0% found this document useful (0 votes)
29 views2 pages

WP Contentuploads2020010518E1W IN010424E PDF

The document details the E1W Captive Component Gland designed for steel and aluminum armored cables, highlighting its features such as indoor/outdoor use, a patented disconnect system, and IP65/66/68 sealing capabilities. It provides technical specifications, including materials, standards, and installation instructions. Additionally, it lists various product codes and dimensions for different gland sizes.

Uploaded by

Tim Wong
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
29 views2 pages

WP Contentuploads2020010518E1W IN010424E PDF

The document details the E1W Captive Component Gland designed for steel and aluminum armored cables, highlighting its features such as indoor/outdoor use, a patented disconnect system, and IP65/66/68 sealing capabilities. It provides technical specifications, including materials, standards, and installation instructions. Additionally, it lists various product codes and dimensions for different gland sizes.

Uploaded by

Tim Wong
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

C A B L E T E R M I N AT I O N S

E1W
CAPTIVE COMPONENT GLAND ®

for Steel and Aluminium Armoured Cable


Features and Benefits
• For indoor and outdoor use.
• Two-piece handling, no loose parts.
• Freely rotating captive cone and inspectible cone ring, providing an armour clamp and earth bond without twisting
the armour wire.
• Patented disconnect system for armour clamp inspection. Factory fitted captive elastomeric inner seal for Built-in
Safety™. Seals on both the inner and outer sheath of the cable to IP65/66/68.
• Precision manufactured from high-quality brass (Nickel Plated) available in aluminium or stainless steel
316/316L on request.
• Complete with thread sealing gasket and with a heavy-duty locknut.
Technical Data
Type: E1W
Gland Material: Brass (Nickel Plated), BS 2874, EN 12164, Aluminium ASTM BS221,
Stainless Steel 316/316L
C
Seal Material: Thermoset Elastomer or Silicone on request
Cable Type: Steel Wire Armour and Aluminium Armour Wire A
Armour Clamping: Rotating Captive Cone and Inspectible Cone Ring
Sealing Area: Inner Sheath and Outer Sheath
Optional Accessories: Adaptor, Reducer, Earth Tag, Locknut, Serrated Washer and Shroud
Standards and Certifications
Mechanical Properties: Impact Category 8 D
Anchorage Type D
Electrical Properties: Category A (no earth tag)
Category B (with earth tag)
Continuous Operating Temp: -65°C to +120°C
Conformance: Standard: Certification:
Design Standards BS 6121:Part 1 CML 14CA364
EN 50262 CML 14CA364 E
IEC/BS EN 62444 CML 14CA364 F
SANS 62444 MASC 22-9012
SANS 1213 MASC 18-2047, SANS 2109/4596
IP66/68 100m - Parallel IEC 60529 CML 15Y728, MASC 22-9015
IP65 - Tapered IEC 60529
Marine ABS IEC 60529, IEC 62444 ABS 20-SG1952694-PDA
DNV IEC 60529, BS 6121, IEC 62444 TAE000000Z
EMC Compatible EN 55011, A1, EN 55022 SGS EMC305079/1
London Underground Approval BS EN 62444 LU 3043

®
®

Installation Standards
• AS/NZS 3000 • BS 7671 • IEC 60364-5-54 PATENTED
• BS 6121-5 • BS 7430 • SANS 0142
Gland Metric Entry Thread NPT Entry Thread Cable Detail Max Armour Dia Hexagonal Detail Install
Product
Size Min Min Min Max Min Max Length Min Max Max Max Torque
Code ‘C’ ‘C’
Reference ‘D’ ‘D’ ‘A’ ‘A’ ‘B’ ‘B’ ‘E’ ‘F’ ‘F’ ‘Flats’ ‘Crns’ Value Nm
051800-16 00-16ss M16x1.5 10 - - 3.0 8.5 8.0 13.5 52.0 0.90 
0.90 
24.0 27.0 35.0
051800 00-20ss M20x1.5 10 ½ 15 3.0 8.5 8.0 13.5 52.0 0.90 
0.90 
24.0 27.0 35.0
0518-0 0-20s M20x1.5 10 ½ 15 7.0 12.0 11.5 16.0 52.0 0.90 
1.25 
24.0 27.0 35.0
051801 1-20 M20x1.5 10 ½/¾ 15 11.0 15.0 14.5 20.5 56.0 0.90 1.25 27.0 30.0 35.0
051822 2s-25s M25x1.5 10 ¾/1 15/19 11.0 17.5 16.0 24.5 65.0 1.25 1.60 35.0 39.0 50.0
051802 2-25 M25x1.5 10 ¾/1 15/19 14.0 20.0 20.5 26.5 65.0 1.25 1.60 35.0 39.0 50.0
051833 3s-32s M32x1.5 10 1/1¼ 19 15.0 22.0 23.0 30.5 65.0 1.60 2.00 42.0 47.0 70.0
051803 3-32 M32x1.5 10 1/1¼ 19 19.0 26.5 26.5 33.5 65.0 1.60 2.00 42.0 47.0 70.0
051844 4s-40s M40x1.5 15 1¼/1½ 19/21 22.0 31.5 30.0 39.5 80.0 1.60 2.00 52.0 59.0 90.0
051804 4-40 M40x1.5 15 1¼/1½ 19/21 26.0 34.0 33.0 42.5 80.0 1.60 2.00 52.0 59.0 90.0
051855 5s-50s M50x1.5 15 1½/2 21 29.0 38.0 34.0 47.5 95.0 2.00 2.50 65.0 73.0 100.0
051805 5-50 M50x1.5 15 1½/2 21 34.0 44.5 42.5 52.5 95.0 2.00 2.50 65.0 73.0 100.0
051866 6s-63s M63x1.5 15 2/2½ 30 38.0 50.0 45.5 60.5 116.0 2.00 2.50 80.0 90.0 120.0
051806 6-63 M63x1.5 15 2/2½ 30 44.0 56.5 52.5 65.5 116.0 2.00 2.50 80.0 90.0 120.0
2024 © CCG CABLE TERMINATIONS (PTY) LTD

