0% found this document useful (0 votes)
225 views43 pages

H3 GUI Manual

Manual may not be copied or reproduced in any manner without prior written permission of Tanisys Technology, Inc.

Uploaded by

phat_trc
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
225 views43 pages

H3 GUI Manual

Manual may not be copied or reproduced in any manner without prior written permission of Tanisys Technology, Inc.

Uploaded by

phat_trc
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 43

Tanisys M550 Users Manual

H3 Graphical User Interface OPERATIONS MANUAL


August 2010

Copyright 2010, 2011 Tanisys Technology, Inc. All rights reserved. Test software and menu screens are protected by copyright under applicable laws. This manual may not be copied or reproduced in any manner without prior written permission of Tanisys Technology, Inc. The Tanisys logo is a registered trademark of Tanisys Technology, Inc. DNA2 is a trademark of Tanisys Technology, Inc. Other brand and product names are trademarks of their respective holders

This page has been left intentionally blank.

H3 GUI OPERATIONS MANUAL

Table of Contents
Chapter 1: Introduction__________________________________________________ 5 1.1 Use of this document __________________________________________________ 5 1.2 Document Conventions ________________________________________________ 6 Chapter 2: Quick Start Guide _____________________________________________ 7 2.1 Starting the Hardware _________________________________________________ 7 2.2 Starting the H3 GUI ___________________________________________________ 7 2.3 Loading and Running a Recipe __________________________________________ 9 2.3.1 Change the User Privilege _________________________________________ 9 2.3.2 Lock the HW Core board or Sub-Chassis component or Chassis __________ 10 2.3.3 Load an XML Recipe file _________________________________________ 11 2.3.4 Run the desired Recipe __________________________________________ 13 Chapter 3: H3 GUI Comprehensive Usage _________________________________ 16 3.1 File Menu __________________________________________________________ 16 3.1.1 Load Recipe _________________________________________________ 16 3.1.2 New Recipe ___________________________________________________ 17 3.1.3 Save Recipe ___________________________________________________ 24 3.1.4 Save Recipe As ______________________________________________ 25 3.1.5 Close Recipe __________________________________________________ 25 3.1.6 Exit __________________________________________________________ 25 3.2 View Menu _________________________________________________________ 26 3.2.1 Refresh Blades_________________________________________________ 26 3.2.2 DUT Display ___________________________________________________ 27 3.2.3 Recipe _______________________________________________________ 28 3.2.4 Log __________________________________________________________ 29 3.2.5 Real Time Statistics _____________________________________________ 31 3.2.6 Blades _______________________________________________________ 32 3.3 Lot Management Menu _______________________________________________ 33 3.4 Tools Menu ________________________________________________________ 33 3.4.1 Change Privilege _______________________________________________ 34 3.4.2 Start Custom Front End __________________________________________ 35 3.4.3 Reset Real Time Monitor _________________________________________ 35 3.4.4 Run Tests _____________________________________________________ 36 3.4.5 GPIB Settings ________________________________________________ 36 3.4.6 Options _____________________________________________________ 37 3.4.7 Load Hifix Configuration __________________________________________ 38 3.5 Help ______________________________________________________________ 39 Chapter 4: Contact Information __________________________________________ 40

Table of Contents

H3 GUI OPERATIONS MANUAL


4.1 Technical Support ___________________________________________________ 40 4.2 Corporate Offices: ___________________________________________________ 40 4.3 Global Field Sales / Support Offices: _____________________________________ 40 Appendix A: Glossary ____________________________________________________ 41

Table of Contents

H3 GUI OPERATIONS MANUAL

Chapter 1: Introduction
The goal of this manual is to enable operators to utilize the H3 Graphical User Interface (GUI).

1.1 Use of this document


Thank you for choosing to use the H3 Graphical User Interface on a Tanisys Test System Platform. The development team at Tanisys is proud to provide you, our customer, with some of the most advanced tools available to develop sophisticated test programs on a Tanisys Test Platform. This document contains the information needed to utilize the H3 Graphical User Interface.

