0% found this document useful (0 votes)
3 views3 pages

Anemometro DNA121 en

The document details a combined wind speed and direction sensor that simplifies installation and is more cost-effective than traditional two-sensor kits. It features various output options, a wide power supply range, and high damage thresholds, with specifications validated under ISO17025 standards. Additionally, it includes accessories for calibration and spare parts for maintenance.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
3 views3 pages

Anemometro DNA121 en

The document details a combined wind speed and direction sensor that simplifies installation and is more cost-effective than traditional two-sensor kits. It features various output options, a wide power supply range, and high damage thresholds, with specifications validated under ISO17025 standards. Additionally, it includes accessories for calibration and spare parts for maintenance.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

WIND SPEED & DIRECTION

(Wind cup and vane)


Combined wind speed and
direction sensors
Environmental Monitoring Solutions

Alternative signal outputs: (Hz+0÷1 V), 0÷5 V, 4÷20 mA,


RS485 Modbus

Wide power supply: 9÷30 Vac/dc

Simple to install on pole of 5 cm diameter

High demage threshold up to 75 m/s

Optional cable up to L.100 m

In house ISO17025 accreditate calibration laboratory

Combined wind speed and wind direction sensor. This sensor range includes, in a single apparatus, transducers for both
wind speed and wind direction measurement. Its use simplifies installation requirements, other than being smaller, lighter
and cheaper than the general 2-sensors kit. Accuracy and thresholds are anyway near to be comparable with 2-sensors cup
and vane kit alternatives. Different data output signals are available.

Technical Specifications

DNA821
Order numb. DNA121 DNA821.1 DNA827 DNA921
DNA821.2
Wind speed output 0÷833 Hz 4÷20 mA 0÷5 Vdc RS485

Wind speed 0÷75 m/s DNA821: 0÷60 m/s 0÷60 m/s 0÷60 m/s
measuring range (demage limit) DNA821.1: 0÷50 m/s
DNA821.2: 0÷75 m/s

Wind Direction output 0÷1 Vdc 4÷20 mA 0÷5 Vdc RS485

Protocol - - - Modbus RTU®,


TTY-ASCII

Configuration - - - Hyperterminal

EMC EN61326-1 2013 EN61326-1 2013 EN61326-1 2013 EN61326-1 2013

RS485 protection - - - Galvanic insulation


(3 kV, UL1577)

RS485 speed - - - 1200÷115 kbps

Power supply 10÷30 Vac/dc 10÷30 Vac/dc 10÷30 Vac/dc 10÷30 Vac/dc

Power consumption 0,5 W 0,5 W 0,5 W 0,5 W

Data logger M-Log (ELO008), M-Log (ELO008) - E-Log using RS485-


compatibility >232 converter,
E-Log, E-Log,
Alpha-Log.
Alpha-Log using Alpha-Log using
ALIEM module. ALIEM module.

MW9000-ENG-06-15/04/2020
1
Combined wind speed and direction sensors

Common Technical Specifications

Wind speed Principle N.32 step optoelectronic disk


Accuracy 0÷25 m/s: ± 0,25 m/s or 3%
>25 m/s: 2%
Threshold 0,25 m/s
Delay distance 4,8 m (@ 10 m/s). According to VDI3786 and ASTM 5096-96
Resolution 0,06 m/s
Wind direction Principle Hall effect system
Measuring range 0÷360°
Accuracy 1%
Threshold 0,15 m/s
Resolution 0,3°
Delay distance 1,2 m (@ 10 m/s). According to VDI3786 and ASTM 5366-96
Damping coeff. 0,21 (@ 10 m/s). According to VDI3786 and ASTM 5096-96
General Information Operative damage limit 75 m/s
Connector 7 pin IP65 watertight connector
Housing Anodized aluminum,
Cup PA6 plastic and fiberglass
Vane Aluminum
Protection type IP66
Mounting Mast Ø 48 ÷ 50 mm.
Operative temperature >-30°C (without ice)

DNAnnn sensors serie has a very low measurement Sensor’s design has been made to prevent water and
threshold (0,26 m/s) and at the same time, a very high dirtiness to enter inside the sensor’s bearings area. This
demage limit (75 m/s). All specification are tested in LSI- permits to avoid the bearing replacement for the entire
LASTEM’s wind tunnel under ISO17025 requirements. sensor life.

2
2
Combined wind speed and direction sensors

Accessories

SVICA2203 ISO9001 type calibration certificate (Wind Speed)

SVICA2304 ISO9001 type calibration certificate (Wind Direction)

SVACA2216 ISO17025-ACCREDIA type calibration certificate (Wind Speed)

DWA505 Cable L. = 5 m.

DWA510 Cable L. = 10 m.

DWA525 Cable L. = 25 m.

DWA526 Cable L. = 50 m.

DWA527 Cable L. = 100 m.

MG2251 7 pin free female connector

DNA124 Spare part: rotor

DNA127 Spare part: vane

MM2011 Spare part: bearing for Wind direction (QT.2 required)

MM2020 Spare part: bearing for Wind speed (QT.2 required)

LSI LASTEM is an ISO17025 accreditated laboratory for air speed


measurements. All sensors manufactured are tested inside this labora-
tory. LSI LASTEM provides Test report for any sensor supplied and on
request, ISO17025 or ISO9001 calibration certificates (see Accessories
list).

LSI LASTEM Srl Tel. +39 02 954141


Via Ex SP. 161 Dosso, 9 Fax +39 02 95770594
20090 Settala (MI) Email [email protected]
Italy www.lsi-lastem.com