Conversion Kit
cabinet. Required for field changeover from natural gas to LPG/
Propane.
C Inshot Burners
Aluminized steel inshot burners provide efficient, LPG/Propane to Natural Gas Conversion Kit
trouble-free operation. Required for field changeover from LPG/Propane to
Burner venturi mixes air and gas in correct proportion natural gas.
for proper combustion.
Vent Adaptor (Upflow Applications Only)
Burner assembly is removable from the unit as a single Allows venting through a 6 in.
component for ease of service. masonry chimney without the (152 mm)
need of a flue liner.
D SureLight® Hot Surface Ignitor
Tough, reliable, long-life, trouble-free performance. Manual reset temperature
Silicon nitride ignitor. sensor protects against 7 in.
(178 mm)
abnormal operating conditions.
Cemented to steatite block for protection against current
leakage. Sensor wiring may be routed
from either side of adaptor.
Ignition leads are constructed of nickel plated copper
and are enclosed in high temperature Teflon® insulation Minimum winter design
for dependable operation. temperatures:
−10°F when used with interior masonry chimneys.
E Gas Control Valve +5°F when used with exterior masonry chimneys.
24 volt redundant combination gas control valve
combines manual shut off switch (On-Off), automatic Refer to Winter Design Temperatures Map on page
electric valve (dual) and gas pressure regulation into a 7 for application information. Also refer to the
compact combination control. installation instructions for detailed information.
BLOWER
F Combustion Air Inducer
Shaded pole heavy duty blower prepurges heat H Multi-speed direct drive blower.
exchanger and safely vents flue products. Statically and dynamically balanced.
Pressure switch proves blower operation before Resiliently mounted.
allowing gas valve to open. Blower assembly easily removed for servicing.
Operates only during heating cycle. Blower speeds are easily changed on the integrated
Direct access allows inducer assembly to be rotated furnace control. See blower performance tables.
90° clockwise or counterclockwise to facilitate easy vent
attachment in horizontal applications.

ML180UH / Page 3
FEATURES

I CONTROLS Optional Accessories


SureLight® Integrated Furnace Control iComfort® M30 Smart Wi-Fi Thermostat
Contains all necessary controls and relays to operate Wi-Fi-enabled, electronic 7-day, universal, multi-stage,
furnace. programmable, touchscreen
Combustion air inducer is controlled by the integrated thermostat.
furnace control. Prior to ignition, a pre-purge cycle 4 Heat/2 Cool.
for 15 seconds is initiated. After the main burners are
Auto-changeover.
turned off, a post-purge cycle for 5 seconds is run.
Dual-fuel control with
Flame sensor assures safe and reliable operation.
optional outdoor sensor.
Should loss of flame occur, flame sensor controls will
Controls dehumidification
initiate 4 re-attempts at ignition before locking out unit
during cooling mode and
operation for 60 minutes.
humidification during heating mode.
Watchguard type circuit automatically resets ignition
Offers enhanced capabilities including humidification /
controls after one hour of continuous thermostat
dehumidification / dewpoint measurement and control,
demand after unit lockout, eliminating nuisance calls for
Humiditrol® control, and equipment maintenance
service.
reminders.
Fan control consists of adjustable blower timed-off
Easy to read 4.3 in. color touchscreen (measured
delay (60, 90, 120, 180 seconds - factory setting 120
diagonally).
seconds) and fixed blower timed-on delay (45 seconds).
LCD display with backlight shows the current and set
For air-conditioning applications, blower is automatically
temperature, time, inside relative humidity, system
energized on thermostat demand for cooling.
status (operating mode and schedules) and outside
Integrated furnace control has one red LED to indicate temperature (optional outdoor sensor required).
status and indicate diagnostic codes. Push button recall
Smooth Setback Recovery starts system early to
of the last 5 diagnostic codes aids in troubleshooting.
achieve setpoint at start of program period.
Integrated furnace control has built-in twinning capability
Compressor short-cycle protection (5 minutes).
(“TWIN” terminal on control) to operate two furnaces
simultaneously without any additional controls. A field Up to four separate schedules are available plus
supplied isolation relay is required to operate the Schedule IQ™.
twinned (no thermostat connection) furnace. One-Touch Away Mode - A quick and easy way to set
Two accessory terminals furnished for additional power the cooling and heating setpoints while away.
supply requirements for 120 volt (less than 1 amp) Smart Away™ - Uses geo-fencing technology
power humidifiers and powered air cleaners. to determine when the homeowner is within a
predetermined distance from the home to operate the
24 Volt Transformer system when leaving, away and arriving.
Furnished and factory installed on outside of control
box. 40VA transformer has fuse wired in series. Amazon® Alexa-enabled, smart-home-compatible. It
works with Amazon Echo, Echo Dot and Tap devices.
Field Wiring Make-Up Box Wi-Fi remote monitoring and adjustment through a
Furnished for line voltage wiring. home wireless network for desktop PCs, laptops and
Factory installed internally on left side of furnace. apps for smartphones or tablets.
Box may be installed on right side of furnace. See the iComfort® M30 Smart Wi-Fi Thermostat Product
Specifications bulletin in the Controls section for more
information.