Chapter 1: Introduction

H3 GUI OPERATIONS MANUAL

1.2 Document Conventions


The table below outlines the conventions used in this documentation. Item Convention Example Acronyms
Book titles Code example Commands on menus and buttons Constants Device Names Dialog-box titles Dialog- box options Directories Environment variables Extensions (file) File names Folders Functions and methods Icon names Uppercase Italic Monospace Bold Bold Uppercase Bold Bold Bold Uppercase Bold Bold Bold Bold Title caps CS, DRAM The Hardware Reference #include . . . Run Test . . . cm_per_inch COM1, AUX port Parallel PD Bit Setup Read, OK DNA2\R1.10\Tester INCLUDE anyFile.t2s the Constants.t2s file the Recipes folder KnotsToMiles function Accessories icon Ctrl, Ctrl+Alt+Del typedef

Key names, combinations, and Bold sequences, title caps Keywords (of language or operating system) Links Logical keys Logical operators Macros Menu names (in Windows) New terms Operators Placeholders Programs Registers User input Variables Bold Underscore and blue. Title caps Bold, uppercase Bold Bold, title caps Italic Bold Italic Title caps (or as used by producer) Uppercase Italic Italic

Documentation Links
Insert Field key AND, OR LOWORD File menu The handler +, Type the password. Visio REGS registers Type -cCutoff the lineno variable

Chapter 1: Introduction

H3 GUI OPERATIONS MANUAL

Chapter 2: Quick Start Guide


The H3 GUI will be installed in a Windows based Desktop Controller PC. The program and all subcomponents will be pre-installed, so the user will have the opportunity to start the use of the H3 GUI very quickly. If Tanisys Software is not pre-installed on the Desktop Controller PC, a soft copy of it will be available on both a CD and on the Tanisys FTP site (206.127.28.196). For the latter case, instructions for Tanisys Software retrieval and installation procedure will be made available separately.

2.1 Starting the Hardware


The preferred process, for running Tanisys Test Systems, is to turn on the HW first. The user should switch on the Tester Chassis by lifting up a Power switch or pressing a button. Once the HW is on for 5 to 10 minutes depending on specific systems, then one can start the use of the H3 GUI on the Desktop Controller PC.

2.2 Starting the H3 GUI


To get the H3 GUI started, please either double click the Desktop Icon labeled H3. The Desktop Icon looks like the one shown below.

H3 GUI Desktop Icon An alternative way of starting the H3 GUI is to go to: Start button Programs Tanisys Technology H3

Chapter 2: Quick Start Guide

H3 GUI OPERATIONS MANUAL


As the H3 GUI is loading the splash display below will pop up and then disappear when the H3 GUI has fully loaded.

H3 GUI start up splash pop up Once the H3 GUI has fully loaded the window below will appear.

H3 GUI after its fully loaded

Chapter 2: Quick Start Guide

H3 GUI OPERATIONS MANUAL

2.3 Loading and Running a Recipe


To run any test on the H3 GUI, one needs to load a Recipe. In order to load a Recipe on the GUI, there are a number of steps that need to be taken. These are: Change the User Privilege Lock the Hardware (HW) Core board or Sub-Chassis component or Chassis Load an XML Recipe file Run the desired Recipe Please find the following sub-chapters describing this process

2.3.1

Change the User Privilege

The default Privilege level of the H3 GUI is Basic. The next set of instructions is based on that fact. If the Privilege level has been previously set to either Tech or Expert then this Section may be skipped. Under the Tools menu option, one can find an option called Change Privilege, under which all Privilege levels reside.

Illustration of how to change the privilege level

Chapter 2: Quick Start Guide

H3 GUI OPERATIONS MANUAL


Once the user clicks on either Tech or Expert, then the user must know and input the required password for this access level. Tanisys Technology Inc provides these separately to the appropriate level staff. The different user levels allow access control of features that can be altered within the H3 GUI. The Expert user has full access.

