Section 2 CP
Section 2 CP
SYS19: BASE2 JOB: CRMAIN06-0267-11 Name: CP-267 DATE: JAN 19 2006 Time: 5:13:35 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
Myers Scru-titeTM and Ground hub are used in the HUB BASIC SCRU-TITE® – NEMA 2, 3, 3R, 4, 4X and 12
termination of electrical circuits through wall of the ZINC – Optional nickel-chrome plate finish available.†
ɀ CP Myers Hubs
enclosure UL File No. E-27258 Unit Standard Weight Lbs.
Cat. # Size Quantity Package Per 100
Features ST-03† 3⁄8⍯ 25 250 12
ɀ Vibration proof ST-1† 1⁄2⍯ 25 375 20
ɀ Grounding screw for added safety 3⁄4⍯
ɀ Captive o-ring gasket ST-2† 25 250 32
ɀ No welding ST-3† 1⍯ 25 250 40
ɀ Posi-Lok insulated throat (insuliner) ST-4† 11⁄4⍯ 10 100 60
ɀ Fit standard knockouts ST-5† 11⁄2⍯ 10 100 70
ɀ Easy installation ST-6† 2⍯ 10 60 90
ɀ Controlled thread lengths ST-7 21⁄2⍯ 5 50 200
ɀ NPSL on male thread ST-8 3⍯ 2 30 250
ɀ No sharp edges (along parting line) ST-9 31⁄2⍯ 2 12 300
ST-10 4⍯ 2 12 350
Material ST-11* 5⍯ 1 8 600
ɀ Nut: Zamek-2, Zamek-3, Aluminium (Al 360), Stainless (316)
ɀ Body: Zamek-2, Zamek-3, Aluminium (Al 360), Stainless (316) ST-12* 6⍯ 1 8 800
* not supplied with insulator.
ɀ Insuliner: Lexan
ɀ O-Ring: Gasket Vi Ton HUB BASIC SCRU-TITE® – NEMA 2, 3, 3R, 4, 4X and 12
ɀ Ground Screw: steel ALUMINUM
UL File No. E-27258
Standard Finishes STA-1 1⁄2⍯ 25 375 8
ɀ Aluminum: Natural STA-2 3⁄4⍯ 25 250 16
ɀ Zinc: Natural STA-3 1⍯ 25 250 16
Optional Material/Finishes STA-4 11⁄4⍯ 25 100 30
ɀ Stainless: Natural STA-5 11⁄2⍯ 10 100 30
ɀ Aluminium: PVC STA-6 2⍯ 10 60 50
ɀ Zinc: Chrome-plate, PVC STA-7 21⁄2⍯ 5 50 80
STA-8 3⍯ 2 30 100
Certifications STA-9 31⁄2⍯ 2 12 150
NEC/CEC: Class I, Division 2
Class II, Division 1 & 2 STA-10 4⍯ 2 12 150
Class III, Division 1 & 2 STA-11 5⍯ 1 8 300
UL Listed - UL Standard 514B STA-12 6⍯ 1 8 300
CSA Certified - Certified by UL to CSA standard C22.2 No. 18 STAINLESS STEEL GROUND HUB – NEMA 2, 3, 3R, 4, 4X and 12
NEMA Type 2, 3, 3R, 4, 4X, 12 (std hub) STAINLESS STEEL – Type 316
NEMA Type 2, 3, 3R, 4, 12 (ground hub) UL File No. E-59509 Weight
Unit Standard Lbs. Per
Cat. # Size Quantity Package 100
SSTG-1 1⁄2⍯ 10 10 20
SSTG-2 3⁄4⍯ 10 10 30
SSTG-3 1⍯ 10 10 43
SSTG-4 11⁄4⍯ 5 5 55
SSTG-5 11⁄2⍯ 5 5 73
SSTG-6 2⍯ 5 5 95
SSTG-7 21⁄2⍯ 2 2
SSTG-8 3⍯ 2 2
SSTG-9 31⁄2⍯ 2 2
SSTG-10 4⍯ 2 2
Applications: Ideal for pharmaceutical, chemical and food
processing, pulp/paper and nuclear industries. Resistant to a variety
of chemicals, including acetic, citric and salt water. The O-ring is a
special ‘‘Viton (75)’’ and has excellent chemical resistance. Hub is
provided with a stainless steel ground nut.
† Optional Nickel-Chrome Plate Finish, add suffix ‘‘-CP’’. See price list.
STIBOINFO((CRH:66008com:CP:267))
PDFINFO CH0 9 F - 3 3
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0268-4 Name: CP-268 DATE: JAN 19 2006 Time: 5:13:38 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
GROUND NUT
GROUND HUB – NEMA 2, 3, 3R, 4, 4X and 12 ZINC
ZINC Max. Copper
ɀ CP Myers Hubs
UL File No. E-59509 Catalog Unit Std. Weight Lbs. Grd. Wire Size
Weight Max. Copper Number Size Quantity Pkg. Per 100 CSA UL
Unit Std. Lbs. Per Grd. Wire Size STGN-1 1⁄2⍯ 25 375 6 #8 #8
Cat. # Size Quantity Pkg. 100 CSA UL STGN-2 3⁄4⍯ 25 375 10 #8 #8
STG-1 1⁄2⍯ 25 325 20 #8 #8 STGN-3 1⍯ 25 375 13 #8 #8
3⁄4⍯
STG-2 25 225 30 #8 #8 STGN-4 11⁄4⍯ 10 150 15 #8 #8
STG-3 1⍯ 25 150 43 #8 #8 STGN-5 11⁄2⍯ 10 150 23 #6 #8
STG-4 11⁄4⍯ 10 100 55 #8 #8 STGN-6 2⍯ 10 150 30 #4 #8
STG-5 11⁄2⍯ 10 90 73 #6 #8
STG-6 2⍯ 10 60 95 #4 #8 GROUND NUT
ALUMINUM
STG-7 21⁄2⍯ 5 35 190 #2 #6 1⁄2⍯
STAGN-1 25 375 3 #8 #8
STG-8 3⍯ 2 26 263 1/0 #6 3⁄4⍯
STAGN-2 25 375 5 #8 #8
STG-9 31⁄2⍯ 2 12 300 2/0 #6
STAGN-3 1⍯ 25 375 6 #8 #8
STG-10 4⍯ 2 12 350 2/0 #4
STAGN-4 11⁄4⍯ 10 150 8 #8 #8
STG-11* 5⍯ 1 8 625 2/0 #2
STAGN-5 11⁄2⍯ 10 150 10 #6 #8
STG-12* 6⍯ 1 8 750 3/0 #1 STAGN-6 2⍯ 10 150 13 #4 #8
* Not supplied with insulator
STIBOINFO((CRH:66008com:CP:268))
PDFINFO CH0 9 F - 3 4
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0269-12 Name: CP-269 DATE: JAN 19 2006 Time: 5:14:12 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
Myers® CP
Hubs
ɀ CP Myers Hubs
Weight Weight
Unit Standard Lbs. Per Unit Standard Lbs. Per
Cat. # Size Quantity Package 100 Cat.† Size Quantity Package 100
STTBA-1 1⁄2⍯ 5 75 20 SSTM-1 M20 to 1⁄2⍯ 10 10 12
STTBA-2 3⁄4⍯ 5 75 35 SSTM-2 M25 to 3⁄4⍯ 10 10 20
STTBA-3 1⍯ 5 75 30 SSTM-3 M32 to 1⍯ 10 10 32
STTBA-4 11⁄4⍯ 5 50 40 SSTM-4 M40 to 11⁄4 ⍯ 5 5 40
STTBA-5 11⁄2⍯ 5 50 50 SSTM-5 M50 to 11⁄2⍯ 5 5 50
STTBA-6 2⍯ 5 25 70 SSTM-6 M63 to 2⍯ 5 5 70
STTBA-7 21⁄2⍯ 4 20 106
STTBA-8 3⍯ 2 20 138 CONDUIT HUBS – MALLEABLE IRON
(Insulated Throat)
THROUGH-BULKHEAD FITTING without nipples
ZINC Features:
STTTB-1 1⁄2⍯ 5 75 35 ɀ Male thread type
STTTB-2 3⁄4⍯ 5 75 60 ɀ Tapered female thread for rigid conduit and IMC
STTTB-3 1⍯ 5 75 75 ɀ Recessed O-ring gasket assures raintight
STTTB-4 11⁄4⍯ 5 50 85 and dust tight connections
STTTB-5 11⁄2⍯ 5 50 120 ɀ Insulated throat provides smooth pulling surface
STTTB-6 2⍯ 5 25 170 ɀ Locking screw on the nut doubles as a grounding screw for added safety
ɀ Complete size range from 1⁄2⍯ to 6⍯
THROUGH-BULKHEAD FITTING without nipples ɀ Hubs fit standard knockouts. No special tools required
ALUMINUM Certifications and Compliances:
STTTBA-1 1⁄2⍯ 5 75 15
ɀ Class I, Division 2 – NEC 501.4(B)
STTTBA-2 3⁄4⍯ 5 75 25
STTTBA-3 1⍯ 5 75 35 ɀ Class II, Divisions 1 & 2 – NEC 502.4(A)(B)
ɀ Class III, Division 1 & 2 – NEC 503.3(A)(B)
STTTBA-4 11⁄4⍯ 5 50 40 ɀ UL Listed – UL Standard 514B
STTTBA-5 11⁄2⍯ 5 50 50 ɀ cUL Listed – Certified by UL to CSA Standard C22.2 No. 18
STTTBA-6 2⍯ 5 25 75 ɀ NEMA: FB-1
ɀ Suitable for wet locations Weight
NON-HAZARDOUS DRAIN PLUG Trade Unit Standard Lbs. Per
STAINLESS STEEL Cat. # Size Quantity Package 100
UL File No. E23223 1⁄2⍯
MHUB1 25 100 18
MHUB2 3⁄4⍯ 25 100 25
SSTC-1 1⁄2⍯ 25 25 13 MHUB3 1⍯ 5 50 50
SSTC-1CD 1⁄2⍯ 25 25 13
MHUB4 11⁄4⍯ 5 25 25
Note: SSTC-1 is for knockouts and is supplied with a locknut and straight threads. MHUB5 11⁄2⍯ 2 20 20
SSTC-1CD is for threaded openings and is supplied without locknut and NPT threads. MHUB6 2⍯ 1 10 10
Not gasketed to allow for water drainage
MHUB7 21⁄2⍯ 1 10 10
NON-HAZARDOUS DRAIN PLUG MHUB8 3⍯ 1 5 5
ALUMINUM MHUB9 31⁄2⍯ 1 5 5
UL File No. E23223 MHUB10 4⍯ 1 2 2
Weight MHUB11 5⍯ 1 1 1
Unit Standard Lbs. Per MHUB12 6⍯ 1 1 1
Cat. # Size Quantity Package 100
STAC-1ST 1⁄2⍯ 25 25 6 Conduit
STAC-1CD 1⁄2⍯ 25 25 6 Hub
Note: STAC-1ST is for knockouts and is supplied with a locknut and straight threads.
STAC-1CD is for threaded openings and is supplied without locknut and NPT threads. Dimension
Not gasketed to allow for water drainage
STIBOINFO((CRH:66008com:CP:269))
PDFINFO CH0 9 F - 3 5
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0270-4 Name: CP-270 DATE: JAN 19 2006 Time: 5:14:16 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
CP Myers®
Hubs
SCHEDULE OF DIMENSIONS
ɀ CP Myers Hubs
3⁄8 ST–03 1-3⁄32 1-1⁄8 21⁄32 1⁄8 .468 .493 3⁄8 NPT 3⁄8 NPS 60° 3⁄32 15⁄16 43⁄64 11⁄16
PLAN VIEW SIDE VIEW
1⁄2 ST–1 1-11⁄32 1-7⁄16 13⁄16 3⁄16 .591 .622 1⁄2 NPT 1⁄2 NPS 60° 1⁄8 1-1⁄2 55⁄64 7⁄8
STIBOINFO((CRH:66008com:CP:270))
PDFINFO CH0 9 F - 3 6
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0271-5 Name: CP-271 DATE: JAN 19 2006 Time: 5:14:16 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
ɀ CP Hangers
Cooper Crouse-Hinds TPSFH & TPRFH flexible fixture hangers are
used in commercial or light industrial applications where HID high bay
and low bay lighting fixtures are used. Specific applications include
storage facilities, shipping warehouses, retail and DIY facilities.
Fixture
Features & Benefits:
ɀ Suitable for use with 1⁄2⍯ or 3⁄4⍯ fixture conduit stems these hangers
allow the conduit stem of the fixture (luminaire) to swing in any
direction. Maximum swing angle is 26° from vertical max slope angles
221⁄2°
ɀ Available in two styles; one for attachment to round or octagonal
steel boxes, the other for attachment to 4⍯ square steel boxes.
ɀ Both styles are quickly and easily attached by two screws.
ɀ Hangers are drilled and tapped for use with 3⁄4⍯ conduit stem as
standard and come supplied with a 3⁄4⍯-1⁄2⍯ reducer for 1⁄2⍯ conduit stem
applications.
Sway Adapters
The Sway Adapter installs quickly and easily to pendant mounted
fixtures and compensates for shocks and motion due to movements,
vibration, earthquakes or other sources by allowing for lateral
movement up to 45 degrees. The Sway Adapter can be used
independently or in conjunction with the Swiv-L-Drop hanger. The
Sway Adapter is also finished in an aesthetically pleasing white
painted finish and is designed for use with 1⁄2⍯ conduit stems and has
3⁄8⍯ male threads.
STIBOINFO((CRH:66008com:CP:271))
PDFINFO CH0 9 F - 2 6
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0272-14 Name: CP-272 DATE: JAN 19 2006 Time: 5:14:18 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
Features:
Fittings
STIBOINFO((CRH:66008com:CP:272))
PDFINFO CH0 0 9 F - 1
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0273-8 Name: CP-273 DATE: JAN 19 2006 Time: 5:14:19 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
ɀ CP Fittings
SET SCREW TYPE FITTINGS
Couplings
UL File No. E-22132 Weight Features: Set Screw Type
Unit Standard Lbs. Per ɀ Pre-set & Staked Robertson Head Screws
ɀ Male Hub Threads - NPSM
Thinwall
Cat. # Size Quantity Package 100
660S 1⁄2⍯ 50 250 12 ɀ Steel Locknuts
661S 3⁄4⍯ 25 125 18 ɀ Heavy Steel Walls
662 1⍯ 25 100 27 ɀ Standard Material: Steel
ɀ Standard Finish: Zinc Plated
663 11⁄4⍯ 10 50 46 Concrete Tight
664 11⁄2⍯ 10 50 63 Straight Connectors – Insulated
665 2⍯ 5 25 92 UL File No. E-22132
666 21⁄2⍯ 2 10 250 Weight
667 3⍯ 1 5 410 Unit Standard Lbs. Per
668 31⁄2⍯ 1 5 390 Cat. # Size Quantity Package 100
669 4⍯ 1 5 485 1450 1⁄2⍯ 50 250 9
1451 3⁄4⍯ 25 100 14
SET SCREW TYPE FITTINGS 1452 1⍯ 20 100 23
New Space-Saver EMT Connector - Set Screw 1453* 11⁄4⍯ 10 50 46
UL File No. E-22132 1454* 11⁄2⍯ 10 50 50
Features: 1455* 2⍯ 5 25 78
ɀ Used to join EMT conduit to a box or 1456*+ 21⁄2⍯ 2 10 130
enclosure 1457*+ 3⍯ 1 5 140
ɀ Designed with the male threads on the 1458*+ 31⁄2⍯ 1 5 180
locknut, the Space-Saver takes up virtually no 1459*+ 4⍯ 1 5 225
room inside the box, and the smooth pulling surface eliminates the * Two Tightening Screws
need for a bushing or insulated throat Straight Connectors – Non-Insulated
ɀ Angled teeth on locknut bite into enclosure, preventing loosening UL File No. E-22132 Weight
from vibration Unit Standard Lbs. Per
ɀ Knurled wrenching surface for easy tightening Cat. # Size Quantity Package 100
ɀ Tri-head set screw may be installed using a slotted, Philips or 450S 1⁄2⍯ 50 250 9
Robertson head screwdriver 451 3⁄4⍯ 25 100 15
ɀ Zinc electroplated for corrosion resistance 452 1⍯ 20 100 23
ɀ Concrete tight when taped
453* 11⁄4⍯ 10 50 46
Certifications and Compliances: 454* 11⁄2⍯ 10 50 50
ɀ UL Listed 455* 2⍯ 5 25 77
ɀ cUL Listed Weight
Unit Standard Lbs. Per 456*+ 21⁄2⍯ 2 10 130
Cat. # Size Quantity Package 100 457*+ 3⍯ 1 5 140
458*+ 31⁄2⍯ 1 5 180
SSBC50 1⁄2⍯ 50 250 8 459*+ 4⍯ 1 5 225
SSBC75 3⁄4⍯ 25 100 12
SSBC100 1⍯ 25 100 12 * Two Tightening Screws
Couplings
COMBINATION COUPLINGS – STEEL UL File No. E-22132 Weight
Unit Standard Lbs. Per
Concrete Tight
Cat. # Size Quantity Package 100
EMT (Compression) to Rigid (Threaded) Compression Type NPT
460 1⁄2⍯ 50 250 9
Female Hubs
UL File No. E-19189 461 3⁄4⍯ 25 125 16
Weight
Unit Standard Lbs. Per 462 1⍯ 20 100 23
Cat. # Size Quantity Package 100 463* 11⁄4⍯ 10 50 42
690S 1⁄2⍯ 25 250 9 464* 11⁄2⍯ 10 50 50
691 3⁄4⍯ 20 200 13 465* 2⍯ 5 25 77
692 1⍯ 10 100 19 466*+ 21⁄2⍯ 2 10 130
467*+ 3⍯ 1 5 140
468*+ 31⁄2⍯ 1 5 240
469*+ 4⍯ 1 1 250
†Four Tightening Screws
UL and cUL Listed for EMT, IMC and Rigid Conduit
STIBOINFO((CRH:66008com:CP:273))
PDFINFO CH0 0 9 F - 2
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0274-13 Name: CP-274 DATE: JAN 19 2006 Time: 5:14:20 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
STIBOINFO((CRH:66008com:CP:274))
PDFINFO CH0 0 9 F - 2
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0275-10 Name: CP-275 DATE: JAN 19 2006 Time: 5:14:22 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
ɀ CP Fittings
EMT (Set Screw) to Flexible Steel (Clamp)
UL File No. E-19189 Weight
Application:
Unit Standard Lbs. Per ɀ Provides space between ɀ Standard material: Malleable Iron
conduit and mounting surface ɀ Standard finish: Zinc plated
Thinwall
Cat. # Size Quantity Package 100
UL File No. E-184283
780DC 1⁄2⍯–3⁄8⍯ 50 500 8 Weight
Unit Standard Lbs. Per
Cat. # Size Quantity Package 100
CB1 1⁄2⍯ 25 250 8
CB2 3⁄4⍯ 25 250 10
90 DEGREE PULLING ELBOWS – DIE CAST ZINC CB3 1⍯ 25 100 12
CB4 11⁄4⍯ 25 100 21
Features: CB5 11⁄2⍯ 25 100 42
ɀ Supplied threaded and with set screw for use with EMT or rigid CB6 2⍯ 10 50 40
conduit CB7 21⁄2⍯ 10 50 49
ɀ Removable cover facilitates wire pulling CB8 3⍯ 10 50 62
CB9 31⁄2⍯ 10 10 91
EMT To Box (also threaded for rigid to box)
UL File No. E-22132 Weight CB10 4⍯ 10 10 110
Unit Standard Lbs. Per CB11 5⍯ 5 5 135
Cat. # Size Quantity Package 100 CB12 6⍯ 5 5 225
810DC 1⁄2⍯ 10 100 31 CLAMPS ‘‘SNAP-ON’’ – STEEL
811DC 3⁄4⍯ 5 50 31
Application:
ɀ To support EMT conduit to mounting surface
EMT To EMT (also threaded for rigid conduit) Heavy Gauge
UL File No. E-22132 Weight UL File No. E-184283
Unit Standard Lbs. Per Weight
Cat. # Size Quantity Package 100 Unit Standard Lbs. Per
820DC 1⁄2⍯ 10 100 28 Cat. # Size Quantity Package 100
821DC 3⁄4⍯ 5 50 35 200 1⁄2⍯ 100 500 5
822DC 1⍯ 5 25 64 201 3⁄4⍯ 100 500 6
823DC 11⁄4⍯ 2 20 66 202 1⍯ 100 500 6
203 11⁄4⍯ 50 250 13
STRAPS – STEEL GALVANIZED 204 11⁄2⍯ 25 100 17
Two Hole 205 2⍯ 25 25 20
UL File No. E-184283
206* 21⁄2⍯ 25 25 64
Weight 207* 3⍯ 25 25 71
Unit Standard Lbs. Per 208* 31⁄2⍯ 10 10 120
Cat. # Size Quantity Package 100 209* 4⍯ 10 10 130
497-1 1⁄2⍯ 250 250 2 *Not UL LIsted
497-2 3⁄4⍯ 150 150 3
497-3 1⍯ 100 100 5 NAILING STRAPS – CAST STEEL
497-4 11⁄4⍯ 50 50 8 Support EMT, IMC and rigid conduit to mounting surface
497-5 11⁄2⍯ 50 50 13 ɀ Standard material: Cast Steel
497-6 2⍯ 25 25 14 ɀ Standard finish: Zinc Plated
496-9 21⁄2⍯ 25 25 19
496-10 3⍯ 25 25 23 Weight
496-11 31⁄2⍯ 25 25 93 Conduit Sizes Unit Standard Lbs. Per
496-12 4⍯ 10 10 108 Cat. # EMT Rigid Quantity Package 100
NS-1 1⁄2⍯ 3⁄8⍯ 100 1000 2
CLAMPS – MALLEABLE IRON NS-2 3⁄4⍯ 1⁄2⍯ 100 1000 2
UL File No. E-184283 NS-3 1⍯ 3⁄4⍯ 100 1000 3
Weight
Unit Standard Lbs. Per Nailing Straps Dimensions – Inches
Cat. # Size Quantity Package 100 Cat. # A B C D
516 21⁄2⍯ 5 25 104 NS-1 3⁄16 1 17⁄8 3⁄4
517 3⍯ 2 10 120 NS-2 3⁄4 11⁄4 2 15⁄16
518 31⁄2⍯ 2 10 150 NS-3 3⁄16 11⁄2 21⁄2 11⁄8
519 4⍯ 2 10 220
STIBOINFO((CRH:66008com:CP:275))
PDFINFO CH0 0 9 F - 3
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0276-3 Name: CP-276 DATE: JAN 19 2006 Time: 5:14:23 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
CP Rigid/Intermediate Grade
Conduit Fittings ɀ Type CPR Compression Fittings
Concrete Tight ɀ Set Screw Type Fittings
Features/Benefits:
ɀ UL Listed for use with IMC as well as metallic rigid conduit.
