GROUND WATER
SURFACE WATER
2.Q. THE LOCATION OF TRETMENT PLANT
One complete water treatment plant requires the following process starting from
the source of water upto the distribution zone in order of sequence.
Sl.No. Name of the unit Purpose
1. Intake work including pumping plant Raw water from the source for
treatment
2. Plain sedimentation To remove suspended impurities
such as silt, clay, sand etc.
3. Sedimentation with coagualtion To remove the suspended matter
9. Pumps for pumping the water in service If town or city is situated at higher
reservoirs elevation then pumping is required.
10. Elevated or underground service For distribution of treated water.
reservoir
1 www.Jntufastupdates.com
3.Q The following points should be kept in mind while giving layout of
any treatmentplant.
1. The W.T.P. should be located as near to the town so as to avoid the contamination.
2. All the units of plant should be located in order of sequence and flow from one unit to
other by gravity.
3. All the units are arranged in such a way that minimum area is required so as to reduce
the cost of construction.
4. Sufficient area should be reserved for the future expansion
5. Staff quarters and office should be provided near the treatment plants so that the
operators can watch the plants easily.
6. The site of treatment plant should be very neat and give very good asthetic
appearance.
SCREENING
Screens are fixed in the intake works or at the entrance of treatment plant so as to
remove the floating matters as leaves, dead animals etc.
PLAIN SEDIMENTATION :
The amount of matter removed by sedimentation tank depends upon the factors.
1. Velocity of flow
2. size and shape of particles
3. Viscosity of water
The particles which do not change in size, shape or mass during settling are known as the
discrete particles. The velocity of descrete particles with dia less than 0.1 mm is given by
2 www.Jntufastupdates.com
In practice settling of the particles governed by the resultant of horizontal velocity of
water and the verticle downward velocity of the particle. The path of the settling particle
is as shown in Fig 5.2.
SELLING ZONE
I O
N U
x L T
E L
T E
Z T
O Z
N S L U D G E Z O N EO
E
E
(1) Velocity of flow: The velocity of flow of water in sedimentation tanks should be
sufficient enough to cause the hydraulic subsidence of suspended impurities. It
should remain uniform throughout the tank and it is generally not allowed to exceed
150mm to 300mm per minute.
(2) Capacity of tank: capacity of tank is calculated by
i) detension period
ii) Overflow rate
(i) Detension period: The theoretical time taken by a particle of water to pass between
entry and exit of a settling tank is known as the known as the detention period. The
capacity of tank is calculated by
3 www.Jntufastupdates.com
(ii) Overflow Rate: in this method it is assumed that the settlement of a particle at
the bottom of the settlement of a particle at the bottom of the tank doesnot depend
on the depth of tank and depends upon the surface area of the tank.
D.Q D xQ Q
Surface overflow rate, V = ------ = ----------- = ---------
C LxBxD LxB
Where L → Length of tank
B → Breadth of tank
D → Depth of tank = Side water depth = S.W.D
C → Capacity of tank
T → Detention period
U → Discharge or rate of flow
V → Velocity of descend of a particle to the bottom of tank
= Surface overflow rate = S.O.R
The inlet is a device, which is provided to distribute the water inside a tank, and the
outlet is a device, which is meant to collect outgoing water. These arrangements
should be properly designed and located in a such a way that they do not form any
obstruction or cause any disturbance to the flowing water.
SHAPES OF TANKS
Following are the three shapes of settling tank.
(i) Rectangular tanks with horizontal flow
(ii) Circular tanks with radial or spiral flow
(iii) Hopper bottom tanks with vertical flow
The following are the parameters for satisfactory performance.
The following are the mostly used Coagulants with normal dose and PH values
required for best floc formation as shown in Table
Sl.No. Coagulant PH Range Dosage mg/l
1. Aluminium sulphate 5.5 – 8.0 5 – 85
Al2(SO4)3, 18 H2O
2. Sodium Aluminate, Na2Al2O4 5.5 – 8.0 3.4 – 34
3. Ferric Chloride (Fecl3) 5.5 – 11.0 8.5 – 51
4. Ferric Sulphate Fe 2 (SO )
4 3 5.5 – 11.0 8.5 – 51
5. Ferric Sulphate FeSO47H2O 5.5 – 11.0 8.5 - 51
Coagulants are chosen depending upon the PH of water. Alum or Aluminium
sulphate is normally used in all treatment plants because of the low cost and ease of
storage as solid crystals over long periods.
