0% found this document useful (0 votes)
12 views8 pages

ST Triplus t02200002 gb2238

The Valsir Triplus® system is designed for high and low temperature waste systems, ventilation, and rainwater drainage in various buildings. It features excellent sound insulation, watertight joints, and is easy to install with a wide range of diameters and chemical resistance. The system meets EN 1451 standards and is suitable for both indoor and outdoor applications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
12 views8 pages

ST Triplus t02200002 gb2238

The Valsir Triplus® system is designed for high and low temperature waste systems, ventilation, and rainwater drainage in various buildings. It features excellent sound insulation, watertight joints, and is easy to install with a wide range of diameters and chemical resistance. The system meets EN 1451 standards and is suitable for both indoor and outdoor applications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

TECHNICAL

DATA SHEET
VALSIR® WASTE SYSTEMS

TRIPLUS
The product
The Valsir Triplus® system is suitable for the construction
of high and low temperature waste systems, for the
ventilation of waste systems and for rainwater drainage
inside civil and industrial buildings, hospitals, hotels,
etc.

Thanks to its mechanical resistance the system is also


suitable for use in central dust collection systems.
The pipes are composed of three layers of material,
which, when put together, give the pipes high
mechanical characteristics at low temperatures and an
excellent soundproofing performance.

Characteristics
• Excellent sound insulation performance; the system reduces noise to just 12 dB(A) with a flow of 2 l/s.
• Absolute guarantee of watertight joints, thanks to the elastomeric seal (factory fitted), that do not require the use
of any special tools, glues or solvents.
• Extremely fast and easy to install thanks to the light weight of the products.
• Wide range of diameters from OD 32 mm to OD 250 mm and the availability of transition accessories for
connection to existing waste systems in different materials such as cast iron, PE, PVC, etc.
• Excellent impact resistance even at low temperatures thanks to the triple-layer structure.
• High resistance to a wide range of chemical compounds also at high temperatures; not affected by stray
currents.
• An high abrasion resistance and extremely smooth internal surfaces guarantee minimal pressure losses and no
deposit formation.
• Pipes are available in various lengths (from 150 mm to 3 m) and by using the dual socketed pipes and fittings
(sliding double socket) material wastage is avoided.

Figure Layering of the pipe.


Push-fit socket with lip seal
The push-fit socket with lip seal guarantees water tightness and
allows movement of the pipe due to thermal expansion.
The geometric characteristics of the socket ensure installation
Intermediate layer speed and simplicity.
Obtained with a mix of polypropylene and mineral fillers
that guarantees elevated mechanical resistance and
excellent soundproofing performance.

Exterior layer Interior layer


Produced in polypropylene, guarantees The inside of the pipe is made of a layer in polypropylene that
elevated impact resistance and excellent results in an extremely smooth internal surface and a high
mechanical protection. resistance to chemical agents.
Technical details
Table Typical technical details.