ɀ CP Rigid
STIBOINFO((CRH:66008com:CP:276))
PDFINFO CH0 0 9 F - 4
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0277-5 Name: CP-277 DATE: JAN 19 2006 Time: 5:14:24 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
Rigid/Intermediate Grade CP
Conduit Fittings ɀ Set Screw Type Fittings
Concrete Tight
ɀ CP Intermediate
Couplings
UL File No. E-19189 Weight
Unit Standard Lbs. Per
Rigid
Cat. # Size Quantity Package 100
160 1⁄2⍯ 25 100 27
161 3⁄4⍯ 20 100 40
162 1⍯ 5 50 52
163 11⁄4⍯ 10 50 70
164 11⁄2⍯ 5 25 104
165* 2⍯ 2 10 160
466* 21⁄2⍯ 2 10 300
467* 3⍯ 1 5 400
468* 31⁄2⍯ 1 1 500
469* 4⍯ 1 1 600
ɀ170C*† 5⍯ 1 1 1500
ɀ171C*† 6⍯ 1 1 1800
* Four Tightening Screws
ɀ Not CSA Certified
†Malleable Iron
STIBOINFO((CRH:66008com:CP:277))
PDFINFO CH0 0 9 F - 5
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0278-8 Name: CP-278 DATE: JAN 19 2006 Time: 5:14:25 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
STIBOINFO((CRH:66008com:CP:278))
PDFINFO CH0 0 9 F - 6
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0279-5 Name: CP-279 DATE: JAN 19 2006 Time: 5:14:26 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
ɀ CP Intermediate
(Concrete Tight) ɀ Standard material: Steel 3⁄8⍯ – 2 ⍯ STEEL, 21⁄2⍯ – 6⍯ MALLEABLE IRON
EMT (Set Screw) To Rigid ɀ Standard finish: Zinc Plated UL File No. E-19189 Weight
(Set Screw) Weight Unit Standard Lbs. Per
Rigid
UL File No. E-19189 Unit Standard Lbs. Per Cat. # Size Quantity Package 100
Cat. # Size Quantity Package 100 10 3⁄8⍯ 100 2500 1
420 1⁄2⍯–1⁄2⍯ 25 100 17 11 1⁄2⍯ 100 2500 1
421 3⁄4⍯–3⁄4† 20 100 25 12 3⁄4⍯ 100 1000 2
422 1⍯–1⍯ 10 50 37 13 1⍯ 50 500 5
14 11⁄4⍯ 100 500 7
COMBINATION COUPLINGS – MALLEABLE IRON 15 11⁄2⍯ 50 250 8
Flexible Steel (Squeeze Type) To Rigid (Threaded)
Weight 16 2⍯ 50 250 13
Unit Standard Lbs. Per 17 21⁄2⍯ 20 100 26
Cat. # Size Quantity Package 100 18 3⍯ 10 50 42
65 1⁄2⍯–1⁄2⍯ 10 100 17 19 31⁄2⍯ 10 50 54
66 3⁄4⍯–3⁄4⍯ 10 100 22 20 4⍯ 5 25 68
67 1⍯–1⍯ 5 25 31 22 5⍯ 2 2 110
68 11⁄4⍯–11⁄4⍯ 5 25 31 23 6⍯ 1 1 154
INSULATED THROAT BUSHINGS
COMBINATION COUPLINGS – DIE CAST ZINC
Malleable Iron Threaded 105°C Rated Plastic Throat Liner
(Concrete Tight) UL File No. E-19189 Weight
EMT (Set Screw) To Rigid (Set Screw) Unit Standard Lbs. Per
UL File No. E-19189 Weight
Cat. # Size Quantity Package 100
Unit Standard Lbs. Per
1031 1⁄2⍯ 100 1000 3
Cat. # Size Quantity Package 100
1032 3⁄4⍯ 100 500 4
2420 1⁄2⍯–1⁄2⍯ 50 500 8
3⁄4⍯–3⁄4⍯
1033 1⍯ 50 250 7
2421 25 250 12
1034 11⁄4⍯ 50 250 15
1035 11⁄2⍯ 10 100 19
1036 2⍯ 20 100 22
1037 21⁄2⍯ 10 50 44
FITTING LOCKNUTS
1038 3⍯ 10 50 54
STEEL 1039 31⁄2⍯ 5 25 72
Weight
Unit Standard Lbs. Per 1040 4⍯ 5 25 95
Cat. # Size Quantity Package 100 ɀ1041 5⍯ 1 1 100
1⁄2⍯
ɀ1042 6⍯ 1 1 127
11X 500 2500 1
12X 3⁄4⍯ 100 1000 2 Set Screw Type – Threadless 105°C Rated Plastic Throat Liner
UL File No. E-19189 Weight
13X 1⍯ 50 500 5
Unit Standard Lbs. Per
14X 11⁄4⍯ 100 500 7
Cat. # Size Quantity Package 100
15X 11⁄2⍯ 50 250 8
S1031 1⁄2⍯ 100 1000 3
16X 2⍯ 50 250 13
S1032 3⁄4⍯ 100 500 4
17X 21⁄2⍯ 25 100 14
S1033 1⍯ 50 250 7
18X 3⍯ 20 100 19
19X 31⁄2⍯ 10 50 24 S1034 11⁄4⍯ 50 250 15
20X 4⍯ 10 50 29 S1035 11⁄2⍯ 10 100 19
S1036 2⍯ 20 100 22
GROUNDING LOCKNUTS
S1037 21⁄2⍯ 10 50 44
STEEL S1038 3⍯ 10 50 54
For use with bushing to bond 1⁄2⍯ to 4⍯ rigid conduit to boxes, cabinets S1039 31⁄2⍯ 5 25 72
or other enclosures, only where a locknut is exposed.
S1040 4⍯ 5 25 95
UL File No. E-6225 Weight S1041 5⍯ 1 1 100
Unit Standard Lbs. Per S1042 6⍯ 1 1 127
Cat. # Size Quantity Package 100
1⁄2⍯
ɀ Not UL Listed
GL-11 100 1000 4
GL-12 3⁄4⍯ 50 500 4
GL-13 1⍯ 50 500 6
GL-14 11⁄4⍯ 50 250 8
GL-15 11⁄2⍯ 50 250 10
GL-16 2⍯ 25 100 20
GL-17 21⁄2⍯ 20 100 25
GL-18 3⍯ 10 50 42
GL-19 31⁄2⍯ 10 50 60
GL-20 4⍯ 5 25 80
STIBOINFO((CRH:66008com:CP:279))
PDFINFO CH0 0 9 F - 7
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0280-2 Name: CP-280 DATE: JAN 19 2006 Time: 5:14:27 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
INSULATED THROAT GROUNDING BUSHINGS Copper Lug – For Copper Grounding Conductors – Threadless –
Set Screw Type 105°C Rated Plastic Throat Liner
Intermediate
STIBOINFO((CRH:66008com:CP:280))
PDFINFO CH0 0 9 F - 8
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0281-7 Name: CP-281 DATE: JAN 19 2006 Time: 5:14:28 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
ɀ CP Intermediate
UL File No. E-19189 ɀ Materials: Plastic
Features:
ɀ Resilient plastic liner, resists corrosion, chemicals and temperature
extremes.
Rigid
ɀ Insuliner - ULTEM1000 rated at 150°C
Weight ɀ 1 Set screw provided with each fitting locks bushing in any desired
Rated 105°C Rated 150°C Trade Unit Standard Lbs. Per position
Cat. # Cat. # Size Quantity Package 100 ɀ External stainless steel hardware as standard
931 H–931 1⁄2⍯ 50 500 1 Standard Finish:
932 H–932 3⁄4⍯ 50 500 1 ɀ Body - Zinc Plated
933 H–933 1⍯ 50 200 2 IRON – 150°C RATED
934 H–934 11⁄4⍯ 50 200 3 Copper Lug – For Copper Grounding Conductors – Threaded
935 H–935 11⁄2⍯ 25 100 3 UL File No. E-6225
STIBOINFO((CRH:66008com:CP:281))
PDFINFO CH0 0 9 F - 9
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0282-2 Name: CP-282 DATE: JAN 19 2006 Time: 5:14:29 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
CP Rigid/Intermediate Grade
Conduit Fittings ɀ Insulated Throat Grounding Bushings
ɀ Three Piece Conduit Couplings
ɀ Conduit Bushed Nipples
Features: Application:
ɀ Resilient plastic liner resists corossion, chemicals and temperature Used to join two lengths of threaded conduit. Couples conduit when
ɀ CP Rigid
STIBOINFO((CRH:66008com:CP:282))
PDFINFO CH0 9 F - 1 0
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0283-4 Name: CP-283 DATE: JAN 19 2006 Time: 5:14:55 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
CONDUIT BUSHED NIPPLES – DIE CAST ZINC Female To Female; Combination Rigid and EMT
ɀ CP Intermediate
UL File No. E-19189 Weight
Non-Insulated Unit Standard Lbs. Per
UL File No. E-19189 Weight
Cat. # Size Quantity Package 100
Unit Standard Lbs. Per
820DC 1⁄2⍯ 10 100 28
Rigid
Cat. # Size Quantity Package 100
821DC 3⁄4⍯ 5 50 35
50D 1⁄2⍯ 100 1000 4
3⁄4⍯
822DC 1⍯ 5 25 64
51D 50 500 5
823DC 11⁄4⍯ 2 20 66
52D 1⍯ 25 250 10
53D 11⁄4⍯ 25 100 11
54D 11⁄2⍯ 25 100 20
55D 2⍯ 10 40 30
56D 21⁄2⍯ 10 40 40 OFFSET CONDUIT NIPPLES – MALLEABLE IRON
57D 3⍯ 10 40 49
58D 31⁄2⍯ 10 40 68 Features:
59D 4⍯ 5 20 70 ɀ Threaded NPSM for rigid conduit and IMC
ɀ Standard Finish: Zinc Plated
90 DEGREE PULL ELBOWS – MALLEABLE IRON ɀ USE: To offset the axis of raceways 3⁄4 of an inch
Weight
Features: Unit Standard Lbs. Per
ɀ Raintight
Cat. # Size Quantity Package 100
ɀ Furnished with Neoprene gasketed steel cover
300 1⁄2⍯ 25 100 24
ɀ Furnished with Steel lock nut
301 3⁄4⍯ 25 100 34
ɀ Furnished with Stamped Steel cover
ɀ Threaded for rigid conduit and IMC 302 1⍯ 10 50 49
ɀ For outdoor use 303 11⁄4⍯ 10 50 54
ɀ Standard Finish: Zinc plated OFFSET CONDUIT NIPPLES – DIE CAST ZINC
(Gasketed – Liquidtight) UL File No. E-19189 Weight
Male To Female
Unit Standard Lbs. Per
UL File No. E-19189
Weight Cat. # Size Quantity Package 100
300DC 1⁄2⍯ 10 100 9
Unit Standard Lbs. Per
301DC 3⁄4⍯ 10 100 15
Cat. # Size Quantity Package 100
810 1⁄2⍯ 20 100 34 302DC 1⍯ 10 100 21
811 3⁄4⍯ 10 50 56 303DC 11⁄4⍯ 5 50 33
812 1⍯ 5 25 88 304 11⁄2⍯ 5 50 40
813 11⁄4⍯ 2 10 92 305 2⍯ 2 20 65
814 11⁄2⍯ 2 10 200
815 2⍯ 1 5 344
KNOCKOUT SNAP-IN BLANKS – STEEL
Female To Female Weight
UL File No. E-19189 Weight
Unit Standard Lbs. Per
Unit Standard Lbs. Per
Cat. # Size Quantity Package 100
Cat. # Size Quantity Package 100
335 1⁄2⍯ 100 1000 2
820 1⁄2⍯ 20 100 36
336 3⁄4⍯ 100 1000 2
821 3⁄4⍯ 10 50 49
337 1⍯ 50 500 2
822 1⍯ 5 25 94
338 11⁄4⍯ 50 250 3
823 11⁄4⍯ 2 10 140
339 11⁄2⍯ 25 250 5
824 11⁄2⍯ 2 10 200
340 2⍯ 20 200 7
825 2⍯ 1 5 344
PUSH PLUGS – PLASTIC*
Weight
90 DEGREE PULL ELBOWS – DIE CAST ZINC
Unit Standard Lbs. Per
(Gasketed – Liquidtight) Cat. # Size Quantity Package 100
Male To Female; Combination Rigid and EMT PPC-50 1⁄2⍯ 100 1000 1
UL File No. E-19189 Weight
PPC-75 3⁄4⍯ 100 1000 1
Unit Standard Lbs. Per
PPC-100 1⍯ 50 500 1
Cat. # Size Quantity Package 100
1⁄2⍯
PPC-125 11⁄4⍯ 50 200 1
810DC 10 100 31
3⁄4⍯
PPC-150 11⁄2⍯ 25 100 1
811DC 5 50 31
PPC-200 2⍯ 25 100 1
PPC-250 21⁄2⍯ — 100 2
PPC-300 3⍯ — 100 3
PPC-350 31⁄2⍯ — 50 6
PPC-400 4⍯ — 50 8
*Temperature Rating: 180° – 200°F
Tensile Strength: 600 – 2300 PSI
STIBOINFO((CRH:66008com:CP:283))
PDFINFO CH0 9 F - 1 1
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0284-5 Name: CP-284 DATE: JAN 19 2006 Time: 5:15:00 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
A penny under a bushing will seal the end of conduit during NS-1 3⁄16 1 17⁄8 3⁄4
STIBOINFO((CRH:66008com:CP:284))
PDFINFO CH0 9 F - 1 2
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0285-15 Name: CP-285 DATE: JAN 19 2006 Time: 5:15:01 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
ɀ CP Intermediate
UL File No. E-184283
(Heavy Gauge)
Application:
Right Angle - to attach the conduit run at a 90° angle to a beam or
Application: structural member
Rigid
ɀ To support rigid conduit and IMC to mounting service Right Angle Type – Electrogalvanized – Iron
Weight Load Weight
Unit Standard Lbs. Per Trade Rating Standard Lbs. Per
Cat. # Size Quantity Package 100 Cat. # Size Lbs Package 100
410* 1⁄2⍯ 100 500 5 RAC50HD 1⁄2⍯ 30 50 37
411* 3⁄4⍯ 100 500 6 RAC75HD 3⁄4⍯ 50 50 40
412* 1⍯ 50 250 11 RAC100HD 1⍯ 60 50 42
413* 11⁄4⍯ 50 250 13 RAC125HD 11⁄4⍯ 75 25 49
414 11⁄2⍯ 25 100 20 RAC150HD 11⁄2⍯ 80 25 54
415 2⍯ 25 25 22 RAC200HD 2⍯ 100 25 71
206 21⁄2⍯ 25 25 64 RAC250HD 21⁄2⍯ 125 10 95
207 3⍯ 25 25 71 RAC300HD 3⍯ 165 10 107
208 31⁄2⍯ 10 10 120 RAC350HD 31⁄2⍯ 200 10 120
209 4⍯ 10 10 130 RAC400HD 4⍯ 330 10 131
* CSA Certified
Application:
CLAMPS – STEEL Parallel Type - to attach the conduit run parallel to a beam or structural
(Light Gauge) member
Conduit Size of Weight Parallel Type – Electrogalvanized – Iron
Sizes Strap Unit Standard Lbs. Per Load Weight
Cat. # Rigid Inside Quantity Package 100 Trade Rating Standard Lbs. Per
1⁄4⍯
Cat. # Size Lbs Package 100
566 .540 500 500 2
3⁄8⍯ PARC50HD 1⁄2⍯ 30 50 50
567 .675 200 1000 2
PARC75HD 3⁄4⍯ 50 50 53
CABLE AND CONDUIT HANGERS – STEEL PARC100HD 1⍯ 60 50 60
With Bolts PARC125HD 11⁄4⍯ 75 25 70
Conduit Conduit Weight PARC150HD 11⁄2⍯ 80 25 82
Sizes Size Unit Standard Lbs. Per PARC200HD 2⍯ 100 25 132
Cat. # Rigid EMT Quantity Package 100
PARC250HD 21⁄2⍯ 125 25 192
0B 1⁄2⍯ 3⁄8⍯ & 1⁄2⍯ 100 100 6 PARC300HD 3⍯ 165 10 194
3⁄4⍯ 3⁄4⍯
1-B 100 100 6 PARC350HD 31⁄2⍯ 200 10 216
2-B 1⍯ 1⍯ 100 100 8 PARC400HD 4⍯ 330 10 232
21⁄2-B 11⁄4⍯ — 100 100 10
3-B 11⁄2⍯ 11⁄4⍯ 100 100 11 CONDUIT CLAMPS
4-B — 11⁄2⍯ 100 100 16
Applications:
5-B 2⍯ 2⍯ 50 50 23 Edge Type - to attach the conduit run at a 90° angle to a thin beam or
6-B 21⁄2⍯ 21⁄2⍯ 50 50 29 structural member.
