WP Contentuploads2020010518E1W IN010424E PDF
WP Contentuploads2020010518E1W IN010424E PDF
E1W
CAPTIVE COMPONENT GLAND ®
®
®
Installation Standards
• AS/NZS 3000 • BS 7671 • IEC 60364-5-54 PATENTED
• BS 6121-5 • BS 7430 • SANS 0142
Gland Metric Entry Thread NPT Entry Thread Cable Detail Max Armour Dia Hexagonal Detail Install
Product
Size Min Min Min Max Min Max Length Min Max Max Max Torque
Code ‘C’ ‘C’
Reference ‘D’ ‘D’ ‘A’ ‘A’ ‘B’ ‘B’ ‘E’ ‘F’ ‘F’ ‘Flats’ ‘Crns’ Value Nm
051800-16 00-16ss M16x1.5 10 - - 3.0 8.5 8.0 13.5 52.0 0.90
0.90
24.0 27.0 35.0
051800 00-20ss M20x1.5 10 ½ 15 3.0 8.5 8.0 13.5 52.0 0.90
0.90
24.0 27.0 35.0
0518-0 0-20s M20x1.5 10 ½ 15 7.0 12.0 11.5 16.0 52.0 0.90
1.25
24.0 27.0 35.0
051801 1-20 M20x1.5 10 ½/¾ 15 11.0 15.0 14.5 20.5 56.0 0.90 1.25 27.0 30.0 35.0
051822 2s-25s M25x1.5 10 ¾/1 15/19 11.0 17.5 16.0 24.5 65.0 1.25 1.60 35.0 39.0 50.0
051802 2-25 M25x1.5 10 ¾/1 15/19 14.0 20.0 20.5 26.5 65.0 1.25 1.60 35.0 39.0 50.0
051833 3s-32s M32x1.5 10 1/1¼ 19 15.0 22.0 23.0 30.5 65.0 1.60 2.00 42.0 47.0 70.0
051803 3-32 M32x1.5 10 1/1¼ 19 19.0 26.5 26.5 33.5 65.0 1.60 2.00 42.0 47.0 70.0
051844 4s-40s M40x1.5 15 1¼/1½ 19/21 22.0 31.5 30.0 39.5 80.0 1.60 2.00 52.0 59.0 90.0
051804 4-40 M40x1.5 15 1¼/1½ 19/21 26.0 34.0 33.0 42.5 80.0 1.60 2.00 52.0 59.0 90.0
051855 5s-50s M50x1.5 15 1½/2 21 29.0 38.0 34.0 47.5 95.0 2.00 2.50 65.0 73.0 100.0
051805 5-50 M50x1.5 15 1½/2 21 34.0 44.5 42.5 52.5 95.0 2.00 2.50 65.0 73.0 100.0
051866 6s-63s M63x1.5 15 2/2½ 30 38.0 50.0 45.5 60.5 116.0 2.00 2.50 80.0 90.0 120.0
051806 6-63 M63x1.5 15 2/2½ 30 44.0 56.5 52.5 65.5 116.0 2.00 2.50 80.0 90.0 120.0
2024 © CCG CABLE TERMINATIONS (PTY) LTD
051877 7s-75s M75x1.5 15 2½/3 32 50.0 62.0 57.0 72.5 127.0 2.50 3.15 96.0 108.0 120.0
051807 7-75 M75x1.5 15 2½/3 32 56.0 67.5 65.5 78.0 127.0 2.50 3.15 96.0 108.0 120.0
051808 8-80 M80x2.0 20 3 32 68.0 74.0 78.0 82.0 120.0 2.50 3.15 96.0 108.0 120.0
051899 9s-90s M90x2.0 20 3/3½ 32/33 66.0 75.0 73.0 86.5 142.0 3.00 3.50 111.0 125.0 120.0
051809 9-90 M90x2.0 20 3/3½ 32/33 74.0 81.5 82.0 91.0 142.0 3.00 3.50 111.0 125.0 120.0
051810 10-100 M100x2.0 20 3½/4 33/34 81.0 91.0 90.0 100.0 142.0 3.00 3.50 125.0 141.0 120.0
051811 11-110 M110x2.0 20 4 34 86.0 98.0 100.0 114.0 142.0 3.00 4.00 135.0 152.0 120.0
051812 12-120 M120x2.0 20 - - 96.0 103.0 103.0 118.0 142.0 3.00 4.00 140.0 158.0 120.0
051813 13-130 M130x2.0 20 - - 100.0 115.0 113.0 124.0 165.0 3.00 4.00 146.0 164.0 120.0
All dimensions except NPT are in mm.
When manufactured in Aluminium, Hex will be 27 Across Flats and 30 Across Corners.
CCG reserves the right to make alterations to the technical data, dimensions, designs and products available without notice. The illustrations cannot be considered binding. Please contact CCG for assistance. E1W-IN010424E
FITTING INSTRUCTIONS
C A B L E T E R M I N AT I O N S
Metric Illustration
E1W CAPTIVE COMPONENT GLAND ®
1. For accurate sizing, use a CCG Dimension Tape on the inner and outer cable sheath.
2. Cut back the cable outer sheath to expose the armour to a length not more than the outer nut .
Locknut
Alternative installation Serrated Washer
3. To maintain IP66/68, ensure the gasket is in place. Screw the inner If the gland has NPT entry threads fitted to a threaded entry then IP68 (2m) can be
achieved by applying one of the following tested and approved grease types to the
into the apparatus. Tighten the inner ‚ to installation torque using a
thread:- Renolit Lubrene CA700 or LX220 EP2, Renolit LC-WP2 or Moly LX2, or Dow
CCG Spanner . Corning 4 Electrical Compound.
4. Pass the outer nut and the body over the cable.
5. Pass cable end through the inner and splay the armour wires over the cone .
6. Tighten the body onto the inner until hand tight, then tighten with a CCG Spanner with ¾ turn to lock the armour between the cone and the
cone ring .
7. Unscrew the body . Check that the armour has locked between the cone and the cone ring . (O-Ring on the cone ring is sacrificial)
8. Tighten the body onto the inner to the installation torque using a CCG Spanner . Tighten the outer nut to produce a moisture proof seal by
turning until the seal makes contact with the outer sheath of cable and then turn one full turn.
Tel: South Africa +27 11 3942020/1, Australia +1300 CABLE GLANDS (1300 222 534), Hong Kong +852 3427 2090,
Singapore +65 6 8421 002, South Korea +82 51 808 1161, United Kingdom +44 1 642 430346, United Arab Emirates +971 6 552 7781