FD-G50 Modèle
FD-G50 Modèle
FD-G50
Clamp-On Gas Flow Meter DN 32A/40A/50A
*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.
Specifications
Model FD-G50
Pipe size DN (Diameter Nominal) 32 A, 40 A, 50 A
NPS (Nominal Pipe Size) 1 1/4", 1 1/2", 2"
Outer diameter of pipe ø41 to 45 mm 1.61" to 1.77", ø47 to 51 mm 1.85" to 2.01", ø58 to 62 mm 2.28" to
2.44"
Pipe thickness 2.4 to 5.7 mm 0.09" to 0.22"
Supported pipe materials Iron, steel, stainless steel
Supported fluids Air, Nitrogen, other gases*1
Fluid temperature 0 to 60ºC 32 to 140 °F
Recommended pressure 0.4 MPa or greater (58 PSI or greater)
Rated velocity of flow range Up to 15 m/s
Actual flow rate m3/h Pipe size 32 A: 54.00
range (typical) Pipe size 40 A: 72.00
Pipe size 50 A: 120.00
L/min Pipe size 32 A: 900.0
Pipe size 40 A: 1200.0
Pipe size 50 A: 2000.0
CFM Pipe size 32 A: 32.00
Pipe size 40 A: 42.00
Pipe size 50 A: 70.00
Standard flow rate 20°C 68°F 60 psi 0.41 MPa Pipe size 32 A: 151.58
range (typical) [CFM] Pipe size 40 A: 198.95
Pipe size 50 A: 331.58
20°C 68°F 80 psi 0.55 MPa Pipe size 32 A: 192.17
Pipe size 40 A: 252.22
Pipe size 50 A: 420.37
20°C 68°F 100 psi 0.69 MPa Pipe size 32 A: 232.76
Pipe size 40 A: 305.49
Pipe size 50 A: 509.16
20°C 68°F 120 psi 0.83 MPa Pipe size 32 A: 273.35
Pipe size 40 A: 358.77
Pipe size 50 A: 597.95
Display QVGA 2.2" LCD color monitor
Display update cycle Approx. 3 Hz
Display resolution Instantaneous flow rate 0.01 m3/h, 0.1 L/min, 0.01 CFM
Consumption/leakage amount 0.01 m3, 1 L, 0.1 CF
Response time 1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable)
Measurement Between 10 and 100% of F.S. ±2.0% of RD*2*3*4*5
accuracy
Between 1 and 10% of F.S. ±1.0% of F.S.*2*3*4*5
Zero point error ±0.15% of F.S.*2*6
*1 The gas must be uniform and capable of transmitting ultrasonic waves. Measurement may be unstable due to the pressure inside of the pipe and the
type of gas.
*2 This value is guaranteed by KEYENCE inspection facilities. Errors will be introduced by factors such as the type and status of the pipe and the type
and temperature of the gas.
*3 This is the value when considering linearity + span error in a stable environment with a temperature of 25°C 77°F.
*4 Defined with stable velocity of flow distribution. Does not include pulsations and fluctuations in the velocity of flow distribution primarily attributable to
the equipment.
*5 The linearity error characteristic due to the pipe is not included in this value.
*6 It is possible to reduce zero point errors by performing an origin adjustment.
*7 This is the value within the range where measurement accuracy is guaranteed.
*8 When Bi-directional is specified, the following functions cannot be used. The selection of the comparison view/leak ratio view/static leakage, the
measurement/display of the leakage amount/integrated flow, the setting of the target value/warning set value, and money conversions. Also, the I/O
settings are limited as shown below.
• ch.1: Pulse(+) mode
• ch.2: Pulse(-) mode, Error output mode, Integrated flow reset, Flow zero input, Origin adjustment input
*9 IO-Link: Compatible with specification v1.1/COM1 (4.8 kbps). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V.
(PNO).
*10 The IP65/67 enclosure rating is lost when a USB connection is established.
Dimensions
* Download CAD file or product manual for larger image/text and more detail.