7-B 3⍯ 3⍯ 25 25 31 Edge Type – Electrogalvanized – Iron
8-B 31⁄2⍯ 31⁄2⍯ 10 10 38 Weight
9-B 4⍯ 4 10 10 38 Trade Standard Lbs. Per
Cat. # Size Package 100
BEAM CLAMPS/INSULATOR SUPPORTS 1⁄2⍯
ETC50HD 50 63
– MALLEABLE IRON ETC75HD 3⁄4⍯ 50 69
UL File No. E-184283 ɀ Standard finish: Zinc Plated ETC100HD 1⍯ 50 82
Wt. ETC125HD 11⁄4⍯ 25 95
Cat. Base Jaw Max. Wt. Tapped Unit Std. Lbs./ ETC150HD 11⁄2⍯ 25 108
# Size Open Support Holes Qty. Pkg. 100 ETC200HD 2⍯ 25 121
528* 3⁄4⍯ 5⁄8⍯ 230 10 – 24 25 100 14 ETC250HD 21⁄2⍯ 25 153
529* 3⁄4⍯ 5⁄8⍯ 230 1⁄4⍯ – 20 25 100 13 ETC300HD 3⍯ 10 214
530 1⍯ 3⁄4⍯ 230 10 – 24 25 100 23
3⁄4⍯ 1⁄4⍯ – 20 25
Conduit Beam Clamp — J Type – Iron
531 1⍯ 230 100 24
UL File No. E-184283
532 11⁄2⍯ 3⁄4⍯ 290 5⁄16⍯ – 18 50 50 47
7⁄8⍯ 3⁄8⍯ – 16 25
Max Weight
533 2⍯ 330 25 81
Weight Unit Std. Lbs. Per
534 21⁄2⍯ 7⁄8⍯ 800 1⁄2⍯ – 13 25 25 155
* Not UL listed Cat. # Size Support Qty. Pkg. 100
JCC1 1⁄2⍯ 150 25 25 35
BEAM CLAMPS/INSULATOR SUPPORTS – STEEL 3⁄4⍯
Weight JCC2 150 25 25 43
Base Jaw Tapped Unit Std. Lbs. Per JCC34 1⍯ & 11⁄4⍯ 225 10 10 90
Cat. # Size Opening Holes Qty. Pkg. 100 JCC56 11⁄2⍯ & 2⍯ 300 5 5 190
529-S 3⁄4⍯ 5⁄8⍯ 1⁄4⍯ – 20 50 50 13 JCC78 21⁄2⍯ & 3⍯ 500 2 2 380
JCC910 31⁄2⍯ & 4⍯ 700 2 2 575
STIBOINFO((CRH:66008com:CP:285))
PDFINFO CH0 9 F - 1 3
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0286-10 Name: CP-286 DATE: JAN 19 2006 Time: 5:15:03 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
Cat. # Size Quantity Package 100 Cat. # Size Quantity Package 100
251 3⁄4⍯–1⁄2⍯ 50 50 4 PLG1M 1⁄2⍯ 50 50 6
252 1⍯–1⁄2⍯ 25 25 13 PLG2M 3⁄4⍯ 50 50 11
253 11⁄4⍯–1⁄2⍯ 10 10 30 PLG3M 1⍯ 25 25 22
254 11⁄2⍯–1⁄2⍯ 10 10 43 PLG4M 11⁄4⍯ 25 25 34
255 2⍯–1⁄2⍯ 5 5 83 PLG5M 11⁄2⍯ 10 10 48
260 1⍯–3⁄4⍯ 25 25 7 PLG6M 2⍯ 10 10 82
261 11⁄4⍯–3⁄4⍯ 10 10 23 PLG7M 21⁄2⍯ 2 2 150
262 11⁄2⍯–3⁄4⍯ 10 10 40 PLG8M 3⍯ 2 2 222
263 2⍯–3⁄4⍯ 5 5 79 PLG9M 31⁄2⍯ 1 1 340
268 11⁄4⍯–1⍯ 10 10 18 PLG10M 4⍯ 1 1 380
269 11⁄2⍯–1⍯ 10 10 27 Square Head Weight
270S 2⍯–1⍯ 5 5 66 Unit Standard Lbs. Per
275 11⁄2⍯–11⁄4⍯ 10 10 13 Cat. # Size Quantity Package 100
276 2⍯–11⁄4⍯ 5 5 24 PLG15M 1⁄2⍯ 50 50 12
281 2⍯–11⁄2⍯ 5 5 27 PLG25M 3⁄4⍯ 50 50 16
282 21⁄2⍯–1⍯ 10 10 120 PLG35M 1⍯ 25 25 25
283 21⁄2⍯–11⁄4⍯ 10 10 130 PLG45M 11⁄4⍯ 25 25 34
285 21⁄2⍯–2⍯ 10 10 150 PLG55M 11⁄2⍯ 10 10 48
288 3⍯–11⁄2⍯ 5 5 210 PLG65M 2⍯ 10 10 80
289 3⍯–2⍯ 2 2 160 PLG75M 21⁄2⍯ 1 1 116
290M 3⍯–21⁄2⍯ 5 5 120 PLG85M 3⍯ 1 1 185
291 31⁄2⍯–2⍯ 2 10 200 PLG95M 31⁄2⍯ 1 1 232
292 31⁄2⍯–21⁄2⍯ 2 10 225 PLG105M 4⍯ 1 1 310
293 31⁄2⍯–3⍯ 2 10 150
294 4⍯–2⍯ 2 10 270
295 4⍯–21⁄2⍯ 2 10 270
296 4⍯–3⍯ 2 10 260
297 4⍯–31⁄2⍯ 2 10 160
298 5⍯–4⍯ 1 1 385
299 6⍯–5⍯ 1 1 475
STIBOINFO((CRH:66008com:CP:286))
PDFINFO CH0 9 F - 1 4
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0287-18 Name: CP-287 DATE: JAN 19 2006 Time: 5:15:04 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
ɀ CP Intermediate
Electrogalvanized – Iron Weight Hub
Trade Thread Standard Lbs. Per Dimension
Cat. # Size Size Package 100
Rigid
UBM50HD 1⁄2⍯ 5⁄16⍯–18 200 12
UBM75HD 3⁄4⍯ 5⁄16⍯–18 200 14
UBM100HD 1⍯ 5⁄16⍯–18 100 17 Conduit
Cat. # Size a b c d x
UBM125HD 11⁄4⍯ 5⁄16⍯–18 50 19
UBM150HD 11⁄2⍯ 5⁄16⍯–18 50 21 HUB1 1⁄2 1 11⁄4 1 1⁄8 9⁄64
UBM200HD 2⍯ 3⁄8⍯–16 50 28 HUB2 3⁄4 11⁄8 19⁄16 13⁄8 5⁄32 1⁄4
UBM250HD 2 ⁄2⍯
1 3⁄8⍯–16 25 37 HUB3 1 13⁄8 17⁄8 15⁄8 3⁄16 9⁄32
UBM350HD 31⁄2⍯ 3⁄8⍯–16 20 46 HUB5 11⁄2 15⁄8 21⁄2 23⁄8 1⁄4 7⁄16
STIBOINFO((CRH:66008com:CP:287))
PDFINFO CH0 9 F - 1 5
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0288-3 Name: CP-288 DATE: JAN 19 2006 Time: 5:15:05 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
STIBOINFO((CRH:66008com:CP:288))
PDFINFO CH0 9 F - 1 6
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0289-5 Name: CP-289 DATE: JAN 19 2006 Time: 5:15:07 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
ɀ CP Outlet Bodies
Internal Weight
Type C † Trade Volume in Unit Std. Lbs. Per
Internal Weight
Cat. # Size Cubic Inches Qty. Pkg. 100
Trade Volume in Unit Std. Lbs. Per
Cat. # Size Cubic Inches Qty. Pkg. 100 LB15 1⁄2⍯ 4.25 10 100 27
1⁄2⍯
LB25 3⁄4⍯ 7.2 10 50 40
C15 4.25 10 100 27
3⁄4⍯
LB35 1⍯ 10.8 5 25 56
C25 7.0 10 50 40
C35 1⍯ 10.8 5 25 64 LB45 11⁄4⍯ 28.8 2 10 132
LB55 11⁄2⍯ 32.3 2 10 175
C45 11⁄4⍯ 32.3 2 10 165
LB65 2⍯ 66.5 1 5 240
C55 11⁄2⍯ 32.3 2 10 150
C65 2⍯ 64.0 1 5 270 LB75 21⁄2⍯ Over 100 1 1 450
LB85 3⍯ Over 100 1 1 460
C75 21⁄2⍯ Over 100 1 1 500
LB95 31⁄2⍯ Over 100 1 1 800
C85 3⍯ Over 100 1 1 600 LB105 4⍯ Over 100 1 1 900
C95* 31⁄2⍯ Over 100 1 1 900
C105* 4⍯ Over 100 1 1 1000 Covers, Aluminum
Weight
刁Not UL Listed
Conduit Unit Standard Lbs. Per
Cat. # Size Quantity Package 100
Type LL †
150 1⁄2⍯ 50 250 5
Internal Weight
250 3⁄4⍯ 50 250 6
Trade Volume in Unit Std. Lbs. Per
Cat. # Size Cubic Inches Qty. Pkg. 100 350 1⍯ 50 250 20
LL15 1⁄2⍯ 4.25 10 100 30 450 11⁄4⍯–11⁄2⍯ 50 50 25
LL25 3⁄4⍯ 7.0 10 50 48 650 2⍯ 25 25 25
LL35 1⍯ 10.8 5 25 64 850D 21⁄2⍯–3⍯ 10 10 78
950D 31⁄2⍯–4⍯ 5 5 140
LL45 11⁄4⍯ 32.3 2 10 140
LL55 11⁄2⍯ 32.3 2 10 160 Gaskets, Neoprene
LL65 2⍯ 63.0 1 5 270 Weight
Conduit Unit Standard Lbs. Per
LL75 21⁄2⍯ Over 100 1 1 500
Cat. # Size Quantity Package 100
LL85 3⍯ Over 100 1 1 600
1⁄2⍯
LL95 31⁄2⍯ Over 100 1 1 900 GASK015N 100 100 2
GASK025N 3⁄4⍯ 100 100 2
LL105 4⍯ Over 100 1 1 1000
GASK035N 1⍯ 50 50 3
Type LR †
Internal Weight GASK045N 11⁄4⍯–11⁄2⍯ 50 50 6
Trade Volume in Unit Std. Lbs. Per GASK065N 2⍯ 25 25 10
Cat. # Size Cubic Inches Qty. Pkg. 100 GASK085N 21⁄2⍯–3⍯ 10 10 20
GASK095N 31⁄2⍯–4⍯ 10 10 30
LR15 1⁄2⍯ 4.25 10 100 26
LR25 3⁄4⍯ 7.0 10 50 48
LR35 1⍯ 10.8 5 25 64
LR45 11⁄4⍯ 32.3 2 10 140
LR55 11⁄2⍯ 32.3 2 10 160
LR65 2⍯ 63.0 1 5 260
LR75 21⁄2⍯ Over 100 1 1 500
LR85 3⍯ Over 100 1 1 600
LR95 31⁄2⍯ Over 100 1 1 900
LR105 4⍯ Over 100 1 1 1000
Type T †
Internal Weight
Trade Volume in Unit Std. Lbs. Per
Cat. # Size Cubic Inches Qty. Pkg. 100
T15 1⁄2⍯ 4.25 10 100 32
T25 3⁄4⍯ 7.0 10 50 46
T35 1⍯ 10.8 5 25 70
T45 11⁄4⍯ 32.3 2 10 175
T55 11⁄2⍯ 32.3 2 10 185
T65 2⍯ 64.0 1 2 300
T75 21⁄2⍯ Over 100 1 1 550
T85 3⍯ Over 100 1 1 650
T95* 31⁄2⍯ Over 100 1 1 950
T105* 4⍯ Over 100 1 1 1050
刁Not UL Listed
Options:
†SnapPack TM pre-packaged body, cover and neoprene gasket add suffix CGN ie. LB25-CGN
STIBOINFO((CRH:66008com:CP:289))
PDFINFO CH0 9 F - 1 7
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0290-3 Name: CP-290 DATE: JAN 19 2006 Time: 5:15:14 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
CP Conduit Outlet Bodies ɀ Rigid and combination Rigid or IMC and EMT
Conduit Outlet Bodies
Series 5 ɀ Die Cast Aluminum
Dimensions
Size A B C D E F
1⁄2⍯ 111⁄32⍯ 157⁄64⍯ 1⁄2⍯ 211⁄64⍯ 413⁄32⍯ 15⁄32⍯
3⁄4⍯ 135⁄64⍯ 449⁄64⍯ 3⁄4⍯ 27⁄16⍯ 51⁄8⍯ 13⁄8⍯
1⍯ 13⁄4⍯ 53⁄8⍯ 1⍯ 23⁄4⍯ 515⁄16⍯ 123⁄32⍯
11⁄4⍯ 235⁄64⍯ 715⁄64⍯ 11⁄4⍯ 335⁄64⍯ 77⁄8⍯ 215⁄64⍯
11⁄2⍯ 219⁄32⍯ 717⁄64⍯ 11⁄2⍯ 323⁄32⍯ 77⁄8⍯ 23⁄8⍯
2⍯ 313⁄64⍯ 933⁄64⍯ 2⍯ 41⁄4⍯ 1015⁄64⍯ 229⁄32⍯
21⁄2⍯ 41⁄2⍯ 123⁄16⍯ 21⁄2⍯ 55⁄32⍯ 123⁄4⍯ 313⁄32⍯
3⍯ 415⁄32⍯ 1217⁄64⍯ 3⍯ 521⁄32⍯ 1243⁄64⍯ 41⁄64⍯
31⁄2⍯ 539⁄64⍯ 51⁄32⍯ 31⁄2⍯ 661⁄64⍯ 1535⁄64⍯ 55⁄32⍯
4⍯ 539⁄64⍯ 151⁄32⍯ 4⍯ 661⁄64⍯ 1535⁄64⍯ 55⁄32⍯
Type C Dimensions – Threaded & Set Screw
Conduit
Size A B C D E F
1⁄2⍯ 15⁄16⍯ 327⁄32⍯ 1⁄2⍯ 11⁄2⍯ 427⁄32⍯ 11⁄8⍯
3⁄4⍯ 117⁄32⍯ 419⁄32⍯ 3⁄4⍯ 15⁄8⍯ 541⁄64⍯ 15⁄16⍯
1⍯ 13⁄4⍯ 511⁄32⍯ 1⍯ 129⁄32⍯ 61⁄2⍯ 11⁄2⍯
11⁄4⍯ 217⁄32⍯ 71⁄4⍯ 11⁄4⍯ 23⁄4⍯ 81⁄2⍯ 21⁄4⍯
11⁄2⍯ 217⁄32⍯ 71⁄4⍯ 11⁄2⍯ 23⁄4⍯ 81⁄2⍯ 21⁄4⍯
2⍯ 27⁄32⍯ 97⁄16⍯ 2⍯ 313⁄32⍯ 103⁄4⍯ 23⁄4⍯
21⁄2⍯ 41⁄2⍯ 121⁄4⍯ 21⁄2⍯ 41⁄2⍯ 13⍯ 41⁄2⍯
3⍯ 41⁄2⍯ 121⁄4⍯ 3⍯ 41⁄2⍯ 13⍯ 41⁄2⍯
31⁄2⍯ 51⁄2⍯ 15⍯ 31⁄2⍯ 59⁄16⍯ 165⁄16⍯ 51⁄2⍯
4⍯ 51⁄2⍯ 15⍯ 4⍯ 59⁄16⍯ 165⁄16⍯ 51⁄2⍯
Type LL Dimensions – Threaded & Set Screw
Conduit
Size A B C D E F
1⁄2⍯ 13⁄32⍯ 37⁄8⍯ 2⍯ 1⁄2⍯ 49⁄32⍯ 113⁄32⍯
3⁄4⍯ 11⁄4⍯ 421⁄32⍯ 3⁄4⍯ 211⁄32⍯ 51⁄8⍯ 113⁄32⍯
1⍯ 11⁄2⍯ 523⁄64⍯ 1⍯ 21⁄2⍯ 599⁄64⍯ 17⁄8⍯
11⁄4⍯ 21⁄4⍯ 717⁄64⍯ 11⁄4⍯ 313⁄32⍯ 755⁄64⍯ 27⁄8⍯
11⁄2⍯ 21⁄4⍯ 717⁄64⍯ 11⁄2⍯ 313⁄32⍯ 755⁄64⍯ 27⁄8⍯
2⍯ 23⁄4⍯ 915⁄32⍯ 2⍯ 327⁄32⍯ 1013⁄64⍯ 327⁄64⍯
21⁄2⍯ 45⁄8⍯ 121⁄4⍯ 21⁄2⍯ 53⁄4⍯ 13⍯ 41⁄2⍯
3⍯ 45⁄8⍯ 121⁄4⍯ 3⍯ 53⁄4⍯ 13⍯ 41⁄2⍯
31⁄2⍯ 57⁄16⍯ 15⍯ 31⁄2⍯ 61⁄8⍯ 165⁄16⍯ 59⁄16⍯
4⍯ 57⁄16⍯ 15⍯ 4⍯ 61⁄8⍯ 165⁄16⍯ 59⁄16⍯
Type LR Dimensions – Threaded & Set Screw
Conduit
Size A B C D E F
1⁄2⍯ 17⁄64⍯ 37⁄8⍯ 2⍯ 1⁄2⍯ 49⁄32⍯ 113⁄32⍯
3⁄4⍯ 11⁄4⍯ 421⁄32⍯ 3⁄4⍯ 211⁄32⍯ 51⁄8⍯ 141⁄64⍯
1⍯ 1 ⁄2⍯
1 5 ⁄64⍯
23 1⍯ 21⁄2⍯ 559⁄64⍯ 17⁄8⍯
11⁄4⍯ 21⁄4⍯ 717⁄64⍯ 11⁄4⍯ 313⁄32⍯ 755⁄64⍯ 27⁄8⍯
11⁄2⍯ 21⁄4⍯ 717⁄64⍯ 11⁄2⍯ 313⁄32⍯ 755⁄64⍯ 27⁄8⍯
2⍯ 23⁄4⍯ 915⁄32⍯ 2⍯ 327⁄32⍯ 1013⁄64⍯ 327⁄64⍯
21⁄2⍯ 47⁄16⍯ 121⁄4⍯ 21⁄2⍯ 513⁄16⍯ 121⁄4⍯ 41⁄2⍯
3⍯ 45⁄8⍯ 121⁄4⍯ 3⍯ 513⁄16⍯ 121⁄4⍯ 41⁄2⍯
31⁄2⍯ 57⁄16⍯ 15⍯ 31⁄2⍯ 61⁄8⍯ 15⍯ 61⁄4⍯
4⍯ 57⁄16⍯ 15⍯ 4⍯ 61⁄8⍯ 15⍯ 61⁄4⍯
Type T Dimensions – Threaded & Set Screw
Conduit
Size A B C D E F
1⁄2⍯ 15⁄16⍯ 327⁄32⍯ 1⁄2⍯ 13⁄8⍯ 427⁄32⍯ 21⁄16⍯
3⁄4⍯ 117⁄16⍯ 439⁄64⍯ 3⁄4⍯ 141⁄64⍯ 519⁄32⍯ 211⁄32⍯
1⍯ 125⁄32⍯ 53⁄8⍯ 1⍯ 129⁄32⍯ 61⁄2⍯ 219⁄32⍯
11⁄4⍯ 21⁄2⍯ 71⁄4⍯ 11⁄4⍯ 23⁄4⍯ 81⁄2⍯ 335⁄64⍯
11⁄2⍯ 21⁄2⍯ 71⁄4⍯ 11⁄2⍯ 23⁄4⍯ 81⁄2⍯ 335⁄64⍯