Change Privilege Screen

2.3.2

Lock the HW Core board or Sub-Chassis component or Chassis

The user must Lock the HW to initiate communication between the HW and the H3 GUI. To do so, one must right click on either: the HW Core Board (called the Blade in many cases) the Sub-Chassis component (called Bay in many cases) the Chassis The following figure illustrates how to Lock the HW Core Board.

Locking the HW Core Board or Blade in this particular case

Chapter 2: Quick Start Guide

10

H3 GUI OPERATIONS MANUAL


2.3.3 Load an XML Recipe file

To load a recipe file the user may do so one of three ways. These are: Press F3 on the keyboard Go to File Load Recipe Click on folder button on the GUI The last two are illustrated below.

Opening Recipe from File menu

Opening Recipe via Folder button

Chapter 2: Quick Start Guide

11

H3 GUI OPERATIONS MANUAL


Once one of those three methods is used to open a recipe, the window shown below will appear and the user must select a desired recipe. Usually recipe files have an .xml extension.

Window showing recipe files to open

Chapter 2: Quick Start Guide

12

H3 GUI OPERATIONS MANUAL


Once a recipe is opened, the XML Recipe tab will show the recipes test blocks and other components as shown below.

Illustration showing an open recipe

2.3.4

Run the desired Recipe

Running a recipe is as easy as: Pressing F5 on the keyboard Alternatively you may click the green Play button shown below

Run button on H3 GUI

Chapter 2: Quick Start Guide

13

H3 GUI OPERATIONS MANUAL


Once the user starts running a recipe, most buttons will gray out and the Stop button will become available for use. The Stop button is used in cases, where the user wants to abort a test run. The Log View window, below, shows status of tests from the first Test Block to the last is executed. The user may chose to monitor it for immediate intermediary result checking as the recipe is running.

Illustration of recipe running

Chapter 2: Quick Start Guide

14

H3 GUI OPERATIONS MANUAL


Once the recipe has completed its run or has been stopped manually by the user via the Stop button, then the Play button will become available again for the following run. At the same time, the results for the last run will be available on the DUT Display tab. The numbers shown in the grid represent a Bin Code for each individual DUT.

Illustration of DUT Display tab and individual DUT results

Chapter 2: Quick Start Guide

15

H3 GUI OPERATIONS MANUAL

Chapter 3: H3 GUI Comprehensive Usage


The H3 GUI has an extended set of menus, views and displays. In this chapter, the user will be able to understand the value and usage of such.

3.1 File Menu


The File Menu is composed of several options. All of which, are designed to give the user the ability to manipulate Recipes. Please see the illustration below showing all available options under the File Menu.

File Menu

3.1.1

Load Recipe

The Load Recipe menu option under the File menu allows the user to open an existing recipe. Some details of this option have been previously covered in Section 2.3.3 of this Manual.

Chapter 3: H3 GUI Comprehensive Usage

16

H3 GUI OPERATIONS MANUAL


3.1.2 New Recipe

The New Recipe menu option under the File menu allows the user to create a NEW recipe from scratch. In this sub-Section of the manual, we will go over an example of how to create a very simple recipe, to illustrate general usage.

3.1.2.1 Create and Save a NEW xml file


To create and save a NEW xml file, the user has to click on the New Recipe menu option under the File menu. That will open the following window. In the case below, the user has entered the name NewRecipe as a file name for the NEW xml file to be created. Upon clicking the Save button, the resulting NEW xml recipe will be NewRecipe.xml. One thing to note, a recipe can reside anywhere on the Desktop PC Controller, so the user may have also decided to change the Save in location of the resulting xml file.

Illustration of NEW xml creation and save

Chapter 3: H3 GUI Comprehensive Usage

17

H3 GUI OPERATIONS MANUAL


Once the NEW recipe has been created and saved, the XML Recipe tab will display the recipe.

