Please use Secure Original Test Report pdf for
for Client Submission.
Analytical Chemistry Section
Chemical Analysis Report
DATE 30-OCT-2023 SAMPLE# 300 - 117586 REPORT# CR34946-EN-S1 REVISION# 0 JOB# 353997
ABRADANT INTERNATIONAL GENERAL ATTENTION Mr.Ajin Varghese
TRADING L.L.C TEST METHOD As Below
CLIENT PO BOX : 644763
Dubai ANALYSIS DATE 25-OCT-2023
As Below United Arab Emirates ANALYST BEK/BDZ/BCK
Garnet sample Garnet sample
Product Name: DECCANProduct
GARNET
Name: DECCAN GARNET
Sample
Grade: 30/60 Mesh Grade: 30/60 Mesh
Description
Batch No.: 3149/6499Batch No.: 3149/6499
Sample received date:
Sample
25-OCT-2023@12:00
received date: 25-OCT-2023@12:00
Hrs. Hrs.
Sampled by: Abu Dhabi
Sampled
Coating
by:Enterprises
Abu DhabiWLL
Coating
. Enterprises WLL .
TEST METHOD LIMITS AS PER RESULT
TEST
ISO 11126-10
** pH Value (40% solution) US EPA 9040 B - 7.4
** Specific Conductance, µS/cm ISO 11127-6 - 15
** Moisture Content, % ISO 11127-5 0.2 Max. 0.1
** Conductivity, µS/cm ASTM D 4940 250 Max. 25
** Water Soluble Chlorides, ppm ISO 11127-7 25 Max. 5
** Hardness, Mohs ISO 11127-4 6 Min. >6
** Apparent Density, Kg/m³ ISO 11127-3 4000-4200 4125
** Oil, grease, Hydrocarbon Residue,
n-hexane extract - Nil
%
** Sulphur, % C&S Analyzer - 0.007
** Free Silica, % APHA 3120B - <0.005
** Free Iron, % APHA 3120B - <0.005
** Copper, % US EPA SW 846/6010 B - <0.005
** Heavy Metals, % US EPA SW 846/6010 B - <0.005
HEAVY METALS
** Antimony, % US EPA SW 846/6010 B - <0.005
** Arsenic, % US EPA SW 846/6010 B - <0.005
** Barium, % US EPA SW 846/6010 B - <0.005
** Beryllium, % US EPA SW 846/6010 B - <0.005
* Cadmium, % US EPA SW 846/6010 B - <0.005
* Lead, % US EPA SW 846/6010 B - <0.005
* Nickel, % US EPA SW 846/6010 B - <0.005
** Selenium, % US EPA SW 846/6010 B - <0.005
* Silver, % US EPA SW 846/6010 B - <0.005
Comment: The above tested material meets the requirement of ISO 11126-10 for the above tested
parameters.
Checked by Approved by
LTISLrkkqrIIRYDS0020XAJZH2MDIMZCHMCZNJPAMRKBGN3003 LTISLrkkqrIIRYDS0020XAJZH2MDIMZCHMCZNJPAMRKBGN3003
Name Wasiur Rahman Khan
LGWGO0OAEER35399711758630OCTOBER2023CR34946VSGOWQ Name Charles Fernandes
LGWGO0OAEER35399711758630OCTOBER2023CR34946VSGOWQ
OCRUAVZLZN3SNXT57ZYHLD6H6X1PJV5XPNGOX73FWX28HTB OCRUAVZLZN3SNXT57ZYHLD6H6X1PJV5XPNGOX73FWX28HTB
Designation Chemical Analyst
DOS6UW13Q1OIUR4IOBJHL4WK4X0P36IUUP7KGX8OQCZIOCM4 Designation Asst. Chemistry Manager
DOS6UW13Q1OIUR4IOBJHL4WK4X0P36IUUP7KGX8OQCZIOCM4
8HJTMQWHLTVX3JYLQW2AOD6FOJ09HJPCEKIQXECGI2HJH7A 8HJTMQWHLTVX3JYLQW2AOD6FOJ09HJPCEKIQXECGI2HJH7A
H82TCPSKX0J249MUZDDN0YA29YKT5KGXXLTM7C99F4LU607G H82TCPSKX0J249MUZDDN0YA29YKT5KGXXLTM7C99F4LU607G
Signature WF5JFICR7MMIA9HUMDOBLV4FHYH6ZII5EPCL2SO48G4HLR41 Signature WF5JFICR7MMIA9HUMDOBLV4FHYH6ZII5EPCL2SO48G4HLR41
H95SWBVDENQF0UWLCZ3C25ZVTTS7N8HZ8NZWTEJSD312NKQ H95SWBVDENQF0UWLCZ3C25ZVTTS7N8HZ8NZWTEJSD312NKQ
LF8UOW4XA3Y0KJCDNAPCT8GEP24FQQQG91NWJDEABLZGDQ LF8UOW4XA3Y0KJCDNAPCT8GEP24FQQQG91NWJDEABLZGDQ
WFNTDWW14BIDAEMUDJ4LW3WRNYWPS6ZCTDVIBMRURRFX WFNTDWW14BIDAEMUDJ4LW3WRNYWPS6ZCTDVIBMRURRFX
B67SUG7WK9IKEKI62VDYOEVM1EO5B B67SUG7WK9IKEKI62VDYOEVM1EO5B
QC SEAL MANDATORY Page 1 of 1
* Accredited Tests
** Non Accredited Tests
Report ID#:CR34946-EN-S1
Report Date#:30-OCT-2023
Job ID#:353997
TERMS AND CONDITIONS
Lonestar Technical Services (L.L.C.) (LTS-Dubai) and Lonestar Technical & Industrial Services (L.L.C.) (LTIS-Abu
Dhabi) provides Testing, Analyses, Investigation and Inspection services in accordance with its applicable Test
