SmartROC D65 MKII
System knowledge and
troubleshooting training
6. Electric system
6. Electric system
Electrical supply
• Overview of the electrical
components which are
needed to start the engine.
Confidential | © 2018 by Epiroc. All rights reserved. 2
Electric system
Emergency stops
Confidential | © 2018 by Epiroc. All rights reserved. 3
6. Electric system
Component location – CL
Power Pack Fuse Box
Rig left side KP
5
KP132-2
KP132
KP2
KP1
KP3
KP4
- Tier 4 Interim 9840042530
- Tier 4 Final 9840042599
Same components but different connections
Confidential | © 2018 by Epiroc. All rights reserved. 4
6. Electric system
Component location – T45/C50/CL
Rig left side
Batteries, fuse box
Confidential | © 2018 by Epiroc. All rights reserved. 5
6. Electric system
Component location
Touch
panel
connected
to Power
Board
PB Cover PDB
removed
Confidential | © 2018 by Epiroc. All rights reserved. 6
6. Electric system
Power distribution board
X20
K22
+B1
K05 K06 K07
X10
+B
K08 K09 K10 K11
K01 K02 K03 K0 GND
4 K21
K17 K18 K19 K20 X7
K12 K13 K14 K15 K16
X5 X6
F1 Fuses F23
X4 X3
F4
F2 4
4 X1 X2
Confidential | © 2018 by Epiroc. All rights reserved. 7
Relay K07
Refer to page 9,
coordinates 2B
Power distribution Board schematic
Confidential | © 2018 by Epiroc. All rights reserved. 8
2
B Power
Distribution
Board X5
Contact
Contacts of the continue on
relay page
10-7/C
Power distribution Board schematic
Confidential | © 2018 by Epiroc. All rights reserved. 9
6. Electric system
Typical problems
Problem Reason Action to take Important! The list below is
only a summary of the MOST
The most common one is typical causes of the problems.
Safety edge relay K70 Check all emergency stops, bypass
Emergency stop warning in Do not forget to consider all
(controlling the emergency stop emergency stops > k70 & k71 >
display, can’t reset. bars) broken. K22 to identify the broken relay.
aspects during troubleshooting!
But can also be K71 or K22.
Ensure that the system has coolant gas.
The air conditioning is not The low pressure switch is Make sure that the switch closes to send
working damaged the signal to the compressor. If the switch
does not close, replace it.
Check that the belt is in good condition.
Check that the voltage is maintained at
The alternator was not approximately 27V. Check that the voltage is
There is no cranking charging, battery is empty. maintained at approximately 27V. If the
voltage drops below 22V change the
alternator.
Confidential | © 2018 by Epiroc. All rights reserved. 10