Illustration of a NEW recipe upon creation The NEW recipe will have Global_User and Global_System input parameters. The user does generally not use these. It is highly recommended for a user not to alter these, unless advised by Tanisys. The right side of the illustration shows the details of whats available for viewing or change for the item highlighted on the left side. The example above shows Global_User highlighted (left side) and the properties of it (right side). If the user clicks on the NewRecipe.xml name in the tree view of the recipe (left side of the above illustration), the user can see and alter the path and filename of the associated Executable file for the recipe. The Download Files tab on the right hand side of the above illustration is now obsolete and should not be used by the user.

Chapter 3: H3 GUI Comprehensive Usage

18

H3 GUI OPERATIONS MANUAL


If the user clicks on Types, the H3 GUI will display all available types of variables.

Illustration of Types in a recipe

3.1.2.2 Manipulating Test Blocks and Input Parameters


On all types of recipes, whether new or existing, the user will, more than likely, need to add/alter Test Blocks and Input Parameters.

Chapter 3: H3 GUI Comprehensive Usage

19

H3 GUI OPERATIONS MANUAL


To add a Test Block, the user must right click on the recipe name. In the case below, the user has right clicked on the NewRecipe.xml label to bring up the menu. Once the menu is up, the user can click on Add Testblock.

Illustration of Add Testblock Once the Add Testblock has been clicked, the Test Block Editor window will pop up. The user must then input a Test Block Name and a Test Block Type. The example below shows the user has typed NewTestBlockName and NewTestBlockType in the respective fields. Take note, the Test Block Type must match the name in the application. (please see Programming Manual for details)

Test Block Editor Chapter 3: H3 GUI Comprehensive Usage 20

H3 GUI OPERATIONS MANUAL


Once the above input has been entered and the user has clicked Save, the resulting NEW Test Block will appear in the tree view of the recipe as shown below.

New Test Block To add an Input Parameter to a Test Block, the user must click on the Types tab and drag and drop the desired variable type from Types (see left on illustration below) to the Test Block (see right on the illustration below). In the following case, the user has dragged and dropped a bool type into the NewTestBlockName test block.

Drag and Drop of bool type into a Test Block

Chapter 3: H3 GUI Comprehensive Usage

21

H3 GUI OPERATIONS MANUAL


The user can drag and drop as many Input Parameters into a Test Block. In the case below, several steps were taken. The user changed the name of the bool variable to bBoolVariable. The user also dragged and dropped a char variable, which the user later changed its name to sString. The user also changed the Cnt, which is the count of characters from the default of 1 to 5. The user changed the Value of sString from a default of 0 to Hello.

Input Parameter manipulation

Chapter 3: H3 GUI Comprehensive Usage

22

H3 GUI OPERATIONS MANUAL


Clicking back to the Recipe tab from Types, the user can then follow up with several other action with a Test Block. To do so, the user must right click on the Test Block label, to bring up the menu. Please see below illustration. The user can choose several actions including: Adding another Test Block Deleting the highlighted Test Block Copying and Pasting the Test Block (once a Copy followed by a Paste occurs, H3 will automatically set a different Test Block Name to the New Test Block, but will keep the Test Block Type and all properties and Input Parameters) Moving up or down the Test Block in the list (if you have more than 1 Test Block) Enabling and Disabling one or more Test Blocks will change the execution of recipe. (a check mark on the left side of the Test Block indicates whether a certain Test Block is enabled or disabled. Importing and Exporting isnt supported any longer. Closing a recipe is also an option.

Available Menu for Test Blocks

Chapter 3: H3 GUI Comprehensive Usage

23

H3 GUI OPERATIONS MANUAL


There are also a number of available actions for an Input Parameter. Right clicking on any Input Parameter will give the user access to the options available (right hand side of illustration below). The main ones are copying and pasting.

Available Menu for Input Parameters

3.1.3

Save Recipe

The user may save the recipe file under a previously selected recipe name (in the previously selected file path) by clicking Save Recipe under the File menu. Alternatively, the user may click on the Save button shown in the below illustration.