Property Value Test method


Homopolymer polypropylene for the internal and external layers,
Pipe material -
mix of polypropylene and mineral loads for the intermediate layer
Fitting material Homopolymer polypropylene + mineral charges -
Seal material SBR rubber
Fittings: Light blue RAL 5015.
Colour Pipes: Light blue RAL 5015 for the internal and external layers, -
Black for the intermediate layer.
Sizes 32÷250 mm -
High and low temperature waste and drainage systems inside
the building or anchored externally to the walls of the building
Application -
(application area B) or laid directly in concrete; ventilation of
waste systems; gravity rainwater drainage systems.
Connections Push-fit socket connection with rubber seal. -
Minimum temperature of use -25°C -
Maximum temperature +95°C (intermittent)
-
of waste water +80°C (continuous)
Minimum pressure -800 mbar(1) -
Maximum pressure +1.5 bar(2) -
Composition of waste water pH 2÷12 -
LSC,A=12 dB(A) with flow of 2 l/s, measurement performed on
EN 14366
ground floor, behind the installation wall with 2 clips per floor
LIN=15 dB(A) with flow of 2 l/s, measurement performed on
DIN 4109
Soundproofing performance((3) ground floor, behind the installation wall with 2 clips per floor
Rw + Ctr 42 without pipe cladding and with 13 mm plasterboard
Building Code of Australia
wall and 75 mm R1.5 insulation, evaluation made with flow of 2
(Part F5.6)
and 4 l/s.
pipes: > 1200 kg/m3 (medium thickness)
Density at 23°C > 1800 kg/m3 (intermediate layer) EN ISO 1183-2
fittings: > 1400 kg/m3
Melt Index 230/2.16 < 5.0 g/10 min EN ISO 1133
Elasticity modulus 1500 MPa ISO 527-2
Tensile strength ≥ 18 MPa ISO 527-2
Ultimate elongation ≥ 600% ISO 6259-3
Crystalline melting temperature ≥ 160°C EN 728
Linear heat expansion coefficient 0.08 mm/m·K -
Suitable for use outdoors . Suitable to be stored outdoors
(4)
UV resistance -
(for periods not exceeding 18 months).
Halogen content Halogen-free -
Fire resistance Euroclass D-s3,d0 EN 13501-1
Reference construction standard EN 1451-1 - AS7671:2003 - DIBt z42.1-426 -
Pipes in wooden frames with strapping for large diameters,
in bundles tied with plastic elements for other diameters, in
Packaging -
cardboard boxes for small diameters and reduced lengths.
Fittings in cardboard boxes

(1) The system is suitable for the creation of collection systems and vacuum waste systems. The values indicated refer to 20°C.
(2) The system is suitable for gravity waste and drainage systems, the value indicated refers therefore to the maximum pressure that can applied during
system testing at 20°C.
(3) For greater detail refer to chapter 2 “Noise in waste systems”.
(4) Provided protected from direct sunlight, for example, using a special protective paint.
Application field
The Valsir Triplus® pipes and fittings meet the requirements of the EN 1451 Standard and can be used inside
buildings for residential and industrial use and in particular for the following applications:
a) Waste systems for transporting domestic waste waters (low and high temperature).
b) Ventilation pipes connected to the waste systems previously indicated.
c) Rain water systems inside the structure of the building.

Followings in the European Standard EN 1451 the Valsir Triplus® pipes are suitable for applications identified with
the “B” marking that identifies pipes and fittings for use inside the building or outside, anchored to a wall.

Dimensions
The diameters, the wall thickness and the relative tolerances of the Valsir Triplus® pipes are indicated in the
following table.

Table Pipe dimensional characteristics.

Nominal diameter External diameter Thickness Series S Application area


DN [mm] OD [mm] s [mm]
30 32 +00.3 1.8 +00.4 16 B

40 40 +00.3 1.8 +00.4 16 B


+0.3 +0.4
50 50 0 1.8 0 16 B

70 75 +00.4 2.6 +00.5 14 B

90 90 +00.4 3.1 +00.6 14 B


+0.4 +0.6
100 110 0 3.4 0 16 B

125 125 +00.4 3.9 +00.6 16 B


+0.5 +0.7
150 160 0 4.9 0 16 B

200 200 +00.5 6.2 +00.6 16 B

250 250 +00.5 7.7 +00.8 16 B

Note: The tolerances indicated are specified in the reference standard EN 1451.

Connection systems
Different methods can be used for connecting the pipes and/or fittings:
• Connection with push-fit socket.
• Connection with sliding sleeve.

Approvals:
The approvals of Valsir® waste systems are available on the website: www.valsir.com
Marking
Figure Pipe marking.
Indication of
Name of External diameter application area Product
manufacturer and thickness Indication of approvals
(B) and series
production plant

Brand name (Triplus) Indication of material Reference Indication of


(PP/PP-M/PP) standard production period

Figure Fitting marking.


