0% found this document useful (0 votes)
72 views12 pages

Schneider Electric Altivar-Machine-ATV320 ATV320U15M2C

The document provides a comprehensive datasheet for the Altivar Machine ATV320 variable speed drive, detailing its specifications, features, and environmental data. It includes information on electrical ratings, input/output configurations, safety functions, and compliance with various standards. Additionally, it outlines the product's sustainability efforts and packaging materials used.

Uploaded by

myeasyway102
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
72 views12 pages

Schneider Electric Altivar-Machine-ATV320 ATV320U15M2C

The document provides a comprehensive datasheet for the Altivar Machine ATV320 variable speed drive, detailing its specifications, features, and environmental data. It includes information on electrical ratings, input/output configurations, safety functions, and compliance with various standards. Additionally, it outlines the product's sustainability efforts and packaging materials used.

Uploaded by

myeasyway102
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

Product datasheet

Specifications

variable speed drive, Altivar


Machine ATV320, 1.5kW, 200 to
240V, 1 phase, compact
ATV320U15M2C

Main
Range of product Altivar Machine ATV320

Product or component type Variable speed drive

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Product specific application Complex machines

Variant Standard version

Format of the drive Compact

Mounting mode Wall mount

Communication port protocol Modbus serial


CANopen

Option card Communication module, CANopen


Communication module, EtherCAT
Communication module, Profibus DP V1
Communication module, PROFINET
Communication module, Ethernet Powerlink
Communication module, EtherNet/IP
Communication module, DeviceNet

[Us] rated supply voltage 200...240 V - 15...10 %

nominal output current 8.0 A

Motor power kW 1.5 kW for heavy duty

EMC filter Class C2 EMC filter integrated

IP degree of protection IP20

Complementary
Discrete input number 7

Discrete input type STO safe torque off, 24 V DC, impedance: 1.5 kOhm
DI1...DI6 logic inputs, 24 V DC (30 V)
DI5 programmable as pulse input: 0…30 kHz, 24 V DC (30 V)

Discrete input logic Positive logic (source)


Negative logic (sink)

Discrete output number 3

Discrete output type Open collector DQ+ 0…1 kHz 30 V DC 100 mA


Open collector DQ- 0…1 kHz 30 V DC 100 mA

Analogue input number 3

Analogue input type AI1 voltage: 0...10 V DC, impedance: 30 kOhm, resolution 10 bits
AI2 bipolar differential voltage: +/- 10 V DC, impedance: 30 kOhm, resolution 10 bits
AI3 current: 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by
configuration), impedance: 250 Ohm, resolution 10 bits

Analogue output number 1

Apr 27, 2025 1


AD
Analogue output type Software-configurable current AQ1: 0...20 mA impedance 800 Ohm, resolution 10
bits
Software-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm, resolution 10
bits

Relay output type Configurable relay logic R1A 1 NO electrical durability 100000 cycles
Configurable relay logic R1B 1 NC electrical durability 100000 cycles
Configurable relay logic R1C
Configurable relay logic R2A 1 NO electrical durability 100000 cycles
Configurable relay logic R2C

Maximum switching current Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7
ms: 2 A at 250 V AC
Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7
ms: 2 A at 30 V DC
Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 250 V AC
Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 30 V DC

Minimum switching current Relay output R1A, R1B, R1C, R2A, R2C: 5 mA at 24 V DC

Method of access Slave CANopen

4 quadrant operation possible True

Asynchronous motor control Voltage/frequency ratio, 5 points


profile Flux vector control without sensor, standard
Voltage/frequency ratio - Energy Saving, quadratic U/f
Flux vector control without sensor - Energy Saving
Voltage/frequency ratio, 2 points

Synchronous motor control profile Vector control without sensor

Maximum output frequency 0.599 kHz

Acceleration and deceleration Linear


ramps U
S
CUS
Ramp switching
Acceleration/deceleration ramp adaptation
Acceleration/deceleration automatic stop with DC injection

Motor slip compensation Automatic whatever the load


Adjustable 0...300 %
Not available in voltage/frequency ratio (2 or 5 points)

Switching frequency 2...16 kHz adjustable


4...16 kHz with derating factor

Nominal switching frequency 4 kHz

Braking to standstill By DC injection

Brake chopper integrated True

Line current 17.8 A at 200 V (heavy duty)


14.9 A at 240 V (heavy duty)

Maximum input current 17.8 A

Maximum output voltage 240 V

Apparent power 3.6 kVA at 240 V (heavy duty)

Network frequency 50...60 Hz

Relative symmetric network 5%


frequency tolerance
Prospective line Isc 1 kA

Base load current at high 4.8 A


overload
Power dissipation in W Fan: 76.0 W at 200 V, switching frequency 4 kHz

With safety function Safely True


Limited Speed (SLS)
With safety function Safe brake False
management (SBC/SBT)

2 Apr 27, 2025


AD
With safety function Safe False
Operating Stop (SOS)
With safety function Safe Position False
(SP)
With safety function Safe False
programmable logic
With safety function Safe Speed False
Monitor (SSM)
With safety function Safe Stop 1 True
(SS1)
With sft fct Safe Stop 2 (SS2) False