Remote Outdoor Temperature Sensor


Used with the iComfort® M30 Smart Thermostat.
When installed outdoors, sensor
allows thermostat to display outdoor
temperature. Sensor is auto-detected
when connected to thermostat.
NOTE - Sensor is required for the
Enhanced Dehumidification
Accessory (EDA).

ML180UH / Page 4
FEATURES
CONTROLS (continued) CABINET
Optional Accessories (continued) Low-profile, narrow width cabinet allows easy
installation.
Thermostat Heavy-gauge, cold rolled steel construction.
Thermostat (programmable/non-programmable) is not
Pre-painted cabinet finish.
furnished with unit.
Flue outlet on top of cabinet for upflow applications,
See Thermostat bulletins in Controls Section and
can be relocated to either side of cabinet for horizontal
Lennox Price Book for selection.
applications.
Night Service Kit Flanges provided on supply air opening for ease of
Contains most commonly used service parts: plenum connection or alignment with indoor coil.
• Furnace Control J Insulated cabinet with foil faced insulation on sides and
• Ignitor back of heating compartment.
• Flame sensor Complete service access.
• Gas valve K Safety interlock switch automatically shuts off power
• Transformer to unit when blower compartment access panel is
removed.
Air Filter and Rack Kit for Horizontal Return Air L Gas piping and electrical inlets are provided in both
(End) Applications sides of cabinet.
Washable or vacuum cleanable polyurethane frame
type filter and external end return air rack available for Return Air Entry:
field installation. For bottom/end return-air entry for upflow/horizontal
Rack has filter door for easy filter servicing. applications, remove furnished bottom seal panel from
cabinet.
Flanges on rack allow easy duct connection.
For side return-air entry (upflow applications only),
See dimension drawing. corners are marked on either side of cabinet for return
Air Filter and Rack Kit for Upflow Side Return Air air cut-outs.
Applications - Not for use with Return Air Base See dimension drawings.
Washable or vacuum cleanable polyurethane frame NOTE - 60C and 60D size units that require air
type filter and external side return air rack available for volumes over 1800 cfm must have one of the
field installation. following:
Available in single and ten pack kits. 1. S ingle side return air and Optional Return Air
Rack has filter door for easy filter servicing. Base with transition that must accommodate
Flanges on rack allow easy duct connection. required 20 x 25 x 1 inch air filter to maintain
proper velocity.
Field installs on either side of unit cabinet. See
dimension drawing. 2. Bottom return air.
3. Return air from both sides.
4. Bottom and one side return air.
See Blower Performance Tables for additional
information.

Coil Match-Up
All furnaces exactly match Lennox cased upflow
indoor coils and horizontal indoor coils with same letter
designation (A, B, C, D) in model number. No adaptor
required. Engaging holes furnished on cabinet for
alignment.
Lennox uncased coils match furnaces without any
overhang but require an optional adaptor base or field
fabricated transition to match furnace opening. See coil
bulletin for additional information.

Low Leakage Cabinet


All models have less than 2% air leakage and meet
ANSI/ASHRAE Standard 193-2010 “Method of Test for
Determining the Air Tightness of HVAC Equipment”.

ML180UH / Page 5
FEATURES
CABINET (continued) FILTER (not furnished)
Optional Accessories Filter and provisions for external mounting must be field
provided.
Horizontal Suspension Kit
Optional Accessories
Provides suspension of unit and indoor coil in horizontal
applications. Air Filter and Rack Kit for Horizontal Return Air
Allows complete service access. (End) Applications
Consists of corner mounted hanging brackets with Washable or vacuum cleanable polyurethane frame
vibration isolators, return air end support rail and type filter and external end return air rack available for
hardware for assembly. field installation.
Metal hanging straps must be field provided. Rack has filter door for easy filter servicing.
Flanges on rack allow easy duct connection.
Return Air Base
See dimension drawing.
A field fabricated transition or Return Air Base is
required when using an IAQ product higher than 14- Air Filter and Rack Kit for Upflow Side Return Air
3/16 in. installed next to the unit and serviced from the Applications - Not for use with Return Air Base
front. IAQ products higher than 20 in. require a field
Washable or vacuum cleanable polyurethane frame
fabricated transition.
type filter and external side return air rack available for
Base must be used for 60C and 60D models with air field installation.
volumes over 1800 cfm in upflow applications when
Available in single and ten pack kits.
only one side return is required.
Rack has filter door for easy filter servicing.
Cabinet is shipped flat for easy field assembly and is
pre-painted steel to match the furnace. Flanges on rack allow easy duct connection.
See Dimension Drawing. Field installs on either side of unit cabinet. See
dimension drawing.
High Performance Economizer
(Commercial Applications Only)
Designed for applications requiring outdoor air to be
utilized in a commercial HVAC system. Allows the
entry of fresh outdoor air for free cooling, reducing the
requirement for mechanical cooling.
Heavy gauge galvanized steel cabinet lined with thick
fiberglass insulation.
Mixed air sensor, outdoor air sensor and 24VAC
transformer furnished.
Approved for California Title 24 building standards.
ASHRAE 90.1-2010 compliant.
See separate Product Specifications bulletin for
additional information and available control and sensor
options.