2⍯ 31⁄4⍯ 97⁄16⍯ 2⍯ 327⁄64⍯ 1013⁄16⍯ 43⁄64⍯
21⁄2⍯ 41⁄2⍯ 121⁄4⍯ 21⁄2⍯ 41⁄2⍯ 13⍯ 525⁄32⍯
3⍯ 41⁄2⍯ 121⁄4⍯ 3⍯ 41⁄2⍯ 13⍯ 525⁄32⍯
31⁄2⍯ 51⁄2⍯ 15⍯ 31⁄2⍯ 59⁄16⍯ 165⁄16⍯ 613⁄16⍯
4⍯ 51⁄2⍯ 15⍯ 4⍯ 59⁄16⍯ 165⁄16⍯ 613⁄16⍯
STIBOINFO((CRH:66008com:CP:290))
PDFINFO CH0 0 9 F - 2
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0291-4 Name: CP-291 DATE: JAN 19 2006 Time: 5:15:15 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
ɀ CP Outlet Bodies
Applications
Form 5 Malleable Iron Conduit Bodies are used in conduit systems to:
ɀ Act as pull outlets for conductors being installed
ɀ Provide openings for making splices and taps in conductors
ɀ Act as mounting outlets for lighting fixtures and wiring devices
ɀ Connect conduit sections
ɀ Provide taps for branch conduit runs
ɀ Make 90 degree bends in conduit runs
ɀ Provide for access to conductors for maintenance and future system changes
Features
ɀ Interchangeable with Appleton Form 35® Conduit Bodies
ɀ Built–in rollers on 11⁄4⍯ to 4⍯ C and LB bodies to facilitate wire pulling
ɀ Smooth and rounded integral bushings for protection of wire insulation
ɀ Solid neoprene gaskets may be converted to open type by pulling out perforated center
section
ɀ Stainless steel cover screws
ɀ Domed sheet steel covers provide additional cubic capacity
Standard Materials
ɀ Bodies – Malleable iron
ɀ Gaskets – Neoprene
ɀ Covers – sheet steel or malleable
ɀ Cover screws – stainless steel
Standard Finishes
ɀ Malleable iron – electrogalvanized and aluminum acrylic paint
ɀ Neoprene – natural
ɀ Sheet steel – electrogalvanized
ɀ Stainless steel – natural
STIBOINFO((CRH:66008com:CP:291))
PDFINFO CH0 9 F - 1 7
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0292-12 Name: CP-292 DATE: JAN 19 2006 Time: 5:15:17 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
Ordering Information
ɀ CP Outlet Bodies
Internal Internal
Volume Unit Std. Max. # of Volume Unit Std. Max. # of
Cat.# Size (Cu. In.) Qty Pkg Conductors Cat.# Size (Cu. In.) Qty Pkg Conductors
Type LB ‡ Type LR ‡
LB50M 1⁄2⍯ 4.5 10 10 N/A LR50M 1⁄2⍯ 4.5 10 10 N/A
LB75M 3⁄4⍯ 7.5 10 10 3 #6 AWG MAX. LR75M 3⁄4⍯ 7.5 10 10 3 #6 AWG MAX.
LB100M 1⍯ 12.5 10 10 3 #4 XHHW MAX. LR100M 1⍯ 12.5 10 10 3 #4 XHHW MAX.
LB125M† 11⁄4⍯ 32.0 5 5 3 #2 XHHW MAX. LR125M 11⁄4⍯ 32.0 5 5 3 #2 XHHW MAX.
LB150M† 11⁄2⍯ 35.3 5 5 3 #1/0 XHHW MAX. LR150M 11⁄2⍯ 35.3 5 5 3 #2 XHHW MAX.
LB200M† 2⍯ 73.0 1 1 3 #4/0 XHHW MAX. LR200M 2⍯ 68.0 1 1 3 #4/0 XHHW MAX.
LB250M† 21⁄2⍯ 142.0 1 1 3 #300 MCM XHHW MAX. LR250M 21⁄2⍯ 142.0 1 1 3 #300 MCM XHHW MAX.
LB300M† 3⍯ 173.0 1 1 3 #400 MCM XHHW MAX. LR300M 3⍯ 173.0 1 1 3 #350 MCM XHHW MAX.
LB350M† 31⁄2⍯ 292.0 1 1 3 #500 MCM XHHW MAX. LR350M 31⁄2⍯ 292.0 1 1 3 #350 MCM XHHW MAX.
LB400M† 4⍯ 324.0 1 1 3 #500 MCM XHHW MAX. LR400M 4⍯ 324.0 1 1 3 #350 MCM XHHW MAX.
Type LL ‡ Type T ‡
LL50M 1⁄2⍯ 4.5 10 10 N/A T50M 1⁄2⍯ 6.0 10 10 N/A
LL75M 3⁄4⍯ 7.5 10 10 3 #6 AWG MAX. T75M 3⁄4⍯ 9.5 10 10 3 #6 AWG MAX.
LL100M 1⍯ 12.5 10 10 3 #4 XHHW MAX. T100M 1⍯ 15.0 10 10 3 #4 XHHW MAX.
LL125M 11⁄4⍯ 32.0 5 5 3 #2 XHHW MAX. T125M 11⁄4⍯ 33.0 5 5 3 #2 XHHW MAX.
LL150M 11⁄2⍯ 33.0 5 5 3 #2 XHHW MAX. T150M 11⁄2⍯ 36.0 5 5 3 #1 XHHW MAX.
LL200M 2⍯ 68.0 1 1 3 #4/0 XHHW MAX. T200M 2⍯ 76.0 1 1 3 #2/0 XHHW MAX.
LL250M 21⁄2⍯ 142.0 1 1 3 #300 MCM XHHW MAX. T250M 21⁄2⍯ 142.0 1 1 3 #300 MCM XHHW MAX.
LL300M 3⍯ 173.0 1 1 3 #350 MCM XHHW MAX. T300M 3⍯ 173.0 1 1 3 #300 MCM XHHW MAX.
LL350M 31⁄2⍯ 292.0 1 1 3 #350 MCM XHHW MAX. T350M 31⁄2⍯ 292.0 1 1 3 #350 MCM XHHW MAX.
LL400M 4⍯ 324.0 1 1 3 #350 MCM XHHW MAX. T400M 4⍯ 324.0 1 1 3 #350 MCM XHHW MAX.
Type C ‡ Type TB
C50M 1⁄2⍯ 4.5 10 10 N/A TB50M 1⁄2⍯ 6.0 10 10 N/A
C75M 3⁄4⍯ 7.5 10 10 3 #6 AWG MAX. TB75M 3⁄4⍯ 9.5 10 10 3 #6 AWG MAX.
C100M 1⍯ 12.5 10 10 3 #4 XHHW MAX. TB100M 1⍯ 15.0 10 10 3 #6 AWG MAX.
C125M† 11⁄4⍯ 35.0 5 5 3 #2 XHHW MAX. TB125M 11⁄4⍯ 33.0 5 5 3 #6 AWG MAX.
C150M† 11⁄2⍯ 35.3 5 5 3 #1/0 XHHW MAX. TB150M 11⁄2⍯ 36.0 5 5 3 #4 XHHW MAX.
C200M† 2⍯ 75.0 1 1 3 #4/0 XHHW MAX. TB200M 2⍯ 76.0 1 1 3 #1/0 XHHW MAX.
C250M† 21⁄2⍯ 153.0 1 1 3 #300 MCM XHHW MAX.
3⍯ 181.0 1 1 Type X
C300M† 3 #300 MCM XHHW MAX.
1⁄2⍯
C350M† 31⁄2⍯ 290.0 1 1 3 #350 MCM XHHW MAX. X50M 6.0 10 10 N/A
3⁄4⍯ 9.5 10 10
C400M† 4⍯ 320.0 1 1 3 #350 MCM XHHW MAX. X75M 3 #6 AWG MAX.
X100M 1⍯ 15.0 10 10 3 #4 XHHW MAX.
† 1 1/4⍯ - 4⍯ LB and C Bodies supplied with built in rollers to facilitate wire pulling. X125M 11⁄4⍯ 33.0 5 5 3 #2 XHHW MAX.
‡ SnapPack TM pre-packaged body, cover and neoprene gasket - add suffix CG. X150M 11⁄2⍯ 36.0 5 5 3 #1/0 XHHW MAX.
Available on sizes 1/2⍯–2⍯ X200M 2⍯ 76.0 1 1 3 #2/0 XHHW MAX.
STIBOINFO((CRH:66008com:CP:292))
PDFINFO CH0 0 9 F - 2
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0293-2 Name: CP-293 DATE: JAN 19 2006 Time: 5:15:18 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
(in inches)
ɀ CP Outlet Bodies
Form 5 Iron LB
Size 1⁄2 3⁄4 1 11⁄4 11⁄2 2 21⁄2 3 31⁄2 4
A 1.34 1.50 1.80 2.60 2.60 3.12 4.31 4.31 5.62 5.62
B 4.68 5.37 6.20 8.12 8.12 10.50 13.60 13.87 16.25 16.60
C 2.05 2.25 2.65 2.75 2.83 4.42 5.40 5.90 6.90 7.21
Form 5 Iron LL
Size 1⁄2 3⁄4 1 11⁄4 11⁄2 2 21⁄2 3 31⁄2 4
A 2.05 2.25 2.65 2.75 3.50 4.12 5.71 5.87 7.13 7.13
B 4.68 5.37 6.20 8.12 8.12 10.50 13.60 13.87 16.50 16.50
C 1.37 1.70 1.90 2.75 2.83 3.31 3.90 4.75 6.81 7.19
Form 5 Iron LR
Size 1⁄2 3⁄4 1 11⁄4 11⁄2 2 21⁄2 3 31⁄2 4
A 2.05 2.25 2.65 2.75 3.50 4.12 5.71 5.87 6.10 6.95
B 4.68 5.37 6.20 8.12 8.12 10.50 13.60 13.87 6.25 16.25
C 1.37 1.70 1.90 2.75 2.83 3.31 3.90 4.75 5.62 5.62
Form 5 Iron C
Size 1⁄2 3⁄4 1 11⁄4 11⁄2 2 21⁄2 3 31⁄2 4
A 1.34 1.50 1.80 2.60 2.60 3.12 4.31 4.31 4.88 4.88
B 5.38 6.00 7.05 9.00 9.00 11.50 15.00 15.12 18.13 18.13
C 1.37 1.70 1.90 2.75 2.83 3.31 3.90 4.75 5.19 5.56
Form 5 Iron T
Size 1⁄2 3⁄4 1 11⁄4 11⁄2 2 21⁄2 3 31⁄2 4
A 2.05 2.25 2.65 2.75 3.50 4.12 5.71 5.87 6.81 7.15
B 5.38 6.00 7.05 9.00 9.00 11.50 15.00 15.12 18.13 18.13
C 1.34 1.50 1.80 2.60 2.60 3.12 4.31 4.31 5.19 5.56
Form 5 Iron TB
Size 1⁄2 3⁄4 1 11⁄4 11⁄2 2
A 1.34 1.50 1.80 2.60 2.60 3.12
B 5.38 6.00 7.05 9.00 9.00 11.50
C 2.05 2.25 2.65 2.75 2.83 4.42
Form 5 Type X
Size 1⁄2 3⁄4 1 11⁄4 11⁄2 2
A 2.79 2.93 3.56 4.43 4.43 5.4
B 5.41 6.08 7.1 9.1 9.1 11.75
C 1.75 1.97 2.25 2.55 2.75 3.45
STIBOINFO((CRH:66008com:CP:293))
PDFINFO CH0 0 9 F - 2
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0294-2 Name: CP-294 DATE: JAN 19 2006 Time: 5:15:20 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
CP Sealing Locknuts
Weight
Unit Standard Lbs. Per
Cat. # Size Quantity Package 100
SL1 1⁄2⍯ 100 100 2
SL2 3⁄4⍯ 50 500 2
SL3 1⍯ 25 250 3
SL4 11⁄4⍯ 25 250 8
SL5 11⁄2⍯ 25 100 10
SL6 2⍯ 25 100 14
SL7 21⁄2⍯ 10 50 36
SL8 3⍯ 10 50 38
SL9 31⁄2⍯ 10 50 58
SL10 4⍯ 5 25 72
SL11 5⍯ 2 2 110
SL12 6⍯ 1 1 190
STIBOINFO((CRH:66008com:CP:294))
PDFINFO CH0 9 F - 1 8
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0295-7 Name: CP-295 DATE: JAN 19 2006 Time: 5:15:21 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
Standard Materials:
ɀ CP Liquidtight
ɀ Body – Straight: 3⁄8⍯ through 6⍯ – malleable iron or aluminum
45° and 90°; 3⁄8⍯ through 4⍯ – malleable iron or aluminum
ɀ Gland nut – malleable iron or aluminum
ɀ Ferrule – 3⁄8⍯ through 6⍯ – steel
ɀ Gland nut sealing ring – polyethylene
ɀ Sealing gasket – thermoplastic elastomer
ɀ Locknut – steel
Standard Finishes:
ɀ Steel and malleable iron – zinc electroplate
UL File No. E-19189 ɀ Polyethylene, thermoplastic elastomer, aluminum and die cast –
Applications: natural
Typical applications for liquidtight conduit and the Liquidator include User Benefits
the wiring of machine tools . . . motors . . . transformers . . . food ɀ Assurance of safe and reliable performance. End user peace of
processing equipment . . . robotics . . . air conditioning units . . . mind.
illuminated store front signs and billboards . . . etc. The flexible ɀ Meets NEC and UL requirements for use in wet locations. Reduces
metallic conduit and fittings protect conductors from mechanical downtime and replacement costs.
ɀ Complete selection of styles and sizes. Easy selection from one
damage due to vibration and movement and seals out cutting oils, source, saves time and money.
coolants, water, dust, etc. ɀ High strength and excellent corrosion resistance. Long service life,
Applications such as these can be found in, but are not limited to, eliminates the need for replacement.
industries such as: ɀ Provides excellent pullout strength and grounding for safety of
ɀ machine tool manufacturers. personnel and equipment.
ɀ Easy to install. Cannot be installed incorrectly. Saves labor.
ɀ electric power generating plants. ɀ Eliminates leakage, potential downtime and replacement costs.
ɀ waste treatment facilities. Protection against vibration.
ɀ paint manufacturing facilities. ɀ Can be disassembled and reused. Cost savings.
