III-73-GW427-396-01 Anodic Protection Arrangement and Calculation (Ballast Tanks)

The document outlines the anodic protection arrangement and calculations for a 1700 TEU container vessel, specifically focusing on water ballast tanks. It details the specifications for aluminum-zinc-indium-tin alloy anodes, including their size, weight, and potential, as well as calculations for produced current and useful life. Additionally, it provides a breakdown of the protected areas and the number of anodes required for various ballast tanks.

Uploaded by

sinhnt5382
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
34 views5 pages

III-73-GW427-396-01 Anodic Protection Arrangement and Calculation (Ballast Tanks)

The document outlines the anodic protection arrangement and calculations for a 1700 TEU container vessel, specifically focusing on water ballast tanks. It details the specifications for aluminum-zinc-indium-tin alloy anodes, including their size, weight, and potential, as well as calculations for produced current and useful life. Additionally, it provides a breakdown of the protected areas and the number of anodes required for various ballast tanks.

Uploaded by

sinhnt5382
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Sign

1700TEU.N FINISHED DESIGN


CONTAINER VESSEL
Mark Qty Cor. Sheet Sign Date GW427-396-01
Compose Huang Tianxing Typist Anodic Protection
Checked Yuan Yuren Type Chk. Arrangement and 2
Area 0.1875 m Page 1 /5
Verified
Calculation GUANGZHOU
Std. Chk. WENCHONG SHIPYARD
Approved Date 2010.9.19 (Ballast tanks) CO. LTD.
ANODIC PROTECTION ARRANGEMENT AND GW427-396-01 PAGE
CALCULATION (Rudder & Sea chests) 2

I ANODE FOR WATER BALLAST TANKS

1 Anodes for water ballast tanks shall be Al-Zn-In-Sn alloy anodes


a) Size:
(B1 + B2) × L × H = (115 + 135) × 300 × 140 mm
b) Weight:
m = 13.5 kg
c) Open potential: -1.18V ~ -1.10V
d) Working potential: -1.12V ~ -1.05V
e) Practical current capacity: Q = 2400 A⋅h/kg
Impurity,less than
Element(%) Zn In Sn Al
Si Fe Cu
content 2.2~5.2 0.02~0.045 0.018~0.035 0.1 0.15 0.01 rest

2 Produced current If calculation


If = ΔE / R
where: ΔE — Driving voltage for aluminum anode, ΔE = 0.25 V
R — Water connection resistance of anode for slender anode, Ω
⎡ ⎧ 2 ⎞⎫ 2⎤
ρ ⎢ ⎪ 2L ⎛⎜ ⎛ r ⎞ ⎟⎪ r ⎛ r ⎞ ⎥
R= Ln⎨ 1+ 1+ ⎜ ⎟ ⎬ + − 1+ ⎜ ⎟ (L < 4r)
2πL ⎢ ⎪ r ⎜ ⎝ 2L ⎠ ⎟⎪ 2L ⎝ 2L ⎠ ⎥
⎣ ⎩ ⎝ ⎠⎭ ⎦
where: ρ — Resistivity of sea water, ρ = 25 Ω⋅cm
L — Length of anode, L = 30 cm
r — Radius of anode for other than cylindrical shapes, cm
C
r=

where: C — Cross section perimeter
C = 11.5 + 13.5 + 14.0 × 2 = 53.0 cm
C 53.0
so: r = = = 8.44 cm (L < 4r)
2π 2π
⎡ ⎧ 2 ⎫ 2⎤
25 ⎢ ⎪ 2 × 30 ⎛⎜ ⎛ 8.44 ⎞ ⎞⎟⎪ 8.44 ⎛ 8.44 ⎞ ⎥
R= × Ln ⎨ 1+ 1+ ⎜ ⎟ ⎬+ − 1+ ⎜ ⎟
2 × π × 30 ⎢ ⎪ 8.44 ⎜ ⎝ 2 × 30 ⎠ ⎟⎪ 2 × 30 ⎝ 2 × 30 ⎠ ⎥
⎣ ⎩ ⎝ ⎠⎭ ⎦
= 0.2375Ω

If = ΔE / R1 = 0.25 / 0.2375 = 1.0526 A = 1052.6 mA

3 Useful Life t calculation


m ⋅ Q × 1000 1
t= ⋅
Im × 8760 K
where: m — Weight of anode, m = 13.5 kg
Q — Capacity of anode, Q = 2400 A⋅h/kg
Im — Average producted current of anode, mA
Im = 0.6 × If =0.6× 1052.6 = 631.6 mA
1 1
— Using rate of anode, = 0.85
K K
ANODIC PROTECTION ARRANGEMENT AND GW427-396-01 PAGE
CALCULATION (Rudder & Sea chests) 3

13.5 × 2400 × 1000


so: t = × 0.85 = 4.978 ≈ 5 years
631.6 × 8760
It is satisfied with the requirement of 5 years useful life in the Specifications.
4 Protected Area and number of anode required for water ballast tank calculation
ij ⋅ S
Ni =
j

If
where: Ni — Number of anode for protected area
ij — Protective current density, according to the Shipyard’s standard,
ij = 10 mA/m2
Sj — Soggy area, m2
lf — Produced current, mA
So protected area and number of anode required for water ballast tank shall be as
follows:
Protected Number of anodes
No Name of tanks Area
(115+135)×300×140
(m2)
1 F. P. T. 2396 25
No.1 DB W.B.T
2 2851 28
(FR.164~FR.203).
3 No.1 SIDE W.B.T. (P) 2004 22
4 No.1 SIDE W.B.T. (S) 2004 22
5 No.2 DB W.B.T. (P) 1207 12
6 No.2 DB W.B.T. (S) 1207 12
7 No.2 SIDE W.B.T. (P) 846 9
8 No.2 SIDE W.B.T. (S) 936 10
9 No.4 DB W.B.T. (P) 1834 18
10 No.4 DB W.B.T. (S) 1834 18
11 No.4 SIDE W.B.T. (P) 1802.7 18
12 No.4 SIDE W.B.T. (S) 1802.7 18
13 No.5 DB W.B.T. (P) 1435 14
14 No.5 DB W.B.T. (S) 1435 14
15 No.5 SIDE W.B.T. (P) 1542 16
16 No.5 SIDE W.B.T. (S) 1542 16
17 No.7 DB W.B.T 811 8
18 No.7 SIDE W.B.T. (P) 440 5
19 No.7 SIDE W.B.T. (S) 440 5
20 A. P. T. 1792 18
21 Total 29916 308