ML180UH / Page 6
99% WINTER DESIGN TEMPERATURES FOR THE CONTIGUOUS UNITED STATES

5 oF −10oF

17oF

−10oF
27 F
o

5 oF

−10oF
37 F o

17oF

27oF

37oF

This map is a necessarily generalized guide to temperatures in the contiguous Unites States. Temperatures shown for
areas such as mountainous regions and large urban centers may not be accurate. The data used to develop this map
was taken from the 1993 ASHRAE Fundamentals Handbook (Chapter 24, Table 1: Climate Conditions for the United
States).
Reprinted with permission from NFPA 54: National Fuel Gas Code 1999, National Fire Protection Association, Quincy,
MA 02269. This reprinted material is not the complete and official position of the National Fire Protection Association on
the referenced subject, which is represented only by the standard in its entirety.

ML180UH / Page 7
SPECIFICATIONS
Gas Model No. ML180UH045P24A ML180UH045P36A ML180UH070P24A ML180UH070P36A
Heating Model No. - Low Nox --- ML180UH045XP36A --- ML180UH070XP36A
Performance AHRI Ref. No. Non “X” Models 4208204 4208205 4208206 4208207
“X” Models --- 4208213 --- 4208214
1
AFUE 80% 80% 80% 80%
Input - Btuh 44,000 44,000 66,000 66,000
Output - Btuh 35,000 35,000 54,000 54,000
Temperature rise range - °F 20 - 50 15 - 45 30 - 60 30 - 60
Gas Manifold Pressure (in. w.g.) 3.5 / 10.0 3.5 / 10.0 3.5 / 10.0 3.5 / 10.0
Nat. Gas / LPG/Propane
High Static - in. w.g. 0.50 0.50 0.50 0.50
Connections Flue connection - in. round 4 4 4 4
in. Gas pipe size IPS 1/2 1/2 1/2 1/2
Indoor Wheel nom. dia. x width - in. 10 x 7 10 x 8 10 x 7 10 x 8
Blower Motor output - hp 1/5 1/3 1/5 1/3
Tons of add-on cooling 1.5 - 2 2-3 1.5 - 2 2-3
Air Volume Range - cfm 345 - 1130 650 - 1670 420 - 1160 785 - 1660
Electrical Voltage 120 volts - 60 hertz - 1 phase
Data Blower motor full load amps 3.1 6.1 3.1 6.1
Maximum overcurrent protection 15 15 15 15
Shipping Data lbs. - 1 package 105 110 114 119
SPECIFICATIONS
Gas Model No. ML180UH090P36B ML180UH090P48B ML180UH110P48C
Heating Model No. - Low Nox --- ML180UH090XP48B ---
Performance AHRI Ref. No. Non “X” Models 4208208 4208209 4208210
“X” Models --- 4208215 ---
1
AFUE 80% 80% 80%
Input - Btuh 88,000 88,000 110,000
Output - Btuh 71,000 71,000 89,000
Temperature rise range - °F 25 - 55 25 - 55 25 - 55
Gas Manifold Pressure (in. w.g.) 3.5 / 10.0 3.5 / 10.0 3.5 / 10.0
Nat. Gas / LPG/Propane
High Static - in. w.g. 0.50 0.50 0.50
Connections Flue connection - in. round 4 4 4
in. Gas pipe size IPS 1/2 1/2 1/2
Indoor Wheel nom. dia. x width - in. 10 x 9 10 x 10 10 x 10
Blower Motor output - hp 1/3 1/2 1/2
Tons of add-on cooling 2-3 3-4 3-4
Air Volume Range - cfm 680 - 1795 920 - 2160 910 - 2170
Electrical Voltage 120 volts - 60 hertz - 1 phase
Data Blower motor full load amps 6.1 8.2 8.2
Maximum overcurrent protection 15 15 15
Shipping Data lbs. - 1 package 131 138 151
SPECIFICATIONS
Gas Model No. ML180UH110P60C ML180UH135P60D
Heating Model No. - Low Nox ML180UH110XP60C ---
Performance AHRI Ref. No. Non “X” Models 4208211 4208212
“X” Models 4208216 ---
1
AFUE 80% 80%
Input - Btuh 110,000 132,000
Output - Btuh 89,000 107,000
Temperature rise range - °F 25 - 55 30 - 60
Gas Manifold Pressure (in. w.g.) 3.5 / 10.0 3.5 / 10.0
Nat. Gas / LPG/Propane
High Static - in. w.g. 0.50 0.50
Connections Flue connection - in. round 4 4
in. Gas pipe size IPS 1/2 1/2
Indoor Wheel nom. dia. x width - in. 11-1/2 x 10 11 x 11
Blower Motor output - hp 1 1
Tons of add-on cooling 4-5 4-5
Air Volume Range - cfm 1355 - 2715 1380 - 2810
Electrical Voltage 120 volts - 60 hertz - 1 phase
Data Blower motor full load amps 10 11.5
Maximum overcurrent protection 15 15
Shipping Data lbs. - 1 package 161 174
NOTE - Filters and provisions for mounting are not furnished and must be field provided.
1
Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces.
ML180UH / Page 8
OPTIONAL ACCESSORIES - ORDER SEPARATELY
“A” Width “B” Width “C” Width “D” Width
Models Models Models Models
CABINET ACCESSORIES
Horizontal Suspension Kit - Horizontal only 51W10 51W10 51W10 51W10
Return Air Base - Upflow only 65W75 50W98 50W99 51W00
High Performance Economizer (Commercial Only) 10U53 10U53 10U53 10U53
Controls
iComfort® M30 Smart Wi-Fi Thermostat 15Z69 15Z69 15Z69 15Z69
Remote Outdoor Air Temperature Sensor X2658 X2658 X2658 X2658
FILTERS
1
Air Filter and Rack Kit Horizontal (end) 87L95 87L96 87L97 87L98
Size of filter - in. 14 x 25 x 1 18 x 25 x 1 20 x 25 x 1 25 x 25 x 1
Side Return Single 44J22 44J22 44J22 44J22
Ten Pack 66K63 66K63 66K63 66K63
Size of filter - in. 16 x 25 x 1 16 x 25 x 1 16 x 25 x 1 16 x 25 x 1
NIGHT SERVICE KITS
Night Service Kit 68W80 68W80 68W80 68W80
VENTING
Vent Adaptor − 6 in. conn. size upflow applications only 18M79 18M79 18M79 18M79
1
Cleanable polyurethane, frame-type filter.