Method and Standard Operating Procedure (SOP) which is subjected to the following terms and conditions:
1. LTS/LTIS shall follow internationally accepted methodologies for performing testing, analyses, investigation and inspection services. In
the absence of specific request from the client, L TS/LTIS Laboratories have the freedom to adopt any National / International Standard
Specification for conducting the requested tests. If a standard specification is not available, LTS/LTIS shall follow a Standard Operating
Procedure (SOP) developed by the Laboratory.
2. The results reported are only for the sample(s) analyzed / tested. Conclusions and recommendations are not part of ENAS / EIAC
Accreditation. Conformance to specification is provided as mutually agreed upon decision rule.
3. Testing and reporting pertains to the sample(s) tested and does not constitute endorsement of the product by LTS/LTIS.
4. The test report issued by LTS/LTIS contains sample identification as provided by the client. LTS/LTIS does not independently verify the
authenticity of the sample identification, unless LTS/LTIS Technician(s) are involved in the sampling.
5. The test report shall not be used in full or in part for any promotional or publicity purposes without the written consent of LTS/LTIS.
6. Under no circumstances LTS/LTIS accepts any liability for loss or damage, consequential or otherwise, caused by use or misuse of the
Test Results. LTS/LTIS liability is strictly limited to the testing fee charged for the sample in question, in case of proven negligence by L
TS/L TIS.
7. In case of cancellation of order by the client for any reason, all costs incurred including incidental expenses, if any shall be charged to
the client.
8. It is the policy of Lonestar to ensure that accredited status is described in a manner that does not imply accreditation in areas that are
outside the actual scope of accreditation. All requests for proof of accreditation include the scope of the accreditation as well as the
certificate.
9. Lonestar Dubai is Accredited to ISO/IEC 17025:2017 by GCC Accreditation Center (GAC) with Certificate No. ATL 0042 while Lonestar
Abu Dhabi is Accredited to Emirates National Accreditation System (ENAS) with Certificate No. NAL 046 respectively. The most recent
issue of the schedule of GAC accreditation of Lonestar Dubai is available from the GAC website www.gcc-accreditation.org
10. Full details of Lonestar-Abu Dhabi ENAS NAL 046 accreditation scope (Testing) and ENAS NAI 085 accreditation scope (Inspection) can
be obtained from the laboratory's schedule of accreditation issued by ENAS and both are available from ENAS website www.enas.gov.ae
11. Lonestar (Lonestar Dubai-LB-TEST-019 & Lonestar Abu Dhabi-LB-TEST-122) are also accredited under the Laboratory Accreditation
Program of Emirates International Accreditation Center (EIAC). Full details of EIAC accreditation can be obtained in the EIAC directory
of accreditation for testing laboratories available from EIAC website www.eiac.gov.ae
12. Lonestar Technical Services (L.L.C.) (LTS-Dubai) and Lonestar Technical & Industrial Services (L.L.C.) (L TIS-Abu Dhabi) are ISO 9001 :2015,
14001 :2015 and 45001 :2018 certified companies.
13. If you have any complaints pertaining to our services, please send your concerns to [email protected]. Complaint handling
procedure is available with QHSE Manager.