Save button

Chapter 3: H3 GUI Comprehensive Usage

24

H3 GUI OPERATIONS MANUAL


3.1.4 Save Recipe As

The user may save the recipe file under a different name and path by clicking on Save Recipe As under the File menu. A window will pop up to select the new name and desired location on the Desktop PC Controller. Please see illustration below.

Save Recipe As window pop up

3.1.5

Close Recipe

The user may close a recipe by clicking Close Recipe under the File menu or by pressing the x button at the top right hand corner of the inner window.

3.1.6

Exit

The user may close the H3 GUI by clicking Exit under the File menu or by pressing the x button at the top right hand corner of the top window.

Chapter 3: H3 GUI Comprehensive Usage

25

H3 GUI OPERATIONS MANUAL

3.2 View Menu


The View Menu is composed of several options. All of which, are designed to give the user the ability to switch view of different parts of the H3 GUI. Please see the illustration below showing all available options under the View Menu.

View Menu

3.2.1

Refresh Blades

The Refresh Blades label under the View menu allows the user to ping or re-initiate connection to the HW Core board of the system. In many cases, this type of board is referred to as a Blade. Upon clicking on the Refresh Blades label, the Tanisys Test system will update the Log View window with all HW Core boards that have communicated back to the H3 GUI. Please see example of such below.

Log View after a Refresh Blade click

Chapter 3: H3 GUI Comprehensive Usage

26

H3 GUI OPERATIONS MANUAL


3.2.2 DUT Display

The DUT Display label under the View menu allows the user to bring up the graphical representation of the DUTs. This is a grid showing a partition of DUTs, with several features. The equivalent can be achieved by either pressing F7 or pressing the DUT Display tab. Please see illustration below for details.

DUT Display There are several viewing features on the DUT Display window: In general, test sites, that are available on all HW Core boards within a Chassis, are either represented with a white, green, gray or black rectangle. (i.e. white if HW Core board is Locked; green if HW Core board is Unlocked; gray if HW Core board is Locked, but specific DUT is disabled; black if HW Core board is not physically present within a Chassis). The DUT Display window also features a Blade Info box, in which the Chassis Serial Number, the Bay Number within a Chassis, the Slot Number of the Blade within a Bay, the Blade Serial Number, the IP address of the Blade, the Port to which the Blade is attached as well as the Lock/Unlock status.

Chapter 3: H3 GUI Comprehensive Usage

27

H3 GUI OPERATIONS MANUAL


There is also a Legend box that provides a quick reference to all permutations for status of any particular DUT, including the Bin Code coloring scheme for specific DUTs. In general, the previous test run result is represented within the rectangle containing the specific DUT, in which a Bin Code in green font represents a passing condition and a Bin Code in red font represents a failing condition. The user that developed the application determines the Bin Code number. In general, HW Bin Codes are used for binning compartments of Handlers or other equipment attached to a Tanisys Test System. The number of such HW Bin Codes is usually small (i.e. usually under 10 HW Bin Codes). On the other hand, SW Bin Codes give the freedom to the application developer the opportunity to use a large number of SW Bin Codes to distinguish between a variety of failure signatures of a failing DUT. The application developer can then associate a number of SW Bin Codes to a specific HW Bin Code. Please review the Programming Manual for more details on Bin Codes. There are a few action features on the DUT Display window: The user may Enable or Disable a particular DUT by either, right clicking on a particular DUT and selecting the opposite state from the current state of a DUT. (i.e. user can enable a previously disabled DUT or disable a previously enabled DUT). The same action can be achieved by selecting a particular DUT and pressing either the Disable DUT or Enable DUT on the right hand side of the grid. The Import and Export buttons should NOT be used, unless previously instructed by Tanisys. The user may also change the view of the DUT Display grid by selecting from a pull down between Show Bin Codes and Show Hifix Index. The first shows the DUT results from the previous test run. The latter shows the configuration of DUTs of a system thats connected to a Hifix and Handler. The user is also given the ability to view the Bin Codes in, either, Hex or Decimal as well as the ability for the H3 GUI to do the translation of Soft to Hard Bin Codes. These can be achieved by a click or unclick of the check boxes named Hex and H/W respectively.