GAS HEAT ACCESSORIES


Natural Gas
High Altitude Natural Gas to LPG/Propane
High Altitude
Input Pressure Switch Kit LPG/Propane Kit to Natural Gas Kit
Orifice Kit
0 - 4500 ft. 4501 - 7500 ft. 7501 - 10,000 ft. 0 - 7500 ft. 7501 - 10,000 ft. 0 - 7500 ft. 7501 - 10,000 ft.
045 No Change 80W52 80W51 11K49 11K44 73W81 73W37
070 No Change 80W52 80W51 11K49 11K44 73W81 73W37
090 No Change 80W52 80W51 11K49 11K44 73W81 73W37
110 No Change 80W57 80W52 11K49 11K44 73W81 73W37
135 No Change 80W52 80W51 11K49 11K44 73W81 73W37

HIGH ALTITUDE DERATE


NOTE - Units may be installed at altitudes up to 2000 ft. above sea level without any modifications.
At altitudes above 2000 ft. units must be derated to match information in the shaded areas shown below.
NOTE - This is the only permissible derate for these units.
Gas Manifold Pressure (Outlet) in. w.g. Line Pressure - in. w.g.

0 - 2000 Feet 2001 - 4500 Feet 4501 - 7500 Feet 7501 - 10,000 ft. Minimum
Input
Maximum
Natural LPG/ Natural LPG/ Natural LPG/ 1
Natural LPG/ Natural LPG/
Gas Propane Gas Propane Gas Propane Gas Propane Gas Propane
045 3.5 10 3.2 10 3 10 3.5 10 4.5 11 13
070 3.5 10 3.2 10 2.8 10 3.5 10 4.5 11 13
090 3.5 10 3.2 10 2.7 9.6 3.5 10 4.5 11 13
110 3.5 10 3.5 10 3 9.6 3.5 10 4.5 11 13
135 3.5 10 3.5 10 2.9 9.6 3.5 10 4.5 11 13
1
Natural Gas High Altitude Orifice Kit required.

ML180UH / Page 9
INSTALLATION CLEARANCES
UPFLOW POSITION HORIZONTAL POSITION
Vent Type Type B1 Type C Vent Type Type B1 Type C
Sides 0 (0) 1
0 (0) End 1
2 1
2
Rear 0 (0) 0 (0) Rear 0 (0) 0 (0)
Top 1 (25) 1 (25) Top 1
0 (0) 1
0 (0)
Front 2-1/4 (57) 2-1/4 (57) Front 2-1/4 (57) 2-1/4 (57)
Front (service/alcove) 24 (610) 24 (610) Front (service) 24 (610) 24 (610)
Floor Combustible Combustible Floor Combustible Combustible
Flue 1 (25) 6 (152) Flue 1 (25) 6 (152)
NOTE − Air for combustion must conform to the methods outlined in the National NOTE − Air for combustion must conform to the methods outlined in the National
Fuel Gas Code (NFPA 54/ANSI-Z223.1). Fuel Gas Code (NFPA 54/ANSI-Z223.1).
NOTE − In the U.S. flue sizing must conform to the methods outlined in the NOTE − In the U.S. flue sizing must conform to the methods outlined in the
current National Fuel Gas Code (NFPA 54/ANSI-Z223.1) or applicable current National Fuel Gas Code (NFPA 54/ANSI-Z223.1) or applicable
provisions of local building codes. provisions of local building codes.
1
Left side requires 4 in. if single wall vent is used on 14-1/2 in. cabinets, 2 in. on 1
Line contact installation permissible between jacket top or sides and building
17-1/2 in. cabinets. joists.