With safety function Safe torque True


off (STO)
With safety function Safely False
Limited Position (SLP)
With safety function Safe False
Direction (SDI)
Protection type Input phase breaks: drive
Overcurrent between output phases and earth: drive
Overheating protection: drive
Short-circuit between motor phases: drive
Thermal protection: drive

Width 105.0 mm

Height 142.0 mm

Depth 158.0 mm

Net weight 1.6 kg

Transient overtorque 170…200 % of nominal motor torque

Environment
Operating position Vertical +/- 10 degree

Product certifications CE
ATEX
NOM
GOST
EAC
RCM
KC

Marking CE
ATEX
UL
CSA
EAC
RCM

Standards IEC 61800-5-1

Electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to
IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11

Environmental class (during Class 3C3 according to IEC 60721-3-3


operation) Class 3S2 according to IEC 60721-3-3

Maximum acceleration under 150 m/s² at 11 ms


shock impact (during operation)
Maximum acceleration under 10 m/s² at 13...200 Hz
vibrational stress (during
operation)
Maximum deflection under 1.5 mm at 2...13 Hz
vibratory load (during operation)
Permitted relative humidity Class 3K5 according to EN 60721-3
(during operation)

Apr 27, 2025 3


AD
Volume of cooling air 16.0 m3/h

Overvoltage category III

Regulation loop Adjustable PID regulator

Speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn

pollution degree 2

Ambient air transport -25…70 °C


temperature
Ambient air temperature for -10…50 °C without derating
operation 50…60 °C with derating factor

Ambient air temperature for -25…70 °C


storage

Packing Units
Unit Type of Package 1 PCE

Number of Units in Package 1 1

Package 1 Height 18.100 cm

Package 1 Width 18.700 cm

Package 1 Length 18.700 cm

Package 1 Weight 1.837 kg

Unit Type of Package 2 S06

Number of Units in Package 2 30

Package 2 Height 75.000 cm

Package 2 Width 60.000 cm

Package 2 Length 80.000 cm

Package 2 Weight 69.400 kg

4 Apr 27, 2025


AD
Environmental Data

Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity
via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.

Environmental Data explained

How we assess product sustainability

Environmental footprint

Carbon footprint (kg.eq.CO2 per CR, Total Life cycle) 1663

Environmental Disclosure Product Environmental Profile

Use Better

Materials and Substances

Packaging made with recycled cardboard Yes

Packaging without single use plastic Yes

Pro-active compliance (Product out of EU RoHS legal


EU RoHS Directive
scope)

SCIP Number C0283eca-aee5-4ec9-9f8c-c7e056d0a8d7

REACh Regulation REACh Declaration

Energy efficiency

Product contributes to saved and avoided emissions Yes

Use Again

Repack and remanufacture

Take-back No

The product must be disposed on European Union


WEEE markets following specific waste collection and never end
up in rubbish bins

Apr 27, 2025 5


AD
Product datasheet ATV320U15M2C

Dimensions Drawings

Dimensions

Right View, Front View and Front View with EMC Plate

6 Apr 27, 2025


AD
Product datasheet ATV320U15M2C

Mounting and Clearance

Mounting Types

Mounting Type A: Individual with Ventilation Cover

Only Possible at Ambient Temperature Less or Equal to 50 °C (122 °F)

Mounting Type B: Side by Side, Ventilation Cover Removed

Mounting Type C: Individual, Ventilation Cover Removed

For Operation at Ambient Temperature Above 50 °C (122 °F)

Apr 27, 2025 7


AD
Product datasheet ATV320U15M2C

Connections and Schema

Connection Diagrams

Single or Three-phase Power Supply - Diagram With Line Contactor

(1) Line choke (if used)


(2) Use relay output R1 set to operating state Fault to switch Off the product once an error is detected.

Single or Three-phase Power Supply - Diagram With Downstream Contactor

(1) Line choke (if used)


(2) Use relay output R1 set to operating state Fault to switch Off the product once an error is detected.

8 Apr 27, 2025


AD
Product datasheet ATV320U15M2C

Control Block Wiring Diagram

(1) Analog output


(2) Analog inputs
(3) Potentiometer SZ1RV1202 (2.2 kΩ) or similar (10 kΩ maximum)
(4) Digital Inputs - Shielding instructions are given in the Electromagnetic Compatibility section

Apr 27, 2025 9


AD
Product datasheet ATV320U15M2C

Digital Inputs Wiring

Switch Set to SRC (Source) Position Using the Output Power Supply for the Digital Inputs

Switch Set to SRC (Source) Position and Use of an External Power Supply for the Digital Inputs

Switch Set to SK (Sink) Position Using the Output Power Supply for the Digital Inputs

Switch Set to EXT Position Using an External Power Supply for the Digital Inputs

NOTE :
• STO input is also connected by default on a 24 Vdc terminal. If the external power supply is switched off, the function
STO will be triggered.
• To avoid triggering the STO function when switching-on the product, the external power supply must be previously
switched on.

10 Apr 27, 2025


AD
Product datasheet ATV320U15M2C

Apr 27, 2025 11


AD
Product datasheet ATV320U15M2C

Performance Curves

Derating Curves

40 °C (104 °F) - Mounting type A, B and C


50 °C (122 °F) - Mounting type C
60 °C (140 °F) - Mounting type C
In : Nominal Drive Current
SF : Switching Frequency

12 Apr 27, 2025


AD

You might also like