3.2.3

Recipe

The Recipe label under the View menu allows the user to bring up the XML Recipe tab. Either pressing F8 or pressing the XML Recipe tab itself can achieve the equivalent.

Chapter 3: H3 GUI Comprehensive Usage

28

H3 GUI OPERATIONS MANUAL


3.2.4 Log

The Log label under the View menu allows the user to bring up the Log View tab. Either pressing F9 or pressing the Log View tab itself can achieve the equivalent. Please see the Log View tab shown below. The Log View displays the test results and print output from the user developed application.

Log View

3.2.4.1 Clear All


The Clear All button under Log View allows the user to clear the displayed text previously on the Log View window.

3.2.4.2 Log View Pull Down


The Log View pull-down defaulted with the name All allows the user to filter the displayed application output by HW Core board or Blade. The illustration below shows an example of this.

Pull down on Log View to filter by Blade

Chapter 3: H3 GUI Comprehensive Usage

29

H3 GUI OPERATIONS MANUAL


3.2.4.3 Log File Change
The H3 GUI allows for logging to not only be displayed in Log View, but to automatically save a text file in any user specified location, containing all the same data. Under the Log View tab, the user can select a new filename and location by clicking the button next to the current file display.

Current log file and location If the user clicks the above button, then the following window will pop up. The user may then select a filename and file path for the application output log. The log file name selected by the user is used to create the first log file. Subsequent log file names after the first has reached its predetermined size, will be a combination of the selected log file name and a number to indicate which one it is. The size and number of log files kept in the system is determined by the selections of the user in the Options Menu.

Selecting a new log file named NewLogFile

Chapter 3: H3 GUI Comprehensive Usage

30

H3 GUI OPERATIONS MANUAL


3.2.5 Real Time Statistics

The Real Time Statistics label under the View menu allows the user to view real time statistics of test results with various filters to obtain the desired data. When the user clicks on that label the tab below comes to the forefront. The equivalent would happen if the user just clicked on the Real Time Statistics tab adjacent to the Log View tab at the bottom of the H3 GUI. Please see the illustration below for details.

3.2.5.1 Results by Chassis


The Real Time Statistics tab has results by Chassis (see top of previous illustration or details below). The amount on the bar thats filled indicates the passing rate on each individual Blade (i.e. HW Core board).

Results by Chassis with no filtering

Chapter 3: H3 GUI Comprehensive Usage

31

H3 GUI OPERATIONS MANUAL


3.2.5.2 Results by Blade
The Real Time Statistics tab has results by Blade (see top of previous illustration or details below). The amount on the bar thats filled indicates the passing rate on each individual DUT slot.

Results by Blade with no filtering

3.2.5.3 Filtering
The Real Time Statistics tab allows the user to filter the data and narrow down to only display results of interest. The Select Blade box allows the user to pick any one Blade or All. The Select DUT box allows the user to pick any one DUT on each selected Blade.

Filtering data to display

3.2.6

Blades

The Blades button under View menu allows the user to bring the Blades tab to the forefront. The equivalent action would be to click on the Blades tab directly.

Chapter 3: H3 GUI Comprehensive Usage

32

H3 GUI OPERATIONS MANUAL

3.3 Lot Management Menu


The Lot Management Menu and all sub-component options are now obsolete and will be removed completely in a future release. Please refer below illustration for details.

Lot Management menu

3.4 Tools Menu


The Tools Menu is composed of several options. This section of the H3 GUI Operations manual will go over the details of the Tools Menu. Please see the illustration below showing all available options.

Tools Menu

Chapter 3: H3 GUI Comprehensive Usage

33

H3 GUI OPERATIONS MANUAL


3.4.1 Change Privilege

Under the Tools menu option, one can find an option called Change Privilege, under which all Privilege levels reside. The user must click on Change Privilege to bring up the options available and they are: Basic, Tech and Expert.