Nome
Marchio del commerciale
fabbricante Triplus Identificazione del
Diametri di materiale (PP-M)
accoppiamento
TRIPLUS PP-M
HTEA DN 75-75 X 45° Angolo caratteristico
(per le curve e le derivazioni)
Riferimento EN 1451 -B-
normativo
Indicazione area
di applicazione (B)
Marchi di prodotto
Acoustic performance: the test methods
The reference standards used for the tests are UNI EN 14366:2004 and DIN 4109:1989 (together with DIN
52219:1993) that specify the measurement methods and the evaluation of the results. The test building is made
up of a completely insulated room with thick walls made of a sound absorbing material of high quality.
It is a real buildings with four floors (with an internal height of 3050 mm), two of which, indicated in the figure as
EG and UG, are the reference floors for noise detection divided by a wall made of concrete with a weight of 220
kg/m2 (250 kg/m2 for the European Standard UNI EN 14366) to which a waste stack is anchored.
The measurement floors are each divided into two rooms: the front room is where the pipe is installed, the back
room contains no installation and picks up the noise vibrations transferred to the partition wall; the back rooms
have a volume of 70.4 m3 (surface area of about 23 m2) while the front rooms are 52.6 m3 (surface area of about
17 m2).

Partition wall

DG
Celling

EG EG
Ground floor Ground floor
rear front

UG UG
Underground Underground
floor rear floor front

KG
Cellar

The waste flow (continuous) is ensured by means of a pumping station that guarantees a precision of 5% and
which supplies different levels of flow in relation to the internal diameter of the pipe as can be seen in Table 2.7
The acoustic pressure levels are measured in third octaves with frequencies from 100 Hz to 5000 Hz.

Measurement flow in relation to the dimensions of the waste pipe to be tested.


Internal diameter of the pipe [mm] 70 ≤ Di < 100 100 ≤ Di < 125 125 ≤ Di < 150
Measurement flows [l/s] 0.5 - 1 0.5 - 1 - 2 - 4 0.5 - 1 - 2 - 4 - 8
The acoustic results
The testing campaign involved numerous tests being carried out in 1997, 1998, 2004, 2006 and 2014 and the
excellent results obtained following the development of the Valsir® waste systems are indicated in the diagrams
and tables which follow. The tests were carried out both with 2 clips per floor and with 1 clip per floor as the latter
represents the typical installation configuration in residential buildings. Consider that the values obtained were
rounded up to whole numbers as requested by the reference standards.

Table Levels of sound pressure measured behind the installation wall for the Valsir Triplus® 110x3.6 pipe, measurements
performed and formulated by the Fraunhofer Institute of Stuttgart (Germany).

Test pipes: Valsir Triplus®


Flow rate of water
Reference
Measurement 0.5 l/s
Test conditions 1 l/s 2 l/s 4 l/s standard
floor (Certificate)(b)
Sound level
Index LSC,A measured behind the installation wall,
UG 1 dB(A) 6 dB(A) 12 dB(A) 16 dB(A) EN 14366
with 2 clips per floor, pipe diameter OD 110 mm

Index LIN measured behind the installation wall, EG 3 dB(A) 8 dB(A) 12 dB(A) 19 dB(A)
DIN 4109
with 2 clips per floor, pipe diameter OD 110 mm UG 4 dB(A) 9 dB(A) 15 dB(A) 19 dB(A)

Index LIN measured behind the installation wall, EG 1 dB(A) 5 dB(A) 10 dB(A) 16 dB(A)
DIN 4109
with 1 clip per floor, pipe diameter OD 110 mm UG 2 dB(A) 6 dB(A) 11 dB(A) 15 dB(A)
PLUMBING
WASTE SYSTEMS

SUPPLY SYSTEMS

GAS SYSTEMS

FLUSH SYSTEMS

BATHROOM SYSTEMS

TRAPS

RADIANT SYSTEMS

DRAINAGE SYSTEMS

HRV SYSTEM

ACADEMY
BUILDING

SEWER SYSTEMS

WATER TREATMENT

VALSIR S.p.A.
T02-200/2 - Dicembre 2018

Località Merlaro, 2
25078 Vestone (BS) - Italy
Tel. +39 0365 877.011
Fax +39 0365 81.268
e-mail: [email protected]
www.valsir.com
Soggetta all’attività di direzione e coordinamento ex art. 2497 bis C.C.
da parte di Silmar Group S.p.A. - Codice Fiscale 02075160172

You might also like