The dosage of coagulants, which should be added to the water, depends upon
kind of coagulant, turbidity of water, colour of water, PH of water, temperature of water
and temperature of water and mixing & flocculation time. The optimum dose of
coagulant required for a water treatment plant is determined by a Jar test as shown in
Fig
For starting the experiment first of all the sample of water is taken in every jar
and added the coagulant in a jar in varying amounts. The quantity of coagulant added in
each jar is noted. Then with the help of electric motar all the paddles are rotated at a
speed of 30-40 R.P.M. for about 10 minutes. After this the speed is reduced and paddles
are rotated for about 20-30 minutes. The rotation of paddles is stopped and the floc
formed in each Jar is noted and is allowed to settle. The dose of coagulant which gives
the best floc is the optimum dose of coagulants.
The coagulants may be fed or allowed to enter either in powder form called dry
feeding or in solution form called wet feeding. The mixing of coagulant with the water
to form the floc by the following methods.
1. Centrifugal pump
2. compressed air
3. hydraulic jump
4. mixing channel
5. mixing basins with buffle walls
6. Mixing basins with mechanical means
5 www.Jntufastupdates.com
Now a days some firms manufacture combined unit comprising of feeding,
mixing, flocculator and clarifier device. The Fig shows used for sedimentation with
coagulation.
Water enters in this tank through central inlet pipe placed inside the deflector box.
The deflector box deflects the water downwards and then it goes out through the holes
provided sides of the deflector box. The water flows radially from the deflector box
towards the circumference of the tank, where outlet is provided on the full periphery as
shown in the Fig. All the suspended particles along with floc settle down on the slopy
floor and clear water goes through outlet. The sludge is removed by scrapper which
continuously moves around the floor with very small velocity.
FILTRATION
The process of passing the water through beds of sand or other granular materials
is known as filtration. For removing bacteria, colour, taste, odours and producing clear
and sparkling water, filters are used by sand filtration 95 to 98% suspended impurities are
removed.
THEORY OF FILTRATION
The following are the mechanisms of filtration
1. Mechanical straining – Mechanical straining of suspended particles in the sand
pores.
2. Sedimentation – Absorption of colloidal and dissolved inorganic matter in the
surface of sand grains in a thin film
3. Electrolytic action – The electrolytic charges on the surface of the sand particles,
which opposite to that of charges of the impurities are responsible for binding
them to sand particles.
4. Biological Action – Biological action due to the development of a film of
microorganisms layer on the top of filter media, which absorb organic impurities.
Filtration is carries out in three types of filters
1. Slow sand filter
2. Rapid sand filter Gravity filters
3. Pressure filter
6 www.Jntufastupdates.com
6.Q. EXPALIN SLOW SAND FILTER WITH NET FIGURE
Slow sand filters are best suited for the filtration of water for small towns. The
sand used for the filtration is specified by the effective size and uniformity coefficient .
The effective size, D10, which is the sieve in millimeters that permits 10% sand by
weight to pass. The uniformity coefficient is calculated by the ratio of D 60 and D10.
CONSTRUCTION
Slow sand filter is made up of a top layer of fine sand of effective size 0.2. to
0.3mm and uniformity coefficient 2 to 3 . The thickness of the layer may be 75 to 90 cm.
Below the fine sand layer, a layer of coarse sand of such size whose voids do not permit
the fine sand to pass through it. The thickness of this layer may be 30cm. The lowermost
layer is a graded gravel of size 2 to 45mm and thickness is about 20 to 30cm. The gravel
is laid in layers such that the smallest sizes are at the top. The gravel layer is the retains
for the coarse sand layer and is laid over the network of open jointed clay pipe or
concrete pipes called under drainage. Water collected by the under drainage is passed into
the out chamber
During filtration as the filter media gets clogged due to the impurities, which stay
in the pores, the resistance to the passage of water and loss of head also increases. When
the loss of head reaches 60cm, filtration is stopped and about 2 to 3 cms from the top of
bed is scrapped and replaced with clean sand before putting back into service to the filter.