ɀ automobile manufacturing facilities. ɀ Easy wrenching, Fast, easy installation results in labor savings.
ɀ aerospace industries. ɀ Eliminates leakage, potential downtime and replacement costs.
ɀ breweries. ɀ Provides a reliable ground and safety of personnel and equipment.
ɀ food processing plants. Won’t vibrate loose.
ɀ dairies. ɀ One-stop source to meet user needs. Saves time and money.
ɀ pulp and paper mills. STRAIGHT CONNECTORS – NON-INSULATED – MALLEABLE
ɀ petroleum refineries. IRON
ɀ chemical and petrochemical plants. Weight
Conduit Unit Standard Lbs. Per
Compliances: Cat. # Size Quantity Package 100
ɀ NEC: Class I, Division 2 3⁄8⍯
Class II, Divisions 1 and 2 LT-38 25 100 18
LT-50 1⁄2⍯ 25 100 20
Class III, Divisions 1 and 2 3⁄4⍯
ɀ UL Standards: 514B, 467 LT-75 25 100 26
ɀ CSA Standard: C22.2 No. 18 LT-100 1⍯ 5 50 45
LT-125 11⁄4⍯ 5 25 69
FEATURES AND BENEFITS: LT-150 11⁄2⍯ 2 20 85
Product Features LT-200 2⍯ 1 10 120
ɀ UL and cUL Listed LT-250 21⁄2⍯ 1 5 340
ɀ Provided protection in wet locations LT-300 3⍯ 1 5 430
ɀ Straight available in 3⁄8⍯ through 6⍯ sizes; 45° and 90° available in
3⁄8⍯ through 4⍯ sizes.
LT-350 31⁄2⍯ 1 5 510
LT-400 4⍯ 1 5 600
ɀ Malleable iron bodies and gland nuts with zinc electroplate; steel
LT-500† 5⍯ 1 1 800
ferrules and locknuts with zinc electroplate.
LT-600† 6⍯ 1 1 1075
ɀ Cupped grounding ferrule is distortion-free and reusable.
† Not UL Listed or CSA Certified
ɀ Split polyethylene sealing ring is reversible.
ɀ Grooves inside sealing ring. Jacket of liquidtight conduit will cold STRAIGHT CONNECTORS – INSULATED – MALLEABLE IRON
flow into grooves.
3⁄8⍯
ɀ Reusable design. LTB-38 25 100 18
1⁄2⍯
ɀ Hex surfaces on gland nut and body. LTB-50 25 100 20
3⁄4⍯
ɀ Thermoplastic elastomer sealing gasket effectively seals out water, LTB-75 25 100 26
oil, dust and dirt. LTB-100 1⍯ 5 50 45
ɀ Steel locknut bites into box. LTB-125 11⁄4⍯ 5 25 69
ɀ Available with or without insulated throats. LTB-150 11⁄2⍯ 2 20 86
ɀ Insulated throat versions, 105°C rated nylon. LTB-200 2⍯ 1 10 120
LTB-250 21⁄2⍯ 1 5 340
LTB-300 3⍯ 1 5 430
LTB-350 31⁄2⍯ 1 5 510
LTB-400 4⍯ 1 5 600
LTB-500† 5⍯ 1 1 800
LTB-600† 6⍯ 1 1 1075
† Not UL Listed or CSA certified
STIBOINFO((CRH:66008com:CP:295))
PDFINFO CH0 9 F - 1 9
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0296-3 Name: CP-296 DATE: JAN 19 2006 Time: 5:15:23 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
STRAIGHT CONNECTORS – NON-INSULATED – ALUMINUM 90° ANGLE CONNECTOR – INSULATED – MALLEABLE IRON
Weight Weight
Conduit Unit Standard Lbs. Per Conduit Unit Standard Lbs. Per
ɀ CP Liquidtight
Cat. # Size Quantity Package 100 Cat. # Size Quantity Package 100
LT38-SA 3⁄8⍯ 25 100 12 LTB-3890 3⁄8⍯ 25 100 30
LT50-SA 1⁄2⍯ 25 100 12 LTB-5090 1⁄2⍯ 25 100 33
LT75-SA 3⁄4⍯ 25 100 14 LTB-7590 3⁄4⍯ 10 50 48
LT100-SA 1⍯ 10 50 28 LTB-10090 1⍯ 10 50 76
LT125-SA 11⁄4⍯ 5 25 34 LTB-12590 11⁄4⍯ 5 25 112
LT150-SA 11⁄2⍯ 2 20 48 LTB-15090 11⁄2⍯ 2 10 155
LT200-SA 2⍯ 1 10 54 LTB-20090 2⍯ 1 5 230
LT250-SA 21⁄2⍯ 1 5 121
LTB-25090 21⁄2⍯ 1 1 900
LT300-SA 3⍯ 1 5 174 LTB-30090 3⍯ 1 1 1380
LT350-SA 31⁄2⍯ 1 5 245
LT400-SA 4⍯ 1 5 279 LTB-35090 31⁄2⍯ 1 1 1825
LTB-40090 4⍯ 1 1 2325
45° ANGLE CONNECTORS — NON-INSULATED – MALLEABLE
IRON 90° ANGLE CONNECTOR – NON-INSULATED – ALUMINUM
LT-3845 3⁄8⍯ 25 100 27
LT3890-SA 3⁄8⍯ 25 100 19
LT-5045 1⁄2⍯ 25 100 29
LT5090-SA 1⁄2⍯ 25 100 18
LT-7545 3⁄4⍯ 10 50 41
LT7590-SA 3⁄4⍯ 10 50 24
LT-10045 1⍯ 10 50 70
LT-12545 11⁄4⍯ 5 25 93 LT10090-SA 1⍯ 10 50 40
LT-15045 11⁄2⍯ 2 10 137 LT12590-SA 11⁄4⍯ 5 25 48
LT15090-SA 11⁄2⍯ 2 10 61
LT-20045 2⍯ 1 5 199
LT-25045 21⁄2⍯ 1 1 600 LT20090-SA 2⍯ 1 5 86
LT-30045 3⍯ 1 1 925
COMBINATION COUPLINGS FOR COUPLING LIQUIDTIGHT TO
LT-35045 31⁄2⍯ 1 1 1150
THREADED RIGID/IMC CONDUIT
LT-40045 4⍯ 1 1 1450
LTR-38* 3⁄8⍯ 25 100 17
45° ANGLE CONNECTORS – INSULATED – MALLEABLE IRON
LTR-50 1⁄2⍯ 25 100 29
LTB-3845 3⁄8⍯ 25 100 27 3⁄4⍯
LTR-75 25 100 33
LTB-5045 1⁄2⍯ 25 100 29
3⁄4⍯
LTR-100 1⍯ 5 50 59
LTB-7545 10 50 41
LTR-125 11⁄4⍯ 2 20 105
LTB-10045 1⍯ 10 50 70 LTR-150 11⁄2⍯ 2 20 105
LTB-12545 11⁄4⍯ 5 25 93
LTR-200 2⍯ 1 10 160
LTB-15045 11⁄2⍯ 2 10 137
* For 3⁄8⍯ Liquidtight to 1⁄2⍯ Rigid/IMC
LTB-20045 2⍯ 1 5 195
LTB-25045 21⁄2⍯ 1 1 600
LTB-30045 3⍯ 1 1 925
SELF RETAINING PVC GASKET WITH STEEL RING
UL File no. E-22133 Weight
LTB-35045 31⁄2⍯ 1 1 1150
LTB-40045 4⍯ 1 1 1450 Conduit Unit Standard Lbs. Per
Cat. # Size Quantity Package 100
90° ANGLE CONNECTORS – NON-INSULATED – MALLEABLE 3⁄8⍯–1⁄2⍯
SG1 100 100 1
IRON 3⁄4⍯
SG2 50 50 2
LT-3890 3⁄8⍯ 25 100 31 SG3 1⍯ 50 50 2
LT-5090 1⁄2⍯ 25 100 33 SG4 11⁄4⍯ 25 25 2
LT-7590 3⁄4⍯ 10 50 48 SG5 11⁄2⍯ 25 25 4
LT-10090 1⍯ 10 50 76 SG6 2⍯ 25 25 3
LT-12590 11⁄4⍯ 5 25 112 SG7 21⁄2⍯ 10 10 5
LT-15090 11⁄2⍯ 2 10 155 SG8 3⍯ 10 10 10
LT-20090 2⍯ 1 5 230 SG9 31⁄2⍯ 10 10 12
LT-25090 21⁄2⍯ 1 1 900 SG10 4⍯ 10 10 10
LT-30090 3⍯ 1 1 1383 SG11 5⍯ 5 5 15
LT-35090 31⁄2⍯ 1 1 1875 SG12 6⍯ 5 5 22
LT-40090 4⍯ 1 1 2325
STIBOINFO((CRH:66008com:CP:296))
PDFINFO CH0 9 F - 2 0
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0297-5 Name: CP-297 DATE: JAN 19 2006 Time: 5:15:24 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
ɀ CP Liquidtight
Weight
Conduit Lug Unit Std. Lbs.
For Liquidtight
Per
Flexible Steel Conduit
Cat. # Size Size Qty. Pkg. 100
LT38G 3⁄8⍯ #4-#14 25 100 18
LT50G 1⁄2⍯ #4-#14 25 100 20
LT75G 3⁄4⍯ #4-#14 25 100 26
LT100G 1⍯ #4-#14 5 50 45
LT125G 11⁄4⍯ #4-#14 5 25 69
LT150G 11⁄2⍯ #4-#14 2 20 85
LT200G 2⍯ #4-#14 1 10 120
LT250G 21⁄2⍯ #1/0-#8 1 5 340
LT300G 3⍯ #1/0-#8 1 5 430
LT350G 31⁄2⍯ #3/0-#6 1 5 510
UL File No. E-6225 LT400G 4⍯ #3/0-#6 1 5 600
Application: LT500G† 5⍯ 250MCM-#6 1 1 800
Lazy-Lug liquidtight conduit fittings provide an easy, versatile method LT600G† 6⍯ 250MCM-#6 1 1 1100
to use an external grounding conductor with liquidtight flexible metallic STRAIGHT CONNECTORS – INSULATED – MALLEABLE IRON –
conduit as permitted by the National Electrical Code. This section ALUMINUM LUG
allows an external bonding jumper to be used with a 6-foot or shorter
length of liquidtight conduit. LTB38G 3⁄8⍯ #4-#14 25 100 18
LTB50G 1⁄2⍯ #4-#14 25 100 20
Features/Benefits:
3⁄4⍯
ɀ Open lug design allows installer to quickly lay in the grounding LTB75G #4-#14 25 100 26
conductor. LTB100G 1⍯ #4-#14 5 50 45
ɀ Aluminum lug – for copper or aluminum grounding conductors. LTB125G 11⁄4⍯ #4-#14 5 25 69
ɀ Copper lug – for copper grounding conductors. LTB150G 11⁄2⍯ #4-#14 2 20 86
Compliance: LTB200G 2⍯ #4-#14 1 10 120
UL Standard 514B – Fittings for Conduit and Outlet Boxes LTB250G 21⁄2⍯ #1/0-#8 1 5 340
UL Standard 467 – Grounding and Bonding Equipment LTB300G 3⍯ #1/0-#8 1 5 430
LTB350G 31⁄2⍯ #3/0-#6 1 5 510
LTB400G 4⍯ #3/0-#6 1 5 600
LTB500G† 5⍯ 250MCM-#6 1 1 720
LTB600G† 6⍯ 250MCM-#6 1 1 750
† Not UL Listed
Note: For other connector and lug combinations,
consult factory.
STRAIGHT CONNECTORS – NON-INSULATED – ALUMINUM –
ALUMINUM LUG
STIBOINFO((CRH:66008com:CP:297))
PDFINFO CH0 9 F - 2 2
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0298-4 Name: CP-298 DATE: JAN 19 2006 Time: 5:15:25 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
Weight
Conduit Lug Unit Std. Lbs. Per STRAIGHT CONNECTORS – INSULATED – COPPER LUG
Cat. # Size Size Qty. Pkg. 100
LTB3845G 3⁄8⍯ #4-#14 25 100 29 Weight
LTB5045G 1⁄2⍯ #4-#14 25 100 41 Conduit Lug Unit Std. Lbs. Per
LTB7545G 3⁄4⍯ #4-#14 10 50 41 Cat. # Size Size Qty. Pkg. 100
LTB38GC 3⁄8⍯ #4-#14 25 100 20
LTB10045G 1⍯ #4-#14 10 50 70 1⁄2⍯
LTB12545G 11⁄4⍯ #4-#14 5 25 93 LTB50GC #4-#14 25 100 22
LTB75GC 3⁄4⍯ #4-#14 25 100 28
LTB15045G 11⁄2⍯ #4-#14 2 10 137
LTB20045G 2⍯ #4-#14 1 5 195 LTB100GC 1⍯ #4-#14 5 50 47
LTB25045G 21⁄2⍯ #1/0-# 1 1 600 LTB125GC 11⁄4⍯ #4-#14 5 25 71
LTB30045G 3⍯ #1/0-#8 1 1 925 LTB150GC 11⁄2⍯ #4-#14 2 20 88
LTB35045G 31⁄2⍯ #3/0-#6 1 1 1150 LTB200GC 2⍯ #4-#14 1 10 122
LTB40045G 4⍯ #3/0-#6 1 1450 LTB250GC 21⁄2⍯ #1/0-#8 1 5 351
LTB300GC 3⍯ #1/0-#8 1 5 441
90° ANGLE CONNECTORS – NON-INSULATED – MALLEABLE
IRON – ALUMINUM LUG LTB350GC 31⁄2⍯ #3/0-#6 1 5 532
LTB400GC 4⍯ #3/0-#6 1 5 622
LT3890G 3⁄8⍯ #4-#14 25 100 32 45° ANGLE CONNECTORS – INSULATED – COPPER LUG
LT5090G 1⁄2⍯ #4-#14 25 100 33
LT7590G 3⁄4⍯ #4-#14 10 50 48 LTB3845GC 3⁄8⍯ #4-#14 25 100 31
LT10090G 1⍯ #4-#14 10 50 76 LTB5045GC 1⁄2⍯ #4-#14 25 100 43
LT12590G 11⁄4⍯ #4-#14 5 25 112 LTB7545GC 3⁄4⍯ #4-#14 10 50 43
LT15090G 11⁄2⍯ #4-#14 2 10 155 LTB10045GC 1⍯ #4-#14 10 50 72
LT20090G 2⍯ #4-#14 1 5 230 LTB12545GC 11⁄4⍯ #4-#14 5 25 95
LT25090G 21⁄2⍯ #1/0-#8 1 1 900 LTB15045GC 11⁄2⍯ #4-#14 2 10 139
LT30090G 3⍯ #1/0-#8 1 1 1383 LTB20045GC 2⍯ #4-#14 1 5 197
LT35090G 31⁄2⍯ #3/0-#6 1 1 1875 LTB25045GC 21⁄2⍯ #1/0-#8 1 1 611
LT40090G 4⍯ #3/0-#6 1 1 2325 LTB30045GC 3⍯ #1/0-#8 1 1 936
LTB35045GC 31⁄2⍯ #3/0-#6 1 1 1172
90° ANGLE CONNECTORS – INSULATED – MALLEABLE IRON — LTB40045GC 4⍯ #3/0-#6 1 1 1472
ALUMINUM LUG
90° ANGLE CONNECTORS – INSULATED – COPPER LUG
LTB3890G 3⁄8⍯ #4-#14 25 100 30
LTB5090G 1⁄2⍯ #4-#14 25 100 33 LTB3890GC 3⁄8⍯ #4-#14 25 100 32
LTB7590G 3⁄4⍯ #4-#14 10 50 48 LTB5090GC 1⁄2⍯ #4-#14 25 100 35
LTB7590GC 3⁄4⍯ #4-#14 10 50 50
LTB10090G 1⍯ #4-#14 10 50 76
LTB12590G 11⁄4⍯ #4-#14 5 25 112 LTB10090GC 1⍯ #4-#14 10 50 78
LTB15090G 11⁄2⍯ #4-#14 2 155 LTB12590GC 11⁄4⍯ #4-#14 5 25 114
LTB15090GC 11⁄2⍯ #4-#14 2 10 157
LTB20090G 2⍯ #4-#14 1 5 230
LTB25090G 21⁄2⍯ #1/0-#83 1 1 900 LTB20090GC 2⍯ #4-#14 1 5 232
LTB30090G 3⍯ #1/0-#8 1 1 1300 LTB25090GC 21⁄2⍯ #1/0-#8 1 1 911
LTB30090GC 3⍯ #1/0-#8 1 1 1311
LTB35090G 31⁄2⍯ #3/0-#6 1 1 1800
LTB40090G 4⍯ #3/0-#6 1 1 2300 LTB35090GC 31⁄2⍯ #3/0-#6 1 1 1822
LTB40090GC 4⍯ #3/0-#6 1 1 2322
90° ANGLE CONNECTORS – NON-INSULATED – ALUMINUM Note: For other connector and lug combinations,
ALUMINUM LUG consult factory.
STIBOINFO((CRH:66008com:CP:298))
PDFINFO CH0 9 F - 2 3
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0299-32 Name: CP-299 DATE: JAN 19 2006 Time: 5:15:26 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
ɀ CP Liquidtight
TYPE – ALUMINUM LUG No disassembly required! The LiQuik liquidlight fittings are quick and
easy to install in 2 steps, offering huge labor saving potential.
Weight Available in trade sizes 3⁄8⍯–2⍯ straight insulated.
Conduit Lug Size Unit Std. Lbs. per
Cat. # Size Qty. Pkg. 100 New LiQuik Assembly Installation
LTR38G* 3⁄8⍯ #4-#14 25 100 24
1⁄2⍯ 1. Slide conduit inside the fully assembled
LTR50G #4-#14 25 100 30
3⁄4⍯ connector.
LTR75G #4-#14 25 100 35
LTR100G 1⍯ #4-#14 5 50 59
2. Turn the connector assembly or the
LTR125G 11⁄4⍯ #4-#14 5 25 81
conduit until the ferrule threads engage
LTR150G 11⁄2⍯ #4-#14 2 20 107
the spirals in the conduit. The pins in the
LTR200G 2⍯ #4-#14 1 10 162 ferrule are locked inside the holes in the
* For 3⁄8⍯ Liquidtight to 1⁄2⍯ Rigid/IMC connector body, preventing the ferrule from turning. Tighten the nut
against the connector.
Note: For other connector and lug combinations,
consult factory. LiQuik TM LIQUIDTIGHT FITTINGS – STRAIGHT,
Copper lugs are available also. Consult factory for NON-INSULATED
details.