Illustration of how to change the privilege level The Basic option does not require any further input. However, once the user clicks on either Tech or Expert, then the user must know and input the required password for this access level. Tanisys Technology Inc provides these separately to the appropriate level staff.

Change Privilege Screen

Chapter 3: H3 GUI Comprehensive Usage

34

H3 GUI OPERATIONS MANUAL


3.4.2 Start Custom Front End

The Start Custom Front End option under the Tools menu is designed to launch any third party GUI control application designed by the customer. This button is basically used to launch all third party custom front end GUI/programs. If none, is available the error window below will appear.

H3 GUI Error if no third party custom front end is found

3.4.3

Reset Real Time Monitor

The Reset Real Time Monitor option under the Tools menu can be used by the user to reset all real time statistics to zero. Once the user has clicked on Reset Real Time Monitor, a warning window will pop up to ensure the user is given the opportunity to make a decision on the erasing of real time statistics data. The details, of the data being erased, have been previously covered in Section 3.2.5. Please refer to the illustration below for details.

Warning window to ensure user is sure prior to erase of real time statistics data

Chapter 3: H3 GUI Comprehensive Usage

35

H3 GUI OPERATIONS MANUAL


3.4.4 Run Tests

The Run Tests option under the Tools menu can be used by the user to run two Tanisys provided applications. These are Calibration and Diagnostics. Clicking on the Run Tests, then clicking on either Run Calibration or Run Diagnostics can do this Please refer to the illustration below to see the details.

Run Tests options to run Calibration and Diagnostics applications

3.4.5

GPIB Settings

The GPIB Settings option under the Tools menu can be used by the user to change GPIB settings to other equipment attached to the Tanisys Test System. In most cases, this equipment is a Handler. Once the user clicks on GPIB Settings, the window shown below will appear. The options selected must match the settings set on the Handler.

GPIB Settings window and options

Chapter 3: H3 GUI Comprehensive Usage

36

H3 GUI OPERATIONS MANUAL


3.4.6 Options

The Options label under the Tools menu can be utilized by the user to alter settings, including Error Bin Codes, Timeouts and Logging options. Once the user clicks on Options, window shown below will appear. The Errors field lets the user update the specific Hardware Bin Code to be used for System Failures. The Timeouts fields allow the user to update: a) the timeout to be used to locate a Blade in milliseconds; b) the timeout to be used to ensure a recipe does not run indefinitely (note: a timeout of 0 in this field does allow an infinite timeout); c) the timeout to be used to check connectivity with an attached Handler. The Log View field allows the user to set the maximum number of lines made available in the Log View tab at the bottom of the H3 GUI. The Log File fields allow the user to select: a) the maximum size of any saved log file; and b) the maximum number of log files present on the Desktop PC Controller at any time. The Yield Colors fields allow the user to change the coloring scheme of the passing yield bars in the Real Time Statistics tab.

Options window

Chapter 3: H3 GUI Comprehensive Usage

37

H3 GUI OPERATIONS MANUAL


3.4.7 Load Hifix Configuration

The Load Hifix Configuration option under the Tools menu allow the user to select a Hifix or DUT configuration file to match the corresponding Tanisys Test System configuration attached to the Desktop PC Controller. Once the user clicks on the Load Hifix Configuration label, the window shown below appears, from which the user may select a previously saved Hifix Config File already on the system.

Selecting a Hifix Configuration file to match the Hardware

Chapter 3: H3 GUI Comprehensive Usage

38

H3 GUI OPERATIONS MANUAL

3.5 Help
The Help menu option can be utilized by the user to identify important information regarding the installed version of the H3 GUI. Once the user clicks on the Help label, the window shown below appears. The details included are: a) Title of GUI; b) Product Version; c) File Version; d) User Level and e) Copyright Information.