ML180UH / Page 10
DIMENSIONS - UPFLOW POSITION

3-1/8 (79)
1 NOTE - 60C and 60D size units that require air volumes over
1800 cfm must have one of the following:
1. Single side return air and Optional Return Air Base
with transition that must accommodate required D
20 x 25 x 1 inch (508 x 635 x 25 mm) air filter to
maintain proper velocity.
2. Bottom return air. SUPPLY AIR
3. Return air from both sides. OPENING
4. Bottom and one side return air. FLUE OUTLET
See Blower Performance Tables for additional information. (Top)

2 Flue outlet may be horizontal but furnace must be


vented vertically
3 Optional External Side Return Air Filter Kit is not for use

with the optional Return Air Base. 3 OPTIONAL


23-3/4
EXTERNAL (603)
SIDE RETURN 25
AIR FILTER KIT (635)
(Either Side) TOP VIEW
3/4(19) 27-3/4
Front Panel (705)
A 3-1/4 (83)
19-7/16 9/16
B 9/16 (14) 3 (76) Right
(14)
6-3/4 (171) Left (494)

2 FLUE OUTLET
(Either Side)
9-1/8 (232) Right
3 OPTIONAL ELECTRICAL INLET
8-5/8 (219) Left
EXTERNAL (Either Side)
SIDE RETURN
AIR FILTER KIT
(Either Side)
33 5-3/8 (137) Right GAS PIPING INLET
(838) 2-3/16 (56) Left (Either Side)

ELECTRICAL
23 1-1/2
INLET (Either Side) (584) (38)
14-3/4
(375)
1 SideReturn 14
16 Air Opening (356)
(406) (Either Side)

1-15/16 (49)
5/8
3/4 3/4 (16) 3-1/4 23-1/2
(19) C (19) (83) (597)
1 BottomReturn 1 Bottom Return
Air Opening Air Opening

FRONT VIEW SIDE VIEW

A B C D
Model No.
in. mm in. mm in. mm in. mm
ML180UH045P24A
ML180UH045P36A
14-1/2 368 13-3/8 340 13 330 4-3/4 121
ML180UH070P24A
ML180UH070P36A
ML180UH090P36B
17-1/2 446 16-3/8 416 16 406 6-1/4 159
ML180UH090P48B
ML180UH110P48C
21 533 19-7/8 504 19-1/2 495 8 203
ML180UH110P60C
ML180UH135P60D 24-1/2 622 23-3/8 594 23 584 9-3/4 248

ML180UH / Page 11
DIMENSIONS - HORIZONTAL POSITION
LEFT-HAND AIR DISCHARGE
1 Flueoutlet may be from end but
furnace must be vented vertically
GAS PIPING INLET
(Top or Bottom)
9-1/8 (232) Top AIR
8-5/8 (219) Bottom FLOW
ELECTRICAL INLET
(Top or Bottom)
FLUE OUTLET
(Top)
3/4 (19)
3 (76) Front Panel

6-3/4 5-3/8 (137) Top


(171) 2-3/16 (56) Bottom
TOP VIEW
27-3/4 1FLUE 33 27-3/4
(705) 9/16 OUTLET (838) 3/4 (705)
(14) (End) (19)

9/16 19-7/16 4-1/4 23-1/2


(14) (494) (108) (597)
AIR
SUPPLY B A FLOW A C RETURN
AIR AIR
OPENING D OPENING

END VIEW FRONT VIEW END VIEW


3-1/8
(79)
RIGHT-HAND AIR DISCHARGE
1 Flue outlet may be horizontal but
furnace must be vented vertically
GAS PIPING INLET
(Top or Bottom)
AIR
ELECTRICAL INLET FLOW
6-3/4
1 FLUE OUTLET
(Top or Bottom) (171) (Top)

3/4 (19)
Front Panel 3 (76)
2-3/16 (56) Top
5-3/8 (137) Bottom 8-5/8 (219) Top
9-1/8 (232) Bottom
TOP VIEW
27-3/4 33 1 FLUE OUTLET 27-3/4
(705) (838) (End) 3-1/8 (705)
(79)

23-1/2 4-1/4 D 19-7/16


(597) (108) (494)
AIR 9/16
C A A B (14)
RETURN FLOW SUPPLY
AIR AIR
OPENING OPENING

3/4 9/16
END VIEW (19) FRONT VIEW END VIEW (14)

A B C D
Model No.
in. mm in. mm in. mm in. mm
ML180UH045P24A
ML180UH045P36A
14-1/2 368 13-3/8 340 13 330 4-3/4 121
ML180UH070P24A
ML180UH070P36A
ML180UH090P36B
17-1/2 446 16-3/8 416 16 406 6-1/4 159
ML180UH090P48B
ML180UH110P48C
21 533 19-7/8 504 19-1/2 495 8 203
ML180UH110P60C
ML180UH135P60D 24-1/2 622 23-3/8 594 23 584 9-3/4 248

