Product datasheet
Specifications
variable speed drive, Altivar
Machine ATV320, 5.5kW, 380 to
500V, 3 phases, compact
ATV320U55N4C
Main
Range of product Altivar Machine ATV320
Product or component type Variable speed drive
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Product specific application Complex machines
Variant Standard version
Format of the drive Compact
Mounting mode Wall mount
Communication port protocol Modbus serial
CANopen
Option card Communication module, CANopen
Communication module, EtherCAT
Communication module, Profibus DP V1
Communication module, PROFINET
Communication module, Ethernet Powerlink
Communication module, EtherNet/IP
Communication module, DeviceNet
[Us] rated supply voltage 380...500 V - 15...10 %
nominal output current 14.3 A
Motor power kW 5.5 kW for heavy duty
EMC filter Integrated
IP degree of protection IP20
Complementary
Discrete input number 7
Discrete input type STO safe torque off, 24 V DC, impedance: 1.5 kOhm
DI1...DI6 logic inputs, 24 V DC (30 V)
DI5 programmable as pulse input: 0…30 kHz, 24 V DC (30 V)
Discrete input logic Positive logic (source)
Negative logic (sink)
Discrete output number 3
Discrete output type Open collector DQ+ 0…1 kHz 30 V DC 100 mA
Open collector DQ- 0…1 kHz 30 V DC 100 mA
Analogue input number 3
Analogue input type AI1 voltage: 0...10 V DC, impedance: 30 kOhm, resolution 10 bits
AI2 bipolar differential voltage: +/- 10 V DC, impedance: 30 kOhm, resolution 10 bits
AI3 current: 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by
configuration), impedance: 250 Ohm, resolution 10 bits
Analogue output number 1
30-May-2025 1
Analogue output type Software-configurable current AQ1: 0...20 mA impedance 800 Ohm, resolution 10
bits
Software-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm, resolution 10
bits
Relay output type Configurable relay logic R1A 1 NO electrical durability 100000 cycles
Configurable relay logic R1B 1 NC electrical durability 100000 cycles
Configurable relay logic R1C
Configurable relay logic R2A 1 NO electrical durability 100000 cycles
Configurable relay logic R2C
Maximum switching current Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7
ms: 2 A at 250 V AC
Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7
ms: 2 A at 30 V DC
Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 250 V AC
Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 30 V DC
Minimum switching current Relay output R1A, R1B, R1C, R2A, R2C: 5 mA at 24 V DC
Method of access Slave CANopen
4 quadrant operation possible True
Asynchronous motor control Voltage/frequency ratio, 5 points
profile Flux vector control without sensor, standard
Voltage/frequency ratio - Energy Saving, quadratic U/f
Flux vector control without sensor - Energy Saving
Voltage/frequency ratio, 2 points
Synchronous motor control profile Vector control without sensor
Maximum output frequency 0.599 kHz
Acceleration and deceleration Linear
ramps U
S
CUS
Ramp switching
Acceleration/deceleration ramp adaptation
Acceleration/deceleration automatic stop with DC injection
Motor slip compensation Automatic whatever the load
Adjustable 0...300 %
Not available in voltage/frequency ratio (2 or 5 points)
Switching frequency 2...16 kHz adjustable
4...16 kHz with derating factor
Nominal switching frequency 4 kHz
Braking to standstill By DC injection
Brake chopper integrated True
Line current 20.7 A at 380 V (heavy duty)
14.5 A at 500 V (heavy duty)
Maximum input current 20.7 A
Maximum output voltage 500 V
Apparent power 12.6 kVA at 500 V (heavy duty)
Network frequency 50...60 Hz
Relative symmetric network 5%
frequency tolerance
Prospective line Isc 22 kA
Base load current at high 14.3 A
overload
Power dissipation in W Fan: 195.0 W at 380 V, switching frequency 4 kHz
With safety function Safely True
Limited Speed (SLS)
With safety function Safe brake False
management (SBC/SBT)
2 30-May-2025
With safety function Safe False
Operating Stop (SOS)
With safety function Safe Position False
(SP)
With safety function Safe False
programmable logic
With safety function Safe Speed False
Monitor (SSM)
With safety function Safe Stop 1 True
(SS1)
With sft fct Safe Stop 2 (SS2) False
With safety function Safe torque True
off (STO)
With safety function Safely False
Limited Position (SLP)
With safety function Safe False
Direction (SDI)
Protection type Input phase breaks: drive
Overcurrent between output phases and earth: drive
Overheating protection: drive
Short-circuit between motor phases: drive
Thermal protection: drive
Width 150 mm
Height 232.0 mm
Depth 178.0 mm
Net weight 3.5 kg
Transient overtorque 170…200 % of nominal motor torque
Environment
