0% found this document useful (0 votes)
12 views20 pages

Aladdin B

The Aladdin is a comprehensive optical biometry and corneal topography system designed for cataract surgery, featuring 9-in-1 functionalities including IOL calculations and wavefront analysis. It offers advanced tools like the RX/AL Trends Module for monitoring refractive changes and an onboard Barrett IOL Calculation Suite for precise IOL power predictions. The system also includes customizable IOL databases, pupillometry, and detailed reporting capabilities to enhance surgical outcomes.

Uploaded by

sukhisinghaccnts
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
12 views20 pages

Aladdin B

The Aladdin is a comprehensive optical biometry and corneal topography system designed for cataract surgery, featuring 9-in-1 functionalities including IOL calculations and wavefront analysis. It offers advanced tools like the RX/AL Trends Module for monitoring refractive changes and an onboard Barrett IOL Calculation Suite for precise IOL power predictions. The system also includes customizable IOL databases, pupillometry, and detailed reporting capabilities to enhance surgical outcomes.

Uploaded by

sukhisinghaccnts
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 20

Aladdin

Optical Biometry & Topography System


Select the Right
IOL for Your
Patients
The Aladdin is an easy-to-use, combination
optical biometer and full corneal
topographer. 9-in-1 features include optical
coherence biometry, Placido topography,
wavefront analysis of the cornea, IOL
calculation suite, pupillometry, DICOM
connectivity and the NEW RX/AL
Trends Module.
Aladdin Features

Overview

Keratometry, Posterior & Anterior Aberrometry


Topography Interferometry Analysis (Zernike)

White to White Comprehensive Pupillometry


Measurement Reports

IOL & Toric IOL RX/AL Trends


Calculation Module

Posterior & Anterior interferometry

Biometry results are complemented with anterior


topography, Zernike analysis and pupillometry in one
fast, accurate and easy acquisition. The Interferometer of
ALADDIN also provides anterior measurements such as the
Central Corneal Thickness (CCT), Anterior Chamber Depth
(ACD) and Lens Thickness. You get the complete picture
for all cataract surgeries. Whether you are performing
standard cataract surgery or premium IOL implantation,
CCT
you will be screening for corneal aberrations and previous
corneal refractive surgery procedures all at once. ACD LT
AL
The ALADDIN only requires just one Acquisition.
Are you focusing on
refractive changes?
Experience the Aladdin RX/AL Trends Module:
The precise tool to monitor longitudinal
changes in the eye.
RX/AL Trends Module

RX/AL Trends Module

・ Measures and displays trends in AL changes

・ Allows you to monitor change progression

・ Charts and tracks refractive variations

・ Provides comprehensive printouts

Trend Monitoring

By combining manually entered refractive


information with biometric data obtained
by low-coherence interferometry, the
Aladdin provides a quantitative report of the
progression of changes in the eye’s
refractive power.

After the refraction values are entered, the


Aladdin performs 7 critical measurements
and provides a numerical analysis of the
trends of the eye parameters related to
changes in the axial length, corneal curvature,
anterior corneal wave front analysis and
other dimensional variations. Changes can
be followed in periods of 3, 6 and 12 months
providing a trend that can be used to track
the progression of certain eye conditions.
Onboard Barrett IOL
Calculation Suite

Onboard Barrett IOL


Calcuation Suite

Dr. Graham D. Barrett developed the Barrett


formula in 2013 and takes into account the
posterior cornea considering the lens position
for each individual patient instead of calculating
IOL power by estimating lens thickness based
on patient’s age. The Barrett formula uses the
Universal II, which is a method of predicting IOL
power to work out where the lens is and utilizes
that information to calculate the effect of the
cylinder power at the cornea. The Universal II
formula was also developed by Dr. Barrett. Dr.
Barrett’s formula considers the thickness and The Aladdin’s Barrett IOL Calculation Suite

shape of the lens as well, which provides a more includes the Barrett Rx, the Barrett Toric

sophisticated way of predicting and translating Calculator Formula, the Barrett True K and

the cylinder power. The formula is able to predict the Barrett Universal II formulae.

posterior corneal curvature without actually


measuring it.
The Aladdin HW3.0

Onboard Olsen Formula

The Aladdin HW3.0 provides precise


measurements of the internal structures of the
eye including Central Corneal Thickness and
Crystalline Lens Thickness. Those measurements
used in combination with the on‑board Olsen
IOL calculation formula provides accurate IOL
power calculations in virtually all types of eyes
regardless of size. The Olsen formula utilizes a
newly developed concept by Dr. Olsen called
the C-constant which predicts the Effective Olsen Formula
Lens Position (ELP) when performing in-the-
bag IOL implants. This model also predicts the
lens position of anterior chamber IOLs. The
C-constant approach performs independently
of other conventional measurements such as
axial length, keratometry, white-to-white length,
IOL power, etc. It will provide accurate IOL
calculations in any type of eye.