ML180UH / Page 12
DIMENSIONS - OPTIONAL ACCESSORIES

HORIZONTAL (END) FILTER KIT


1-1/4
(32)
24−3/4
5/8 (629)
(16)

5/8 Furnace A B
Catalog
(16) Cabinet
Number in. mm in. mm
Width

B A 87L95 14 356 12-3/4 324


RETURN
A AIR B 87L96 18 457 16-3/4 425
OPENING AIR FLOW
5/8 C 87L97 21 533 18-3/4 476
(16)
23−1/2 D 87L98 25 635 23-3/4 603
(597)

AIR FILTER
5/8 (Furnished)
(16)
SIDE VIEW FRONT VIEW

Optional Return Air Base


(Upflow Applications Only - For use with A, B, C and D cabinets)

FURNACE
FRONT

IF BASE 1 23(584)
IS USED 3-1/4 Overall
WITHOUT (83) (Maximum) 1
Minimum
IAQ CABINET, 11 (279)
INDOOR AIR A SINGLE 2 Maximum 1
QUALITY RETURN AIR 1 Unit side return air 22-7/16
14 (356) (570)
CABINET PLENUM Opening
AIR FLOW (PCO, Filter MUST Overall
Cabinet, etc.) COVER BOTH (Maximum)
UNIT AND
RETURN SIDE RETURN
AIR BASE 7-1/4 5-5/8
OPENINGS (184) (143) AIR OPENINGS
(Either Side)

23
14-1/2 (368) A Width (65W75) OPTIONAL (584) 3/4
RETURN (19)
17-1/2 (446) B Width (50W98) AIR BASE 26-7/8
21 (533) C Width (50W99) (683)
24-1/2 (622) D Width (51W00) SIDE VIEW

NOTE- Optional Side Return Air Filter Kits are not for use with Optional Return Air Base.
1 Both the unit return air opening and the base return air opening must be covered by a single plenum or IAQ cabinet.
Minimum unit side return air opening dimensions for units requiring 1800 cfm or more of air (W x H): 23 x 11 in. (584 x 279 mm).
The opening can be cut as needed to accommodate plenum or IAQ cabinet while maintaining dimensions shown.
Side return air openings must be cut in the field. There are cutting guides stenciled on the cabinet for the side return air
opening. The size of the opening must not extend beyond the markings on the furnace cabinet.
2 To minimize pressure drop, the largest opening height possible, up to 14 in. (356 mm), is preferred.

ML180UH / Page 13
DIMENSIONS - FURNACE/COIL COMBINED DIMENSIONS

UPFLOW POSITION
C35/C37/CX35/CX38 C35
Model No Cased Uncased
A B A B
C35/CX35 C37 CX38 in. mm in. mm in. mm in. mm
C35/CX35-18/24A
--- --- 16-1/2 419 49-1/2 1257 14-1/8 359 47-1/8 1197
C35/CX35-18/24B
C35/CX35-24A C37-25A CX38-25A
18-1/2 470 51-1/2 1308 16-3/8 416 49-3/8 1254
C35/CX35-24B C37-25B CX38-25B
--- --- CX38-30A 20-1/2 521 53-1/2 1359 --- --- --- --- A
C35/CX35-30A C37-31A CX38-31A
22-1/2 572 55-1/2 1410 20-3/4 527 53-3/4 1365
C35/CX35-30B C37-31B CX38-31B
C35/CX35-30/36A C37-36A CX38-36A B
C35/CX35-30/36B C37-36B CX38-36B 24-1/2 622 57-1/2 1461 22-1/4 565 55-1/4 1403
C35/CX35-30/36C C37-36C CX38-36C
33
C35/CX35-36A C37-38A CX38-38A (838)
24-1/2 622 57-1/2 1461 22-3/8 568 55-3/8 1407
C35/CX35-36B C37-38B CX38-38B
--- C37-42B CX38-42B 24-1/2 622 57-1/2 1461 --- --- --- ---
C35/CX35-48B C37-43B CX38-43B
27-1/2 699 60-1/2 1537 26-1/4 667 59-1/4 1505
C35/CX35-48C C37-43C CX38-43C
C37-48B CX38-44/48B
--- 24-1/2 622 57-1/2 1461 --- --- --- ---
C37-48C CX38-44/48C
C35/CX35-49C C37-49C CX38-49C 29-1/2 749 62-1/2 1588 28-1/2 724 61-1/2 1562
C35/CX35-50/60C C37-50/60C CX38-50/60C 27-1/2 699 60-1/2 1537 25-7/8 657 58-7/8 1495
--- C37-60D CX38-60D 25-1/2 648 58-1/2 1486 --- --- --- ---
CX35-60C C37-62C CX38-62C 31-1/2 800 64-1/2 1638 30-5/8 778 63-5/8 1616
CX35-60D C37-62D CX38-62D 29-1/2 749 62-1/2 1588 28 711 61 1549