STIBOINFO((CRH:66008com:CP:299))
PDFINFO CH0 9 F - 2 4
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0300-2 Name: CP-300 DATE: JAN 19 2006 Time: 5:15:28 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
Applications
Flexible metalic (liquidtight) conduit used with Cooper Crouse-Hinds® Liquidtight fittings is designed to protect conductors from mechanical
damage due to vibration and movement while sealing out cutting oils, coolants, water, dust, ect. Typical applications include the wiring of
ɀ CP Liquidtight
machine tools, motors, transformers, food processing equipment, robotics, air conditioning units, illuminated signs, etc.
The low profile liquidtight fittings are designed specifically for OEM applications that require close side-by-side mounting of multiple liquidtight
fittings in tight spaces.
Ordering Information:
Straight Connectors 45° Connectors 90° Connectors
Conduit Non-insulated Insulated Conduit Non-insulated Insulated Conduit Non-insulated Insulated
Size Cat.No. Cat.No. Size Cat.No. Cat.No. Size Cat.No. Cat.No.
3⁄8⍯ LTK38 LTBK38 3⁄8⍯ LTK3845 LTBK3845 3⁄8⍯ LTK3890 LTBK3890
1⁄2⍯ LTK50 LTBK50 1⁄2⍯ LTK5045 LTBK5045 1⁄2⍯ LTK5090 LTBK5090
3⁄4⍯ LTK75 LTBK75 3⁄4⍯ LTK7545 LTBK7545 3⁄4⍯ LTK7590 LTBK7590
1⍯ LTK100 LTBK100 1⍯ LTK10045 LTBK10045 1⍯ LTK10090 LTBK10090
11⁄4⍯ LTK125 LTBK125 11⁄4⍯ LTK12545 LTBK12545 11⁄4⍯ LTK12590 LTBK12590
11⁄2⍯ LTK150 LTBK150 11⁄2⍯ LTK15045 LTBK15045 11⁄2⍯ LTK15090 LTBK15090
2⍯ LTK200 LTBK200 2⍯ LTK20045 LTBK20045 2⍯ LTK20090 LTBK20090
STIBOINFO((CRH:66008com:CP:300))
PDFINFO CH0 9 F - 2 5
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0301-3 Name: CP-301 DATE: JAN 19 2006 Time: 5:15:29 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
Applications Features
STRAIGHT BODY Trade Color Cable Range Unit Std. Wt. Lbs.
Cat. # Size Code Min. Max. Quantity Pkg. Per 100
CG50-250 1⁄2⍯ Red 0.15 0.25 25 100 10
CG50-350 1⁄2⍯ White 0.25 0.35 25 100 10
CG50-450 1⁄2⍯ Blue 0.35 0.45 25 100 10
CG50-560 1⁄2⍯ Green 0.45 0.56 25 100 10
CG50-650 1⁄2⍯ Brown 0.55 0.65 25 100 10
CG75-250 3⁄4⍯ Red 0.15 0.25 10 50 14
CG75-350 3⁄4⍯ White 0.25 0.35 10 50 14
CG75-450 3⁄4⍯ Blue 0.35 0.45 10 50 14
CG75-560 3⁄4⍯ Green 0.45 0.56 10 50 14
CG75-650 3⁄4⍯ Brown 0.55 0.65 10 50 14
CG75-750 3⁄4⍯ Yellow 0.65 0.75 10 50 14
CG75-850 3⁄4⍯ Purple 0.75 0.85 10 50 14
CG100-560 1⍯ Green 0.45 0.56 5 25 20
CG100-650 1⍯ Brown 0.55 0.65 5 25 20
CG100-750 1⍯ Yellow 0.65 0.75 5 25 20
CG100-850 1⍯ Purple 0.75 0.85 5 25 20
CG100-950 1⍯ Gray 0.85 0.95 5 25 20
CG100-1050 1⍯ Black 0.95 1.05 5 25 20
CG125-850 1-1⁄4⍯ Purple 0.75 0.85 5 25 40
CG125-950 1-1⁄4⍯ Gray 0.85 0.95 5 25 40
CG125-1050 1-1⁄4⍯ Black 0.95 1.05 5 25 40
CG125-1150 1-1⁄4⍯ Orange 1.05 1.15 5 25 40
CG125-1250 1-1⁄4⍯ Red 1.15 1.25 5 25 40
CG125-1375 1-1⁄4⍯ White 1.25 1.375 5 25 40
CG150-1050 1-1⁄2⍯ Black 0.95 1.05 2 10 70
CG150-1150 1-1⁄2⍯ Orange 1.05 1.15 2 10 70
CG150-1250 1-1⁄2⍯ Red 1.15 1.25 2 10 70
CG150-1375 1-1⁄2⍯ White 1.25 1.375 2 10 70
STIBOINFO((CRH:66008com:CP:301))
PDFINFO CH0 9 F - 2 6
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0302-2 Name: CP-302 DATE: JAN 19 2006 Time: 5:15:30 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
45° BODY
ɀ CP Cord and Cable
90° BODY Trade Color Cable Range Unit Std. Wt. Lbs.
Cat. # Size Code Min. Max. Quantity Pkg. Per 100
CG5090-250 1⁄2⍯ Red 0.15 0.25 10 50 26
CG5090-350 1⁄2⍯ White 0.25 0.35 10 50 26
CG5090-450 1⁄2⍯ Blue 0.35 0.45 10 50 26
CG5090-560 1⁄2⍯ Green 0.45 0.56 10 50 26
CG5090-650 1⁄2⍯ Brown 0.55 0.65 10 50 26
CG7590-250 3⁄4⍯ Red 0.15 0.25 10 50 48
CG7590-350 3⁄4⍯ White 0.25 0.35 10 50 48
CG7590-450 3⁄4⍯ Blue 0.35 0.45 10 50 48
CG7590-560 3⁄4⍯ Green 0.45 0.56 10 50 48
CG7590-650 3⁄4⍯ Brown 0.55 0.65 10 50 48
CG7590-750 3⁄4⍯ Yellow 0.65 0.75 10 50 48
CG7590-850 3⁄4⍯ Purple 0.75 0.85 10 50 48
CG10090-560 1⍯ Green 0.45 0.56 5 25 68
CG10090-650 1⍯ Brown 0.55 0.65 5 25 68
CG10090-750 1⍯ Yellow 0.65 0.75 5 25 68
CG10090-850 1⍯ Purple 0.75 0.85 5 25 68
CG10090-950 1⍯ Gray 0.85 0.95 5 25 68
CG10090-1050 1⍯ Black 0.95 1.05 5 25 68
STIBOINFO((CRH:66008com:CP:302))
PDFINFO CH0 9 F - 2 7
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0303-3 Name: CP-303 DATE: JAN 19 2006 Time: 5:15:31 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
Applications Features
For use with portable cord, NCG Series watertight cord grips terminate ɀ Available in 3⁄8⍯ to 1⍯ trade sizes.
Standard Materials
ɀ cable gland body and nut - polyamide 6
ɀ bushing - neoprene
ɀ locknut - polyamide 6
Ordering Information
TRADE SIZE CABLE RANGE INCHES
(MM) CATALOG NUMBER CARTON QTY.
3⁄8⍯ 0.1-0.35 (2.5-8) NCG38-35 25
1⁄2⍯ 0.20-0.50 (5-12) NCG50-50 25
3⁄4⍯ 0.35-0.75 (9-18) NCG75-75 25
1⍯ 0.55-1.00 (14-25) NCG100-100 20
STIBOINFO((CRH:66008com:CP:303))
PDFINFO CH0 9 F - 2 6
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0304-19 Name: CP-304 DATE: JAN 19 2006 Time: 5:15:32 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
Application:
ACC combination couplings are used to join EMT conduit to armored
cable, metal clad cable or flexible metallic conduit.
Wt
Features and Benefits: Cat Trade KO Cable Opening Dim Dim Unit Lbs./
ɀ Dual gripping saddle design on the coupling safely secures cable or # Size Size max. min. A B Qty 100
conduit in place and prevents loosening from vibration
SSACB38 3⁄8⍯ 1⁄2⍯ 0.640 0.280 13⁄8⍯ 3⁄4⍯ 50 9
ɀ Steel compression ring & nut provide a strong, secure termination
SSACB50 1⁄2⍯ 1⁄2⍯ 0.930 0.635 13⁄8⍯ 11⁄16⍯ 25 12
point for EMT conduit.
SSACB75 3⁄4⍯ 3⁄4⍯ 1.125 0.810 11⁄2⍯ 11⁄4⍯ 10 14
ɀ Tri–Head set screw may be installed using a slotted, Phillips or
Robertson head screwdriver.
ɀ Steel combination coupling is zinc electroplated for corrosion
resistance.
STIBOINFO((CRH:66008com:CP:304))
PDFINFO CH0 9 F - 2 8
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0305-8 Name: CP-305 DATE: JAN 19 2006 Time: 5:16:32 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
NON-METALLIC SHEATHED CABLE AND PORTABLE ARMORED CABLE AND FLEXIBLE METALLIC CONDUIT
ɀ CP Cable Fittings
CORD CONNECTORS – STEEL CONNECTORS – MALLEABLE IRON
Clamp Type Duplex Type
UL File No. E-22132 Wt UL File No. E-19188 Diam. of Diam. of Wt
Cat. K.O. Clamp Opening Unit Std Lbs./ Cat. Trade Opening Bushed Unit Std Lbs./
# Size Min. Max. Width Qty Pkg 100 # Size for Cable Hole Qty Pkg 100
631 3⁄4⍯ 33⁄64⍯ 13⁄16⍯ 13⁄16⍯ 20 200 14 Straight
For 2 conductor No.’s 8, 6 699* 3⁄8⍯ 5⁄8⍯ 9⁄16⍯ 25 100 20
3 conductor No.’s 8, 6 90 Degree
632 1⍯ 3⁄8⍯ 11⁄64⍯ 11⁄64⍯ 10 100 21 700* 3⁄8⍯ 5⁄8⍯ 9⁄16⍯ 25 100 14
For 2 conductor No.’s 8, 6
3 conductor No.’s 8, 6 ARMORED, METAL CLAD, AND NON-METALLIC CABLE,
NON-METALLIC SHEATHED CABLE CONNECTORS AND FLEXIBLE METALLIC CONDUIT – DIE CAST ZINC
– DIE CAST ZINC Duplex Type
UL File No. E-19188 Diam. of Diam. of Wt
UL File No. E-10438 Weight Cat. Trade Opening Bushed Unit Std Lbs./
Cat. Trade K.O. Unit Std Lbs. Per # Size for Cable Hole Qty Pkg 100
# Size Size Qty Pkg 100
3⁄8⍯ 1⁄2⍯
2699* 3⁄8⍯ 5⁄8⍯ 9⁄16⍯ 25 250 13
759DC 100 1000 4 * UL Listed as grounding means.
For 2 conductor No.’s 14, 12, 10
3 conductor No.’s 14, 12
2631 3⁄4⍯ 3⁄4⍯ 50 500 9
For 3 conductor No.’s 8, 6 FLEXIBLE METALLIC CONDUIT CONNECTORS
2632 1⍯ 1⍯ 25 250 12
For 3 conductor No.’s 6, 4
– MALLEABLE IRON
2633 11⁄4⍯ 11⁄4⍯ 10 100 22
Standard Materials & Finishes:
For 3 conductor No.’s 3, 2
Material: Malleable Iron
2670 11⁄2⍯ 11⁄2⍯ 5 50 25
Steel Locknut
For 3 conductor No. 2/0
Finishes: Zinc plated
2671 2⍯ 2⍯ 10 40 40
For 3 conductor No. 4/0 Squeeze Type
UL File No. E-19189
ARMORED CABLE AND FLEXIBLE METALLIC CONDUIT Diam. of Diam. of Wt
CONNECTORS – MALLEABLE IRON 707 Cat. Trade Opening Bushed Unit Std Lbs./
# Size for Cable Hole Qty Pkg 100
Set Screw Type 3⁄8⍯ 5⁄8⍯ 3⁄8⍯
UL File No. E-19188 Diam. of Diam. of Wt 707 100 500 7
1⁄2⍯ 15⁄16⍯ 5⁄8⍯
Cat. Trade Opening Bushed Unit Std Lbs./ 708 708 50 200 14
709 3⁄4⍯ 11⁄8⍯ 3⁄4⍯ 20 100 22
# Size for Cable Hole Qty Pkg 100
702-V 3⁄8⍯ 5⁄8⍯ 7⁄16⍯ 100 500 7 710 1⍯ 13⁄8⍯ 1⍯ 20 100 31
For 2 conductor No.’s 14, 12 712 711 11⁄4⍯ 121⁄32⍯ 15⁄16⍯ 10 50 46
3 conductor No.’s 14, 12 712 11⁄2⍯ 17⁄8⍯ 11⁄2⍯ 5 25 79
4 conductor No. 14, 5⁄16⍯ flex 713 2⍯ 21⁄2⍯ 2⍯ 2 10 101
714 21⁄2⍯ 27⁄8⍯ 23⁄8⍯ 2 10 161
QUICK-LOK® CONNECTORS FOR ARMORED AND 715 3⍯ 39⁄16⍯ 3⍯ 1 5 220
METAL CLAD CABLE AND FMC – STEEL
721 31⁄2⍯ 4⍯ 213⁄32⍯ 1 1 470
UL File No. E-19188
722 4⍯ 419⁄32⍯ 331⁄32⍯ 1 1 610
Features: Straight – Insulated
ɀ No Locknut required UL File No. E-19189 Diam. of Diam. of Wt
ɀ Single-unit or duplex construction with captive clamp Cat. Trade Opening Bushed Unit Std Lbs./
ɀ Connects 50 MC, AC, and Flex RW cable sizes with just three fittings 1708 # Size for Cable Hole Qty Pkg 100
ɀ Easy to install: tilt, insert and snap down 1707 3⁄8⍯ 5⁄8⍯ 3⁄8⍯ 100 500 8
ɀ Single unit construction eliminates loose component parts, integral 1708 1⁄2⍯ 15⁄16⍯ 5⁄8⍯ 50 200 14
green plastic insulated throat bushing provides maximum protection 1712 1709 3⁄4⍯ 11⁄8⍯ 3⁄4⍯ 20 100 17
for wire installation 1710 1⍯ 13⁄8⍯ 1⍯ 20 100 26
ɀ Concrete tight when taped
1711 11⁄4⍯ 121⁄32⍯ 15⁄16⍯ 10 50 42
Standard Materials & Finishes: 1712 11⁄2⍯ 17⁄8⍯ 11⁄2⍯ 5 25 77
Material: Tubular Steel 1713 2⍯ 21⁄2⍯ 2⍯ 2 10 100
Finish: Zinc plated
Trade Unit Std. Wt. 1714 21⁄2⍯ 27⁄8⍯ 23⁄8⍯ 2 10 160
Cat. # Size Qty. Pkg. Lbs./100 1715 3⍯ 39⁄16⍯ 3⍯ 1 5 221
1⁄2⍯ single 1721 31⁄2⍯ 4⍯ 313⁄32⍯ 1 1 470
QLK50S 50 500 9
1722 4⍯ 419⁄32⍯ 331⁄32⍯ 1 1 610
For 14/4 to 10/3
* UL Listed flexible metallic conduit fittings are suitable
For 3⁄8⍯ FMC
as grounding means under NEC 350-5 and suitable for
QLK75 3/4⍯ 25 250 11.5
hazardous location use per Class I, Division 2, NEC
For 10/3 to 6/3
501-4(b).
For 3⁄8⍯ and 1⁄2⍯ FMC
QLK50D 1/2⍯ duplex 25 250 11
For 14/4 to 10/3
US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 305
STIBOINFO((CRH:66008com:CP:305))
PDFINFO CH0 9 F - 2 8
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0306-4 Name: CP-306 DATE: JAN 19 2006 Time: 5:16:37 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
ARMORED CABLE AND FLEXIBLE METALLIC CONDUIT ARMORED CABLE AND FLEXIBLE METALLIC CONDUIT
ɀ CP Cable Fittings
STIBOINFO((CRH:66008com:CP:306))
PDFINFO CH0 9 F - 2 9
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0307-6 Name: CP-307 DATE: JAN 19 2006 Time: 5:16:38 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
ARMORED CABLE AND FLEXIBLE METALLIC CONDUIT ARMORED CABLE AND FLEXIBLE METALLIC CONDUIT
ɀ CP Cable Fittings
CONNECTORS – DIE CAST ZINC CONNECTORS – MALLEABLE IRON
Squeeze Type* 90° Angle – Non–Insulated Clamp Type* 90° Angle – Non–Insulated
UL File No. E-19188
UL File No. 19189 or E-19189
Diam. of Diam. of Wt
Cat. Trade Opening Bushed Unit Std Lbs./
Weight # Size for Cable Hole Qty Pkg 100
Cat. Trade Unit Std Lbs. Per 724 3⁄8⍯ 21⁄32⍯ 17⁄32⍯ 50 200 15
724
# Size Qty Pkg 100 For 2 conductor No.’s 14, 12, 10
724DC 3⁄8⍯ 25 250 8 3 conductor No.’s 14, 12, 10
736DC 1⁄2⍯ 15 150 11 4 conductor No.’s 14, 12
738DC 3⁄4⍯ 12 120 15 Flexible metallic conduit 5⁄16⍯ and 3⁄8⍯
739DC† 1⍯ 5 50 25 740 736 1⁄2⍯ 15⁄16⍯ 9⁄16⍯ 25 100 19
3⁄4⍯ 11⁄8⍯ 13⁄16⍯
740DC† 11⁄4⍯ 4 40 41 738 20 100 31
741DC† 11⁄2⍯ 2 12 117 739 1⍯ 113⁄32⍯ 1⍯ 5 25 50
742DC† 2⍯ 2 12 119 740 11⁄4⍯ 121⁄32⍯ 11⁄4⍯ 2 10 113
744DC 21⁄2⍯ 1 10 286 746 741 11⁄2⍯ 17⁄8⍯ 11⁄2⍯ 1 10 188
745DC 3⍯ 1 4 405 742 2⍯ 21⁄2⍯ 115⁄16⍯ 1 5 236
746DC 31⁄2⍯ 1 4 560 744 21⁄2⍯ 3⍯ 2-192⍯ 1 1 400
747DC 4⍯ 1 3 642 745 3⍯ 31⁄2⍯ 3⍯ 1 1 600
746 3 ⁄2⍯
1 4⍯ 3 ⁄32⍯
13 1 1 1150
Squeeze Type* 90° Angle – Insulated 747 4⍯ 419⁄32⍯ 331⁄32⍯ 1 1 1460
UL File No. 19189 Weight
90° Angle – Insulated
Cat. Trade Unit Std Lbs. Per UL File No. E-19188
# Size Qty Pkg 100 or E-19189
Diam. of Diam. of Wt
1724DC 3⁄8⍯ 25 250 8 Cat. Trade Opening Bushed Unit Std Lbs./
1736DC 1⁄2⍯ 15 150 11 # Size for Cable Hole Qty Pkg 100
1738DC 3⁄4⍯ 12 120 15
1736 1⁄2⍯ 15⁄16⍯ 9⁄16⍯ 25 100 19
1739DC† 1⍯ 5 50 25 1740 1738 3⁄4⍯ 11⁄8⍯ 13⁄16⍯ 20 100 31
1740DC† 11⁄4⍯ 4 40 41
1739 1⍯ 113⁄32⍯ 1⍯ 5 25 50
1741DC† 11⁄2⍯ 2 12 117
1742DC† 2⍯ 2 12 119 1740 1 ⁄4⍯
1 121⁄32⍯ 11⁄4⍯ 2 10 113
1744DC 21⁄2⍯ 1 10 286 1741 11⁄2⍯ 17⁄8⍯ 11⁄2⍯ 1 10 188
1745DC 3⍯ 1 4 405 1746 1742 2⍯ 21⁄2⍯ 115⁄16⍯ 1 5 236
1746DC 31⁄2⍯ 1 4 560 1744 21⁄2⍯ 3⍯ 21⁄2⍯ 1 1 400
1747DC 4⍯ 1 3 642 1745 3⍯ 31⁄2⍯ 3⍯ 1 1 600
† For flexible metallic conduit only 1746 31⁄2⍯ 4⍯ 313⁄32⍯ 1 1 1150
* UL Listed flexible metallic conduit fittings are suitable 1747 4⍯ 419⁄32⍯ 331⁄32⍯ 1 1 1460
as grounding means under NEC 350-5 and suitable for * UL Listed flexible metallic conduit fittings are suitable
hazardous location use per Class I, Division 2, NEC as grounding means under NEC 350-5 and suitable for
501-4(b). hazardous location use per Class I, Division 2, NEC
501-4(b).