Operating position Vertical +/- 10 degree
Product certifications CE
ATEX
NOM
GOST
EAC
RCM
KC
Marking CE
ATEX
UL
CSA
EAC
RCM
Standards IEC 61800-5-1
Electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to
IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Environmental class (during Class 3C3 according to IEC 60721-3-3
operation) Class 3S2 according to IEC 60721-3-3
Maximum acceleration under 150 m/s² at 11 ms
shock impact (during operation)
Maximum acceleration under 10 m/s² at 13...200 Hz
vibrational stress (during
operation)
Maximum deflection under 1.5 mm at 2...13 Hz
vibratory load (during operation)
Permitted relative humidity Class 3K5 according to EN 60721-3
(during operation)
30-May-2025 3
Volume of cooling air 60 m3/h
Overvoltage category III
Regulation loop Adjustable PID regulator
Speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn
pollution degree 2
Ambient air transport -25…70 °C
temperature
Ambient air temperature for -10…50 °C without derating
operation 50…60 °C with derating factor
Ambient air temperature for -25…70 °C
storage
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 19.500 cm
Package 1 Width 22.500 cm
Package 1 Length 33.000 cm
Package 1 Weight 4.696 kg
Unit Type of Package 2 P06
Number of Units in Package 2 10
Package 2 Height 75.000 cm
Package 2 Width 60.000 cm
Package 2 Length 80.000 cm
Package 2 Weight 57.500 kg
4 30-May-2025
Environmental Data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity
via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.
Environmental Data explained
How we assess product sustainability
Environmental footprint
Carbon footprint (kg.eq.CO2 per CR, Total Life cycle) 4080
Environmental Disclosure Product Environmental Profile
Use Better
Materials and Substances
Packaging made with recycled cardboard Yes
Packaging without single use plastic No
Pro-active compliance (Product out of EU RoHS legal
EU RoHS Directive
scope)
SCIP Number 14d809d0-5292-4a40-b69a-c03476cca11b
REACh Regulation REACh Declaration
Energy efficiency
Product contributes to saved and avoided emissions Yes
Use Again
Repack and remanufacture
Circularity Profile End of Life Information
Take-back No
The product must be disposed on European Union
WEEE markets following specific waste collection and never end
up in rubbish bins
30-May-2025 5
Product datasheet ATV320U55N4C
Dimensions Drawings
Right and Front Views without EMC Plate
Right and Front Views with EMC Plate
6 30-May-2025
Product datasheet ATV320U55N4C
Mounting and Clearance
Mounting Types
Mounting Type A: Individual with Ventilation Cover
Only Possible at Ambient Temperature Less or Equal to 50 °C (122 °F)
Mounting Type B: Side by Side, Ventilation Cover Removed
Mounting Type C: Individual, Ventilation Cover Removed
For Operation at Ambient Temperature Above 50 °C (122 °F)
30-May-2025 7
Product datasheet ATV320U55N4C
Connections and Schema
Connection Diagrams
Single or Three-phase Power Supply - Diagram With Line Contactor
(1) Line choke (if used)
(2) Use relay output R1 set to operating state Fault to switch Off the product once an error is detected.
Single or Three-phase Power Supply - Diagram With Downstream Contactor
(1) Line choke (if used)
(2) Use relay output R1 set to operating state Fault to switch Off the product once an error is detected.
8 30-May-2025
Product datasheet ATV320U55N4C
Control Block Wiring Diagram
(1) Analog output
(2) Analog inputs
(3) Potentiometer SZ1RV1202 (2.2 kΩ) or similar (10 kΩ maximum)
(4) Digital Inputs - Shielding instructions are given in the Electromagnetic Compatibility section
30-May-2025 9
Product datasheet ATV320U55N4C
Digital Inputs Wiring
Switch Set to SRC (Source) Position Using the Output Power Supply for the Digital Inputs
Switch Set to SRC (Source) Position and Use of an External Power Supply for the Digital Inputs
Switch Set to SK (Sink) Position Using the Output Power Supply for the Digital Inputs
Switch Set to EXT Position Using an External Power Supply for the Digital Inputs
NOTE :
• STO input is also connected by default on a 24 Vdc terminal. If the external power supply is switched off, the function
STO will be triggered.
• To avoid triggering the STO function when switching-on the product, the external power supply must be previously
switched on.
10 30-May-2025
Product datasheet ATV320U55N4C
30-May-2025 11
Product datasheet ATV320U55N4C
Performance Curves
Derating Curves
40 °C (104 °F) - Mounting type A, B and C
50 °C (122 °F) - Mounting type C
60 °C (122 °F) - Mounting type C
In : Nominal Drive Current
SF : Switching Frequency
12 30-May-2025
Product datasheet ATV320U55N4C
Technical Illustration
Dimensions
30-May-2025 13