HORIZONTAL POSITION
Model A B
Number in. mm in. mm
CH33
B 33 CH33-18A-2F 21-1/2 546 54-1/2 1384
(838) CH33-24/30A-2F, CH33-42B-2F, 26-1/2 673 59-1/2 1511
CH33-36A-2F, CH33-48C-2F,
A CH33-36B-2F, CH33-60D-2F
CH33-36C-2F,
CH33-44/48B-2F, CH33-62D-2F 31-1/2 800 64-1/2 1638
CH33-50/60C-2F,
CH35
CH35-18A-2F, CH35-36A-2F, 26-1/2 673 59-1/2 1511
CH35-24A-2F, CH35-36B-2F,
CH35-24B-2F, CH35-36C-2F,
CH35-30B-2F, CH35-42C-2F,
CH35-48C-2F
CH35-30A-2F, CH35-51C-2F, 31-1/2 880 64-1/2 1638
CH35-42B-2F, CH35-60D-2F
CH35-48B-2F,

ML180UH / Page 14
BLOWER DATA

ML180UH045P24A PERFORMANCE (Less Filter) ML180UH070P36A PERFORMANCE (Less Filter)


External Air Volume / Watts at Various Blower Speeds External Air Volume / Watts at Various Blower Speeds
Static Medium- Medium- Static Medium- Medium-
High Low High Low
Pressure High Low Pressure High Low
in. w.g. cfm Watts cfm Watts cfm Watts cfm Watts in. w.g. cfm Watts cfm Watts cfm Watts cfm Watts
0.00 1130 453 900 328 750 261 680 237 0.00 1660 696 1370 604 1095 495 935 386
0.10 1115 432 885 321 735 255 670 230 0.10 1620 658 1365 568 1115 468 945 374
0.20 1100 413 870 315 720 249 655 223 0.20 1580 621 1355 535 1135 442 960 362
0.30 1070 396 855 304 700 241 640 217 0.30 1520 595 1335 513 1130 423 955 350
0.40 1030 375 830 294 685 234 620 209 0.40 1480 562 1300 478 1100 403 945 335
0.50 990 356 800 283 655 223 590 200 0.50 1400 520 1270 450 1080 382 925 320
0.60 930 335 750 261 610 207 535 186 0.60 1340 490 1205 420 1035 358 880 301
0.70 870 315 705 245 540 193 490 175 0.70 1245 458 1125 393 975 333 835 282
0.80 785 285 615 223 455 175 405 158 0.80 1160 434 1045 364 915 310 775 262
0.90 615 247 485 196 375 157 345 143 0.90 1045 393 940 334 830 283 785 268

ML180UH045P36A PERFORMANCE (Less Filter) ML180UH090P36B PERFORMANCE (Less Filter)


External Air Volume / Watts at Various Blower Speeds External Air Volume / Watts at Various Blower Speeds
Static Medium- Medium- Static Medium- Medium-
High Low High Low
Pressure High Low Pressure High Low
in. w.g. cfm Watts cfm Watts cfm Watts cfm Watts in. w.g. cfm Watts cfm Watts cfm Watts cfm Watts
0.00 1670 711 1335 614 1140 485 925 388 0.00 1795 781 1450 606 1195 464 970 390
0.10 1620 663 1335 577 1130 470 940 376 0.10 1760 730 1435 576 1185 452 970 378
0.20 1570 619 1330 543 1115 455 950 366 0.20 1725 683 1420 547 1170 440 975 368
0.30 1525 598 1315 511 1140 432 950 349 0.30 1685 656 1410 525 1170 420 980 356
0.40 1470 552 1275 491 1125 413 945 336 0.40 1630 625 1370 501 1150 400 955 340
0.50 1400 525 1235 455 1085 384 925 317 0.50 1535 569 1315 469 1125 391 925 326
0.60 1330 486 1185 422 1050 361 885 300 0.60 1470 533 1275 440 1085 367 910 309
0.70 1225 450 1135 395 995 336 840 283 0.70 1365 490 1185 407 1020 344 840 290
0.80 1135 418 1010 359 925 315 785 258 0.80 1255 466 1105 380 935 314 785 266
0.90 1020 388 930 329 820 278 650 227 0.90 1160 430 1000 352 815 285 680 258

ML180UH070P24A PERFORMANCE (Less Filter) ML180UH090P48B PERFORMANCE (Less Filter)


External Air Volume / Watts at Various Blower Speeds External Air Volume / Watts at Various Blower Speeds
Static High Medium Low Static Medium- Medium-
Pressure High Low
Pressure High Low
in. w.g. cfm Watts cfm Watts cfm Watts
in. w.g. cfm Watts cfm Watts cfm Watts cfm Watts
0.00 1160 450 1005 380 865 309
0.00 2160 873 1825 775 1515 649 1260 544
0.10 1135 439 990 369 845 299
0.10 2030 804 1780 719 1525 613 1280 518
0.20 1115 429 975 358 820 289
0.20 1910 740 1740 666 1535 580 1305 493
0.30 1085 410 955 348 790 279
0.30 1840 698 1705 643 1500 551 1305 474
0.40 1045 389 925 335 775 270
0.40 1770 664 1635 594 1460 517 1280 445
0.50 1015 374 885 321 735 260
0.50 1665 625 1560 567 1410 483 1225 420
0.60 965 358 835 307 700 248
0.60 1585 595 1470 523 1330 451 1190 391
0.70 890 335 780 289 635 232
0.70 1470 561 1365 483 1260 421 1115 368
0.80 810 315 700 268 560 214
0.80 1355 514 1230 433 1155 392 1020 338
0.90 715 289 565 238 420 189
0.90 1200 471 1120 399 1020 345 920 315

