REACH
PCC CHECKLIST
NAME OF PROJECT:
DATE:
LOCATION:
DRAWING NO.:
CONTRACTOR NAME:
PCC Pre Pour Checks
S.No. INSPECTION PARAMETERS YES NO REMARKS
1 Anti termite done(if required)
2 Check for signed WIR and concrete pour inspection form
3 Check for concrete placement done (by pump/crane bucket transit
mixer)
4 Check for workability; slump test conducted at site, grade of concrete,
5 Level guide checked by surveyor before starting concreting.
6 Dimensions of excavated area are as per approved drawings.
Check for curing arrangement,Side supports (ensuring the rigidity)
7
fixed
PCC Post Pour Checks
S.No. INSPECTION PARAMETERS YES NO REMARKS
1 Curing done properly for the 7 days
2 Surface defects (surface cracks/honey combing/cold joints)
3 Nature of defects (major defects)
If yes
4 Nature of defects (minor defects)
5 Check for finishing, PCC surface finish acceptable
6 Check for final level of PCC as per drawing
Validation Contractor PMC REACH
GPL
Name
Signature
Date