Abulafia-Koch astigmatism cylinder


correction for Toric IOL calculations
incorporated

The Abulafia-Koch correction formula calculates


the estimated total corneal astigmatism based on
standard keratometry measurements.
IOL & Toric IOL
Calculation
The ALADDIN guides you through the choice of the right IOL

for each patient. A combination of IOL brand, type and formulae

can be viewed and compared to various chosen combinations,

in order to obtain the best post-operative Visual Acuity result

for the patient.

A pre-defined IOL selection can be programmed for each individual surgeon.


When implanting a toric IOL, specific toric calculation software assist you in calculating the best option.
This integrated toric IOL calculator saves you time and avoid unnecessary mistakes when manually
entering data online. IOL Toric Rotation Simulation Software calculates the induced spherical and
cylindrical power for every five degrees toric IOL rotation.
IOL & Toric IOL Calculation

Post refractive IOL

In eyes that have previously undergone


refractive surgery such as RK, PRK, Lasik,
Lasek, LK and PTK, spherical aberrations are
often outside the standard values. Aladdin's on
board Barrett True-K, True-K Toric, Camellin-
Calossi and Shammas No-history formulae
provide the tools for post-refractive IOL
calculations.

Customisable IOL database

The ALADDIN provides a full database which


can be upgraded and customised. You can
manually upgrade the A- constant for each
individual IOL to obtain even a higher accuracy
every time you perform cataract surgery.
Your favorite IOL’s can be pre-defined and
programmed for each individual surgeon,
simplifying and personalising IOL selection.
Keratometry / Topography

Full Corneal topography provides much more


information than just K-values. Specific data
for toric IOL surgery, instantly detects regular
and irregular astigmatism. The keratometry
provided by the placido rings of ALADDIN is
extremely accurate due to simultaneous use
ofthe interferometer.

・ Axial and tangential map


・ Absolute and normalized scale
・ Milimeters or diopters
・ Grid, rings, and 3, 5 and 7 mm zones

Pupillometry

During Placido evaluation pupillary response


is observed to assess a pseudo Photopic and
pseudo Mesopic pupil size, indicating response
and normal range of the pupil. Full pupillometry
screening assists to evaluate eyes for multifocal
IOL implantation or refractive surgery. For any
refractive procedure it is vitally important to
diagnose the pupil very carefully in different
light conditions, and exclude cases of extreme
small or decentered pupils.

・Dynamic
・Photopic
・Mesopic

Aberrometry analysis (Zernike)

Zernike analysis of the topographic data


provides the Optical Path Difference (OPD)
and information on astigmatism, spherical
aberrations, higher order aberrations and
Coma for pupil sizes of 2.5mm to 7.0mm
Aladdin Features

Axial length

Using a low-coherence interferometry system


with a super luminescent diode of 850 nm and
signal processing, the ALADDIN achieves Axial
length measurement with high signal-to-noise
ratio and is able to penetrate even high grade
dense cataracts. Axial length measurements can
be done on normal eyes as well as on aphakic,
pseudo-aphakic and silicone oil-filled eyes.

Anterior biometry

Anterior biometry with the ALADDIN allows


measuring the Central Corneal Thickness,
Anterior Chamber Depth and the crystalline
Lens Thickness. Pachymetry is a key feature to
measure for all cataract surgery procedures.
ACD is measured through interferometry.
providing high precision and reproducibility.
All interferometry measurements are shown in
a graph to make it visible.