STIBOINFO((CRH:66008com:CP:307))
PDFINFO CH0 9 F - 2 9
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0308-22 Name: CP-308 DATE: JAN 19 2006 Time: 5:16:40 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
STIBOINFO((CRH:66008com:CP:308))
PDFINFO CH0 9 F - 3 0
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0309-5 Name: CP-309 DATE: JAN 19 2006 Time: 5:16:41 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
ɀ CP Fittings
SERVICE ENTRANCE ELBOWS – ALUMINUM 10 Foot Coils
Gasketed Weight
UL File No. E-19189 Wgt. Standard Lbs. Per
Grounding
Unit Std. Lbs. Per Cat. # Description Package 100
Cat. # Size Qty. Pkg. 100 3000 3⁄4 × .035 Galvanized 100 10
SLB1 1⁄2⍯ 10 50 25 1⁄4⍯ holes – 1⁄2⍯ to 1⍯ Centers
SLB2 3⁄4⍯ 10 50 30
SLB3 1⍯ 5 25 51 GROUND CLAMP – DIE CAST ZINC
SLB4 11⁄4⍯ 2 10 83 For Bare or Insulated Wire or Armored Grounding Cable
SLB5 11⁄2⍯ 1 5 117
SLB6 2⍯ 1 5 192 Grounding
Conductor Wgt.
SERVICE ENTRANCE CAPS FOR EMT AND RIGID CONDUIT –
Electrode Lug Lbs.
ALUMINUM
Clamping Conductor Unit Std. Per
Clamp Type
Cat. # Range Range Qty. Pkg. 100
UL File No. E-22133 Wgt.
141DC 1⁄2⍯, 3⁄4⍯, 1⍯ #8-#2 25 250 16
Holes in Unit Std. Lbs.
Cat. # Size Insulator Qty. Pkg. Per 100
EH1** 1⁄2⍯ 4-19⁄64⍯ 10 50 52
EH2** 3⁄4⍯ 2-3⁄8 3-13⁄32⍯ 10 50 60
EH3 1⍯ 2-7⁄16⍯ 3-1⁄2⍯ 5 25 48
EH4 11⁄4⍯ 2-7⁄16⍯ 3-5⁄8⍯ 5 25 50
EH5 11⁄2⍯ 2-19⁄32⍯ 1-7⁄16⍯ 3-3⁄4⍯ 3 15 110
EH6 2⍯ 2-3⁄4⍯ 3-1⍯ 1-17⁄32⍯ 5 5 140
EH7 21⁄2⍯ 3-7⁄8⍯ 1-1⍯ 3-1-5⁄16⍯ 1 1 400
EH8 3⍯ 4-1-1⁄8⍯ 3-1-3⁄4⍯ 1 1 650
EH9 31⁄2⍯ 4-1-1⁄8⍯ 3-1-3⁄4⍯ 1 1 650
EH10 4⍯ 4-1-1⁄8⍯ 3-1-3⁄4⍯ 1 1 600
** Zinc
SERVICE ENTRANCE CABLE CONNECTORS – MALLEABLE IRON
Non-watertight for Oval Cable
UL File No. E-22134 Wgt.
Clamp Opening Lbs.
K.O. Width Unit Std. Per
Cat. # Size Min. Max. Qty. Pkg. 100
631 3⁄4⍯ 33⁄64⍯ 13⁄16⍯ 20 200 14
For 2 conductor No.’s 8, 6
3 conductor No.’s 8, 6
632 1⍯ 3⁄8⍯ 11⁄64⍯ 11⁄64⍯ 10 100 21
For 2 conductor No.’s 8, 6
3 conductor No.’s 8, 6
SERVICE ENTRANCE CABLE CONNECTORS – DIE CAST ZINC
Non-watertight for Oval Cable
UL File No. E-10438
Wgt.
Lbs.
K.O. Clamp Opening Unit Std. Per
Cat. #Size Min. Max. Width Qty. Pkg. 100
2631 3⁄4⍯ .300⍯ .075⍯ .075⍯ 50 500 9
2632 1⍯ .350⍯ .920⍯ .920⍯ 25 250 12
2633 11⁄4⍯ .335⍯ .960⍯ .960⍯ 10 100 22
2670 11⁄2⍯ .350⍯ 1.00⍯ 1.00⍯ 5 50 25
2671 2⍯ .700⍯ 1.30⍯ 1.30⍯ 10 40 40
STIBOINFO((CRH:66008com:CP:309))
PDFINFO CH0 9 F - 3 2
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0310-2 Name: CP-310 DATE: JAN 19 2006 Time: 5:16:42 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
CP Junction Boxes
Application and Selection
Application: will affect the material and finish needed to Options and Accessories:
Junction boxes, designed for hazardous and meet weather and corrosive conditions, if
ɀ CP Junction Boxes
† Length and width are inside dimensions. Depth is inside dimension without cover.
In Canada: Enclosures without openings or mountings plate shipped within 1 week. Enclosures with standard openings or mounting plate shipped within 2 weeks
STIBOINFO((CRH:66008com:CP:310))
PDFINFO CH0 0 6 F - 0
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0311-6 Name: CP-311 DATE: JAN 19 2006 Time: 5:16:43 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
ɀ CP Junction Boxes
weatherproof enclosure is
desired, WAB boxes are installed Certifications and
in conduit system to: Compliances:
ɀ act as pull box for conductors
ɀ UL Standard: 50
ɀ provide openings and space
ɀ Dust-proof
for making splices and taps in
ɀ Weatherproof
conductors
ɀ H20 Vehicle Load Rating *
ɀ provide for branch conduit
runs
ɀ provide access to conductors
for maintenance and future
Flat Covers
system changes Wall Length Width Depth Lightning
ɀ enclose and protect electrical Cat. # Thickness (in.) (in.) (in.) (in.) Service
devices WAB040402 5⁄32 4 4 2
Features: WAB040403 3⁄16 4 4 3
WAB040404 1⁄4 4 4 4
ɀ Flat neoprene gasket WAB050503 1⁄4 5 5 3
cemented to the cover. WAB050504 1⁄4 5 5 4
ɀ Wide range of drilled and
tapped and slip hole conduit WAB060403 1⁄4 6 4 3
entrance sizes and locations WAB060404 7⁄32 6 4 4
permits extreme flexibility of use WAB060603 1⁄4 6 6 3
in conduit system. WAB060604 3⁄16 6 6 4
ɀ Internal equipment mounting WAB060606 9⁄32 6 6 6
pads available blind tapped for WAB080403 5⁄16 8 4 3
1⁄4⍯ – 20 mounting screws. WAB080604 7⁄32 8 6 4
ɀ Blind tapped into internal WAB080606 5⁄16 8 6 6
mounting pads. WAB080804 5⁄16 8 8 4
ɀ Mounting straps are standard WAB080806 5⁄16 8 8 6
on all boxes. WAB080808 5⁄16 8 8 8
WAB090604 5⁄16 9 6 4
Standard Materials: WAB100604 1⁄4 10 6 4
ɀ Feraloy® iron alloy body WAB100804 1⁄4 10 8 4
ɀ Heavy-gauge steel cover WAB100806 9⁄32 10 8 6
ɀ Neoprene gaskets
ɀ Stainless steel cover screws WAB101006 1⁄4 10 10 6
ɀ Steel mounting straps WAB120604 9⁄32 12 6 4
WAB120606 9⁄32 12 6 6
Standard Finishes: WAB120806 9⁄32 12 8 6
WAB120808 3⁄8 12 8 8
ɀ Feraloy iron alloy and heavy
gauge steel – hot dip galvanized WAB121204 9⁄32 12 12 4
WAB121206 9⁄32 12 12 6
Options: WAB121208 9⁄32 12 12 8
ɀ Factory installed mounting WAB160606 1⁄4 16 6 6
plate... add suffix –MP. WAB161208 5⁄16 16 12 8
ɀ See Ordering Information, WAB181206 5⁄16 18 12 6
beginning pg. 316 for: WAB181208 5⁄16 18 12 8
Drilled and tapped conduit WAB181210 3⁄8 18 12 10
holes WAB181806 3⁄8 18 18 6
Slip holes WAB181812 7⁄16 18 18 12
WAB241212 7⁄16 24 12 12
WAB242408 11⁄32 24 24 8
* Self certify to H20 vehicle load rating equivalent to 16,000 lbs. on cover center.
– available with Lightning Service TM
STIBOINFO((CRH:66008com:CP:311))
PDFINFO CH0 0 6 F - 2
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0312-3 Name: CP-312 DATE: JAN 19 2006 Time: 5:16:45 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
weatherproof, raintight, or
ɀ UL Standard: 50
watertight enclosure is desired,
ɀ Dust-tight
WCB boxes are installed in
ɀ Weatherproof
conduit systems to:
ɀ Raintight
ɀ act as pull box for conductors
ɀ Watertight
ɀ provide openings and space
for making splices and taps in
conductors
ɀ provide for branch conduit
runs
ɀ provide access to conductors
for maintenance and future
system changes
ɀ enclose and protect electrical Ordering Information
devices Wall Length Width Depth Lightning
Cat. # Thickness (in.) (in.) (in.) (in.) Service
Features: 5⁄32
WCB040402 4 4 2
ɀ Flat neoprene gasket
WCB040403 3⁄16 4 4 3
cemented to cover.
WCB040404 1⁄4 4 4 4
ɀ Overlapping cover sheds
WCB050503 1⁄4 5 5 3
environment.
WCB050504 1⁄4 5 5 4
ɀ Wide range of drilled and
tapped and slip hole conduit WCB060403 1⁄4 6 4 3
entrance sizes and locations WCB060404 7⁄32 6 4 4
permits maximum flexibility of WCB060603 1⁄4 6 6 3
use in conduit system. WCB060604 3⁄16 6 6 4
ɀ Internal equipment mounting WCB060606 9⁄32 6 6 6
pads available blind tapped for WCB080403 5⁄16 8 4 3
1⁄4⍯ – 20 mounting screws.
WCB080604 7⁄32 8 6 4
ɀ Blind tapped into internal WCB080606 5⁄16 8 6 6
mounting pads. WCB080804 5⁄16 8 8 4
ɀ Mounting straps are standard WCB080806 5⁄16 8 8 6
on all boxes.
WCB080808 5⁄16 8 8 8
Standard Materials: WCB090604 5⁄16 9 6 4
WCB100604 1⁄4 10 6 4
ɀ Feraloy® iron alloy cover and
WCB100804 1⁄4 10 8 4
body
WCB100806 9⁄32 10 8 6
ɀ Neoprene gaskets
ɀ Stainless steel cover screws WCB101006 1⁄4 10 10 6
ɀ Steel mounting straps WCB120604 9⁄32 12 6 4
WCB120606 9⁄32 12 6 6
Standard Finishes: WCB120806 9⁄32 12 8 6
ɀ Feraloy iron alloy – hot dip WCB120808 3⁄8 12 8 8
galvanized WCB121204 9⁄32 12 12 4
WCB121206 9⁄32 12 12 6
Options: WCB121208 9⁄32 12 12 8
ɀ Factory installed mounting WCB160606 1⁄4 16 6 6
plate... add suffix -MP. WCB161208 5⁄16 16 12 8
ɀ See Ordering Information,
WCB181206 5⁄16 18 12 6
beginning pg. 316, for: 5⁄16
WCB181208 18 12 8
Drilled and tapped conduit 3⁄8
WCB181210 18 12 10
holes
WCB181806 3⁄8 18 18 6
Slip holes
WCB181812 7⁄16 18 18 12
Size Ranges: WCB241212 7⁄16 24 12 12
ɀ 4⍯ x 4⍯ x 2⍯ to WCB242408 11⁄32 24 24 8
24⍯ x 24⍯ x 8⍯
STIBOINFO((CRH:66008com:CP:312))
PDFINFO CH0 0 6 F - 3
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0313-8 Name: CP-313 DATE: JAN 19 2006 Time: 5:16:46 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
ɀ CP Junction Boxes
mounting straps and are
ɀ UL Standard: 50
primarily designed for surface
ɀ CSA Standard C22.2
mounting. WJB heavy duty
ɀ Weatherproof
junction boxes are installed in
ɀ Watertight
conduit systems to:
ɀ CEC: Class II, E,F,G
ɀ act as pull box for conductors
Class III
ɀ provide openings and space
Encl. 3-4
for making splices and taps in
ɀ H20 Vehicle Load Rating *
conductors
ɀ provide for branch conduit Ordering Information
runs
ɀ provide access to conductors Wall Length Width Depth Lightning
for maintenance and future Cat. # Thickness (in.) (in.) (in.) (in.) Service
system changes WJB040403 1⁄4 4 4 3
ɀ enclose and protect electrical WJB040404 1⁄4 4 4 4
equipment WJB060404 1⁄4 6 4 4
WJB060604 1⁄4 6 6 4
Features: WJB060606 1⁄4 6 6 6
ɀ Neoprene gasket cemented to WJB080604 1⁄4 8 6 4
cover. WJB080606 1⁄4 8 6 6
ɀ Wide range of drilled and WJB080804 1⁄4 8 8 4
tapped conduit entrance sizes WJB080806 1⁄4 8 8 6
and locations permits extreme WJB080808 1⁄4 8 8 8
flexibility of use in conduit
WJB100806 1⁄4 10 8 6
system.
WJB100808 1⁄4 10 8 8
ɀ Internal equipment mounting
pads may be drilled and tapped WJB101006 1⁄4 10 10 6
WJB101008 1⁄4 10 10 8
for 1⁄4⍯ – 20 mounting screws.
WJB120606 1⁄4 12 6 6
ɀ Blind tapped into internal
mounting pads. WJB120806 1⁄4 12 8 6
WJB120808 1⁄4 12 8 8
Standard Materials: WJB120810 1⁄4 12 8 10
ɀ Feraloy® iron alloy body WJB121206 5⁄16 12 12 6
ɀ Heavy-gauge steel – cover and WJB121208 5⁄16 12 12 8
mounting straps WJB121212 5⁄16 12 12 12
ɀ Neoprene gaskets WJB121218 5⁄16 12 12 18
WJB140806 5⁄16 14 8 6
Standard Finishes: WJB141410 5⁄16 14 14 10
ɀ Feraloy iron alloy and heavy- WJB161206 5⁄16 16 12 6
gauge steel – hot-dip galvanized
WJB161208 5⁄16 16 12 8
Options: WJB161606 5⁄16 16 16 6
WJB180806 5⁄16 18 8 6
ɀ Factory installed mounting
WJB180808 5⁄16 18 8 8
plate... add suffix -MP.
WJB181006 5⁄16 18 10 6
ɀ See Ordering Information,
beginning pg. 316 for: WJB181206 5⁄16 18 12 6
Drilled and tapped conduit WJB181208 5⁄16 18 12 8
holes WJB181210 5⁄16 18 12 10
Slip holes WJB181212 5⁄16 18 12 12
WJB181218 3⁄8 18 12 18
Size Ranges: WJB181806 3⁄8 18 18 6
ɀ 4⍯ x 4⍯ x 3⍯ to WJB181808 3⁄8 18 18 8
36⍯ x 24⍯ x 24⍯ WJB181812 3⁄8 18 18 12
WJB181818 3⁄8 18 18 18
WJB241208 3⁄8 24 12 8
WJB241212 3⁄8 24 12 12
WJB241808 3⁄8 24 18 8
WJB241810 3⁄8 24 18 10
WJB241812 3⁄8 24 18 12
WJB241818 9⁄16 24 18 18
WJB242412 9⁄16 24 24 12
* Self certify to H20 vehicle load rating WJB242418 9⁄16 24 24 18
equivalent to 16,000 lbs. on cover center. WJB242424 9⁄16 24 24 24
– available with Lightning Service TM WJB302412 9⁄16 30 24 12
WJB302418 9⁄16 30 24 18
WJB362418 9⁄16 36 24 18
WJB362424 9⁄16 36 24 24
STIBOINFO((CRH:66008com:CP:313))
PDFINFO CH0 0 6 F - 4
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0314-11 Name: CP-314 DATE: JAN 19 2006 Time: 5:16:47 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
Application:
WJBF boxes are standard with
ɀ CP Junction Boxes
STIBOINFO((CRH:66008com:CP:314))
PDFINFO CH0 0 6 F - 5
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0315-6 Name: CP-315 DATE: JAN 19 2006 Time: 5:16:48 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
Application:
WEB Junction Boxes are installed:
ɀ CP Junction Boxes
ɀ Where a heavy duty, dust-tight or raintight
enclosure is desired
ɀ To act as pull box for conductors
ɀ To provide openings and space for making
splices and taps in conductors
ɀ To provide for branch conduit runs
ɀ To provide access to conductors for
maintenance and future system changes
ɀ To enclose and protect electrical devices
Options:
All boxes are available with optional
mounting plate, add suffix -MP.