ML180UH / Page 15
BLOWER DATA

ML180UH110P48C PERFORMANCE (Less Filter)


External Air Volume / Watts at Various Blower Speeds
Static Medium- Medium-
High Low
Pressure High Low
in. w.g. cfm Watts cfm Watts cfm Watts cfm Watts
0.00 2170 980 1845 792 1565 678 1270 564
0.10 2125 919 1820 747 1555 648 1300 540
0.20 2080 862 1790 705 1540 619 1335 516
0.30 2015 807 1745 652 1545 587 1335 498
0.40 1940 748 1695 629 1505 552 1320 470
0.50 1850 716 1635 581 1470 523 1295 449
0.60 1775 679 1575 560 1395 484 1235 417
0.70 1680 637 1470 508 1320 450 1170 387
0.80 1560 592 1350 469 1205 404 1050 345
0.90 1425 546 1190 424 1060 362 910 307

ML180UH110P60C PERFORMANCE (Less Filter)


Air Volume / Watts at Different Blower Speeds
Single Side Return Air − Air volumes in bold require
External Bottom Return Air, Side Return Air from Both Sides or Optional Return Air Base and field fabricated transition to
Static Return Air from Bottom and One Side. accommodate 20 x 25 x 1 in. air filter in order to maintain
Pressure proper air velocity.
in. w.g. High Medium-High Medium-Low Low High Medium-High Medium-Low Low
cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts
0.00 2575 1391 2270 1050 1845 860 1430 661 2715 1509 2175 1103 1695 858 1410 653
0.10 2520 1359 2250 1034 1860 841 1455 654 2605 1454 2160 1060 1740 848 1430 651
0.20 2465 1329 2230 1018 1870 823 1480 647 2505 1401 2150 1018 1785 838 1450 649
0.30 2385 1307 2180 981 1885 809 1540 646 2435 1349 2115 991 1795 818 1485 638
0.40 2295 1256 2105 942 1865 778 1570 638 2350 1308 2070 965 1805 801 1480 631
0.50 2200 1214 2055 909 1845 762 1570 619 2260 1274 2010 929 1785 775 1480 621
0.60 2130 1186 1985 882 1795 741 1550 604 2175 1228 1955 901 1755 752 1490 611
0.70 2015 1150 1890 848 1720 711 1505 580 2085 1186 1850 853 1710 722 1460 594
0.80 1905 1105 1810 815 1675 687 1470 565 1965 1147 1785 818 1640 689 1425 567
0.90 1795 1054 1710 779 1545 647 1375 533 1830 1094 1700 794 1555 662 1355 545

ML180UH135P60D PERFORMANCE (Less Filter)


Air Volume / Watts at Different Blower Speeds
Single Side Return Air − Air volumes in bold require
External Bottom Return Air, Side Return Air from Both Sides or Optional Return Air Base and field fabricated transition to
Static Return Air from Bottom and One Side. accommodate 20 x 25 x 1 in. air filter in order to maintain
Pressure proper air velocity.
in. w.g. High Medium-High Medium-Low Low High Medium-High Medium-Low Low
cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts
0.00 2785 1492 2205 1083 1665 840 1345 632 2810 1528 2185 1100 1705 835 1260 622
0.10 2750 1441 2220 1056 1725 825 1395 625 2725 1463 2180 1075 1715 827 1320 624
0.20 2720 1392 2235 1029 1785 810 1445 618 2640 1400 2180 1051 1720 819 1380 626
0.30 2605 1362 2220 1002 1820 800 1460 623 2575 1374 2165 1005 1790 803 1420 622
0.40 2495 1312 2185 968 1845 779 1485 616 2495 1343 2145 988 1775 791 1450 617
0.50 2420 1275 2135 939 1825 767 1505 605 2405 1292 2105 948 1780 777 1470 610
0.60 2335 1234 2080 909 1825 753 1495 593 2305 1257 2045 914 1775 753 1480 593
0.70 2220 1190 1995 864 1760 716 1475 576 2215 1214 1970 884 1740 727 1455 583
0.80 2120 1157 1890 835 1680 686 1435 558 2110 1170 1890 851 1675 699 1430 565
0.90 1985 1102 1790 794 1605 656 1390 536 1985 1122 1790 811 1600 667 1380 543

ML180UH / Page 16
REVISIONS
Sections Description of Change

Controls Added iComfort® M30 Smart Thermostat and Remote Outdoor Temperature Sensor.

Visit us at www.lennox.com
For the latest technical information, www.LennoxPROs.com
Contact us at 1-800-4-LENNOX

NOTE - Due to Lennox’ ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability.
Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury.
Installation and service must be performed by a qualified installer and servicing agency. ©2019 Lennox Industries, Inc.

You might also like