051877 7s-75s M75x1.5 15 2½/3 32 50.0 62.0 57.0 72.5 127.0 2.50 3.15 96.0 108.0 120.0
051807 7-75 M75x1.5 15 2½/3 32 56.0 67.5 65.5 78.0 127.0 2.50 3.15 96.0 108.0 120.0
051808 8-80 M80x2.0 20 3 32 68.0 74.0 78.0 82.0 120.0 2.50 3.15 96.0 108.0 120.0
051899 9s-90s M90x2.0 20 3/3½ 32/33 66.0 75.0 73.0 86.5 142.0 3.00 3.50 111.0 125.0 120.0
051809 9-90 M90x2.0 20 3/3½ 32/33 74.0 81.5 82.0 91.0 142.0 3.00 3.50 111.0 125.0 120.0
051810 10-100 M100x2.0 20 3½/4 33/34 81.0 91.0 90.0 100.0 142.0 3.00 3.50 125.0 141.0 120.0
051811 11-110 M110x2.0 20 4 34 86.0 98.0 100.0 114.0 142.0 3.00 4.00 135.0 152.0 120.0
051812 12-120 M120x2.0 20 - - 96.0 103.0 103.0 118.0 142.0 3.00 4.00 140.0 158.0 120.0
051813 13-130 M130x2.0 20 - - 100.0 115.0 113.0 124.0 165.0 3.00 4.00 146.0 164.0 120.0
All dimensions except NPT are in mm.

When manufactured in Aluminium, Hex will be 27 Across Flats and 30 Across Corners.
CCG reserves the right to make alterations to the technical data, dimensions, designs and products available without notice. The illustrations cannot be considered binding. Please contact CCG for assistance. E1W-IN010424E
FITTING INSTRUCTIONS
C A B L E T E R M I N AT I O N S
Metric Illustration
E1W CAPTIVE COMPONENT GLAND ®

1. For accurate sizing, use a CCG Dimension Tape  on the inner and outer cable sheath.

2. Cut back the cable outer sheath to expose the armour to a length not more than the outer nut .

  Locknut
 Alternative installation Serrated Washer

through an unthreaded entry.

If the apparatus is untapped


use a locknut.

3. To maintain IP66/68, ensure the gasket  is in place. Screw the inner  If the gland has NPT entry threads fitted to a threaded entry then IP68 (2m) can be
achieved by applying one of the following tested and approved grease types to the
into the apparatus. Tighten the inner ‚ to installation torque using a
thread:- Renolit Lubrene CA700 or LX220 EP2, Renolit LC-WP2 or Moly LX2, or Dow
CCG Spanner . Corning 4 Electrical Compound.

 

4. Pass the outer nut  and the body  over the cable.

 

5. Pass cable end through the inner  and splay the armour wires over the cone .

 

6. Tighten the body  onto the inner  until hand tight, then tighten with a CCG Spanner  with ¾ turn to lock the armour between the cone  and the
cone ring .
 

7. Unscrew the body . Check that the armour has locked between the cone  and the cone ring . (O-Ring on the cone ring  is sacrificial)

  

8. Tighten the body  onto the inner  to the installation torque using a CCG Spanner . Tighten the outer nut  to produce a moisture proof seal by
turning until the seal makes contact with the outer sheath of cable and then turn one full turn.