White to white

ALADDIN measures automatically white to


white dimension which can be manually edited.
Reliable white to white measurement is used
with anterior chamber intraocular lens and
sulcus fixated posterior chamber intraocular
lens in highly myopic eyes.
Report Samples
Report Samples
Report Samples
Topcon’s Cataract Workstation

Cataract surgery quality control VA Simulation Premium IOL


Visual acuity (VA) is the most common clinical KR-800S offers a Spherical Equivalent mode
measure of the quality results of cataract surgery. which can simulate the benefit of a premium
It is how we describe and measure the success (toric) IOL, to educate the patient on the
of surgery and it is therefore critical that it is advantages of a better post-operative VA.
measured well. Measurement of VA must be The subjective VA test for nearwill assist the
standardized and systematic. Topcon’s KR-800S patient in considering a Multifocal IOL.
Auto Kerato- Refractometer with subjective VA
check will do exactly that. With the KR-800S
the VA can be subjectively tested pre- and post- Cataract workstation
operative cataract surgery. With the unique The KR-800S completes the screening workflow
features of the KR-800S such as “Glare” test of cataract surgery. All necessary cataract pre-op
and “Contrast” test you can even evaluate information can be obtained by KR-800S and
the progression of cataract and distinct Nuclear ALADDIN, while the KR-800S assist you post-op
cataract from Cortical cataract. in Visual Acuity evaluation and the success of the
cataract surgery. ALADDIN and KR-800S the
perfect combination for your cataract practice.

KR-800S Aladdin Cataract KR-800S


PRE-OPERATIVE Pupillography Surgery POST-OPERATIVE
Subjective Refraction Topography Subjective Refraction
and Pre-OP-diagnostics Biometry inkl. K1 & K2 and Post-OP-diagnostics
IOL Calculation

Aladdin KR-800S
Optical Biometry & Auto kerato refractometer
Topography System with subjective function
Technical Specifications of Aladdin

Measurement range for IOL


Axial Length (Interferometry) Super luminescent diode 830nm, 15 mm - 38 mm
Corneal Radii 5.00mm – 12.00mm / 28.00D - 67.50D
ACD measurement Interferometer 1.5mm – 6.5mm
WTW measurement 6,0 mm- 18,0 mm
Pupillometry Dynamic, Photopic & Mesopic, pupil size 0.5 mm - 10 mm
Lens Thickness (interferometry) 0.5mm – 6.5mm
CCT measurement (interferometry) 0.300mm – 0.800mm

On-board calculation formulas


IOL formulas Haigis, Hoffer Q, Holladay 1, SRK®II, SRK®T, Barrett, Universal II, Olsen
Post Refractive Surgery IOL formulas Camellin Calossi and Shammas No History, Barrett True K, Barrett Rx

Placido Topography specifications


Keratoscopic Cone (topographic map) 24 rings on a 43 dpt sphere, working distance 80 mm
Points analysed Over 100,000
Points measured 6,200
Cornea coverage up to Ø 9,8 mm (on a 8 mm sphere) 42.2 dpt with N=1.3375
Guided focus system Yes

Keratoconus screening
Apical Curvature Yes
Apical Gradient of Curvature Yes
Symmetry index Yes

Software features
Toric IOL calculator Generic Toric IOL, Oculentis Toric IOL
Zernike analysis Pupil size 2.5 mm - 7.0 mm
Print to USB printer, Network printer, PDF to shared network folder & PDF to USB drive

Instrument Specifications
Display 10.1” touch screen
Storage 320 GB HDD + 32 GB SSD
Operating system Windows 10
Processor AMD G-T56N
Internal memory 2GB RAM
Power input AC 100 – 240V 46-63 Hz
Dimensions 320 mm (W) x 490 mm (H) x 470 mm (L)
Weight 18 kg
Connections 1 x LAN, 2 x USB
Supports USB Barcode scanner, External USB keyboard / mouse
Marking CE, ETL

Reports
Aladdin report Yes
Measurement overview Yes
Pupillometry Yes
IOL Yes
Generic Toric IOL Yes
Oculentis Toric IOL Yes
* Not available in all countries, please check with your distributor for availability in your country
* Subject to change in design and/or specifications without advanced notice
VISIA IMAGING S.R.L.
Via Martiri della Libertà 95/e
IMPORTANT In order to obtain the best results with this instrument, please be sure to review all user instructions prior to operation. 52027 San Giovanni Valdarno (AR) Italy

Topcon Healthcare | topconhealthcare.com | 111 Bauer Drive, Oakland, NJ 07436


MCA#4198

You might also like