The scrapped sand is washed with the water, dried and stored for return to the filter at the
time of the next washing . The filter can run for 6 to 8 weeks before it becomes necessary
to replace the sand layer.
7 www.Jntufastupdates.com
USES
The slow sand filters are effective in removal of 98 to 99% of bacteria of raw
water and completely all suspended impurities and turbidity is reduced to 1 N.T.U. Slow
sand filters also removes odours, tastes and colours from the water but not pathogenic
bacteria which requires disinfection to safeguard against water-borne diseases. The slow
sand filters requires large area for their construction and high initial cost for
establishment. The rate of filtration is also very slow.
MAINTENANCE
The algae growth on the overflow weir should be stopped. Rate of filtration
should be maintained constant and free from fluctuation. Filter head indicator should be
in good working condition. Trees around the plant should be controlled to avoid bird
droppings on the filter bed, No coagulant should be used before slow sand filtration since
the floc will clog the bed quickly.
Rapid sand filter are replacing the slow sand filters because of high rate of
filtration ranging from 100 to 150m3/m2/day and small area of filter required. The main
features of rapid sand filter are as follows.
8 www.Jntufastupdates.com
OPERATION
The water from coagulation sedimentation tank enters the filter unit through inlet
pipe and uniformily distributed on the whole sand bed. Water after passing through the
sand bed is collected through the under drainage system in the filtered water well. The
outlet chamber in this filter is also equipped with filter rate controller. In the beginning
the loss of head is very small. But as the bed gets clogged, the loss of head increases and
the rate of filtration becomes very low. Therefore the filter bed requires its washing.
WASHING OF FILTER
Washing of filter done by the back flow of water through the sand bed as shown
in Fig
First the value „A‟ is closed and the water is drained out from the filter leaving a
few centimeter depth of water on the top of sand bed. Keeping all values closed the
compressed air is passed through the separate pipe system for 2-3 minutes, which agitates
the sand bed and stirrer it well causing the loosening of dirt, clay etc. inside the sand bed.
Now value „C‟ and „B‟ are opened gradually, the wash water tank, rises through the
laterals, the strainers gravel and sand bed. Due to back flow of water the sand expands
and all the impurities are carried away with the wash water to the drains through the
channels, which are kept for this purpose.
9 www.Jntufastupdates.com
7.Q. Comparision of slow sand filter and rapid sand filter
2. Raw Water Not more than 30 NTU Not more than 10NTU
Turbidity hence needs coagulation
3. Sand Media Effective size 0.2 to 0.3 Effective size 0.45 to 0.7
mm uniformity coefficient mm uniformity coefficient
2 to 3 single layer of 1.3 to 1.7 multiple graded
uniform size layers of sand.
4. Rate of 2.4 to 3.6m3/m2/day 100-150 m3/m2/day
Filtration
5. Loss of Head 0.6m to 0.7 m 1.8m to 2.0m
Pressure filter is type of rapid sand filter in a closed water tight cylinder through
which the water passes through the sand bed under pressure. All the operations of the
filter is similar to rapid gravity filter, expect that the coagulated water is directly applied
to the filter without mixing and flocculation. These filters are used for industrial plants
but these are not economical on large scale.
Pressure filters may be vertical pressure filter and horizontal pressure filter. The
Fig shows vertical pressure filter. Backwash is carried by reversing the flow with
values. The rate of flow is 120 to 300m3/m2/day.
10 www.Jntufastupdates.com
Figure Vertical Pressure Filter
ADVANTAGES
1. It is a compact and automatic operation
2. These are ideal for small estates and small water works
3. These filters requires small area for installation
4. Small number of fittings are required in these filters
5. Fitered water comes out under pressure no further pumping is required.
6. No sedimentation and coagulant tanks are required with these units.
DISADVATAGES
1. Due to heavy cost on treatment , they cannot be used for treatment large quantity of
water at water works
2. Proper quality control and inspection is not possible because of closed tank
3. The efficiency of removal of bacteria & turbidity is poor.
4. Change of filter media, gravel and repair of drainage system is difficult.