MAC 5 Lite data sheet™
General Specifications for digital acquisition and analysis of waveforms
Analog to digital 24-bit analog to digital conversion
Instrument type Microprocessor augmented automatic conversion resolution
electrocardiograph; 10-lead wire acquisition
Over sampled rate: 512 ksps
with programmable lead configuration
Down sampled ECG Bandwidth: 0.04 to 300 Hz*
ECG interpretation Marquette™ 12SL™ ECG analysis program
waveform Sample rate: 2 ksps
for adults and pediatrics
Resolution: 1.22 µV
Computerized 12-lead analysis includes measurements
Input to 12SL Bandwidth: 0.04, 0.56 ZPD to 300 Hz*
measurements
Sample rate: 1 ksps
Heart rate meter 30 to 300 BPM ±10% or 5 BPM, whichever is Resolution: 4.88 µV
greater — heart rates outside this range will
Additional report 20 Hz, 40 Hz, 100 Hz, 150 Hz or 300 Hz*
not be displayed
filters
ECG data formats GE Hi-Fidelity ECG, XML
Specification for stored / transmitted waveforms
External archiving USB removable media
Digital rhythm Bandwidth: 0.04, 0.56 ZPD to 300 Hz*
Pre-acquisition Provides 10 seconds of instantaneous
waveform Sample rate: 1000 sps
ECG acquisition
Resolution: 4.88 µV
Digital rhythm Up to 5 minutes of continuous rhythm storage
12-lead ECG Bandwidth: 0.04, 0.56 ZPD to 300 Hz*
(exportable as a PDF)
waveform Sample rate: 500 and 1000 sps
Full disclosure Review up to 5 minutes of 12 Lead ECG, ability Resolution: 4.88 µV
to select 10 second Resting ECG records,
Representative Sample rate: 500 and 1000 sps
ability to generate 5 minute single lead full
(median) complex Resolution: 4.88 µV
disclosure report
Storage 300 records consisting of 10 second Resting Pace detection
ECG and rhythm records; 200 minutes Digital Pacemaker Sample rate: 75 ksps
Rhythm or Full Disclosure records waveform
Dynamic range AC differential ± 10 mV Pace detection Duration: 0.2 ms to 2.1 ms
DC offset ±600 mV Amplitude: 2 mV to 700 mV
Common mode >125 dB (>100 dB with AC filter disabled) Separation: 1 ms or greater
rejection Pace annotation Dedicated pace channel on display and
Input impedance >50MΩ @ 10 Hz printed reports (configurable)
Defibrillation Per IEC 60601-2-25:2011
protection
Patient leakage <10 µA
Communications Writer
ECG management MUSE™ Cardiology Information System Network printer Support printing to network printer
systems connectivity Compatible (v8 or later) with bi-directional
orders and ADT support; Transmit Resting ECG
records to Cardiosoft™ via removable media
Electrical
(v6.73 or later) or via network (v7 or later) Power supply AC mains or battery operation
DICOM Modality worklist/orders: supported via Input voltage 100-240 VAC + 10%
GE HealthCare MUSE (v8 or higher) and DICOM
Input frequency 50-60 Hz + 3 Hz
Gateway with bi-directional orders support
Battery type Replaceable and rechargeable internal battery
EMR connectivity Via MUSE cardiology information system
(v8 or later) with EMR Gateway Battery capacity Minimum 180 minutes with acquiring
and printing a single page ECG report
Data export Export of Resting ECG (in PDF or XML format),
every 15 mins (with five minutes auto
Digital Rhythm and Full Disclosure reports
standby enabled and all accessories
(in PDF format) over Secures File Transfer
connected, except KISS)
Protocol (SFTP) or to a Shared folder
Battery charge Approximately 240 minutes from total time
Wireless Wireless 802.11 a/b/g/n wireless connectivity
discharge when device is off or standby
(2.4 GHz/5GHz)
IPV4
Security and privacy
DHCP, hostname and static IP options for
configuring device IP/network address Encryption All files containing PHI, local users and
WEP and enhanced security WPA-PSK, passwords
WPA2-PSK, WPA/WPA2 enterprise protocols Login Network: LDAP/Active directory
TLS, PEAP-MSCHAPV2, PEAP-GTC, TTLS- authentication Local: User database