See ordering information beginning on
pg. 316 for:
ɀ Drilled and tapped conduit holes
ɀ Slip holes
STIBOINFO((CRH:66008com:CP:315))
PDFINFO C H 0 0 6 F - 5A
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0316-2 Name: CP-316 DATE: JAN 19 2006 Time: 5:16:49 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
All W-Series cast-iron junction boxes may be ordered with drilled and tapped conduit openings or slip holes – subject to minimum spacing
limitations listed in Table 1.
Table 1
To order a box from the factory with conduit
openings: Minimum spacing between centers of conduits
Size of
Options 1: Conduit 6⍯ 5⍯ 4⍯ 31⁄2⍯ 3⍯ 21⁄2⍯ 2⍯ 11⁄2⍯ 11⁄4⍯ 1⍯ 3⁄4⍯ 1⁄2⍯
Send in a sketch of the box with openings 1⁄2⍯ 5 43⁄8 35⁄8 33⁄8 3 25⁄8 23⁄8 2 17⁄8 13⁄4 15⁄8 11⁄2
specified (subject to spacing limitations 3⁄4⍯ 51⁄8 41⁄2 33⁄4 31⁄2 31⁄8 23⁄4 21⁄2 21⁄8 2 17⁄8 13⁄4
specified in Table 1). OR 1⍯ 51⁄4 45⁄8 4 35⁄8 31⁄4 3 25⁄8 23⁄8 21⁄4 2
11⁄4⍯ 51⁄2 47⁄8 41⁄8 37⁄8 31⁄2 31⁄8 27⁄8 21⁄2 23⁄8
11⁄2⍯ 55⁄8 5 41⁄4 4 35⁄8 31⁄4 3 25⁄8
Option 2: 2⍯ 6 53⁄8 45⁄8 41⁄4 37⁄8 35⁄8 31⁄4
21⁄2⍯ 61⁄4 55⁄8 47⁄8 45⁄8 41⁄4 37⁄8
Step 1: Select one of the four standard
3⍯ 65⁄8 6 53⁄8 5 45⁄8
arrangements in Table 2, based on number
31⁄2⍯ 7 61⁄4 55⁄8 51⁄4
and location of conduit entries.
4⍯ 71⁄4 65⁄8 57⁄8
Step 2: Pick a symbol from Table 3 for each
5⍯ 8 71⁄4
opening in the arrangement (see example).
6⍯ 85⁄8
Step 3: Table 4 lists the maximum size and
number of conduit openings by box size
and the spacing dimensions. Use Table 4 Table 2
to verify the openings selected are
permitted. Standard conduit arrangements
STIBOINFO((CRH:66008com:CP:316))
PDFINFO CH0 0 6 F - 6
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0317-3 Name: CP-317 DATE: JAN 19 2006 Time: 5:16:49 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
Table 4
ɀ CP Junction Boxes
Maximum Size and Number of
W Drilled and Tapped Conduit Openings Spacing Dimensions†
Series Top and Bottom‡ Sides
Cat. # 1 2 3 4 1 2 3 4 s t u v w x y
040402 3⁄4 3⁄4 — — 3⁄4 3⁄4 — — 11⁄4 7⁄8 7⁄8 — — — —
040403 11⁄4 3⁄4 — — 11⁄4 3⁄4 — — 15⁄8 7⁄8 7⁄8 — — — —
040404 2 3⁄4 — — 2 3⁄4 — — 21⁄4 7⁄8 7⁄8 — — — —
050503 11⁄4 3⁄4 — — 11⁄4 3⁄4 — — 15⁄8 11⁄4 11⁄4 — — — —
050504 2 1 — — 2 1 — — 21⁄4 11⁄4 11⁄4 — — — —
060403 11⁄4 3⁄4 3⁄4 — 11⁄4 3⁄4 — — 15⁄8 13⁄8 7⁄8 13⁄4 — — —
060404 2 11⁄2 3⁄4 — 2 3⁄4 — — 21⁄4 13⁄8 7⁄8 13⁄4 — — —
060603 11⁄4 11⁄4 3⁄4 — 11⁄4 11⁄4 3⁄4 — 11⁄4 13⁄8 13⁄8 13⁄4 13⁄4 — —
060604 2 11⁄2 3⁄4 — 2 11⁄2 3⁄4 — 21⁄4 13⁄8 13⁄8 13⁄4 13⁄4 — —
060606 4 11⁄2 3⁄4 — 4 11⁄2 3⁄4 — 33⁄8 13⁄8 13⁄8 13⁄4 13⁄4 — —
080403 11⁄4 11⁄4 1 3⁄4 11⁄4 3⁄4 — — 15⁄8 15⁄8 7⁄8 21⁄2 — — —
080604 2 2 1 3⁄4 2 11⁄2 3⁄4 — 21⁄4 15⁄8 13⁄8 21⁄2 13⁄4 13⁄4 —
080606 4 2 1 3⁄4 4 11⁄2 3⁄4 — 33⁄8 15⁄8 13⁄8 21⁄2 13⁄4 13⁄4 —
080804 2 2 1 3⁄4 3 2 1 3⁄4 21⁄4 15⁄8 15⁄8 21⁄2 21⁄2 13⁄4 13⁄4
080806 4 2 1 3⁄4 4 2 1 3⁄4 33⁄8 15⁄8 15⁄8 21⁄2 21⁄2 13⁄4 13⁄4
080808 4 2 1 3⁄4 4 2 1 3⁄4 41⁄4 15⁄8 15⁄8 21⁄2 21⁄2 13⁄4 13⁄4
090604 2 11⁄4 11⁄2 1 2 11⁄2 3⁄4 — 21⁄4 21⁄4 13⁄8 3 13⁄4 2 —
100604 2 2 11⁄2 1 2 11⁄2 3⁄4 — 21⁄4 21⁄2 13⁄8 23⁄4 13⁄4 21⁄2 —
100804 2 2 11⁄2 1 2 2 1 3⁄4 21⁄4 21⁄2 15⁄8 23⁄4 21⁄2 21⁄2 13⁄4
100806 4 3 11⁄2 1 4 2 1 2⁄4 33⁄8 21⁄2 15⁄8 23⁄4 13⁄4 21⁄2 13⁄4
100808 5 3 11⁄2 1 5 2 1 3⁄4 41⁄2 21⁄2 15⁄8 23⁄4 21⁄2 21⁄2 13⁄4
101006 4 3 11⁄2 1 3 3 11⁄2 1 23⁄8 21⁄2 21⁄2 23⁄4 23⁄4 21⁄2 21⁄2
101008 5 3 11⁄2 1 5 3 11⁄2 1 41⁄4 21⁄2 21⁄2 23⁄4 23⁄4 21⁄2 21⁄2
120604 2 2 2 11⁄2 2 11⁄2 3⁄4 — 21⁄4 3 13⁄8 4 13⁄4 23⁄4 —
120606 4 4 21⁄2 11⁄2 4 11⁄2 3⁄4 — 33⁄8 3 13⁄8 4 13⁄4 23⁄4 —
120806 4 4 21⁄2 21⁄2 4 2 1 3⁄4 33⁄8 3 15⁄8 4 21⁄2 23⁄4 13⁄4
120808 5 4 21⁄2 21⁄2 5 2 1 3⁄4 41⁄4 3 15⁄8 4 21⁄2 23⁄4 11⁄4
121204 2 2 2 11⁄2 2 2 2 11⁄2 21⁄4 3 3 4 4 23⁄4 23⁄4
121206 4 4 21⁄2 11⁄2 4 4 21⁄2 11⁄2 33⁄8 3 3 4 4 23⁄4 23⁄4
121208 5 4 21⁄2 11⁄2 5 4 21⁄2 11⁄2 41⁄4 3 3 4 4 23⁄4 23⁄4
121212 6 4 21⁄2 11⁄2 6 4 21⁄2 11⁄2 5 3 3 4 4 23⁄4 23⁄4
121218 6 4 21⁄2 11⁄2 6 4 21⁄2 11⁄2 5 3 3 4 4 23⁄4 23⁄4
140806 4 4 3 2 4 2 1 3⁄4 33⁄8 31⁄2 15⁄8 41⁄2 21⁄2 31⁄2 13⁄4
141206 4 4 3 2 4 4 21⁄2 11⁄2 33⁄8 31⁄2 3 41⁄2 4 31⁄2 23⁄4
141410 6 4 3 2 6 4 3 2 5 31⁄2 31⁄2 41⁄2 41⁄2 31⁄2 31⁄2
160606 4 4 31⁄2 21⁄2 4 11⁄2 3⁄4 — 33⁄8 4 11⁄2 53⁄8 2 4 —
160806 4 4 31⁄2 21⁄2 4 21⁄2 11⁄2 3⁄4 33⁄8 4 2 53⁄8 25⁄8 4 2
161206 4 4 31⁄2 21⁄2 4 4 21⁄2 11⁄2 33⁄8 4 3 53⁄8 4 4 3
161208 5 5 31⁄2 21⁄2 5 4 21⁄2 11⁄2 41⁄4 4 3 53⁄8 4 4 3
161606 4 4 31⁄2 21⁄2 4 4 31⁄2 21⁄2 33⁄8 4 4 53⁄8 53⁄8 4 4
180806 4 4 4 21⁄2 4 21⁄2 11⁄4 3⁄4 33⁄8 41⁄2 2 6 25⁄8 41⁄2 2
180808 5 5 4 21⁄2 5 21⁄2 11⁄4 3⁄4 41⁄4 41⁄2 2 6 25⁄8 41⁄2 2
181206 4 4 4 21⁄2 4 4 21⁄2 11⁄2 33⁄8 61⁄2 27⁄8 51⁄2 37⁄8 4 23⁄4
181208 5 5 4 21⁄2 5 4 21⁄2 11⁄2 41⁄4 41⁄2 3 51⁄2 4 4 23⁄4
181210 6 5 4 21⁄2 6 4 21⁄2 11⁄2 5 41⁄4 3 51⁄2 4 4 23⁄4
†Spacing dimensions apply to drilled and tapped holes. Space has been provided for a locknut and bushing when drilled and tapped holes are required.
‡Top and bottom are the longer dimensions on enclosures which are not square.
STIBOINFO((CRH:66008com:CP:317))
PDFINFO CH0 0 6 F - 7
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0318-3 Name: CP-318 DATE: JAN 19 2006 Time: 5:16:50 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
Table 4 (continued)
ɀ CP Junction Boxes
†Spacing dimensions apply to drilled and tapped holes. Space has been provided for a locknut and bushing when drilled and tapped holes are required.
‡Top and bottom are the longer dimensions on enclosures which are not square.
STIBOINFO((CRH:66008com:CP:318))
PDFINFO CH0 0 6 F - 8
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0319-2 Name: CP-319 DATE: JAN 19 2006 Time: 5:16:51 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
XD Expansion/Deflection Watertight CP
Corrosion-Resistant
Coupling
Application:
XD couplings can be installed indoors,
ɀ CP Accessories
outdoors, buried underground, or embedded
in concrete in non-hazardous areas. XD’s are
used with standard rigid conduit or PVC rigid
conduit. (PVC requires rigid metal conduit
Junction Box
nipples and rigid metal-to-PVC conduit
adapters.) XD’s provide a flexible and
watertight connection for protection of
conduit wiring systems from damage due to
movement.
Typical applications include:
ɀ Underground conduit feeder runs
1. Axial expansion/contraction. 2. Angular misalignment.
ɀ Runs between sections of concrete subject
to relative movement
ɀ Runs between fixed structures
ɀ Conduit entrances in high-rise buildings
ɀ Bridges
ɀ Marinas, docks, piers XD
Ordering Information
Features: Hub Size Cat. # Hub Size Cat. #
ɀ XD couplings accommodate the following 1 XD3 3 XD8
movements without collapsing or fracturing 11⁄4 XD4 31⁄2 XD9
the conduit, and damaging the wires it 11⁄2 XD5 4 XD010
contains: 2 XD6 5 XD012
1. Axial expansion or contraction up to 3⁄4⍯ 21⁄2 XD7 6 XD014
2. Angular misalignment of the axes of the
coupled conduit runs in any direction to 30° 3. Parallel misalignment.
3. Parallel misalignment of the axes of
coupled conduit runs in any direction to 3⁄4⍯ Dimensions
ɀ Inner sleeve maintains constant I.D. in any
position and provides a smooth insulated Hub
wireway for protection of wire insulation Size a b
ɀ Watertight flexible neoprene outer jacket is 1 7 315⁄16
corrosion resistant and protects the 11⁄4 73⁄8 41⁄4
grounding strap and the attachment points of 11⁄2 71⁄4 41⁄2
the hubs 2 71⁄4 415⁄16
ɀ Tinned copper flexible braid grounding 21⁄2 71⁄2 55⁄16
straps assure grounding continuity 3 75⁄8 515⁄16
ɀ Stainless steel jacket clamps for strength 31⁄2 73⁄4 61⁄2
and corrosion resistance 4 77⁄8 615⁄16
ɀ Standard tapered electrical threads fit 5 73⁄4 8
standard rigid conduit 6 83⁄8 9
ɀ Integral hub bushing protects insulation of
conductors
Standard Materials:
ɀ Hubs – Feraloy® iron alloy
ɀ Outer jacket – molded neoprene
ɀ Jacket clamps – stainless steel
ɀ Inner sleeve – molded plastic
ɀ Grounding straps – tinned copper flexible
braid
Standard Finishes:
ɀ Feraloy – electrogalvanized
ɀ Neoprene – natural (black)
ɀ Molded plastic – natural (brown)
Certifications and
Compliances:
ɀ UL standards: 514B
Size Ranges:
ɀ 1⍯ to 6⍯ (Smaller sizes can be obtained by
using reducing bushings)
STIBOINFO((CRH:66008com:CP:319))
PDFINFO CH0 0 7 F - 8
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0320-3 Name: CP-320 DATE: JAN 19 2006 Time: 5:16:53 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
Application:
XJG expansion couplings are used with rigid
metal conduit and IMC:
Box
Accessories
STIBOINFO((CRH:66008com:CP:320))
PDFINFO CH0 0 7 F - 9
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0321-2 Name: CP-321 DATE: JAN 19 2006 Time: 5:16:54 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
Application:
XJG expansion couplings are used with EMT
ɀ CP Accessories
Conduit:
ɀ without the need for an external bonding
jumper and clamps
ɀ to couple together two (2) sections of
Junction Box
conduit subject to longitudinal movement
ɀ in long conduit runs to permit linear
movement caused by thermal expansion and XJG-EMT – for use with EMT conduit
contraction. Maximum Optional
ɀ on long conduit runs to prevent conduit Conduit Conduit Catalog Bonding A B
from buckling and ensuing circuit failures Size Movement Number Jumper Diameter Length
ɀ indoors or outdoors where conduit
1⁄2⍯ 4⍯ XJG14-EMT BJ14 13⁄4⍯ 103⁄4⍯
expansion occurs and there are wide
temperature ranges 3⁄4⍯ 4⍯ XJG24-EMT BJ24 21⁄8⍯ 11⍯
ɀ in conduit runs that cross structural joints
1⍯ 4⍯ XJG34-EMT BJ34 27⁄16⍯ 111⁄2⍯
ɀ in conduit runs to prevent damage to
conduit supports such as in a building or on 11⁄4⍯ 4⍯ XJG44-EMT BJ44 31⁄8⍯ 151⁄4⍯
a bridge 11⁄2⍯ 4⍯ XJG54-EMT BJ54 35⁄8⍯ 151⁄2⍯
ɀ with optional redundant visible
2⍯ 4⍯ XJG64-EMT BJ64 43⁄4⍯ 151⁄2⍯
grounding strap
21⁄2⍯ 4⍯ XJG74-EMT BJ74 47⁄8⍯ 183⁄4⍯
Standard Materials and
3⍯ 4⍯ XJG84-EMT BJ84 53⁄8⍯ 197⁄8⍯
Finishes
Body 31⁄2⍯ 4⍯ XJG94-EMT BJ94 65⁄8⍯ 211⁄4⍯
ɀ Steel-electrogalvanized 4⍯ 4⍯ XJG104-EMT BJ104 65⁄8⍯ 211⁄4⍯
ɀ Copper-free aluminum - natural
Reducer
ɀ 1⁄2⍯ through 1⍯ - Steel - electrogalvanized
ɀ 11⁄4⍯ through 4⍯ - Feraloy® iron alloy -
electrogalvanized and aluminum paint
Gland Nut
ɀ 1⁄2⍯ through 1⍯ - Steel - electrogalvanized
ɀ 11⁄4⍯ through 4⍯ - Feraloy® iron alloy -
electrogalvanized and aluminum paint
Packing
ɀ Teflon® (trademark of E.I. DuPont Co.) XJG shown with optional bonding jumper
Washer
ɀ Steel - electrogalvanized
Gasket
ɀ Vellum
Bushing
ɀ 1⁄2⍯ through 1⍯ - Steel - electrogalvanized
ɀ 11⁄4⍯ through 4⍯ - Feraloy® iron alloy -
electrogalvanized and aluminum paint
Ground Springs
ɀ Phosphor bronze - electrogalvanized
Ground Strap
ɀ Braided tinned copper * Teflon® is a registered trademark of E.I. DuPont Co.
U-Bolts † XJG expansion couplings use a metallic bushing and ground springs to create a high integrity internal ground connection.
ɀ Malleable iron – electrogalvanized External ground straps offer a redundant ground path and easy visible indication of ground
Options:
Available with redundant† ground strap for
visible indication of grounding – order
separately (BJ Series)
Size Ranges:
ɀ 1⁄2⍯ through 4⍯ conduit size
ɀ 4⍯ maximum conduit movement
Certifications and
Compliances:
ɀ UL Standard: 514B
ɀ CSA Standard: C22.2 No. 18
ɀ NEC Articles 250-77 and 300-7 (b)
ɀ NEMA FB1
STIBOINFO((CRH:66008com:CP:321))
PDFINFO CH0 0 7 F 1 0
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0322-2 Name: CP-322 DATE: JAN 19 2006 Time: 5:16:55 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100
STIBOINFO((CRH:66008com:CP:322))
PDFINFO CH0 0 7 F 1 1