Help menu

Chapter 3: H3 GUI Comprehensive Usage

39

H3 GUI OPERATIONS MANUAL

Chapter 4: Contact Information


4.1 Technical Support
Email is the best mode of contact for technical support. Click the link below:

[email protected]
Customer Service (toll free): 1-888-255-2210

4.2 Corporate Offices:


TANISYS Technology 11001 Lakeline Blvd. Building 1, Suite 150 Austin, TX 78717
512-335-4440 800-533-1744 http://www.tanisys.com/

4.3 Global Field Sales / Support Offices:


Europe - High Tech Trade gmbh Mario Will 49 (089) 54 67 8542 [email protected] Korea - NeoSem DH Yeom 82 31 213 6338 [email protected]

Chapter 4: Contact Information

40

H3 GUI OPERATIONS MANUAL

Appendix A: Glossary
The following table contains a brief description of frequently used terms and acronyms discussed in various Tanisys test system manuals.

TERM / ACRONYM
ADC Bin View CDROM Clock Controlled Impedance DAC DUT Adapter DPS DUT DVD DVM EEPROM

DEFINITION
Analog to Digital Converter Represents either or both software and hardware data collection counter bins Compact Disk Read Only Memory A continuously running signal that provides the timing reference for all DUT operations. A means of routing signals while maintaining a constant wiring impedance from source to termination. Digital to Analog Converter A plug-in interface board that has test sockets specific to a particular physical size and class of memory module. Digital Power Supply Device under test Digital Versatile Disk Digital Voltmeter Electrically Erasable Programmable Read-Only Memory. A nonvolatile memory device that can retain information when power is removed Electrostatic Discharge. Static electricity charges that can accumulate to thousands of volts (when a person moves across a floor, for example) which can discharge to and damage electronic devices. A grounded wrist strap can provide protection at the workstation against ESD.

ESD

Appendix A: Glossary

41

H3 GUI OPERATIONS MANUAL


ETC (Embedded Tester Control) A device independent DNA2 module, which operates on the embedded processor as a intermediary between the Tester Control on the PC and the Testers hardware. Its primary job is to launch test applications, communicate testing progress and results and manage the testing process to maximize testing. First In, First Out Field Replaceable Unit Graphic User Interface Automated equipment attached to a memory tester; used for bulk testing and sorting of memory modules or chips into Passed and Failed bins. As used here, an individual memory chip mounted on a module or card. Joint Electron Device Engineering Council. An industry group established to agree upon standards for electronic components such as memory devices. Light-Emitting Diode. A rugged solid-state indicator that emits light at a specific color. Visual representation of active, inactive, or disabled test sites The NFS Server allows the embedded Linux system access to the Windows file system. Security can be individually configured for each shared directory. One billionth of a second. Mathematically: 10 9 seconds. 1ns = 1E-09 sec Part Number A system of storing one additional bit per byte, allowing detection of single-bit errors. Personal Computer Printed Circuit Board Parametric Measurement Unit. A precision device to measure DC voltage and current. Read/Write Test File (.tts) site configuration board A device independent DNA2 module, which operates on the PC as a intermediary between the GUI on the PC and the ETC module executing on the tester hardware. Its primary job is to maintain the operational status of the tester hardware and route the messages between the PC and embedded tester processors. One or more test blocks are contained in a test flow. User Datagram Protocol One millionth of a second. Mathematically: 10 6 seconds. 1s = 1E-06 sec The number of bits that can be read or written in a single memory 42

FIFO FRU GUI Handler

IC (Integrated Circuit) JEDEC

LED Map View NFS

ns (nanosecond) P/N Parity PC PCB PMU R/W Recipe SCB TCM

Test Block UDP s (microsecond) Width Appendix A: Glossary

H3 GUI OPERATIONS MANUAL


Windows Work Flow Workspace XML cycle. Microsoft Windows XP Professional Flowchart of test blocks contained in the test file. Establishes the software configuration, (i.e. software view, software behavior, visible windows, map view, bin view, etc.) Extensible Markup Language

Appendix A: Glossary

43