Samsung LED IW008C 115832
Samsung LED IW008C 115832
* The configuration information in this document is for simulated installation only, while actual physical specifications
may vary. Please consult with Samsung or your installation partner for accurate information.
* Specifications are subject to change without notice.
1/26
Date of configuration : 23rd May, 2025
Innovation doesn’t rest. It is a relentless pursuit to create unrivaled experiences. An ambition to inspire others
with greatness. This unending quest has culminated in Samsung pushing the boundaries of innovation yet again.
Based on a rich heritage of R&D and accumulated expertise, the potential of The Wall can now be fully realized.
A display that transforms the existing concept of LED screen. A display that goes beyond anything else available
in the market today. The Wall makes a bold, breathtaking statement like no other. The possibilities are endless.
And its potential is limitless.
2/26
LED Configuration Rendering
3/26
Screen Specifications
Area 7.315 m²
Screen Specifications
Diagonal 155.221 inch
4/26
Screen Components
SBB-SNOWAAE 1 Unit
S-Box
CY-IGAOFS 1 Unit
VG-WR00PKIT(110V) 1 Unit
Power Cord
VG-WR00PKIT(220V) 1 Unit
VG-LFC55SWW 1 Unit
Frame Kit
VG-LFC11SWW 5 Units
VG-LFC44SEW 1 Unit
Deco Kit
VG-LFC11SEW 1 Unit
5/26
Ventilation Guide (A case Dynamic Peaking function is activated)
(CFM)
30°C 45 180
6/26
Ventilation Guide (A case Dynamic Peaking function is deactivated)
(CFM)
30°C 35 140
7/26
Product Specification
8/26
Product Specification
9/26
Mechanical Overall Depth Drawing(Cabinet)
10/26
Mechanical Drawing(Cabinet)
11/26
Mechanical Drawing(SNOWAAE)
12/26
Mechanical Drawing(IG SNOWAAE)
13/26
Mechanical Drawing(Frame Kit)
VG-LFC55SWW
14/26
Mechanical Drawing(Frame Kit)
VG-LFC11SWW
15/26
Mechanical Drawing(Frame Kit)
(mm)
3225.6
806.4
16/26
Mechanical Drawing(Deco Kit)
VG-LFC44SEW
17/26
Mechanical Drawing(Deco Kit)
VG-LFC11SEW
18/26
Power Flow Diagram(110V, Front View)
19/26
Power Flow Diagram(110V, Rear View)
20/26
Power Flow Diagram(220V, Front View)
21/26
Power Flow Diagram(220V, Rear View)
22/26
Data Flow Diagram(S-Box Port : N-Order)
1 3
2 4
Number S-Box Port Number
S-Box unit
23/26
Data Flow Diagram(Front View)
*In case of 1 width setup, if you install more than 1 x 3 setup IG should be installed as above to ensure data redundancy.
Data Link
Primary
Redundant
24/26
Data Flow Diagram(Rear View)
*In case of 1 width setup, if you install more than 1 x 3 setup IG should be installed as above to ensure data redundancy.
Data Link
Primary
Redundant
25/26
Production Information
IW008C SBB-SNOWAAE