MSCHAPV2, TTLS-GTC. (PEAP requires network
User management Customizable roles for limiting system access
evaluation/approval prior to purchase)
by user groups for Admin, Clinical,Service,
Ultra-high security 4096 bit encryption/long Biomed, and user defined up to 10
certificate support customized roles
SHA1 and SHA2 support Audit trail All user logins, logouts and login failures,
Network 802.3 Ethernet interface via RJ45 connectivity file deletions, file changes, file views,
connector file acquisitions, file transmissions, file
printouts, system configuration changes
Compatible to 10Base-T, 100Base-T LAN
PHI access Controlled by customizable roles with
IPV4
configurable advanced strict PHI access rules
DHCP, hostname and static IP options for
PHI access logs Detailed and exportable logs of all PHI
configuring device IP/network address
viewing by users
Network clock Network time synchronization (NTP)
Emergency access This user can access the device without
(STAT mode) providing login credentials to perform
Display emergency tasks such as acquiring an
ECG or rhythm while preventing access
Display and 8.9” diagonal, LED backlit, 892 x 558 pixels to any stored patient data, orders, ADT,
resolution or 3rd party applications
Touch screen type Projected Capacitive (PCAP) multipoint touch USB lockout Software controls to disable USB
input that works while wearing medical ports/connections
exam gloves
Display data Heart rate, patient name, patient ID, date,
clock, battery power indicator, scrolling
waveforms, lead labels, speed, gain and
filter settings, warning messages, prompts,
hookup advisor and help messages
Physical specifications Cleaning
Approved cleaning Soap and water solution
Weight and dimensions agents Sodium hypochlorite (NaOCl) 5% solution
Ethanol (ethyl alcohol) 96% (v/v)
Max weight 2.3 kg
Isopropyl alcohol 70% (m/m)
Max height 95 mm
Hydrogen peroxide 20% (v/v)
Max width 320 mm
Phenol 2% (V/V)
Max length 270 mm
FDA cleaning agent Super Sani-Cloths
for efficacy
Environmental specifications
Temperature Certification
Operating 50° to 104° F (10° to 40° C) Certification marks cTUVus
Transport/Storage –4° to 140° F (–20° to 60° C) Standards EN 60601-1:2006/A1:2013
complied with EN 60601-1-2:2007 +AC 2010
Humidity
EN 60601-1-2:2015
Operating 20% to 95% RH non-condensing EN 60601-2-25:2015
Transport/Storage 15% to 95% RH non-condensing IEC 62366-1:2015
EN 62304:2006+A1:2015
Pressure
Pharma mode* Support 21CFR Part 11 clauses for the
Operating 70 to 106 kPa control of electronic records in closed
Transport/Storage 50 to 106 kPa systems when Phrama mode option
is activated. No support for electronic
Input devices signature
Keyboard Touch keyboard
Touchscreen 8.9”, 892 x 558 pixels projected Ordering information
Capacitive (PCAP) multipoint touch input that
works while wearing medical exam gloves Available user Chinese, Danish, Dutch, English, French,
interface languages Finnish, German, Italian, Norwegian,
Barcode External barcode scanner (optional)
Swedish, Korean, Japanese, Russian,
Mouse Supported but not included Spanish, Portuguese, Brazilian
Portuguese, Polish
External USB barcode scanner
Types Fixed and variable length
Symbologies Code-128, PDF417, Code 39, Interleaved
Code 2 of 5, and Data Matrix symbology
for characters A-Z (upper case), a-z
(lower case), and 0-9 for all supported
languages
* The feature is not supported in China.
© 2023 GE HealthCare
Not all products or features are available in all markets. Contact a GE HealthCare Representative for more information. Please visit
www.gehealthcare.com. Data subject to change. 12SL, CardioSoft, MAC, Marquette, and MUSE are trademarks of GE HealthCare.
GE is a trademark of General Electric Company used under trademark license.
MAC 5 Lite